Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Page 1 of 2 FCC ID P9D-GRNYZ20 USER MANUA L APPLICATION Restaurants Hotels Homes Supermarkets Offices Stores PRECAUTIONS 1. Never use on a source voltage that fluctuates 6% above or 10% below the lamp ¡fl s rated voltage. 2. Never disassemble or modify – any changes could void the user ¡fl s authority to operate this device. 3. Do not hold the glass tube while installing. 4. Not for use in totally enclosed fixtures. 5. Risk of electric shock- do not use where directly exposed to water. 6. This device is not intended for use with emergency exit fixtures or emergency exit lights. 7. This product may cause interference to radio equipment and should not be installed nearmaritime safety communications equipment or other critical navigation or communication equipment operating between 0.45-30MHz8. To prevent burns,do not touch the bulb during operation or immediately after switching off. 9. Not for use with dimmers,electronic timer or photocell devices or occupancy sensor. 10. Never use in circumstance such as low or high temperature and high moisture. 11. Unsuitable for applications where the lamp must be turned on and off frequently. The device complies with Part 18 of the FCC rules. Page 2 of 2 FCC ID P9D-GRNYZ20 FEATURES Long life Soft and brisk light Wide voltage range 1/4 Power consumption compared with standard bulb 1/4 Heat radiation compared with standard bulb
Page 1 of 1 FCC ID P9D-GRNYZ20 Block Diagram: RECTTFIERFILTERCIRCUIT TRIGGERCIRCUIT TUBE MAINS HIGHFREQUENCYVIBRANTCIRCUIT
Page 1 of 1 FCC ID P9D-GRNYZ20 The external photo of the models SEL-15/20/23/26
Page 1 of 1 FCC ID P9D-GRNYZ20 The Labels for the four models GREEN SEL-15 15W 120V 60Hz 210mA FCC ID:P9D-GRNYZ20 GREEN SEL-23 23W 120V 60Hz 310mA FCC ID:P9D-GRNYZ20 GREEN SEL-20 20W 120V 60Hz 270mA FCC ID:P9D-GRNYZ20 GREEN SEL-26 26W 120V 60Hz 360mA FCC ID:P9D-GRNYZ20 The label for thi s location
Page 1 of 4 FCC ID P9D-GRNYZ20 The internal photos of the models SEL-15/20/23/26 The photos of the model SEL-15 Page 2 of 4 FCC ID P9D-GRNYZ20 The photos of the model SEL-20 Page 3 of 4 FCC ID P9D-GRNYZ20 The photos of the model SEL-23 Page 4 of 4 FCC ID P9D-GRNYZ20 The photos of the model SEL-26
Page 1 of 1 FCC ID P9D-GRNYZ20 Technical Description of Block Diagram When operation £‹ n ormal voltage 120V is changed into DC voltage about 160V through Bridge Rectifier. DC voltage is added to trigger circuit. Once DB3 istriggered, the stored charges in the capacitor discharge in the base oftransistor (below) to cause base current and drive transistor to open. With theturn of operation of the two transistors, it separately forms high frequencyvibrant circuit combined with L, C circuit, and further forms high frequencyvoltage between the filament terminals and lights the tube. After the tube isoperated normally, the circuit loses the vibration; L only takes the role o f keep down the current.
Page 1 of 5 FCC ID P9D-GRNYZ20 Schematics Diagram L2 T V8 V10 C7 V12 C6 LAMP V11 C5 R5 R4V7 V9 R3 C4 C3 V6V5 R2R1 C2 V4 V3 V2 V1 C1 F L1 Page 2 of 5 FCC ID P9D-GRNYZ20 The Material List Of SEL-15 (15W) No Symbol Type Quantity No Symbol Type Quantity 1 R1.R2.R3 RT14-360K 3 13 V9.V10 DK53/DK43 2 2 R4.R5 RJ14-20/22 ƒ‚ 214 T ƒ 8*5*3 2.5K 1 3 C2 CD11D-22uF/250V 1 ¡¡ ¡¡ AV R 1 * 1 / ƒ 0.4mm 0.5m 4 C1 CL21-100n/250V 1 15 L1 1.1mH/ ƒ 0.29mm 1 5 C3 CL11-47n/63V 1 16 L2 EE19 PC30/40 1 6 C4 CL11-560p/400V 1 ¡¡ ¡¡ QA-1/ ƒ 0.12mm*7 4g 7 C5 CL11-100n/630V 1 ¡¡ ¡¡ EE19 BOBBINS 1 8C6 ¡¡ ¡¡ ¡¡ ¡¡ POLYESTER TAPE 0.1m 9 C7 CL11-4n7/1KV 1 17 LAMP SEL-15W 1 10 V1-V5. V11.V12 1N4007 7 19 PLASTIC CASE PBT 1 11 V6 DB3 1 18 PWB GREEN-59 1 12 V7.V8 FR102 2 20 WIRE WHITE 1015-18 5"*2 Page 3 of 5 FCC ID P9D-GRNYZ20 The Material List Of SEL-20 (20W) No Symbol Type Quantity No Symbol Type Quantity 1 R1.R2.R3 RT14-360K 3 13 V9.V10 DK55/DK45 2 2 R4.R5 RJ14-20/22 ƒ‚ 214 T ƒ 8*5*3 2.5K 1 3 C2 CD11D-22uF/250V 1 ¡¡ ¡¡ AV R 1 * 1 / ƒ 0.4mm 0.5m 4 C1 CL21-100n/250V 1 15 L1 1.1mH/ ƒ 0.29mm 1 5 C3 CL11-47n/63V 1 16 L2 EE19 PC30/40 1 6 C4 CL11-560p/400V 1 ¡¡ ¡¡ QA-1/ ƒ 0.12mm*7 4g 7 C5 CL11-100n/630V 1 ¡¡ ¡¡ EE19 BOBBINS 1 8C6 ¡¡ ¡¡ ¡¡ ¡¡ POLYESTER TAPE 0.1m 9 C7 CL11-4n7/1KV 1 17 LAMP SEL-20W 1 10 V1-V5. V11.V12 1N4007 7 19 PLASTIC CASE PBT 1 11 V6 DB3 1 18 PWB GREEN-59 1 12 V7.V8 FR102 2 20 WIRE WHITE 1015-18 5"*2 Page 4 of 5 FCC ID P9D-GRNYZ20 The Material List Of SEL-23 (23W) No Symbol Type Quantity No Symbol Type Quantity 1 R1.R2.R3 RT14-360K 3 13 V9.V10 DK55/DK45 2 2 R4.R5 RJ14-20/22 ƒ‚ 214 T ƒ 8*5*3 2.5K 1 3 C2 CD11D-22uF/250V 1 ¡¡ ¡¡ AV R 1 * 1 / ƒ 0.4mm 0.5m 4 C1 CL21-100n/250V 1 15 L1 1.1mH/ ƒ 0.29mm 1 5 C3 CL11-47n/63V 1 16 L2 EE19 PC30/40 1 6 C4 CL11-560p/400V 1 ¡¡ ¡¡ QA-1/ ƒ 0.12mm*7 4g 7 C5 CL11-100n/630V 1 ¡¡ ¡¡ EE19 BOBBINS 1 8C6 CL11-2n2/1KV ¡¡ 1 ¡¡ ¡¡ ¡¡ POLYESTER TAPE 0.1m 9 C7 CL11-4n7/1KV 1 17 LAMP SEL-23W 1 10 V1-V5. V11.V12 1N4007 7 19 PLASTIC CASE PBT 1 11 V6 DB3 1 18 PWB GREEN-59 1 12 V7.V8 FR102 2 20 WIRE WHITE 1015-18 5"*2 Page 5 of 5 FCC ID P9D-GRNYZ20 The Material List Of SEL-26 (26W) No Symbol Type Quantity No Symbol Type Quantity 1 R1.R2.R3 RT14-360K 3 13 V9.V10 DK55/DK45 2 2 R4.R5 RJ14-20/22 ƒ‚ 214 T ƒ 8*5*3 2.5K 1 3 C2 CD11D-22uF/250V 1 ¡¡ ¡¡ AV R 1 * 1 / ƒ 0.4mm 0.5m 4 C1 CL21-100n/250V 1 15 L1 1.1mH/ ƒ 0.29mm 1 5 C3 CL11-47n/63V 1 16 L2 EE19 PC30/40 1 6 C4 CL11-560p/400V 1 ¡¡ ¡¡ QA-1/ ƒ 0.12mm*7 4g 7 C5 CL11-100n/630V 1 ¡¡ ¡¡ EE19 BOBBINS 1 8C6 CL11-2n2/1KV ¡¡ 1 ¡¡ ¡¡ ¡¡ POLYESTER TAPE 0.1m 9 C7 CL11-4n7/1KV 1 17 LAMP SEL-26W 1 10 V1-V5. V11.V12 1N4007 7 19 PLASTIC CASE PBT 1 11 V6 DB3 1 18 PWB GREEN-59 1 12 V7.V8 FR102 2 20 WIRE WHITE 1015-18 5"*2
Report no: JSH02*0046-002 Page 1 of 10 FCC ID P9D-GRNYZ20 Application for FCC Identifier On Behalf of Yangzhou Green Lighting & Electronic Co., Ltd. (FCC ID P9D-GRNYZ20) Summary The equipment comply with the requirements according to the following standard(s): 47CFR Part 18: Industrial, Scientific, and Medical Equipment FCC/OET MP-5 (1986): FCC Methods of Measurements of Radio Noise Emissions From Industrial, Scientific, and Medical Equipment ANSI C63.4 (2000): Interim Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9kHz to 40GHz. Description The appliances were tested by Shanghai Institute of Process Automation Instr. and found compliance with relevant requirements described in FCC Part 18 RF Lighting Device. Test results are contained in this test report and Intertek Testing Services ETL SEMKO Shanghai Limited is assumed full responsibility for the accuracy and completeness of these measurements. The test report applies to tested samples only and shall not be reproduced in part without written approval of Intertek Testing Services ETL SEMKO Shanghai Limited. Date of Test: February 3, 2002 Date of Issue: May 7, 2003 Prepared by: Report Approved by: Tino Pan (Engineer)Ole Stiling (Chief Engineer) Report no: JSH02*0046-002 Page 2 of 10 FCC ID P9D-GRNYZ20 Description of Test Facility Name of Firm:AUDIX Technology (Shanghai) Co., Ltd. Site Location:3F #34 Bldg. No.680 Guiping Rd., Caohejing Hi-Tech Park, Shanghai, P.R.China Name of contact :Mr. Alex (first name) Chiu (last name) Phone:86-21-64955500 Fax: 86-21-64955491 E-mail address:[email protected] NVLAP Code : 200371-0 Report no: JSH02*0046-002 Page 3 of 10 FCC ID P9D-GRNYZ20 CONTENTS Summary..............................................................................................................................1 Description...........................................................................................................................1 Description of Test Facility...................................................................................................2 1.Applicant Information.......................................................................................................4 2.Information of Equipment Under Test (EUT)....................................................................4 2.1 Identification of the EUT...............................................................................................4 2.2 Additional information about the EUT...........................................................................4 2.3 Peripheral equipment....................................................................................................4 3. Conducted Powerline Measurement.................................................................................5 3.1 Conduction Limit..........................................................................................................5 3.2 Instruments List............................................................................................................5 3.3 Test Setup....................................................................................................................6 3.4 Test Configuration........................................................................................................6 3.5 Test Procedure.............................................................................................................7 3.6 Test Results..................................................................................................................7 3.7 Measurement Uncertainty.............................................................................................9 4. Conducted Powerline Calculation...................................................................................10 Report no: JSH02*0046-002 Page 4 of 10 FCC ID P9D-GRNYZ20 1.Applicant Information Applicant :Yangzhou Green Lighting & Electronic Co., Ltd. No.2 Fenghuaqiao, Yangzhou, Jiangsu, China Manufacturer: Yangzhou Green Lighting & Electronic Co., Ltd. No.2 Fenghuaqiao, Yangzhou, Jiangsu, China Country of origin: P.R. China Name of contact: Mr. Weishen (first name) Hua (last name) Telephone: 86-514-7361887 Telefax: 86-514-7337270 2.Information of Equipment Under Test (EUT) 2.1 Identification of the EUT Equipment: Compact Fluorescent Lamp Type of EUT: ̨ Production ® Pre-product ® Pro-type Type/model: Serial number: 02*0046-001, 02*0046-002, 02*0046-003, 02*0046-004 Date of sample receipt2001-10-9 Date of test2001-10-23 Rating: 120V~, 60Hz 15W for SEL-15, 20W for SEL-20, 23W for SEL-23 26W for SEL-26 2.2 Additional information about the EUT The family of product contains 8 models, which were described above. They are the same in schematic diagram, difference between them are their appearance and rating. Internal clock frequencies or other used frequencies: None The tests have been performed on the EUT provided with the following modification: None 2.3 Peripheral equipment None Report no: JSH02*0046-002 Page 5 of 10 FCC ID P9D-GRNYZ20 3. Conducted Powerline Measurement 3.1 Conduction Limit For Consumer Equipment Maximum RF line voltage measured with a 50uH/50 ohm LISN Frequency (MHz) (μV)dB(μV) 0.45 – 2.5125048 2.51 – 3.0300069.5 3.0 – 3025048 RF Line Voltage dB(μV) = 20 lg RF Line Voltage (μV) 3.2 Instruments List The following instruments were used during the measurement of RF voltage conducted back into the power lines. ItemEquipmentManu.TypeSerials no.Last Cal. Cal. Interval 1 EMI Test Receiver Rohde & Schwarz ESHS10844077/020Apr 24, 011 Year 2L.I.S.N. KyoritsuKNW-4078-1280-4 May 08, 011 Year Report no: JSH02*0046-002 Page 6 of 10 FCC ID P9D-GRNYZ20 3.3 Test Setup Note: means power line means signal line 3.4 Test Configuration The Conducted Powerline Measurement was proceeded in a shielded room. The EUT was connected to AC power source through an Linear Impedance Stability Networ…
Text truncated - open the document above for the full version.
Page 1 of 16 FCC ID P9D-GRNYZ20 The waveform of the conducted power line The waveform for the model SEL-15 Page 2 of 16 FCC ID P9D-GRNYZ20 Page 3 of 16 FCC ID P9D-GRNYZ20 Page 4 of 16 FCC ID P9D-GRNYZ20 Page 5 of 16 FCC ID P9D-GRNYZ20 The waveform for the model SEL-20 Page 6 of 16 FCC ID P9D-GRNYZ20 Page 7 of 16 FCC ID P9D-GRNYZ20 Page 8 of 16 FCC ID P9D-GRNYZ20 Page 9 of 16 FCC ID P9D-GRNYZ20 The waveform for the model SEL-23 Page 10 of 16 FCC ID P9D-GRNYZ20 Page 11 of 16 FCC ID P9D-GRNYZ20 Page 12 of 16 FCC ID P9D-GRNYZ20 Page 13 of 16 FCC ID P9D-GRNYZ20 The waveform for the model SEL-26 Page 14 of 16 FCC ID P9D-GRNYZ20 Page 15 of 16 FCC ID P9D-GRNYZ20 Page 16 of 16 FCC ID P9D-GRNYZ20
Page 1 of 1 FCC ID P9D-GRNYZ20 The Test Setup For Conducted Power Line
16th Floor, Fangdo Mansion, No. 201 Laoshan Road · Shanghai · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 18 | 0.044 MHz - 0.046 MHz | - |