Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
RF Code Active RFID Tags: Features, Specifications, and Deployment Guidelines Publication P/N 00660 REV06 Active RFID Tags: Features, Specifications, and Deployment Guidelines 2 Trademarks RF Code™ and the RF Code logo are trademarks of RF Code, Inc. All other product names are copyright and registered trademarks or trade names of their respective owners. Information in this document is provided solely to enable system and software implementers to use RF Code products. There are no express or implied copyright licenses granted hereunder to design or fabricate any integrated circuits or integrated circuits based on the information in this document. RF Code reserves the right to make changes without further notice to any products herein. RF Code makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does RF Code assume any liability arising out of the application or use of any product, and specifically disclaims any and all liability, including without limitation consequential or incidental damages. The user of this system is cautioned that any changes or modifications to this system, not expressly approved by RF Code, Inc., could void the warranty. Copyright Statement Copyright © 2008-2014 RF Code, Inc. All Rights Reserved. This document, as well as the hardware and firmware described therein, are furnished under license and may only be used or copied in accordance with the terms of such license. The information in these pages are furnished for informational use only, are subject to change without notice, and should not be construed as a commitment by RF Code, Inc. RF Code assumes no responsibility or liability for any errors or inaccuracies that may appear in these pages. Every effort has been made to supply complete and accurate information. However, RF Code assumes no responsibility for its use, or for any infringements of patents or other rights of third parties, which would result. RF Code, Inc. 9229 Waterford Centre Blvd. Suite 500 Austin, TX 78758 www.rfcode.com Active RFID Tags: Features, Specifications, and Deployment Guidelines 3 Table of Contents TRADEMARKS .............................................................................................................................................................. 2 COPYRIGHT STATEMENT .................................................................................................................................................. 2 TABLE OF CONTENTS ........................................................................................................................................................ 3 REGULATORY AND COMPLIANCE INFORMATION ............................................................................................................. 4 INTRODUCTION AND OVERVIEW ..................................................................................................................................... 5 USING RF CODE TAGS IN DATA CENTERS ...................................................................................................................................... 6 GENERAL CLEANING PROCEDURES FOR RF CODE TAGS .................................................................................................................... 6 R-SERIES TAG FEATURES, SPECIFICATIONS, AND OPTIONS TABLE .................................................................................... 7 R-SERIES TAG – GENERAL USE AND DEPLOYMENT INSTRUCTIONS ................................................................................... 9 R100 IT ASSET TAG .................................................................................................................................................................. 9 R104-I IT ASSET TAG ................................................................................................................................................................ 9 R110 FLEX-MOUNT TAG ......................................................................................................................................................... 11 R114-I FLEX-MOUNT TAG ....................................................................................................................................................... 11 R120 DOOR TAG ................................................................................................................................................................... 13 R130 DRY CONTACT TAG AND R131 IR-ENABLED DRY CONTACT TAG ............................................................................................. 15 R135 FLUID DETECTOR TAG ..................................................................................................................................................... 16 R140 BADGE TAG .................................................................................................................................................................. 19 R142-I BADGE TAG ................................................................................................................................................................ 19 R150 TEMPERATURE TAG ........................................................................................................................................................ 21 R155/R156 HUMIDITY-TEMPERATURE TAG ............................................................................................................................... 22 R151 TETHERED TEMPERATURE SENSOR TAG .............................................................................................................................. 27 TEMPERATURE SENSOR ACCURACY AND PRECISION ....................................................................................................................... 28 TEMPERATURE SENSOR PERFORMANCE IN TYPICAL DATA CENTERS ......................................................................…
Text truncated - open the document above for the full version.
SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 5.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Project and Product Certification Representative Authorization Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Revised wording (obsolete) 1.0 2.0 Sept–25-2007 Updated company template (obsolete) 2.0 3.0 Jan-31-2012 Updated letter information (obsolete) 3.0 4.0 May-23-2014 Added FCC ID field (current) 4.0 5.0 Sept 16 2014 SCS-F18: Project and Product Certification Representative Authorization Letter Page 2 of 2 Rev 5.0 RF Code, Inc. 2015-4-13 To: SIEMIC, INC. 775 Montague Expressway, Milpitas, CA 95035 USA Dear Sir/Madam, Re: Product Certification Representative Authorization Letter We, RF Code, Inc. hereby authorize SIEMIC, Inc. to act as a Certification Body for certifying for the following project(s): Humidity-Temperature Tag, R156 FCC ID: P6FZ Sincerely, signature Mr Dale Parvey/ Director of Product Management E-mail: [email protected] Phone: 512-439-2240 Fax: (512) 439-2199 Address: 9229 Waterford Centre Blvd. Suite 500, Austin, Texas 78758- 7511, United States
SCS-F19: Confidentiality Request Letter Page 1 of 2 Rev 3.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Confidentiality Request Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Adding CFR 2.459 (obsolete) 1.0 2.0 August – 11 - 2008 Updated company template & Added text box (current) 2.0 3.0 Jan-31-2012 SCS-F19: Confidentiality Request Letter Page 2 of 2 Rev 3.0 RF Code, Inc. 2015-4-13 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Subject: Permanent Confidentiality Request for FCC ID: P6FZ We hereby request confidential treatment of information accompanying this application as outlined below: - Block Diagram - Schematics - Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, signature Mr Dale Parvey/ Director of Product Management E-mail: [email protected] Phone: 512-439-2240 Fax: (512) 439-2199 Address: 9229 Waterford Centre Blvd. Suite 500, Austin, Texas 78758- 7511, United States
Label Location Proposed Label Location on EUT
Lable Humidity‐Temperature Tag MODEL No.: R156 FCC ID: P6FZ IC: 4183A‐Z
module Antenna
TRF No.: FCC 15.231/A Page 1 of 21 Report No.: ES141225315E Ver. 1.0 Access to the World ELECTROMAGNETIC EMISSIONS COMPLIANCE REPORT INTENTIONAL RADIATOR CERTIFICATION TO FCC PART 15 SUBPART C REQUIREMENT T OF Humidity-Temperature Tag MODEL No.: R156 Trademark: N/A FCC ID: P6FZ REPORT NO: ES141225315E ISSUE DATE: April 13, 2015 Prepared for RF Code, Inc. 9229 Waterford Centre Blvd. Suite 500, Austin, TX 78758-7511, United States Prepared by SHENZHEN EMTEK CO., LTD Bldg 69, Majialong Industry Zone, Nanshan District, Shenzhen, Guangdong, China TEL: 86-755-26954280 FAX: 86-755-26954282 TRF No.: FCC 15.231/A Page 2 of 21 Report No.: ES141225315E Ver. 1.0 Access to the World VERIFICATION OF COMPLIANCE Applicant: RF Code, Inc. 9229 Waterford Centre Blvd. Suite 500, Austin, TX 78758-7511, United States Manufacturer: RF Code, Inc. 9229 Waterford Centre Blvd. Suite 500, Austin, TX 78758-7511, United States Product Description: Humidity-Temperature Tag Model Number: R156 Serial Number: N/A File Number: ES141225315E Date of Test: December 26, 2014 to January 28, 2015 APPLICABLE STANDARDS STANDARD TEST RESULT FCC 47 CFR Part 15, Subpart C PASS We hereby certify that: The above equipment was tested by SHENZHEN EMTEK CO., LTD. The test data, data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.4 (2014) and the energy emitted by the sample EUT tested as described in this report is in compliance with radiated emission limits of FCC Rules Part 15.231 REQUIREMENTS. The test results of this report relate only to the tested sample identified in this report. Date of Test : December 26, 2014 to January 28, 2015 Prepared by : Jack Li/Editor Reviewer : Joe Xia/Supervisor Approve & Authorized Signer : Lisa Wang/Manager TRF No.: FCC 15.231/A Page 3 of 21 Report No.: ES141225315E Ver. 1.0 Access to the World Table of Contents 1. GENERAL INFORMATION ................................................................................................... 5 1.1. PRODUCT DESCRIPTION ........................................................................................................................ 5 1.2. RELATED SUBMITTAL(S) / GRANT (S) .................................................................................................... 5 1.3. TEST METHODOLOGY ............................................................................................................................. 5 1.4. SPECIAL ACCESSORIES .......................................................................................................................... 5 1.5. EQUIPMENT MODIFICATIONS ................................................................................................................. 5 1.6. MEASUREMENT UNCERTAINTY .............................................................................................................. 6 1.7. TEST FACILITY ........................................................................................................................................ 6 2. SYSTEM TEST CONFIGURATION ..................................................................................... 7 2.1. EUT CONFIGURATION ............................................................................................................................ 7 2.2. EUT EXERCISE ....................................................................................................................................... 7 2.3. TEST PROCEDURE .................................................................................................................................. 7 2.4. DESCRIPTION OF TEST MODES .............................................................................................................. 7 2.5. SUMMARY OF TEST RESULTS ................................................................................................................ 7 2.6. DESCRIPTION OF SUPPORT UNITS ........................................................................................................ 7 3. CONDUCTED EMISSIONS TEST ....................................................................................... 8 3.1. MEASUREMENT PROCEDURE: ............................................................................................................... 8 3.2. TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION)....................................................................... 8 3.3. MEASUREMENT EQUIPMENT USED: ...................................................................................................... 8 3.4. CONDUCTED EMISSION LIMIT ................................................................................................................ 8 3.5. MEASUREMENT RESULT: ....................................................................................................................... 8 4. RADIATED EMISSION TEST ............................................................................................... 9 4.1. MEASUREMENT PROCEDURE ................................................................................................................. 9 4.2. TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION)....................................................................... 9 4.3. MEASUREMENT EQUIPMENT USED: .................................................................................................... 10 4.4. RADIATED EMISSION LIMIT ................................................................................................................... 10 4.5. CALCULATION OF AVERAGE FACTOR .................................................................................................. 12 4.6. MEASUREMENT RESULT ...................................................................................................................... 14 5. TRANSMISSION REQUIREMENT .................................................................................... 17 5.1. REQUIREMENT ........…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.92 MHz - 433.92 MHz | - |

M190 IR Enabled IT Asset Tag
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Mobile Asset Tag
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Asset Tracking and Event Transmitter
Equipment Class
DTS - Digital Transmission SystemAsset Tracking and Event TX
Equipment Class
DTS - Digital Transmission System
Asset Tracking Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter