FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Lida Toys (Jinjiang) Co., Ltd./
  3. P528929

P528929Remote Control Toy Transmitter

Lida Toys (Jinjiang) Co., Ltd.
Remote Control Toy Transmitter - FCC ID P528929 - Lida Toys (Jinjiang) Co., Ltd.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Jan 30, 2002
Application Purpose
Original Equipment
Date of Application
Jan 30, 2002
Equipment Note
Remote Control Toy Transmitter
Frequency Range
49.86000000 - 49.86000000
Company
Lida Toys (Jinjiang) Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Operational Description

↗

Schematics

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

External Photos

FCC ID: P528929 PHOTOGRAPH OF THE PRODUCT FRONT VIEW OF THE PRODUCT REAR VIEW OF THE PRODUCT

ID Label/Location Info

FCC ID: P528929 MADE IN CHINA This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

ID Label/Location Info

FCC ID: P528929 LABEL LOCATION BOTTOM VIEW OF THE DEVICE WITH FCC ID LABEL Label

Internal Photos

FCC ID: P528929 PHOTOGRAPH OF THE PRODUCT INNER CIRCUIT TOP VIEW INNER CIRCUIT BOTTOM VIEW

Operational Description

FCC ID:P528929 Circuit Description The 49.86MHz crystal oscillator drives the base of Q9018 the final/buffer amplifier. The modulation provided by Q9014. The output of has the matching network consisting of L2.2ìH that limit the harmonic content and effect the proper coupling of the antenna to the output stage. Antenna, Ground and Power Source The antenna consists of a 27cm long Metal Wire. There is no external ground connection. The ground is only that of the printed circuit board. Electric current is supplied by a 9 Volt (“6F22” size battery x 1) primary battery

Test Report

Date: 2002-01-10 TEST REPORT Page 1 of 22 No.: HM105911 FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER TEST REPORT No.:HM105911 Equipment Under Test [EUT]:Robot Gladiator Model Number:8929 Applicant:Lida Toys (Jinjiang) Co., Ltd. FCC ID :P528929 Date: 2002-01-10 TEST REPORT Page 2 of 22 No.: HM105911 CONTENT: Cover Page 1 of 22 Content Page 2-3 of 22 Conclusion Page 4 of 22 1.0General Details 1.1Test Laboratory Page 5 of 22 1.2Applicant Details Page 5 of 22 Applicant HKSTC Code Number for Applicant Manufacturer 1.3Equipment Under Test [EUT] Page 6 of 22 Description of EUT operation 1.4Date of Order Page 6 of 22 1.5Submitted Sample Page 6 of 22 1.6Test Duration Page 6 of 22 1.7Country of Origin Page 6 of 22 1.8 Additional Information of EUT Page 7 of 22 2.0Technical Details 2.1Investigations Requested Page 8 of 22 2.2Test Standards and Results Summary Page 8 of 22 3.0Test Results 3.1Emission Page 9-14 of 22 3.2Bandwidth Measurement Page 15-17 of 22 Date: 2002-01-10 TEST REPORT Page 3 of 22 No.: HM105911 Appendix A List of Measurement Equipment Page 18 of 22 Appendix B Duty Cycle Correction During 100 msec Page 18-19 of 22 Appendix C Modification Method Page 20 of 22 Appendix D Photographs Page 21-22 of 22 Date: 2002-01-10 TEST REPORT Page 4 of 22 No.: HM105911 CONCLUSION The submitted product was deemed to have COMPLIED after modification with the requirements of Federal Communications Commission [FCC] Rules and Regulations Part 15. The tests were performed in accordance with the standards described above and on Section 2.2 in this Test Report. Verify byPatrick Wong for Chief Executive Date: 2002-01-10 TEST REPORT Page 5 of 22 No.: HM105911 1.0General Details 1.1Test Laboratory The Hong Kong Standards and Testing Centre Ltd. EMC Laboratory 10 Dai Wang Street, Taipo Industrial Estate New Territories, Hong Kong Telephone:852 2666 1888 Fax:852 2664 4353 1.2Applicant Details Applicant LIDA TOYS (JINJIANG) CO., LTD. Lida Industrial Bldg., 2 nd Industrial Area, Anhai, Jinjiang, Fujian, China Telephone:86 595 5709475 Fax:86 595 5709491 HKSTC Code Number for ApplicantLIT008 Manufacturer LIDA TOYS (JINJIANG) CO., LTD. Lida Industrial Bldg., 2 nd Industrial Area, Anhai, Jinjiang, Fujian, China Telephone:86 595 5709475 Fax:86 595 5709491 Date: 2002-01-10 TEST REPORT Page 6 of 22 No.: HM105911 1.3Equipment Under Test [EUT] Description of Sample Product:Robot Gladiator Manufacturer:Lida Toys (Jinjiang) Co., Ltd. Brand Name:LIDA Model Number:8929 Input Voltage:9Vd.c (“6F22” size battery x 1) 1.3.1Description of EUT Operation The Equipment Under Test(EUT) is an Lida Toys (Jinjiang) Co., Ltd., 49.86MHz Robot Gladiator. The transmitter is a 2 button transmitter. The EUT continues to transmit while button is being pressed. It is voice transmission, Modulation by Mic. and tape is frequency modulation. 1.4Date of Order 2001-09-20 1.5Submitted Sample(s): 1 Samples per model 1.6Test Duration 2001-11-20 1.7Country of Origin China Date: 2002-01-10 TEST REPORT Page 7 of 22 No.: HM105911 1.8Additional Information of EUT SubmittedNot Available User Manual Part List Circuit Diagram Printed Circuit Board [PCB] Layout Block diagram FCC ID Label Date: 2002-01-10 TEST REPORT Page 8 of 22 No.: HM105911 2.0Technical Details 2.1Investigations Requested Perform ElectroMagnetic Interference measurement in accordance with FCC 47CFR [Codes of Federal Regulations] Part 15 and ANSI C63.4:2000 for FCC Certification. 2.2Test Standards and Results Summary Tables EMISSION Results Summary Test ConditionTest RequirementTest MethodClass /Test Result SeverityPassFailedN/A Field Strength of Fundamental Emissions & Spurious Emissions FCC 47CFR 15.235ANSI C63.4:2000N/A Radiated Emissions, 30MHz to 1GHz FCC 47CFR 15.209ANSI C63.4:2000Class B Conducted Emissions on AC, 0.45MHz to 30MHz FCC 47CFR 15.207ANSI C63.4:2000Class B Note: N/A - Not Applicable Date: 2002-01-10 TEST REPORT Page 9 of 22 No.: HM105911 3.0Test Results 3.1Emission 3.1.1Radiated Emissions Test Requirement:FCC 47CFR 15.235 Test Method:ANSI C63.4:2000 Test Date:2001-11-20 Mode of Operation:On mode Test Method: The sample was placed 0.8m above the ground plane on the OATS *. Measurements in both horizontal and vertical polarities were performed. During the test, each emission was maximized by: having the EUT continuously working, investigate all operating modes, rotated about all 3 axis (X, Y & Z) to obtain worst position, manipulating interconnecting cables, rotating turntable, varying antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst-case are shown in Test Results of the following pages. *:OATS [Open Area Test Site] located at HKSTC with a metal ground plane on filed with the FCC pursuant to section 2.948 of the FCC rules, with Registration Number: 90657. Test Setup: EUT distance = 3m Pre -Amplifier Receiver Turn Table Computer Ground plane Date: 2002-01-10 TEST REPORT Page 10 of 22 No.: HM105911 Limits for Field Strength of Fundamental Emissions [FCC 47CFR 15.235]: Frequency Range of Fundamental Field Strength of Fundamental Emission [Peak] Field Strength of Fundamental Emission [Average] [MHz][μV/m][μV/m] 49.82-49.90100,00010,000 Results: Field Strength of Fundamental Emissions Peak Value FrequencyLevel @3mCorrection Factor Field Strength Field Strength Limit ** @3m Antenna Polarity MHzdBμVdB/mdBμV/mμV/mμV/m 49.8641.015.056.0630.9100,000Vertical According to FCC 47CFR15.35, the limit on the radio frequency emissions as measured using instrumentation with a peak detector function, corresponding to 20dB above the maximum permitted average limit for the frequency being investigated unless a different peak emission limit is otherwise specified in the rules. Remarks: *:Linear interpolations Correction Factor included Antenna Factor and Cable Attenuation. Calculated measurement uncertainty=30MHz to 300MHz±3.7dB 300MHz to 1GHz+3.0dB / -2.7dB Date: 2002-01-10 TEST REPORT Page 11 of 22 No.: HM105911 Results: Field …

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: P528929 TEST SET UP PHOTOGRAPH OF THE PRODUCT MEASUREMENT OF RADIATED EMISSION TEST SET UP

Contact Information

Applicant

Kwok Lee Fuk(Vice Factory Manager)
[email protected]86-595-5709475Fax: 86-595-5709491

Test Firm

Hong Kong Standards & Testing Cen.Wilson Wong
[email protected]852-2666-1888Fax: 852-2664-4353

Technical Specifications

#Rule PartsFrequency RangePower Output
115C49.86 MHz - 49.86 MHz-

Other Applications from Lida Toys (Jinjiang) Co., Ltd.

Remote Control Toy Transmitter - FCC ID P528927 - Lida Toys (Jinjiang) Co., Ltd.
P528927

Remote Control Toy Transmitter

Jan 30, 2002

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter