FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. DSE CO.,LTD/
  3. P8TDS-126SD

P8TDS-126SDSelf-Ballasted Lamp

DSE CO.,LTD
Self-Ballasted Lamp - FCC ID P8TDS-126SD - DSE CO.,LTD
Click to zoom

Application Details

Equipment Class
8CC - Part 18 Consumer Device
Date of Grant
Mar 13, 2002
Application Purpose
Original Equipment
Date of Application
Mar 13, 2002
Equipment Note
Self-Ballasted Lamp
Frequency Range
0.04000000 - 0.05000000
Company
DSE CO.,LTD
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Schematics

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

USER’S MANUAL *Energy Saving Light Bulb *Works with Standard incandescent Dimmers, Photo Sensors and Timers *Light Weight, Flicker Free *Instant on Electronic Ballast CAUTIONS *Use only on 120volts, 60hertz frequency. *Never disassemble or modify the bulb. *Not for use in totally enclosed recessed fixtures. *Risk of electric shock. Do not use where directly exposed to water. *This device is not intended for use with emergency exit fixtures or emergency exit lights. *This product may produce interference with a T.V., Radio or a wireless remote control. If interference should occur, move the lamp away from the appliance a distance of three feet or more. Or, plug the lamp or the appliance into a different outlet. This product complies with Part 18 of FCC rules. *To prevent burns, please do not touch the bulb during operation or immediately after switching off. *Added weight of the device may cause instability of a free-standing portable lamp. Use only with portable table lamps in which the distance from the bottom of the base to the top of the lampholder does not exceed three(3) times minimum base width . Use only with portable table lamps which are provided with lamp shades. *Use in sockets in recessed cans controlled by wall dimmers may shorten lamp life.

External Photos

KTI02EF0163 FCC ID : P8TDS-126SD Korea Technology Institute Co., Ltd. Page 1 of 1 External photo

ID Label/Location Info

Korea Technology Institute Co., Ltd. Page 1 of 1 Label location FCC ID Label Location

ID Label/Location Info

Korea Technology Institute Co., Ltd. Page 1 of 1 FCC ID Sample Label LABELLING REQUIREMENTS PER ∫∫ ∫∫∫∫ ∫∫ ∫∫ ∫∫∫∫ ∫∫ 2.928 The Label shown shall be permanently affixed at a co nspicuous location on the device and be readily visible to the user at the time of purchase. Model Number: DS-126SD FCC ID : P8TDS-126SD DSE CO., LTD. Made in Korea

Internal Photos

KTI02EF0163 FCC ID : P8TDS-126SD Korea Technology Institute Co., Ltd. Page 1 of 2 Internal photo KTI02EF0163 FCC ID : P8TDS-126SD Korea Technology Institute Co., Ltd. Page 2 of 2 Internal photo

Test Report

KTI02EF0163 FCC ID : P8TDS-126SD Korea Technology Institute Co., Ltd. Page 1 of 13 Test Report Test Report No.:KTI02EF0163 Registration No.:99058 Applicant: DSE CO., LTD. Applicant Address: 20BLOCK-8LOT, 482-7 NONHYUN-DONG, NAMDONG-GU, INCHON 405-850, KOREA Product:SELF-BALLASTED LAMP FCC ID:P8TDS-126SDModel No.DS-126SD Receipt No.:02-0215Date of receipt:February 15,2002 Date of Issue:March 13, 2002 Testing location Korea Technology Institute Co., Ltd. 51-19, Sanglim3-Ri, Docheok-Myeun, Gwangju-Shi, Gyeungki-Do, Korea Test Standards:FCC/OET MP-5 Rule Parts:FCC Part 18, Equipment Class:RF lighting devices (Consumer Equipment) Test Result:The above mentioned product has been tested and passed. Tested by: S. B. Kim/ Engineer Approved by: G. C. Min/ President Signature Date Signature Date Other Aspects : Abbreviations : • OK, Pass=passed • Fail=failed • N/A=not applicable • • This test report is not permitted to copy partly without our permission. • This test result is dependent on only equipment to be used. • This test result is based on a single evaluation of one sample of the above mentioned. • This test report must not be used by the client to claim product endorsement by NVLAP or any agency of the U.S Government. • We certify this test report has been based on the measurement standards that is traceable to the national or international standards. KTI02EF0163 FCC ID : P8TDS-126SD Korea Technology Institute Co., Ltd. Page 2 of 13 •• Contents •• 1. 2. 3. 4. 5. 6. Annex1 Annex2 Contents List of Tables List of Figures List of Photographs General Test Site 2.1 Location 2.2 List of Test and Measurement Instruments 2.3 Test Data 2.4 Test Environment Description of the tested samples 3.1 Rating and Physical characteristics 3.2 Submitted documents Measurement conditions 4.1 Modes of operation 4.2 Additional equipments 4.3 Uncertainty 4.4 Test Setup Emission Test 5.1 Conducted Emissions 5.2 Radiated Emissions Photographs of the Test Set-up Label Photographs of EUT 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 6 6 7 8 11 12 14 15 16~19 • List of Tables Table 1 List of test and measurement equipment Table 2 Test Data. Conducted Emissions Table 3 Test Data. Radiated Emissions • List of Figures Figure 1 Spectral Diagram, LINE-PE Figure 2 Spectral Diagram, Neutral-PE • List of Photographs Photograph 1 Setup for Conducted Emissions Photograph 2 Setup for Radiated Emissions 4 11 13 9 10 16 17 Korea Technology Institute Co., Ltd. Page 3 of 13 KTI02EF0163 FCC ID : P8TDS-126SD 1. General This equipment has been shown to be capable of compliance with the applicable technical standards and was tested in accordance with the measurement procedures as indicated in this report. We attest to the accuracy of data. All measurements reported herein were performed by Korea Technology Institute Co., LTD. And were made under Chief Engineer’s supervision. We assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. 2. Test Site Korea Technology Institute Co., LTD 2.1 Location 51-19, Sanglim3-Ri, Docheok-Myeun, Gwangju-Shi, Gyeungki-Do, Korea The Test Site is in compliance with ANSI C63.4/1992 for measurement of radio Interference. Korea Technology Institute Co., Ltd. Page 4 of 13 KTI02EF0163 FCC ID : P8TDS-126SD 2.2 List of Test and Measurement Instruments Table 1 : List of Test and Measurement Equipment • Conducted Emissions Kind of Equipment Type S/N Calibrated until Spectrum Analyzer R3261C 61720417 11.2002 Field Strength Meter ESPC 832827/011 9.2002 LISN KNW407 8-1157-2 10.2002 LISN ESH2- Z5 8254601019 6.2002 Conducted Cable N/A N/A 11.2002 • Radiated Emissions Kind of Equipment Type S/N Calibrated until Field Strength Meter ESPC 832827/011 9.2002 Spectrum Analyzer R3261C 61720417 11.2002 Pre Amplif ier HP 8447D 2944A06874 11.2002 BiconiLog Antenna EMCO 3142B 1705 12.2002 KTI02EF0163 FCC ID : P8TDS-126SD Korea Technology Institute Co., Ltd. Page 5 of 13 3. Description of the tested samples The EUT is SELF-BALLASTED LAMP 3.1 Rating and Physical Characteristics • Consumption Power: 26W • Input Voltage: AC 120V • Frequency of input line: 60Hz • Life: 10,000Hrs 3.2 Submitted Documents • User’s Guide • Block Diagram KTI02EF0163 FCC ID : P8TDS-126SD Korea Technology Institute Co., Ltd. Page 6 of 13 4. Measurement Conditions Testing Input Voltage: AC 120V. 4.1 Modes of Operation The EUT was in the following operation mode during all testing; After warming up time of 30 minutes, Testing in mode of Lamp on. 4.2 Additional Equipment DEVICE TYPE Manufacturer M/N S/N FCC ID 4.3 Uncertainty 1) Radiated disturbance UC (Combined standard Uncertainty) = ± 1.8dB Expanded uncertainty U=Kuc K = 2 • U = ± 3.6dB 2) Conducted disturbance UC = ± 0.88dB U = Kuc=2xUc = ± 1.8dB KTI02EF0163 FCC ID : P8TDS-126SD Korea Technology Institute Co., Ltd. Page 7 of 13 4.4 Test setup EUT KTI02EF0163 FCC ID : P8TDS-126SD Korea Technology Institute Co., Ltd. Page 8 of 13 5. Emission Test 5.1 Conducted Emissions Result : Pass The line-conducted facility is located inside a 2.3M x 3.5M x 5.5M shielded closure. The shielding effectiveness of the shielded room is in accordance with MIL-Std-285 or NSA 605-05. A 1m x 1.5m wooden table 80cm high is placed 80cm away from the conducting ground plane and 40cm away from the sidewall of the shielded room. Kyoritsu Model KNW-407 (10kHz-30MHz) 50ohm/50 uH Line-Impedance Stabilization Networks (LISN) are bonded to the shielded room. The EUT is powered from the R&S LISN and the support equipment is powered from the Kyoritsu LISN. Power to the LISN are filtered by a high-current high-insertion loss shield enclosures power line filters (100dB 14kHz-1GHz). The purpose of the filter is to attenuate ambient signal interference and this filter is also bonded to the shielded enclosure. All electrical cables are shielded by braided tinned copper zipper tubing with inner diameter of 1/2”. If the EUT is a DC-Powered device, power will be derived from the source power supply…

Text truncated - open the document above for the full version.

Test Setup Photos

Korea Technology Institute Co., Ltd. Page1 of 2 6. Photograph of the Test Set-Up Photograph 1 : Setup for radiated Emissions Korea Technology Institute Co., Ltd. Page2 of 2 Photograph 2 : Setup for Conducted Emissions

Contact Information

Applicant

Hae-Un. Kim(Researcher)
[email protected](032) 815-1741Fax: (032) 815-1745

Test Firm

Bay Area Compliance LaboratoryJohn Chan
[email protected]408-732-9162Fax: 408-732-9164

Technical Specifications

#Rule PartsFrequency RangePower Output
1180.04 MHz - 0.05 MHz-