FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

ยฉ 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Sercomm Corporation/
  3. P27SZSRN02SA

P27SZSRN02SAZigBee Safeawake Siren Repeater

Sercomm Corporation
ZigBee Safeawake Siren Repeater - FCC ID P27SZSRN02SA - Sercomm Corporation
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Nov 18, 2013
Application Purpose
Original Equipment
Date of Application
Nov 18, 2013
Equipment Note
ZigBee Safeawake Siren Repeater
Frequency Range
2405.00000000 - 2480.00000000
Company
Sercomm Corporation
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

โ†—

Attestation Statements

โ†—

Cover Letter(s)

โ†—
โ†—

External Photos

โ†—

ID Label/Location Info

โ†—

Internal Photos

โ†—

Operational Description

โ†—

RF Exposure Info

โ†—

Test Report

โ†—

Test Setup Photos

โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 SZ-SRN02-SA ZigBee Safeawake Siren Repeater Installation Guide The SZ-SRN02-SA indoor Safeawake Siren Repeater can function as an alarm siren and work with the existing traditional smoke alarm to provide more protection. When a smoke alarm sends out a 0.5 second T3 pattern, the SZ-SRN02-SA will hear and be triggered instantly. Furthermore, this device extends the range of your Home Security system's wireless network to ensure that signals from the other devices reach the coordinator Specification Frequency 2.4GHz Batter Type CR123A x 2 RF Communication Range Open Air: 150M (Max.) Power Source 100 - 240VAC Operating Temperature 0ยฐ C to 50ยฐ C (32ยฐ - 122ยฐF) Storage Temperature -20ยฐ C to 70ยฐ C (-4ยฐ - 158ยฐF) Backup Battery Life 24 Hours Internal Sounder Output At least 85 dB at 3 meters Dimension 126mm x 80mm x 39mm (4.96" x 3.15" x 1.54") Package Contents 2 Intallation Pre-Intallation 1. Remove the battery cover of the device. 2. Install the supplied two CR123A batteries correctly. Note: For safety reason, please replace the backup CR123A batteries after the siren has been triggered (except self-testing). Operation Power Status LED (Green/Amber) On (Green) - AC power mode. On (Amber) - DC battery mode. Blinking (Amber) - Low battery mode. 3 1. Join Function For "Join" a network, please do the following instruction: โ€ข Set the ZigBee Coordinator into โ€œPermit-Joiningโ€ mode. โ€ข Press the Join/Leave button for less than 1 second. The Join/Leave LED is blinking while processing. If the siren has been joined with the coordinator successfully, the Join/Leave LED will be on for 2 seconds and then off. The Join/Leave LED will be off instantly if failed. 2. Leave Function For "Leave" a network, please do the following instruction: โ€ข Press Join/Leave button for 3 seconds to let the siren disassociate from the coordinator. The Join/Leave LED will be on for 1 second and then off. 3. Test Function โ€ข Remove the battery cover before testing. โ€ข Press the Test button for 3 seconds. When pressing the Test button, the device will generate low level sounds and flash light to indicate that the siren is serviceable. Note: โ€ข The Join/Leave LED will stay off during the normal operation. โ€ข The siren is equipped with a tamper switch. If the device is removed, the siren will send an alarm message to the ZigBee coordinator. โ€ข For safety reason, please replace the backup CR123A batteries after the siren has been triggered (except self-testing). Procedure 1. Remove the screw of the outletโ€™s cover plate. Plug the device into the 110V outlet. Note: Make sure that the outlet is not controlled by a wall switch. 2. Tighten the device to the outlet with the supplied screw. The supplied washer can be used as a spacer between the screw and the outlet, if required. 4 Repeater Setup The siren can also be used as a repeater that lets you extend the security range of your home. When using the device as a repeater, just locate it in a suitable place, which has average signal strength and is at the halfway between the coordinator and the furthest sensor. The repeater can even boost signals weakened by walls and other obstructions. 5 FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: โ€ข Reorient or relocate the receiving antenna. โ€ข Increase the separation between the equipment and receiver. โ€ข Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. โ€ข Consult the dealer or an experienced radio/TV technician for help. To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. (Example - use only shielded interface cables when connecting to computer or peripheral devices). FCC Radiation Exposure Statement This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

Attestation Statements

SerComm Corporationไธญ๏ฅ‡้›ปๅญ่‚กไปฝๆœ‰้™ๅ…ฌๅธ Taipei Office: 8F, No.3โ€1, YuanQu St., NanKang, Taipei 115, Taiwan, R.O.C. TEL: 886โ€2โ€2655โ€3988 FAX: 886โ€2โ€2655โ€3966 Date:2013/11/07 Declaration for no nonโ€US channel operation We, SerComm Corp. declare that the device does not support any nonโ€US channels in all the operational mode(s) for the following product. FCC ID: P27SZSRN02SA If you should have any question(s) regarding this declaration, please donโ€™t hesitate to contact us. Thank you! Nov., 07-2013 โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€ SerComm Corporation Angus Chang/ Manager TEL: 886โ€2โ€2655โ€3988*2598 FAX: 886โ€2โ€2655โ€3965 Eโ€mail: [email protected]

Cover Letter(s)

SerComm Corporationไธญ๏ฅ‡้›ปๅญ่‚กไปฝๆœ‰้™ๅ…ฌๅธ Taipei Office: 8F, No.3โ€1, YuanQu St., NanKang, Taipei 115, Taiwan, R.O.C. TEL: 886โ€2โ€2655โ€3988 FAX: 886โ€2โ€2655โ€3966 Date:2013/11/07 FCC ID: P27SZSRN02SA Federal Communications Commission Authorization and Evaluation Division Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commissionโ€™s Rules, the Applicant hereby requests confidential treatment of information accompanying this Application as outlined below: Schematics Block Diagram The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457, disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Nov., 07-2013 โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€ SerComm Corporation Angus Chang/ Manager TEL: 886โ€2โ€2655โ€3988*2598 FAX: 886โ€2โ€2655โ€3965 Eโ€mail: [email protected]

Cover Letter(s)

SerComm Corporationไธญ๏ฅ‡้›ปๅญ่‚กไปฝๆœ‰้™ๅ…ฌๅธ Taipei Office: 8F, No.3โ€1, YuanQu St., NanKang, Taipei 115, Taiwan, R.O.C. TEL: 886โ€2โ€2655โ€3988 FAX: 886โ€2โ€2655โ€3966 Date:2013/11/07 Authorization Letter To whom it may concern: We, the undersigned SerComm Corp. hereby authorize Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch (BV CPS Taoyuan) of Taiwan to act on our behalf in all matters relating to all processes required in FCC Approval and any communication needed with the national authority. Any and all acts carried out by BV CPS Taoyuan on our behalf shall have the same effects as acts of our own. If you have any questions regarding the authorization, please donโ€™t hesitate to contact us. Thank you! Sincerely yours, Nov., 07-2013 โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€โ€ SerComm Corporation Angus Chang/ Manager TEL: 886โ€2โ€2655โ€3988*2598 FAX: 886โ€2โ€2655โ€3965 Eโ€mail: [email protected]

External Photos

Page 1 CONSTRUCTION PHOTOS OF EUT

ID Label/Location Info

Label Location ๅ–ฎไฝ็”จ้‡x1

Internal Photos

Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8

Operational Description

FCC ID: P27SZSRN02SA Report No.: RF131029D16 Operational Description This device is a ZigBee Safeawake Siren Repeater with built-in a Zigbee module. This device is a ZigBee Safeawake Siren Repeater, which operates in the 2.4GHz frequency spectrum with throughput of up to 2Mbps which OQPSK technique will be applied. The transmitter of the EUT is powered by AC 120V, 60Hz or DC 6V. The antenna used in this product is PCB antenna. The other instruction, please have a look at the users manual.

RF Exposure Info

Report No.: SA131029D16 1 of 6 Report Format Version 5.0.0 RF EXPOSURE REPORT REPORT NO.: SA131029D16 MODEL NO.: SZ-SRN02xxxxxxxx, SZ-SRN02-SA FCC ID: P27SZSRN02SA RECEIVED: Oct. 29, 2013 TESTED: Oct. 31 ~ Nov. 1, 2013 ISSUED: Nov. 6, 2013 APPLICANT: SerComm Corp. ADDRESS: 8F,No.3-1,YuangQu St.,NanKang,Taipei 115,Taiwan ,R.O.C.(NanKang Software Park) ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch LAB ADDRESS: No. 47, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan, R.O.C. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. This report should not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. Report No.: SA131029D16 2 of 6 Report Format Version 5.0.0 TABLE OF CONTENTS RELEASE CONTROL RECORD ................................................................................. 3 1. CERTIFICATION ........................................................................................... 4 2. RF EXPOSURE LIMIT ................................................................................... 5 3. MPE CALCULATION FORMULA .................................................................. 5 4. CLASSIFICATION ......................................................................................... 5 5. CALCULATION RESULT OF MAXIMUM CONDUCTED POWER ................ 6 Report No.: SA131029D16 3 of 6 Report Format Version 5.0.0 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED SA131029D16 Original release Nov. 6, 2013 Report No.: SA131029D16 4 of 6 Report Format Version 5.0.0 1. CERTIFICATION PRODUCT: ZigBee Safeawake Siren Repeater MODEL NO.: SZ-SRN02xxxxxxxx, SZ-SRN02-SA (The โ€œxโ€ in model name can be 0 to 9, A to Z, blank or โ€œ- โ€œ for marking purpose) BRAND NAME: Sercomm, iControl, Comcast, Time Warner Cable, Cox, Rogers, Brighthouse, Comporium, Rock Hill APPLICANT: SerComm Corp. TESTED: Oct. 31 ~ Nov. 1, 2013 TEST SAMPLE: ENGINEERING SAMPLE STANDARDS: FCC Part 2 (Section 2.1091) FCC OET Bulletin 65, Supplement C (01-01) IEEE C95.1 The above equipment (model no.: SZ-SRN02-SA) has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sampleโ€™s EMC characteristics under the conditions specified in this report. PREPARED BY : , DATE: Nov. 6, 2013 ( Celia Chen / Senior Specialist ) APPROVED BY : , DATE: Nov. 6, 2013 ( Rex Lai / Assistant Manager ) Report No.: SA131029D16 5 of 6 Report Format Version 5.0.0 2. RF EXPOSURE LIMIT LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) FREQUENCY RANGE (MHz) ELECTRIC FIELD STRENGTH (V/m) MAGNETIC FIELD STRENGTH (A/m) POWER DENSITY (mW/cm 2 ) AVERAGE TIME (minutes) LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE 300-1500 ... ... F/1500 30 1500-100,000 ... ... 1.0 30 F = Frequency in MHz 3. MPE CALCULATION FORMULA Pd = (Pout*G) / (4*pi*r2) where Pd = power density in mW/cm2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm 4. CLASSIFICATION The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. So, this device is classified as Mobile Device. Report No.: SA131029D16 6 of 6 Report Format Version 5.0.0 5. CALCULATION RESULT OF MAXIMUM CONDUCTED POWER FREQUENCY BAND (MHz) MAX POWER (dBm) ANTENNA GAIN (dBi) DISTANCE (cm) POWER DENSITY (mW/cm 2 ) LIMIT (mW/cm 2 ) 2405-2480 19.61 1.56 20 0.0260 1.00 --- END ---

Test Report

Report No.: RF131029D16 1 of 38 Report Format Version 5.2.0 FCC TEST REPORT REPORT NO.: RF131029D16 MODEL NO.: SZ-SRN02xxxxxxxxโ€“ multiple listing see item 3.1 FCC ID: P27SZSRN02SA RECEIVED: Oct. 29, 2013 TESTED: Oct. 31 ~ Nov. 1, 2013 ISSUED: Nov. 6, 2013 APPLICANT: SerComm Corp. ADDRESS: 8F,No.3-1,YuangQu St.,NanKang,Taipei 115,Taiwan ,R.O.C.(NanKang Software Park) ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch LAB ADDRESS: No. 47, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan, R.O.C. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. This report should not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. Report No.: RF131029D16 2 of 38 Report Format Version 5.2.0 TABLE OF CONTENTS RELEASE CONTROL RECORD................................................................................ 4 1. CERTIFICATION ............................................................................................. 5 2. SUMMARY OF TEST RESULTS ..................................................................... 6 2.1 MEASUREMENT UNCERTAINTY .................................................................. 6 3. GENERAL INFORMATION ............................................................................. 7 3.1 GENERAL DESCRIPTION OF EUT ................................................................ 7 3.2 DESCRIPTION OF TEST MODES .................................................................. 8 3.2.1 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL .................. 9 3.3 DUTY CYCLE OF TEST SIGNAL.................................................................. 11 3.4 DESCRIPTION OF SUPPORT UNITS .......................................................... 12 3.4.1 CONFIGURATION OF SYSTEM UNDER TEST ........................................... 12 3.5 GENERAL DESCRIPTION OF APPLIED STANDARDS ............................... 13 4. TEST TYPES AND RESULTS ....................................................................... 14 4.1 RADIATED EMISSION AND BANDEDGE MEASUREMENT ........................ 14 4.1.1 LIMITS OF RADIATED EMISSION AND BANDEDGE MEASUREMENT ..... 14 4.1.2 TEST INSTRUMENTS .................................................................................. 15 4.1.3 TEST PROCEDURES ................................................................................... 16 4.1.4 DEVIATION FROM TEST STANDARD ......................................................... 16 4.1.5 TEST SETUP ................................................................................................ 17 4.1.6 EUT OPERATING CONDITIONS .................................................................. 17 4.1.7 TEST RESULTS ............................................................................................ 18 4.2 CONDUCTED EMISSION MEASUREMENT ................................................ 22 4.2.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT .............................. 22 4.2.2 TEST INSTRUMENTS .................................................................................. 22 4.2.3 TEST PROCEDURES ................................................................................... 23 4.2.4 DEVIATION FROM TEST STANDARD ......................................................... 23 4.2.5 TEST SETUP ................................................................................................ 24 4.2.6 EUT OPERATING CONDITIONS .................................................................. 24 4.2.7 TEST RESULTS ............................................................................................ 25 4.3 6dB BANDWIDTH MEASUREMENT ............................................................ 27 4.3.1 LIMITS OF 6dB BANDWIDTH MEASUREMENT .......................................... 27 4.3.2 TEST SETUP ................................................................................................ 27 4.3.3 TEST INSTRUMENTS .................................................................................. 27 4.3.4 TEST PROCEDURE ..................................................................................... 27 4.3.5 DEVIATION FROM TEST STANDARD ......................................................... 27 4.3.6 EUT OPERATING CONDITIONS .................................................................. 27 4.3.7 TEST RESULTS ............................................................................................ 28 4.4 CONDUCTED OUTPUT POWER ................................................................. 29 4.4.1 LIMITS OF CONDUCTED OUTPUT POWER MEASUREMENT .................. 29 Report No.: RF131029D16 3 of 38 Report Format Version 5.2.0 4.4.2 TEST SETUP .......................................โ€ฆ

Text truncated - open the document above for the full version.

Test Setup Photos

1 of 2 PHOTOGRAPHS OF THE TEST CONFIGURATION CONDUCTED EMISSION TEST 2 of 2 RADIATED EMISSION TEST

Contact Information

Applicant

Nick Wu(Engineer)
[email protected]886-2-2655-3988Fax: 886-2-2655-3965

Test Firm

Bureau Veritas CPS (H.K.) Ltd., Taoyuan BranchRichard Chen
[email protected]+886-3-2600884Fax: +886-3-2115834

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz91.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted. End users and installers must be provided with operating and installation instructions to ensure RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product guidelines.

Other Applications from Sercomm Corporation

P27-MOTIONZW60R0

WIRELESS PIR MOTION SENSOR

Aug 04, 2026

Equipment Class

DTS - Digital Transmission System
P27-SCP5173P

Moso Canopy 5GOD2

Dec 24, 2025

Equipment Class

CBD - Citizens Band Category A and B Devices
P27-TPM530

CATM1 Module

Nov 24, 2025

Equipment Class

PCB - PCS Licensed Transmitter
P27MQIO

Mqio 9W

Sep 16, 2025

Equipment Class

DTS - Digital Transmission System
P27LORAAREAV2

MachineQ Area 8C V2 LoRaWAN Gateway

Jul 25, 2024

Equipment Class

PCB - PCS Licensed Transmitter