FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Sercomm Corporation/
  3. P27IP5446A

P27IP5446A11AX ROUTER_NON IOT

Sercomm Corporation
11AX ROUTER_NON IOT - FCC ID P27IP5446A - Sercomm Corporation
Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Jul 23, 2020
Application Purpose
Original Equipment
Date of Application
Jul 23, 2020
Equipment Note
11AX ROUTER_NON IOT
Frequency Range
5745.00000000 - 5825.00000000
Company
Sercomm Corporation
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Sercomm Confidential Proprietary Page 1 SAX1V1R User Manual Copyright© 2020 by Sercomm Corp. All rights reserved. Sercomm Confidential Proprietary Page 2 Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. For operation within 5.15 ~ 5.25GHz / 5.47 ~5.725GHz frequency range, it is restricted to indoor environment. This device meets all the other requirements specified in Part 15E, Section 15.407 of the FCC Rules. Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 41cm between the radiator & your body Sercomm Confidential Proprietary Page 3 Product Spec Product Spec: Wi-Fi: 802.11 a/b/g/n/ac/ax (2.4G & 5GHz) WAN: 2.5G*1 LAN: 1G*3, Reset Button: 1 Power: DC IN 12V/3A Status LED: 1 (RGB LED) Label and Location: Sercomm Confidential Proprietary Page 4 Chapter 1: Item in the Box You will see following items when opening the box SAX1V1R 802.11ax router: 1 Power adaptor (DC IN: 12V/3A): 1 Ethernet Cable: 1 Wall-mount bracket: 1 Wall-mount screw and washer: 1 Sercomm Confidential Proprietary Page 5 Chapter 2: Prepare to Power On 1. Connect the WAN cable to the RJ45 port (Internet) 2. Connect the LAN cable to the RJ45 port (Ethernet) 3. Tight up the SAX1V1R with wall mount bracket (Option) 4. Connect the power adaptor DC plug with SAX1V1R Power connector, connect the power adaptor to AC Plug Chapter 3: LED Behavior When Boot Up Device LED MUST illuminate in 2 seconds or less when it has started receiving power from mains. Device LED MUST begin “Searching for Internet Connection” immediately after device has finished booting. LED Color: Blue LED state: FLASHING LED will turns to solid blue after Internet is found Sercomm Confidential Proprietary Page 6 Chapter 4: Install Wall Mount Bracket User has to prepare wall mount kit as below before install wall-mount bracket. Once wall mount kit installed on the wall, user can install the wall mount screw and washer on SAX1V1R.

Cover Letter(s)

SercommCorporation中磊電子股份有限公司 TaipeiOffice:8F,No.3-1,YuanQuSt.,NanKang,Taipei115,Taiwan,R.O.C. TEL:886-2-2655-3988FAX:886-2-2655-3966 Date:2020-06-16 FCCID:P27IP5446A Totheattentionof FederalCommunicationsCommission AuthorizationandEvaluationDivision PermanentConfidentialityRequest PursuanttoSections0.457and0.459oftheCommission’sRules,theApplicantherebyrequests confidentialtreatmentofinformationaccompanyingthisApplicationasoutlinedbelow: Schematics BlockDiagram OperationalDescription SoftwareOperationalDescription Theabovematerialscontaintradesecretsandproprietaryinformationnotcustomarilyreleasedto thepublic.ThepublicdisclosureofthesemattersmightbeharmfultotheApplicantandprovide unjustifiedbenefitstoitscompetitors. TheApplicantunderstandsthatpursuanttoRule0.457,disclosureofthisApplicationandall accompanyingdocumentationwillnotbemadebeforethedateoftheGrantforthisapplication. Sincerelyyours, -------------------------------------------- SercommCorporation NickWu/Engineer TEL:886-2-2655-3988*2556 FAX:886-2-2655-3965 E-mail:[email protected]

Cover Letter(s)

Sercomm Corporation中磊電子股份有限公司 Taipei Office: 8F, No.3-1, YuanQu St., NanKang, Taipei 115, Taiwan, R.O.C. TEL: 886-2-2655-3988 FAX: 886-2-2655-3966 Date: 2020-07-20 FCC ID : P27IP5446A To the attention of Federal Communications Commission Authorization and Evaluation Division Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the commission’s rules, we request short-term confidential treatment for the following information until 150 days after the Grant Date of Equipment Authorization in order to ensure sensitive business information remains confidential until the actual marketing of the device: External photos Test Setup photos User’s manual Internal Photos Sincerely yours, ----------------------------------------------------- Sercomm Corporation Nick Wu/ Engineer TEL: 886-2-2655-3988*2556 FAX: 886-2-2655-3965 E-mail: [email protected]

Cover Letter(s)

SercommCorporation中磊電子股份有限公司 TaipeiOffice:8F,No.3-1,YuanQuSt.,NanKang,Taipei115,Taiwan,R.O.C. TEL:886-2-2655-3988FAX:886-2-2655-3966 Date:2020-06-16 FCCID:P27IP5446A AUTHORIZATIONLETTER Towhomitmayconcern: We,theundersigned,herebyauthorizeAndreaHsia/SupervisorofBureauVeritasConsumer ProductsServices(H.K.)Ltd.,TaoyuanBranch(BVCPSTaoyuan)ofTaiwantoactonourbehalfinall mannersrelatingtoFCCapplicationforequipmentauthorization,includingsigningofalldocuments relatingtothesematters.AnyandallactscarriedoutbyAndreaHsia/SupervisorofBVCPSTaoyuan onourbehalfshallhavethesameeffectasactsofourown. Ifyouhaveanyquestionsregardingtheauthorization,pleasedon’thesitatetocontactus. Sincerelyyours, -------------------------------------------- SercommCorporation NickWu/Engineer TEL:886-2-2655-3988*2556 FAX:886-2-2655-3965 E-mail:[email protected]

External Photos

Reference No.:200610D09-ExtPho Page 1/8 CONSTRUCTION PHOTOS OF EUT Reference No.:200610D09-ExtPho Page 2/8 Reference No.:200610D09-ExtPho Page 3/8 Reference No.:200610D09-ExtPho Page 4/8 Reference No.:200610D09-ExtPho Page 5/8 Reference No.:200610D09-ExtPho Page 6/8 Reference No.:200610D09-ExtPho Page 7/8 Reference No.:200610D09-ExtPho Page 8/8

ID Label/Location Info

FCC ID: P27IP5446A TESTED TO COMPLY WITH FCC STANDARDS PROPERT Y OF CHARTER COMMUNICATIONS (SPECTRUM) Equipment use is subjec t to Spec trum’s ser vice agreement, including its arbitration provisions (available at www.spec trum.com). This equipment is provided “as is”, and user accepts all risk of loss/damages from use. This device complies with Par t 15 of the FCC Rules. Operation is subjec t to the following two conditions: (1) this device may not cause harmful inter ference, and (2) this device must accept any inter ference received, including inter ference that may cause undesired operation. SAX1V1R Sercomm Corporation Char ter Device Info Rating: 12V 3A LISTED EXXXXX I.T.E. Made in XXXXXX Rubber Foot Labels & Stickers: FCC ID: P27IP5446A Bottom of EUT Label Location

Internal Photos

Reference No.:200610D09-IntPho Page 1/26 CONSTRUCTION PHOTOS OF EUT Reference No.:200610D09-IntPho Page 2/26 Reference No.:200610D09-IntPho Page 3/26 Reference No.:200610D09-IntPho Page 4/26 Reference No.:200610D09-IntPho Page 5/26 Reference No.:200610D09-IntPho Page 6/26 Reference No.:200610D09-IntPho Page 7/26 Reference No.:200610D09-IntPho Page 8/26 Reference No.:200610D09-IntPho Page 9/26 Reference No.:200610D09-IntPho Page 10/26 Reference No.:200610D09-IntPho Page 11/26 Reference No.:200610D09-IntPho Page 12/26 Reference No.:200610D09-IntPho Page 13/26 Reference No.:200610D09-IntPho Page 14/26 Reference No.:200610D09-IntPho Page 15/26 Reference No.:200610D09-IntPho Page 16/26 Reference No.:200610D09-IntPho Page 17/26 Reference No.:200610D09-IntPho Page 18/26 Reference No.:200610D09-IntPho Page 19/26 Reference No.:200610D09-IntPho Page 20/26 Reference No.:200610D09-IntPho Page 21/26 Reference No.:200610D09-IntPho Page 22/26 Reference No.:200610D09-IntPho Page 23/26 Reference No.:200610D09-IntPho Page 24/26 Reference No.:200610D09-IntPho Page 25/26 Reference No.:200610D09-IntPho Page 26/26

RF Exposure Info

Report No.: SA200610D09 Page No. 1 / 6 Report Format Version: 6.1.1 RF Exposure Report Report No.: SA200610D09 FCC ID: P27IP5446A Test Model: SAX1V1R Received Date: Jun. 10, 2020 Test Date: Jun. 11 to Jul. 6, 2020 Issued Date: Jul. 8, 2020 Applicant: Sercomm Corp. Address: 8F, No. 3-1, YuanQu St., NanKang, Taipei 115, Taiwan, R.O.C. (NanKang Software Park) Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Lin Kou Laboratories Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan FCC Registration / Designation Number: 198487 / TW2021 This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. Report No.: SA200610D09 Page No. 2 / 6 Report Format Version: 6.1.1 Table of Contents Release Control Record .................................................................................................................................. 3 1 Certificate of Conformity ...................................................................................................................... 4 2 RF Exposure .......................................................................................................................................... 5 2.1 Limits for Maximum Permissible Exposure (MPE) .............................................................................. 5 2.2 MPE Calculation Formula ................................................................................................................... 5 2.3 Classification ....................................................................................................................................... 5 3 Calculation Result of Maximum Conducted Power ........................................................................... 6 Report No.: SA200610D09 Page No. 3 / 6 Report Format Version: 6.1.1 Release Control Record Issue No. Description Date Issued SA200610D09 Original release Jul. 8, 2020 Report No.: SA200610D09 Page No. 4 / 6 Report Format Version: 6.1.1 1 Certificate of Conformity Product: 11AX ROUTER_NON IOT Brand: Charter Spectrum Test Model: SAX1V1R Sample Status: Engineering sample Applicant: Sercomm Corp. Test Date: Jun. 11 to Jul. 6, 2020 Standards: FCC Part 2 (Section 2.1091) References Test Guidance: KDB 447498 D01 General RF Exposure Guidance v06 IEEE C95.3 -2002 The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s RF characteristics under the conditions specified in this report. Prepared by : , Date:Jul. 8, 2020 Annie Chang / Senior Specialist Approved by : , Date:Jul. 8, 2020 Rex Lai / Associate Technical Manager Report No.: SA200610D09 Page No. 5 / 6 Report Format Version: 6.1.1 2 RF Exposure 2.1 Limits for Maximum Permissible Exposure (MPE) Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Average Time (minutes) Limits For General Population / Uncontrolled Exposure 300-1500 ... ... F/1500 30 1500-100,000 ... ... 1.0 30 F = Frequency in MHz 2.2 MPE Calculation Formula Pd = (Pout*G) / (4*pi*r 2 ) where Pd = power density in mW/cm 2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm 2.3 Classification The antenna of this product, under normal use condition, is at least 41cm away from the body of the user. So, this device is classified as Mobile Device. Report No.: SA200610D09 Page No. 6 / 6 Report Format Version: 6.1.1 3 Calculation Result of Maximum Conducted Power Frequency Band (MHz) Max Average Power (dBm) Antenna Gain (dBi) Distance (cm) Power Density (mW/cm 2 ) Limit (mW/cm 2 ) CDD Mode 2412-2462 29.99 9.68 41 0.4388 1 5180-5240 27.37 10.78 41 0.3092 1 5745-5825 29.99 10.48 41 0.5275 1 Beamforming Mode 2412-2462 26.26 9.68 41 0.1859 1 5180-5240 25.07 10.78 41 0.1821 1 5745-5825 25.20 10.48 41 0.1751 1 Note: 1. Determining compliance based on the results of the compliance measurement, not taking into account measurement instrumentation uncertainty. 2. Directional gain: 2.4GHz Band: Directional gain = 10 log[(10 G1 /20 + 10 G2 /20 + ... + 10 GN /20 ) 2 /2] = 9.68dBi 5180 ~ 5240MHz: Directional gain = 10 log[(10 G1 /20 + 10 G2 /20 + ... + 10 GN /20 ) 2 /2]= 10.78dBi 5745 ~ 5825MHz: Directional gain = 10 log[(10 G1 /20 + 10 G2 /20 + ... + 10 GN /20 ) 2 /2]= 10.48dBi 3. 2.4GHz & 5GHz technologies can transmit at same time. Conclusion: The formula of calculated the MPE is: CPD1 / LPD1 + CPD2 / LPD2 + ......etc. < 1 CPD = Calculation powe…

Text truncated - open the document above for the full version.

Test Report

Report No.: RF200610D09-1 Page No. 1 / 95 Report Format Version:6.1.2 FCC Test Report Report No.: RF200610D09-1 FCC ID: P27IP5446A Test Model: SAX1V1R Received Date: Jun. 10, 2020 Test Date: Jun. 12 to Jul. 6, 2020 Issued Date: Jul. 8, 2020 Applicant: Sercomm Corp. Address: 8F, No. 3-1, YuanQu St., NanKang, Taipei 115, Taiwan, R.O.C. (NanKang Software Park) Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Lin Kou Laboratories Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan FCC Registration / Designation Number: 198487 / TW2021 This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. Report No.: RF200610D09-1 Page No. 2 / 95 Report Format Version:6.1.2 Table of Contents Release Control Record .................................................................................................................................. 4 1 Certificate of Conformity ...................................................................................................................... 5 2 Summary of Test Results ..................................................................................................................... 6 2.1 Measurement Uncertainty ................................................................................................................... 6 2.2 Modification Record ............................................................................................................................ 6 3 General Information .............................................................................................................................. 7 3.1 General Description of EUT ................................................................................................................ 7 3.2 Description of Test Modes ................................................................................................................... 9 3.2.1 Test Mode Applicability and Tested Channel Detail ........................................................................... 10 3.3 Duty Cycle of Test Signal .................................................................................................................. 13 3.4 Description of Support Units ............................................................................................................. 14 3.4.1 Configuration of System under Test .................................................................................................. 14 3.5 General Description of Applied Standards and References ............................................................. 15 4 Test Types and Results ...................................................................................................................... 16 4.1 Radiated Emission and Bandedge Measurement ............................................................................. 16 4.1.1 Limits of Radiated Emission and Bandedge Measurement .............................................................. 16 4.1.2 Test Instruments ................................................................................................................................ 17 4.1.3 Test Procedures ................................................................................................................................. 18 4.1.4 Deviation from Test Standard ............................................................................................................ 18 4.1.5 Test Setup .......................................................................................................................................... 19 4.1.6 EUT Operating Conditions ................................................................................................................. 20 4.1.7 Test Results ....................................................................................................................................... 21 4.2 Conducted Emission Measurement .................................................................................................. 53 4.2.1 Limits of Conducted Emission Measurement .................................................................................... 53 4.2.2 Test Instruments ................................................................................................................................ 53 4.2.3 Test Procedures ................................................................................................................................. 54 4.2.4 Deviation from Test Standard ............................................................................................................ 54 4.2.5 Test Setup ..................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Reference No.: RF200610D09 Page No. 1 / 3 PHOTOGRAPHS OF THE TEST CONFIGURATION CONDUCTED EMISSION TEST Reference No.: RF200610D09 Page No. 2 / 3 RADIATED EMISSION TEST <Frequency Range below 1GHz> Reference No.: RF200610D09 Page No. 3 / 3 RADIATED EMISSION TEST <Frequency Range above 1GHz>

Contact Information

Applicant

Nick Wu(Engineer)
[email protected]886-2-2655-3988Fax: 886-2-2655-3965

Test Firm

Bureau Veritas CPS(H.K.) Ltd., Taoyuan BranchLiu Ken
[email protected]+886-3-2600609Fax: +886-3-2115834

Technical Specifications

#Rule PartsFrequency RangePower Output
215E5.75 GHz - 5.83 GHz998.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is maximum combined conducted output power. This device supports 20, 40 and 80 MHz bandwidth modes. The product must be installed such that its antenna(s) can provide a separation distance of at least 41 cm from all persons and must not transmit simultaneously with any other transmitter, except in accordance with FCC multi-transmitter product procedures or as described in this filing. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. Operation of this device is restricted to indoor use only.

Other Applications from Sercomm Corporation

P27-WATERZW60R0

WIRELESS WATER AND TEMPERATURE SENSOR

Sep 02, 2026

Equipment Class

DTS - Digital Transmission System
P27-SMOKEZW60R0

Smoke-Heat Detector, Combo, Smoke-Heat-CO

Aug 26, 2026

Equipment Class

DTS - Digital Transmission System
P27-HEATZW60R0

Heat Detector

Aug 26, 2026

Equipment Class

DTS - Digital Transmission System
P27-COZW60R0

Carbon Monoxide Detector

Aug 25, 2026

Equipment Class

DTS - Digital Transmission System
P27-MOTIONZW60R0

WIRELESS PIR MOTION SENSOR

Aug 04, 2026

Equipment Class

DTS - Digital Transmission System