FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Hung Yi Enterprise Co., Ltd./
  3. PACHYE-RC-1097

PACHYE-RC-1097Door Remote Controller

Hung Yi Enterprise Co., Ltd.
Door Remote Controller - FCC ID PACHYE-RC-1097 - Hung Yi Enterprise Co., Ltd.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Dec 20, 2000
Application Purpose
Original Equipment
Date of Application
Oct 29, 2000
Equipment Note
Door Remote Controller
Frequency Range
336.00000000 - 336.00000000
Company
Hung Yi Enterprise Co., Ltd.
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗

External Photos

↗
↗

ID Label/Location Info

↗

Internal Photos

↗
↗

Operational Description

↗

Schematics

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

HUNG YI ENTERPRISE CO., LTD. 1097 REMOTE CONTROL USER’S GUIDE HOW TO ASSEMBLY :1. MAKE SURE THE AC POWER IS 220V-240V 50/60Hz 2. SEE THE PUSH-BUTTON OF ROLLING-DOOR. (CARAGE DOOR)AND MEMEORY THE WIRE’S COLOR. 3. FOR SAFETY. TURN OFF AC POWER. 4. CONNECT THE WIRE OF RECIEVER TO PUSH-BUTTON’S WIRE. 5. CONNECT THE 2 BLACK WIRES TO POWER SOURCE. 6. INSERT THE CONNECTOR TO SOCKET OF RECEIVER. WARNING :Changes or modifications to this unit not expressly approved by the partyresponsible for compliance could void the user’s authority to operate theequipment.The device complies with part 15 of the FCC Rules. Operation is subject tothe following two conditions: (1) This device may not cause harmfulinterference, and (2) this device must accept any interference received,including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on , the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is needed. consult the dealer or an experienced radio/TV Technician for help.

Block Diagram

Block Diagram Model : 1097 Address Code System Timing Control Logic Code Generation OSC Transmitter L R Frequency: 336MHz

Test Report

Hung Yi Enterprise Co., Ltd. Application For Certification (FCC ID: PACHYE-RC-1097) Transmitter WO# 0010935 WN/at September 28, 2000 INTERTEK TESTING SERVICES FCC ID: PACHYE-RC-1097 i LIST OF EXHIBITS INTRODUCTION EXHIBIT 1 :General Description EXHIBIT 2 :System Test Configuration EXHIBIT 3 :Emission Results EXHIBIT 4 :Equipment Photographs EXHIBIT 5 :Product Labelling EXHIBIT 6 :Technical Specifications EXHIBIT 7 :Instruction Manual EXHIBIT 8 :Miscellaneous Information INTERTEK TESTING SERVICES FCC ID: PACHYE-RC-1097 ii MEASUREMENT/TECHNICAL REPORT Hung Yi Enterprise Co., Ltd. - MODEL: 1097 FCC ID: PACHYE-RC-1097 September 28, 2000 This report concerns (check one:)Original Grant X Class II Change Equipment Type: Low Power Transmitter (example: computer, printer, modem, etc.) Deferred grant requested per 47 CFR 0.457(d)(1)(ii)?Yes No X If yes, defer until: date Company Name agrees to notify the Commission by: date of the intended date of announcement of the product so that the grant can be issued on that date. Transition Rules Request per 15.37?Yes No X If no, assumed Part 15, Subpart C for intentional radiator - the new 47 CFR [10-1-96 Edition] provision. Report prepared by:Wilson Loke Intertek Testing Services 2/F., Garment Center, 576, Castle Peak Road, HONG KONG Phone: 852-2173-8575 Fax:852-2745-8306 INTERTEK TESTING SERVICES FCC ID: PACHYE-RC-1097 iii Table of Contents 1.0 General Description................................................................................................................ 2 1.1 Product Description ............................................................................................................... 2 1.2 Related Submittal(s) Grants ................................................................................................... 2 1.3 Test Methodology .................................................................................................................. 3 1.4 Test Facility............................................................................................................................ 3 2.0 System Test Configuration...................................................................................................... 5 2.1 Justification ............................................................................................................................ 5 2.2 EUT Exercising Software ....................................................................................................... 5 2.3 Special Accessories ................................................................................................................ 5 2.4 Equipment Modification ........................................................................................................ 6 2.5 Support Equipment List and Description ............................................................................... 6 3.0 Emission Results...................................................................................................................... 8 3.1 Field Strength Calculation ...................................................................................................... 9 3.2 Radiated Emission Configuration Photograph ..................................................................... 11 3.3 Radiated Emission Data ....................................................................................................... 12 4.0 Equipment Photographs....................................................................................................... 16 5.0 Product Labelling.................................................................................................................. 18 6.0 Technical Specifications........................................................................................................ 20 7.0 Instruction Manual................................................................................................................ 22 8.0 Miscellaneous Information................................................................................................... 24 8.1 Measured Bandwidth ........................................................................................................... 25 8.2 Discussion of Pulse Desensitization ..................................................................................... 26 8.3 Calculation of Average Factor ............................................................................................. 27 8.4 Emissions Test Procedures...................................................................................................28 INTERTEK TESTING SERVICES FCC ID: PACHYE-RC-1097 iv List of attached file Exhibit typeFile Descriptionfilename Cover LetterLetter of Agencyletter.pdf Test ReportTest Reportreport.doc Operation DescriptionTechnical Descriptiondescri.pdf Test Setup PhotoRadiated Emissionradiated1.jpg, radiated2.jpg Test ReportBandwidth Plotbw.pdf External PhotoExternal Photoophoto1.jpg to ophoto2.jpg Internal PhotoInternal Photoiphoto1.jpg to iphoto2.jpg Block DiagramBlock Diagramblock.pdf SchematicsCircuit Diagramcircuit.pdf ID Label/LocationLabel Artwork and Locationlabel.pdf User ManualUser Manualmanual.pdf Test ReportAverage Factoraf.pdf INTERTEK TESTING SERVICES FCC ID: PACHYE-RC-1097 1 EXHIBIT 1 GENERAL DESCRIPTION INTERTEK TESTING SERVICES FCC ID: PACHYE-RC-1097 2 1.0General Description 1.1Product Description The Equipment Under Test (EUT) is a Door Remote Controller operating at 336.0 MHz. The EUT is powered by 12V alkaline battery. By pressing the button, it can send the control signal to the corresponding receiver. Once the button B releasing, the transmission will be stopped within 1 second. For electronic filing, the brief circuit description is saved with filename: descri.pdf 1.2Related Submittal(s) Grants This is a single application for certification of a transmitter. INTERTEK TESTING SERVICES FCC ID: PACHYE-RC-1097 3 1.3Test Methodology Both AC mai…

Text truncated - open the document above for the full version.

Test Report

Hung Yi Enterprise Co., Ltd. Application For Certification (FCC ID: PACHYE-RC-1097) Transmitter WO# 0010935 WN/at September 28, 2000 INTERTEK TESTING SERVICES FCC ID: PACHYE-RC-1097 i LIST OF EXHIBITS INTRODUCTION EXHIBIT 1 :General Description EXHIBIT 2 :System Test Configuration EXHIBIT 3 :Emission Results EXHIBIT 4 :Equipment Photographs EXHIBIT 5 :Product Labelling EXHIBIT 6 :Technical Specifications EXHIBIT 7 :Instruction Manual EXHIBIT 8 :Miscellaneous Information INTERTEK TESTING SERVICES FCC ID: PACHYE-RC-1097 ii MEASUREMENT/TECHNICAL REPORT Hung Yi Enterprise Co., Ltd. - MODEL: 1097 FCC ID: PACHYE-RC-1097 September 28, 2000 This report concerns (check one:)Original Grant X Class II Change Equipment Type: Low Power Transmitter (example: computer, printer, modem, etc.) Deferred grant requested per 47 CFR 0.457(d)(1)(ii)?Yes No X If yes, defer until: date Company Name agrees to notify the Commission by: date of the intended date of announcement of the product so that the grant can be issued on that date. Transition Rules Request per 15.37?Yes No X If no, assumed Part 15, Subpart C for intentional radiator - the new 47 CFR [10-1-96 Edition] provision. Report prepared by:Wilson Loke Intertek Testing Services 2/F., Garment Center, 576, Castle Peak Road, HONG KONG Phone: 852-2173-8575 Fax:852-2745-8306 INTERTEK TESTING SERVICES FCC ID: PACHYE-RC-1097 iii Table of Contents 1.0 General Description................................................................................................................ 2 1.1 Product Description ............................................................................................................... 2 1.2 Related Submittal(s) Grants ................................................................................................... 2 1.3 Test Methodology .................................................................................................................. 3 1.4 Test Facility............................................................................................................................ 3 2.0 System Test Configuration...................................................................................................... 5 2.1 Justification ............................................................................................................................ 5 2.2 EUT Exercising Software ....................................................................................................... 5 2.3 Special Accessories ................................................................................................................ 5 2.4 Equipment Modification ........................................................................................................ 6 2.5 Support Equipment List and Description ............................................................................... 6 3.0 Emission Results...................................................................................................................... 8 3.1 Field Strength Calculation ...................................................................................................... 9 3.2 Radiated Emission Configuration Photograph ..................................................................... 11 3.3 Radiated Emission Data ....................................................................................................... 12 4.0 Equipment Photographs....................................................................................................... 15 5.0 Product Labelling.................................................................................................................. 17 6.0 Technical Specifications........................................................................................................ 19 7.0 Instruction Manual................................................................................................................ 21 8.0 Miscellaneous Information................................................................................................... 23 8.1 Measured Bandwidth ........................................................................................................... 24 8.2 Discussion of Pulse Desensitization ..................................................................................... 25 8.3 Calculation of Average Factor ............................................................................................. 26 8.4 Emissions Test Procedures...................................................................................................27 INTERTEK TESTING SERVICES FCC ID: PACHYE-RC-1097 iv List of attached file Exhibit typeFile Descriptionfilename Cover LetterLetter of Agencyletter.pdf Test ReportTest Reportreport.doc Operation DescriptionTechnical Descriptiondescri.pdf Test Setup PhotoRadiated Emissionradiated1.jpg, radiated2.jpg Test ReportBandwidth Plotbw.pdf External PhotoExternal Photoophoto1.jpg to ophoto2.jpg Internal PhotoInternal Photoiphoto1.jpg to iphoto2.jpg Block DiagramBlock Diagramblock.pdf SchematicsCircuit Diagramcircuit.pdf ID Label/LocationLabel Artwork and Locationlabel.pdf User ManualUser Manualmanual.pdf Test ReportAverage Factoraf.pdf INTERTEK TESTING SERVICES FCC ID: PACHYE-RC-1097 1 EXHIBIT 1 GENERAL DESCRIPTION INTERTEK TESTING SERVICES FCC ID: PACHYE-RC-1097 2 1.0General Description1.0General Description 1.1Product Description1.1Product Description The Equipment Under Test (EUT) is a Door Remote Controller operating at 336.0 MHz. The EUT is powered by 12V alkaline battery. By pressing the button, it can send the control signal to the corresponding receiver. Once the button B releasing, the transmission will be stopped within 1 second. For electronic filing, the brief circuit description is saved with filename: descri.pdf 1.2Related Submittal(s) Grants1.2Related Submittal(s) Grants This is a single application for certification of a transmitter. INTERTEK…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Chao-Yuan Lee(President)
[email protected]886-7-345-1908Fax: 886-7-345-1335

Technical Contact

Intertek Testing Services Hong Kong Ltd.Wilson Loke
[email protected]852-2173-8575

2/F., Garment Centre, · Kowloon · Hong Kong

Non-Technical Contact

Intertek Testing Services Hong Kong Ltd.Wilson Loke
[email protected]852-2173-8575

Test Firm

Intertek Testing Services Hong KongBilly Chow
[email protected]852-2173-8528Fax: 852-2371-0914

Technical Specifications

#Rule PartsFrequency RangePower Output
115C336 MHz - 336 MHz-
Grant Notes
Reissued by FCC