PASRM20MRadio Transceiver, Model RM20M

Destinator Technologies Inc. (Canada)
Radio Transceiver, Model RM20M - FCC ID PASRM20M - Destinator Technologies Inc. (Canada)
Click to zoom

Application Details

Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
Jul 26, 2001
Application Purpose
Original Equipment
Date of Application
May 16, 2001
Equipment Note
Radio Transceiver, Model RM20M
Frequency Range
896.00000000 - 901.00000000
Company
Destinator Technologies Inc. (Canada)
Country
Canada

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗
↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Vehicle Location Device – VLD100 Series User Manual Version: 1.2.6 May 8, 2001 iiVersion: 1.2.6 May 8, 2001 Vehicle Location Device - VLD100 Series Copyright © 2001, PowerLOC Technologies Inc. All rights reserved. No part of the contents of this manual can be copied, altered, or reproduced in any form without prior written permission from PowerLOC. L-Biz, and LSP are registered trademarks belonging to PowerLOC Technologies Inc. Java is a registered trademarks belonging to Sun Microsystems. PowerLOC reserves the right to make improvements in the products described in this manual at any time without prior notice. PowerLOC makes no representation or warranties with respect to the content of this manual. Further, PowerLOC reserves the right to make any changes in its content without obligation to notify any person or organization of such revisions or changes. Version: 1.2.6 May 8, 2001iii User Manual Dear Customer, Thank you for purchasing PowerLOC Vehicle Location Device (VLD100 Series). For your safety and optimum performance of the device, please read the instructions in this manual carefully. Please record the serial number, MAN and MIN codes found on the back of the VLD Module in the space provided below. You will need these numbers for activation of the VLD, and for future refernces. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. WARNING! To satisfy FCC RF exposure rquirements for mobile transmitting devices, a minimum seperation distance must be maintained between the antenna of this device and persons during device operation. Operation at closer than this distance is not recommended. For detailed distance for each module, see Tables 5-1 and 5-2. Unit Serial Number ivVersion: 1.2.6 May 8, 2001 Vehicle Location Device - VLD100 Series . CAUTION! Changes or modifications not expressly approved by PowerLOC voids the user’s authority to operate the equipment. CAUTION! This equipment has been tested and found to comply with the limits for a Class B digital devices, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna; Increase the separation between the equipment and receiver; Consult the dealer or an experienced Automotive/Audio technician for help CAUTION! To prevent fire or risk hazard, do not expose the VLD unit to rain or excessive moisture. CAUTION! This device should only be used for a vehicle application, and should only be installed by authorized installers. Product warranty is null and void if the device is not installed by an authorized installer. Version: 1.2.6 May 8, 2001v User Manual Table of Contents Product Description . . . . . . . . . . . . . . . . . . . .1-1 Package Contents . . . . . . . . . . . . . . . . . . . . .1-1 VLD Module . . . . . . . . . . . . . . . . . . . . . . . . .1-3 Wireless Antenna . . . . . . . . . . . . . . . . . . . .1-4 GPS Receiver . . . . . . . . . . . . . . . . . . . . . . .1-4 Wiring Harness . . . . . . . . . . . . . . . . . . . . . .1-4 Optional . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5 VLD Introduction . . . . . . . . . . . . . . . . . . . . . .1-6 Mobile VLD . . . . . . . . . . . . . . . . . . . . . . . . .1-7 Tracker Server . . . . . . . . . . . . . . . . . . . . . . .1-9 Fleet Manager (Client Software) . . . . . . . . .1-9 LSP Overview . . . . . . . . . . . . . . . . . . . . . . . .1-9 VLD101 and VLD103 . . . . . . . . . . . . . . . . .1-10 Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-11 Environment . . . . . . . . . . . . . . . . . . . . . . .1-11 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . .1-11 Repair and Returns . . . . . . . . . . . . . . . . . .1-11 Introduction To Mobile GPS . . . . . . . . . . . . .2-1 Global Positioning System Overview . . . . . . .2-1 Mobile GPS Applications . . . . . . . . . . . . . . . .2-3 Asset Recovery . . . . . . . . . . . . . . . . . . . . . .2-3 Single Vehicle Tracking . . . . . . . . . . . . . . . .2-3 Fleet Management . . . . . . . . . . . . . . . . . . . .2-3 VLD Provisioning . . . . . . . . . . . . . . . . . . . . . .3-1 Provisioning Overview . . . . . . . . . . . . . . . . . .3-1 Registration . . . . . . . . . . . . . . . . . . . . . . . . .3-1 Activation . . . . . . . . . . . . . . . . . . . . . . . . . . .3-2 Software Installation and Setup . . . . . . . . . .4-1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-1 Staying Updated . . . . . . . . . . . . . . . . . . . . .4-1 Starting the Client Software . . . . . . . . . . . . . .4-2 The Client Screen . . . . . . . . . . . . . . . . . . . . .4-5 Active Map . . . . . . . . . . . . . . . . . . . . . . . . . .4-6 viVersion: 1.2.6 May 8, 2001 Vehicle Location Device - VLD100 Series Fleet Controller . . . . . . . . . . . . . . . . . . . . . . 4-6 Message Monitor . . . . . . . . . . . . . . . . . . . . 4-8 Tool Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8 Map Controller . . . . . . . . . . . . . . . . . . . . . . 4-9 Menu Bar . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9 Status Bar . . . . . . . . . . . . . . . . . . . . . . . . . 4-10 Finding a vehicle . . . . . . …

Text truncated - open the document above for the full version.

Cover Letter(s)

                 !"#$%&' ( )*+$$,$ -./0 1&2*&'3 45  #6 .-$ 7 #$+  %'   # %'    !  ""#$#% #6 .-$ 7&&###' ""(##) (#% ( #%(#%#'*" (#+ , *&( %"#) -.#+  .'*" (#/0  1)/230 44 5&'(' "" *% &#' %% #"(%(#+6  4##$#'# ""(#% 3# "" *% &#'#$"#7%  %8""(#+# #('-$ $3/(.#" #& " *,-*#)"& " % % #" #$ ##'/ " % # ('/#3###('#  /%'*9 "#'###(#(# . 33)-- 2   .-3-,: ;-; +24<4 4    = #       . '3,+-$+ >+,+-$ $   .3!:                    2                          !"#$% & '  !"#!  ( ) *+++,-  # ), ' .' *,-  /0' , 

Cover Letter(s)

RESEARCH IN MOTION Research In Motion Limited 295 Phillip Street Waterloo, Ontario Canada N2L 3W8 +1 519 888 7465, fax +1 519 888 6906 E-mail: [email protected] Our Ref: 01947-CERT-FCC-COVER-021July 23, 2001 Federal Communication Commission Equipment Authorization Division Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21045 Reference :FCC ID : L6AR902M-2-O Subject :Letter requesting confidentiality of R902M-2-O radio modem device FCC Certification application. Pursuant to CFR 47 Chapter 1 Section 0.459, Research In Motion Limited (RIM) requests that the following identified detailed technical information regarding the R902M-2-O device be held confidential by the Federal Communication Commission (FCC) and as such be withheld from public inspection. RIM does not disclose proprietary confidential information about our products to any third parties and as such we request that the FCC does the same and forward the confidentiality acceptance letter to RIM. Our FCC submissions are considered proprietary confidential information. Pursuant to CFR 47 Chapter 1 Sections 0.457(d) and 0.457(d)(2)(i) the exhibits contain details of trade secrets and technical data that is customarily guarded from competitors and not released to the public by Research In Motion Limited. The specific parts of the Exhibits indicated in this letter are considered confidential by RIM and as such should be prevented from disclosure to public and competitors. RIM has taken necessary measures to have limited access to confidential documents only to RIM internal employees on a need-to-know basis, and have signed confidentiality agreements with employees. If the disclosure of such information is made public, it will cause serious competitive harm to RIM. Previously, none of the requested confidential Exhibits have been disclosed to third parties by RIM. The following Exhibits with specific sections described, submitted with the Form 731 Attachments should be held confidential: Exhibit Parts List/Tune Up InfoSection 010-9-1 and 010-9-2, CFR 47 Section 2.983(d)(9) - Description of operational, test, and device tune-up technical procedure-“DOC-01606-007”, and operators’ manual-“DOC- 01606-008” Section 010-10, CFR 47 Section 2.983(d)(10) - Description of frequency stabilizing circuitry Exhibit Parts List/Tune Up InfoSection 010-11-1, CFR 47 Section 2.983(d)(11) - Description of circuits for suppression of spurious radiation Section 010-11-2, CFR 47 Section 2.983(d)(11) - Description of circuits for modulation limiting Section 010-11-3, CFR 47 Section 2.983(d)(11) - Description of circuits for power limiting Exhibit Operational DescriptionSection 010-12 and 010-12-1, CFR 47 Section 2.983(d)(12) - Description of digital modulation format and necessary bandwidth Exhibit Parts List/Tune Up InfoSection 010-12-2 and 010-12-3, CFR 47 Section 2.983(d)(12) – Modulation generation methods and circuits. Detailed diagrams of modulation format and generation methods and circuits Exhibit Operational DescriptionSection 011-1 and 011-2, CFR 47 Sections 2.975(a)(3), 2.983(d)(6) and 2.1033(b)(4) - Detailed system and functional description Exhibit Parts List/Tune Up InfoSection 011-3, CFR 47 Sections 2.975(a)(3), 2.983(d)(6) and 2.1033(b)(4) - Detailed technical RF and electrical circuit description Exhibit Block Diagram01947-CERT-FCC-BLOCK-“R902M-2-O RADIO BLOCK”, CFR 47 Section 2.983(d)(6) – Detailed technical radio modem block diagram Exhibit Schematics“Tadpole OEM” SCH-01947-001, CFR 47 Section 2.983(d)(7) - Complete technical schematic circuit diagrams Yours truly, MasudS.Attayi,P.Eng. Senior Certification Engineer Research In Motion Limited ( 519 ) 888 – 7465 x 2442 [email protected] RESEARCH IN MOTION Research In Motion Limited 295 Phillip Street Waterloo, Ontario Canada N2L 3W8 +1 519 888 7465, fax +1 519 888 6906 E-mail: [email protected] Our Ref: 01947-CERT-FCC-Cover-022July 23, 2001 Federal Communications Commission Equipment Authorization Division Application Processing Branch 7435 Oakland Mills Rd. Columbia, Md. 21046 FCC ID:L6AR902M-2-O Subject:FCC Part 90 Certification Application for Research In Motion Limited, Model R902M-2-O This is to inform that Research In Motion is submitting the technical documentation of our radio modem Model R902M-2-O (existing FCC ID: L6AR902M-2-O ) in support of the application for Certification of our integrator, PowerLOC Technologies Inc. , with FCC ID: PASRM20M. The Model R902M-2-O is a radio modem intended for integration into other equipment to allow wireless data communication. All required documents in compliance with Parts 2 and 90 of the FCC Rules have been provided in the attached Exhibits. Research In Motion would like to request confidentiality as indicated in the Form 731, Item 8 and as requested in the letter Ref: 01947-CERT-FCC-COVER-021, under Exhibit “Covering Letters”. Please do not hesitate to call at (519) 888-7465 x2442 or email at [email protected] should you require additional information or have any questions. Yours truly, MasudS.Attayi,P.Eng. Senior Certification Engineer Research In Motion Limited ( 519 ) 888 – 7465 x 2442 [email protected]

External Photos

             !"#$%& % '&                     !"#$%& % &'&        

ID Label/Location Info

                                                                     !  """""""""""    #    $   %                                      

Internal Photos

              !"#$%# &'                       !"#$%# $&'                !"#$%# (&'                !"#$%# '&'  

Test Report

         $+  7 %'   # %'    #6 .-$ 7                   ,,$,,$$()  !"#%&'( )   .8$ 7#9*1:   .'.# " #/ #'#' #% . +3, %-$  >(, #%-$ $ # .('@ "%3  #2      " #, " 2:'   .#2 :$. ')/!-/.('(    /#2    .##2 (' A"                              .             !"#$%& '  !"#! 9$6667.*$7,,+.;7.<$,7  #%=&'" ># " ?   $ $+"  %'  # %'    4@ # > A#9*1:  7 # ( * # 3:@  3!"%''3  .+B20 4<04  )8+B20 4<04< -2*'+# #('C"#(+(6#2'##"2!!&&&+# #('4+(  • /./1D5"##7;>3,15(( ##7A!.-31# 5>/1E"5 • (( #/# 15 4371- "!,-!5 • ($F!3#)15 •                              >                                                                                                                                  !    "            #   $                                     %                     !     "$ %  $      !                  !         #           #         &#          $     "$    &#      '  ( %)(()  !"#""   $ % & "' #""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""&  !"#"'"  ( ) ("""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""&  !"#" "  * +, """"""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""&  !"#""  * -"""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""&  !"#"#"  * .""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""       $    *      '(%()…

Text truncated - open the document above for the full version.

Test Report

ELECTROMAGNETIC EMISSIONS TEST REPORT BY COM-SERVE CORPORATION KITCHENER, ONTARIO CANADA RESULTS R902M-2-O COMPLIANCE (yes) (no) RF POWER OUTPUT Transmitter: 2.985 ( ) ( ) OCCUPIED BANDWIDTH Transmitter: 2.989 ( X ) ( ) SPURIOUS EMISSIONS AT THE ANTENNA TERMINALS Transmitter: 2.991 ( X ) ( ) FIELD STRENGTH OF SPURIOUS RADIATION Transmitter: 2.993 ( X ) ( ) FREQUENCY STABILITY Transmitter: 2.995 ( ) ( ) BANDWIDTH LIMITATIONS Transmitter: 90.210(j) ( X ) ( ) SYSTEM DESCRIPTION The R902M-2-O Radio Modem Device The R902M-2-O radio modem is intended for integration into other equipment to allow wireless data communication. The R902M-2-O has a standard TTL level serial asynchronous interface allowing it to communicate directly with embedded controllers and host processors. Radio evaluation and application development is facilitated by the radio monitor board (PCB-02120-001). The radio monitor board translates the TTL serial interface signals to standard RS-232 level signals. The RS-232 level signals can be directly interfaced to a personal computer serial port. The radio monitor board acts as an interface between a standard serial I/O and the RIM R902M-2-O radio. The board translates the 3.0 volt serial interface signals to standard RS-232 level signals. The radio monitor board also provides a regulated and filtered 4.3 VDC to the RIM R902M-2-O radio. The radio power and the level translation circuit power, are derived from a 05V @ 2.4A AC/DC power adapter, model number WR91A2400CCP. The R902M-2-O radio, radio monitor board, AC adapter, 9123 Eclipse II cellular antenna and all required interface cables will be typically marketed as the “RIM 902M Radio Evaluation and Development Kit”. The OEM 900 MHz packet data radio modem is formally known as model R902M-2-O . The RIM radio monitor board, RS-232 converter is formally model 02120-001 . The antenna used for testing and to be included in the evaluation and development kit is an ECLIPSE II magnet mount cellular antenna Model 9123 from the Antenna Company International Limited. Please refer to the attached data sheet for Model 9123. The model 9123 is a semi-custom device with a 6 feet RG58A/U cable and a SMA male connector. All other specifications are the same as standard models 9110, 9114, or 9119. Normal radio modem operation for live use is called burst packet activity. The radio is normally in receive mode listening to all network activity. When a data packet is received that is explicitly addressed to the radio, it then transmits a short acknowledgment packet. When data is to be transmitted from the radio modem, the radio modem first receives system information from the network to determine when to transmit. There is no deterministic pattern to the network traffic or transmit packet timing. To facilitate testing, the network's radio specification allows several test modes for transmitting continuous carrier without modulation, or with modulation generated from scrambler sequence or fixed sequence data. The transmit test modes were used for testing the radio for compliance to CFR47 standards. SYSTEM DESCRIPTION CONTINUED The R902M-2-O Radio Modem Device FUNCTIONAL DESCRIPTION The R902M-2-O is a 900 MHz band, half duplex ( two frequency simplex), 2 Watt, transceiver system for wireless data modem communications on Mobitex wireless systems. The transmitter is capable of transmitting on frequencies from 896 MHz to 902 MHz with a 12.5 KHz resolution. The active receive and transmit frequencies are determined by the radio firmware for nationally allocated Mobitex system channels and by the Bell South Wireless Data system for operational local channels. The user is not able to modify the frequency of operation of the device. The transmitter is capable of the generation of RF power at several calibrated levels. The levels are 2,000 milliwatts, 1,000 milliwatts, 500 milliwatts, 250 milliwatts, 125 milliwatts, and 60 milliwatts: (+33, +30, +27, +24, +21, +18 dBm respectively ). The various power levels are used to balance the receive and transmit radio link. The power level is controlled by the Mobitex system in response to the received signal strength and power level instructions received. The output power level of the device cannot be modified by the user SYSTEM DESCRIPTION; CONTINUED TEST SETUP FOR: SPURIOUS RADIATED EMISSIONS TEST PROCEDURE: RADIATED EMISSIONS All tests were performed in accordance with FCC/MP-4, & ANSI C63.4. The Research In Motion Ltd. 900 MHz radio modem device model R902M-2-O, was connected together with a host IBM laptop computer, Epson printer, ECLIPSE II magnet mount cellular antenna Model 9123 and a RIM Model 02120-001 radio monitor board as described on the “Title and System Description” pages. The system was arranged in a typical configuration of use and placed on top of a one metre non-conducting turntable as per ANSI C63.4. All of the system parts were connected together with cables that are sold with each piece or generic cables purchased for the specific connection involved. Several different equipment placements were tried so as to establish the worst normal case of equipment positioning. In this case the 02120-001 radio monitor board, laptop computer, RF radio, Epson printer, and RF antenna were placed on top of the turntable. The power supply was placed at the bottom centre of the test table. All of the cables and cords were moved about so as to create the highest level of EMI. The complete system was operating as it would be in normal use. Special software was employed in order that the 900 MHz Packet Data Radio, model R902M-2-O was processing data in a worst case normal manner. The turntable was rotated through 360 degrees. A preliminary radio frequency scan was performed on the system to determine the worst case cable and equipment configuration. The attached results represent the system configuration maximized for worst case emissions in each frequency band. Please refer to the System Description. The tests we…

Text truncated - open the document above for the full version.

Test Report

FCC PARTS 2 & 90, Subpart I, Radio Services Transmitters Page 1 Radio Transceiver, Model RM20M FCC ID: PASRM20M ULTRATECH GROUP OF LABS File #: PWL8-FTX 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: [email protected] , Website: http://www.ultratech-labs.com • Assessed by ITI (UK) Competent Body, NVLAP (USA) Accreditation Body & ACA/AUSTEL (Australia), VCCI (Japan) • Accredited by Industry Canada (Canada) under ACC-LAB (Europe/Canada MRA and APEC/Canada MRA) • Recognized/Listed by FCC (USA) • All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST 1. TRANSMITTER SPURIOUS/HARMONIC RADIATED EMISSIONS @ FCC 90.210 1.1. LIMITS @ FCC 90.210 Emissions shall be attenuated below the mean output power of the transmitter as follows: FCC RULES WORST CASE EMISSIONS LIMIT ATTENUATION LIMIT (dBc) FCC 90.210 (j) FCC 90.210 (j) 50 + 10log(P), P is in Watts 1.2. METHOD OF MEASUREMENTS Refer to TIA/EIA-603, Section 2.2.12. 1.3. TEST EQUIPMENT LIST Test Instruments Manufacturer Model No. Serial No. Frequency Range Spectrum Analyzer/ EMI Receiver Advantest R3271 15050203 100 Hz to 32 GHz with external mixer for frequency above 32 GHz Spectrum Analyzer/ EMI Receiver Hewlett Packard HP 8593EM 3412A00103 9 kHz – 26.5 GHz RF Pre-Amplifier Com-Power PA-102 1425 30 MHz to 1 GHz, 30 dB gain nominal Microwave Amplifier Hewlett Packard HP 83017A 3116A00661 1 GHz to 26.5 GHz, 30 dB nominal Biconilog Antenna EMCO 3142 10005 30 MHz to 2 GHz Dipole Antenna EMCO 3121C 8907-434 30 – 1000 MHz Dipole Antenna EMCO 3121C 8907-440 30 – 1000 MHz Horn Antenna EMCO 3155 9701-5061 1 GHz – 18 GHz Horn Antenna EMCO 3155 9911-5955 1 GHz – 18 GHz RF Signal Generator Hewlett Packard HP 83752B 3610A00457 0.01 – 20 GHz FCC PARTS 2 & 90, Subpart I, Radio Services Transmitters Page 2 Radio Transceiver, Model RM20M FCC ID: PASRM20M ULTRATECH GROUP OF LABS File #: PWL8-FTX 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: [email protected] , Website: http://www.ultratech-labs.com • Assessed by ITI (UK) Competent Body, NVLAP (USA) Accreditation Body & ACA/AUSTEL (Australia), VCCI (Japan) • Accredited by Industry Canada (Canada) under ACC-LAB (Europe/Canada MRA and APEC/Canada MRA) • Recognized/Listed by FCC (USA) • All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST 1.4. TEST DATA Carrier Frequency (MHz): 896 ERP (dBm): 28.8 Limit (dBc): -48.8 Frequency E-Field EMI Detector Antenna Polarization ERP measured by Substitution Method Limit Margin (MHz) (dBμV/m) (Peak/QP) (H/V) (dBm) (dBc) (dBc) (dB) 3584 65.83 Peak V -33.20 -62.00 -48.8 -13.2 4480 62.78 Peak V -35.50 -64.30 -48.8 -15.5 The emissions were scanned from 10 MHz to 10 GHz and all emissions within 20 dB below the limits were recorded. Carrier Frequency (MHz): 901 ERP (dBm): 30.0 Limit (dBc) -50.0 Frequency E-Field EMI Detector Antenna Polarization ERP measured by Substitution Method Limit Margin (MHz) (dBμV/m) (Peak/QP) (H/V) (dBm) (dBc) (dBc) (dB) 3604 64.03 Peak V -34.2 -64.2 -50.0 -14.2 4505 62.22 Peak V -35.7 -65.7 -50.0 -15.7 The emissions were scanned from 10 MHz to 10 GHz and all emissions within 20 dB below the limits were recorded.

Test Setup Photos

               ! "#$                  !  #$                     ! %#$                 ! &#$                 ! '#$                 ! $#$   

Contact Information

Applicant

Mamdouh Yanni(Hardware Design Engineer)
[email protected]905-882-3130Fax: 905-882-3149

Technical Contact

Ultratech Engineering Labs Inc.Tri M Luu
[email protected]1-877-765-4173

3000 Bristol Circle · Oakville, Ontario · Canada

Non-Technical Contact

Ultratech Engineering Labs Inc.Tri M Luu
[email protected]1-877-765-4173

Test Firm

UltraTech Engineering Labs Inc.Tri Luu
[email protected]877-747-6381Fax: 905-829-8050

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
190896 MHz - 901 MHz2 W12K8F1D1.5000000000 ppm
Confidentiality
Long Term

Other Applications from Destinator Technologies Inc. (Canada)

PERSONAL LOCATION DEVICE - FCC ID PAS-PLD141 - Destinator Technologies Inc. (Canada)
PAS-PLD141

PERSONAL LOCATION DEVICE

Mar 21, 2005

Equipment Class

PCT - PCS Licensed Transmitter worn on body
PowerLOC Mobile Device, Model VLD103 - FCC ID PASVLD103 - Destinator Technologies Inc. (Canada)
PASVLD103

PowerLOC Mobile Device, Model VLD103

Mar 07, 2001

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter