Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
RP131 Wireless PoE Adapter Installation Guide Ver.1.1 Page 1 Overview The RP131 (Wireless Adapter) is Wireless client with power supply, it supply the power to the IP camera, it also connect the IP camera to your existing Wireless network. Page 2 Physical Details Figure 1: RP131(Wireless PoE Adapter) Page 3 LEDs Power (Green) On - Normal operation. Off - No power. Green On - Associate to WiFi AP Off - Not associate to WiFi AP Flashing - Transmitting/Receiving Data Wireless/ WPS Amber On - WPS failed (30 sec) Off - No WPS action or WPS Succeed Flashing - WPS is processing (< 2 min) Ethernet (Green) On - Ethernet connection is active. Off - No Ethernet connection. Flashing - Data is being transmitted or received via the Ethernet Port. PoE (Amber) On - The PoE powered device (PD) is connected and the port is supplying power successfully Off - No PoE powered device (PD) connected Page 4 Buttons WPS Button Establish a secure connection between the Wireless router (or Access Point) and IP camera Push-Button-Method - Press and hold the WPS button, but not no more than 3 seconds PIN Method - Press the WPS button and hold for greater than 3 seconds LAN Port Use a standard LAN cable to connect the RP131 to the IP Camera Page 5 The installation allows the RP131 to directly connect to a wireless router (or Wireless Access Point). You can extend the range of your wireless network. Page 6 1. Locate the RP131 near the Wireless Access Point while doing the configuration. 2. Make sure the Wireless Access Point is on and working properly. 3. Plug the RP131 into the AC power slot, then the Power LED will remain on. 4. Plug the IP camera into the AC power slot 5. Connect a standard LAN cable from the RP131 to IP camera 6. Push the WPS button on the Wireless Access Point and make sure the Wireless Access Point is in WPS mode. (The LED on the AP will blink and active for 2 minutes.) 7. Push and hold the WPS button on the RP131 for more than 3 seconds. The WPS LED on the device will start blinking for 2 minutes. The RP131 will automatically associate to the Wireless Access Point with the strongest signal and make connections.) 8. The connection of the RP131 and Wireless Access Point is successfully established after the Wireless LED remains on The RP131 (Wireless PoE Adapter) is now ready for use. Page 7 Dimensions 91.7(L) x 57(W) x 61.2(H) mm Wireless Standards IEEE 802.11 b/g/n Antenna Internal x 2 LEDs 1 * Power 1 * Wireless / WPS 1 * Ethernet 1 * PoE PoE IEEE802.3 af Class 3 Maximum outpout power : 10 Watts DC 48V, 208mA(maximum) Over current protection Data pin : 1, 2, 3, 6 Power pin : 4, 5, 7, 8 Ethernet Interface 1 * RJ45 LAN Port Auto-negotiation, Auto MDI/MDIX Ethernet Standards Ethernet specification IEEE802.3, IEEE802.3u, IEEE802.3x AC Input 100 - 240VAC, 50-60 Hz, 0.8A(maximum) Operating Temperature 0 ° C to 45 ° C Storage Temperature -25° C to 70° C Operating 10-90%RH (max) 56.9 Page 8 Humidity Certifications FCC Part 15 Class B Safety Approvals UL Listed (UL60950-1)/cUL CSA No.22- 60950-01-03 Page 9 FCC Information to User This device complies with part 15 FCC rules. Operation is subject to the following two conditions: (1)this device may not cause harmful interference (2)this device must accept any interference received, including interference that may cause undesired operations. FCC Information to User This device complies with part 15 FCC rules. Operation is subject to the following two conditions: (1)this device may not cause harmful interference (2)this device must accept any interference received, including interference that may cause undesired operations. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Note: The country code selection is for non-US model only and is not available to all US model. Per FCC regulation, all WiFi product marketed in US must fixed to US operation channels only.
SerComm Corporation中磊電子股份有限公司 Taipei Office: 8F, No.3-1, YuanQu St., NanKang, Taipei 115, Taiwan, R.O.C. TEL: 886-2-2655-3988 FAX: 886-2-2655-3966 Date:2013/09/06 Declaration for no non-US channel operation We, SerComm Corp. declare that the device does not support any non-US channels in all the operational mode(s) for the following product. FCC ID: P27RP131 If you should have any question(s) regarding this declaration, please don’t hesitate to contact us. Thank you! Sep.,06,2013 ----------------------------------------------------- SerComm Corporation Angus Chang/ Manager TEL: 886-2-2655-3988*2598 FAX: 886-2-2655-3965 E-mail: [email protected]
SerComm Corporation中磊電子股份有限公司 Taipei Office: 8F, No.3-1, YuanQu St., NanKang, Taipei 115, Taiwan, R.O.C. TEL: 886-2-2655-3988 FAX: 886-2-2655-3966 Date:2013/09/06 FCC ID: P27RP131 Federal Communications Commission Authorization and Evaluation Division Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, the Applicant hereby requests confidential treatment of information accompanying this Application as outlined below: Schematics Block Diagram The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457, disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Sep., 06-2013 ----------------------------------------------------- SerComm Corporation Angus Chang/ Manager TEL: 886-2-2655-3988*2598 FAX: 886-2-2655-3965 E-mail: [email protected]
SerComm Corporation中磊電子股份有限公司 Taipei Office: 8F, No.3-1, YuanQu St., NanKang, Taipei 115, Taiwan, R.O.C. TEL: 886-2-2655-3988 FAX: 886-2-2655-3966 Date:2013/09/06 Authorization Letter To whom it may concern: We, the undersigned SerComm Corp. hereby authorize Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch (BV CPS Taoyuan) of Taiwan to act on our behalf in all matters relating to all processes required in FCC Approval and any communication needed with the national authority. Any and all acts carried out by BV CPS Taoyuan on our behalf shall have the same effects as acts of our own. If you have any questions regarding the authorization, please don’t hesitate to contact us. Thank you! Sincerely yours, Sep.,06-2013 ----------------------------------------------------- SerComm Corporation Angus Chang/ Manager TEL: 886-2-2655-3988*2598 FAX: 886-2-2655-3965 E-mail: [email protected]
Page 1 CONSTRUCTION PHOTOS OF EUT Page 2
Label Location 單位用量x1
Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12
FCC ID: P27RP131 Report No.: RF130808D11 Operational Description This device is a Wireless PoE Adapter, which operates in the 2.4GHz frequency spectrum with throughput of up to 300Mbps which OFDM technique will be applied. If the signal to noise ratio is too poor which could not support 300Mbps, the 11Mbps data rate with DSSS technique will be applied. The transmitter of the EUT is powered by AC adapter. The antenna used in this product is Printed antenna without connector. The other instruction, please have a look at the users manual.
Report No.: SA130808D11 1 of 6 Report Format Version 5.0.0 RF EXPOSURE REPORT REPORT NO.: SA130808D11 MODEL NO.: RP131 FCC ID: P27RP131 RECEIVED: Aug. 8, 2013 TESTED: Aug. 15 ~ 22, 2013 ISSUED: Aug. 28, 2013 APPLICANT: SerComm Corp. ADDRESS: 8F,No.3-1,YuangQu St.,NanKang,Taipei 115,Taiwan ,R.O.C. ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch LAB ADDRESS: No. 47, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan, R.O.C. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. Report No.: SA130808D11 2 of 6 Report Format Version 5.0.0 TABLE OF CONTENTS RELEASE CONTROL RECORD ................................................................................ 3 1. CERTIFICATION ........................................................................................... 4 2. RF EXPOSURE LIMIT .................................................................................. 5 3. MPE CALCULATION FORMULA .................................................................. 5 4. CLASSIFICATION ......................................................................................... 5 5. CALCULATION RESULT OF MAXIMUM CONDUCTED POWER ............... 6 Report No.: SA130808D11 3 of 6 Report Format Version 5.0.0 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED SA130808D11 Original release Aug. 28, 2013 Report No.: SA130808D11 4 of 6 Report Format Version 5.0.0 1. CERTIFICATION PRODUCT: Wireless PoE Adapter MODEL NO.: RP131 BRAND: SerComm APPLICANT: SerComm Corp. TESTED: Aug. 15 ~ 22, 2013 TEST SAMPLE: ENGINEERING SAMPLE STANDARDS: FCC Part 2 (Section 2.1091) FCC OET Bulletin 65, Supplement C (01-01) IEEE C95.1 The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC characteristics under the conditions specified in this report. PREPARED BY : , DATE:Aug. 28, 2013 ( Annie Chang / Supervisor ) APPROVED BY : , DATE:Aug. 28, 2013 ( Ken Liu / Senior Manager ) Report No.: SA130808D11 5 of 6 Report Format Version 5.0.0 2. RF EXPOSURE LIMIT LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) FREQUENCY RANGE (MHz) ELECTRIC FIELD STRENGTH (V/m) MAGNETIC FIELD STRENGTH (A/m) POWER DENSITY (mW/cm 2 ) AVERAGE TIME (minutes) LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE 300-1500 ... ... F/1500 30 1500-100,000 ... ... 1.0 30 F = Frequency in MHz 3. MPE CALCULATION FORMULA Pd = (Pout*G) / (4*pi*r2) where Pd = power density in mW/cm2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm 4. CLASSIFICATION The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. So, this device is classified as Mobile Device. Report No.: SA130808D11 6 of 6 Report Format Version 5.0.0 5. CALCULATION RESULT OF MAXIMUM CONDUCTED POWER FREQUENCY BAND (MHz) MAX POWER (dBm) ANTENNA GAIN (dBi) DISTANCE (cm) POWER DENSITY (mW/cm 2 ) LIMIT (mW/cm 2 ) 2412 ~ 2462 29.22 4.35 20 0.4526 1.00 --- END ---
Report No.: RF130808D11 1 of 55 Report Format Version 5.2.0 FCC TEST REPORT REPORT NO.: RF130808D11 MODEL NO.: RP131 FCC ID: P27RP131 RECEIVED: Aug. 8, 2013 TESTED: Aug. 15 ~ 22, 2013 ISSUED: Aug. 28, 2013 APPLICANT: SerComm Corp. ADDRESS: 8F,No.3-1,YuangQu St.,NanKang,Taipei 115,Taiwan ,R.O.C. ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch LAB ADDRESS: No. 47, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan, R.O.C. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the com pliance or non-compliance to the specification. This report should not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. Report No.: RF130808D11 2 of 55 Report Format Version 5.2.0 TABLE OF CONTENTS RELEASE CONTROL RECORD ................................................................................ 4 1. CERTIFICATION .............................................................................................. 5 2. SUMMARY OF TEST RESULTS ..................................................................... 6 2.1 MEASUREMENT UNCERTAINTY ................................................................... 6 3. GENERAL INFORMATION .............................................................................. 7 3.1 GENERAL DESCRIPTION OF EUT ................................................................ 7 3.2 DESCRIPTION OF TEST MODES .................................................................. 8 3.2.1 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL ................... 9 3.3 DESCRIPTION OF SUPPORT UNITS .......................................................... 11 3.3.1 CONFIGURATION OF SYSTEM UNDER TEST ............................................ 11 3.4 GENERAL DESCRIPTION OF APPLIED STANDARDS ................................ 12 4. TEST TYPES AND RESULTS ....................................................................... 13 4.1 RADIATED EMISSION AND BANDEDGE MEASUREMENT ........................ 13 4.1.1 LIMITS OF RADIATED EMISSION AND BANDEDGE MEASUREMENT ...... 13 4.1.2 TEST INSTRUMENTS ................................................................................... 14 4.1.3 TEST PROCEDURES ................................................................................... 15 4.1.4 DEVIATION FROM TEST STANDARD .......................................................... 15 4.1.5 TEST SETUP ................................................................................................. 16 4.1.6 EUT OPERATING CONDITIONS .................................................................. 16 4.1.7 TEST RESULTS ............................................................................................ 17 4.2 CONDUCTED EMISSION MEASUREMENT ................................................. 30 4.2.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT .............................. 30 4.2.2 TEST INSTRUMENTS ................................................................................... 30 4.2.3 TEST PROCEDURES ................................................................................... 31 4.2.4 DEVIATION FROM TEST STANDARD .......................................................... 31 4.2.5 TEST SETUP ................................................................................................. 32 4.2.6 EUT OPERATING CONDITIONS .................................................................. 32 4.2.7 TEST RESULTS ............................................................................................ 33 4.3 6dB BANDWIDTH MEASUREMENT ............................................................. 35 4.3.1 LIMITS OF 6dB BANDWIDTH MEASUREMENT .......................................... 35 4.3.2 TEST SETUP ................................................................................................. 35 4.3.3 TEST INSTRUMENTS ................................................................................... 35 4.3.4 TEST PROCEDURE ...................................................................................... 35 4.3.5 DEVIATION FROM TEST STANDARD .......................................................... 35 4.3.6 EUT OPERATING CONDITIONS .................................................................. 35 4.3.7 TEST RESULTS ............................................................................................ 36 4.4 CONDUCTED OUTPUT POWER .................................................................. 37 4.4.1 LIMITS OF CONDUCTED OUTPUT POWER MEASUREMENT ................... 37 Report No.: RF130808D11 3 of 55 Report Format Version 5.2.0 4.4.2 TEST SETUP ................................................................................................. 37 4.4.3 TEST INSTRUMENTS ................................................................…
Text truncated - open the document above for the full version.
1 of 2 PHOTOGRAPHS OF THE TEST CONFIGURATION CONDUCTED EMISSION TEST 2 of 2 RADIATED EMISSION TEST
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 835.00 mW |
WIRELESS PIR MOTION SENSOR
Equipment Class
DTS - Digital Transmission SystemMoso Canopy 5GOD2
Equipment Class
CBD - Citizens Band Category A and B DevicesCATM1 Module
Equipment Class
PCB - PCS Licensed TransmitterMqio 9W
Equipment Class
DTS - Digital Transmission SystemMachineQ Area 8C V2 LoRaWAN Gateway
Equipment Class
PCB - PCS Licensed Transmitter