P4O9MK74946931Remote Keyless Entry

VAST LLC
Remote Keyless Entry - FCC ID P4O9MK74946931 - VAST LLC
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Sep 04, 2012
Application Purpose
Original Equipment
Date of Application
Aug 30, 2012
Equipment Note
Remote Keyless Entry
Frequency Range
314.90000000 - 314.90000000
Company
VAST LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Annex no. 5 User Manual Statements m. dudde hochfrequenz-technik Rottland 5a, D-51429 Bergisch-Gladbach DIN EN ISO/IEC 17025 certified DAkkS accreditation number: D-PL-12053-01 Tel. : +49 22 07 - 96 89 - 0 Fax : +49 22 07 - 96 89 - 20 email: [email protected] www.dudde.com Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Date: 2012-08-20 Brand/Trade name: VAST Model name: 9MK74946931 FCC Certification Number: P4O9MK74946931 IC Certification Number: 10575A-9MK74946931 Subject: Compliance Statements in the User’s Manual Dear Sirs, On behalf of our customer VAST LLC we declare that they ensure that the following will be included in a prominent location of the owner’s manual of the car: The title “CAUTION TO USERS” or “FCC/IC WARNING NOTE” or relevant title and “Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.” This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prĂ©sent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisĂ©e aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioĂ©lectrique subi, mĂŞme si le brouillage est susceptible d'en compromettre le fonctionnement. Yours sincerely, m. dudde hochfrequenz-technik Andreas Morsbach Assistant Manager

External Photos

Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Annex no. 1 External Photographs Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920

ID Label/Location Info

Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Annex no. 4 Label Sample Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Label sample VAST LLC Model: 9MK74946931 FCC ID: P4O9MK74946931 IC: 10575A-9MK74946931 Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Label location VAST LLC Model: 9MK74946931 FCC ID: P4O9MK74946931 IC: 10575A-9MK74946931

Internal Photos

Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Annex no. 2 Internal Photographs Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920

Test Report

Test report no. 12007891 Page 1 of 34 EUT: 9MK74946931 FCC ID: P4O9MK74946931 Date of issue: 2012-08-13 Date: 2012-02-14 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Test Report acc. to FCC Title 47 CFR Part 15 relating to VAST LCC 9MK74946931 Title 47 - Telecommunication Part 15 - Radio Frequency Devices Subpart C – Intentional Radiators Measurement Procedure: ANSI C63.4-2009 Test report no. 12007891 Page 2 of 34 EUT: 9MK74946931 FCC ID: P4O9MK74946931 Date of issue: 2012-08-13 Date: 2012-02-14 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Manufacturer’s details Manufacturer VAST LCC Manufacturer’s grantee code P4O Manufacturer’s address VAST LCC 3333 West Good Hope Road 53209 Milwaukee United States of America Phone: +49 (0) 2051 498 7373 Fax: +49 (0) 2051 498 787373 Email: [email protected] Relevant standard used 47 CFR Part 15C - Intentional Radiators ANSI C63.4-2009 Test Report prepared by Technical engineer Ralf Trepper m. dudde hochfrequenz-technik (laboratory) Rottland 5a 51429 Bergisch Gladbach Germany Phone: +49 2207 96890 Fax: +49 2207 968920 Email: [email protected] Equipment Under Test (EUT) Equipment category RF transmitter Trade name VAST Type designation 9MK74946931 Serial no. --- Variants --- Test report no. 12007891 Page 3 of 34 EUT: 9MK74946931 FCC ID: P4O9MK74946931 Date of issue: 2012-08-13 Date: 2012-02-14 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 1. Test result summary Clause Requirements headline Test result Report page number 8.1 Antenna requirement Pass Fail N.t.* 9 8.2 Conducted limits Pass Fail N.t.* 10 to 13 8.3 Restricted bands of operation Pass Fail N.t.* 14 to 16 8.4 Radiated emission limits, general requirements Pass Fail N.t.* 17 to 22 8.5 Periodic operation characteristics Pass Fail N.t.* 23 to 24 8.6 Fundamental frequencies / Field strength limits Pass Fail N.t.* 25 to 30 8.7 Bandwidth (20 dB) Pass Fail N.t.* 31 to 32 * Not tested The equipment meets the requirements Yes No Signature: ............................. Signature: ............................. (Technician) (Manager) Test report no. 12007891 Page 4 of 34 EUT: 9MK74946931 FCC ID: P4O9MK74946931 Date of issue: 2012-08-13 Date: 2012-02-14 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Table of contents 1. Test result summary .......................................................................................................................................... 3 2. Introduction ...................................................................................................................................................... 5 3. Testing laboratory ............................................................................................................................................ 5 4. Applicant .......................................................................................................................................................... 6 5. Product and product documentation ................................................................................................................ 6 6. Conclusions, observations and comments ........................................................................................................ 7 7. Operational description ...................................................................................................................................... 8 8.1 Antenna requirement ....................................................................................................................................... 9 8.1.1 Regulation ............................................................................................................................................. 9 8.1.2 Result .................................................................................................................................................... 9 8.2 Conducted limits ............................................................................................................................................ 10 8.2.1 Regulation ............................................................................................................................................. 10 8.1.2 Test equipment ...................................................................................................................................... 11 8.2.3 Test procedures ..................................................................................................................................... 11 8.2.4 Result .................................................................................................................................................... 12 8.3 Restricted bands of operation ........................................................................................................................... 13 8.3.1 Regulation ............................................................................................................................................. 13 8.3.2 Result .................................................................................................................................................... 15 8.4 Radiated emission limits, general requirements ................................................................................................ 16 8.4.1 Regulation ............................................................................................................................................. 16 8.4.2 Test equipment ...................................................................................................................................... 17 8.4.…

Text truncated - open the document above for the full version.

Test Report

Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Annex no. 3 Occupied Bandwidth Plot Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 20 dB Bandwidth Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 99 % Bandwidth

Test Report

Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Annex no. 11 Periodic Operation Characteristics Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Part 15.231(a) (1) A manually operated transmitter shall employ a switch that will automatically deactivate the transmitter within not more than 5 seconds of being released. Open button T1 = release point Close button T1 = release point Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Trunk button T1 = release point Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 One pulse train, worst case in a 100 ms time range (For all buttons the same) Open button (One pulse train) Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Close button (One pulse train) Trunk button (One pulse train) Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Worst Case The pulse train consists: one single pulse of 1.014 ms single pulses of 33.478 ms The measured worst case duration for a single pulse transmission in any 100ms time window is 34.492 ms. Maximum transmitting duration in every 100ms period: 34.347 ms Averaging factor = 20*log(34.492 /100)= -9.2 dB

Test Setup Photos

Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Annex no. 6 Test Setup Photographs Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920

Contact Information

Applicant

Joerg Donnerstag(Dipl.-Ing.)
[email protected]0049 2051 498 7373Fax: 004902051787373

Technical Contact

WITTE-Velbert GmbH & Co. KGJoerg Donnerstag
[email protected]

Germany

Test Firm

m. dudde hochfrequenz-technikManfred Dudde
[email protected]49-2207-9689-0Fax: 49-2207-9689-20

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231314.9 MHz - 314.9 MHz-
Confidentiality
Long Term