Delta Electronics, Inc.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jun 16, 2026
Application Purpose
Original Equipment
Equipment Note
Indoor Wireless AP
Frequency Range
2402.00000000 - 2480.00000000
Company
Delta Electronics, Inc.
Country
Taiwan

Documents & Files

Select a file to view

Attestation Statements

β†—
β†—
β†—
β†—

Cover Letter(s)

β†—
β†—
β†—

ID Label/Location Info

β†—

RF Exposure Info

β†—
β†—
β†—

Test Report

β†—
β†—
β†—
β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Delta Electronics, Inc. 31-1 Shien Pan Rd., Kuei San Industrial Zone, Taoyuan City, 333, Taiwan U.S. Agent for Service of Process Attestation To the attention of Federal Communications Commission Authorization and Evaluation Division U.S. Agent Company Name: Nile Global, Inc FRN: 0031648819 Contact Name: Pankaj Patel Street Address:3590 N 1ST St Ste 300 San Jose, City/Province/Zip: CA, 95134 United States Telephone No: (669) 369-6453 Email: [email protected] This letter is to confirm that we have accepted the responsibility to act as the designated U.S. Agent for service of process as required by Β§2.911(d)(7) on behalf of the Applicant noted below. U.S. Agent Signature: Date: 2026-05-21 Signed by (printed name):Pankaj Patel Applicant Company name: Delta Electronics, Inc. FRN: 0029041993 Grantee Code or FCC ID: PD5-NWA1200 Contact Name: Payton Ting Street Address: 31-1 Shien Pan Rd., Kuei San Industrial Zone, City/Province/Zip: Taoyuan City, 333, Taiwan Telephone No: 886-3-4526107 # 8095 Email: [email protected] This letter is to confirm that the Applicant has designated the U.S Agent noted above for the purpose of accepting service of process on their behalf as required by Β§2.911(d)(7). The Applicant further acknowledges acceptance to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission- related proceeding involving the equipment. Applicant Signature: Date: 2026-05-21 Signed by (printed name):Payton Ting

Attestation Statements

Delta Electronics, Inc. 31-1 Shien Pan Rd., Kuei San Industrial Zone, Taoyuan City, 333, Taiwan Rev 1/26/2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2026-05-19 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: PD5-NWA1200 Delta Electronics, Inc. certifies that the equipment for which authorization is sought is not β€œcovered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Delta Electronics, Inc. certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Sincerely, ----------------------------------- Payton Ting, Manager Delta Electronics, Inc. Tel: 886-3-4526107 # 8095 Fax: 886-3-4527314 E-mail: [email protected] Delta Electronics, Inc. 31-1 Shien Pan Rd., Kuei San Industrial Zone, Taoyuan City, 333, Taiwan Rev 1/26/2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2026-03-03 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: PD5-NWA1200 Delta Electronics, Inc. certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing β€œcovered” equipment. Sincerely, ----------------------------------- Payton Ting, Manager Delta Electronics, Inc. Tel: 886-3-4526107 # 8095 Fax: 886-3-4527314 E-mail: [email protected]

Attestation Statements

Delta Electronics, Inc. 31-1 Shien Pan Rd., Kuei San Industrial Zone, Taoyuan City, 333, Taiwan P R O F E S S I O N A L I N S T A L L A T I O N A T T E S T A T I O N Date: 2026-05-28 FCC ID: PD5-NWA1200 We, Delta Electronics, Inc. hereby declare that requirements of KDB 353028 D01 Antennas Part 15 Transmitters v01 have been met and shown on the following questions. Further we declare that the info listed below are correct and represent the product in consideration under this filing. 1. Professional installation must be justified. Description: Device is indoor Access Point and must need special trained professional in configuring and installing the product, more details please refer to user manual exhibit. 2. Professional installation does not permit use of any antenna with the transmitter; the permitted types of antenna specified as below. Description: Below listed of Antennas has been compliance FCC Rule Part 15 requirement, more details please refer to test reports. Delta Electronics, Inc. 31-1 Shien Pan Rd., Kuei San Industrial Zone, Taoyuan City, 333, Taiwan 3. The applicant should address the following items when justifying professional installation. (1) To qualify for professional installation, please explain why the hardware is not readily available to average consumer. Description: Due to this product and will not be sold directly to the general public through retail store, therefore the hardware is not readily available to average consumer. Delta Electronics, Inc. 31-1 Shien Pan Rd., Kuei San Industrial Zone, Taoyuan City, 333, Taiwan (2) Marketing β€” Applicant must ensure device cannot be sold via retail to the general public or by mail order. Description: This product and will not be sold directly to the general public through retail store. It will be sold to authorized dealers or installers only. Delta Electronics, Inc. 31-1 Shien Pan Rd., Kuei San Industrial Zone, Taoyuan City, 333, Taiwan (3) Applicant must show that device intended use is not for consumers and general public. Description: Device is for industrial/commercial use. (4) Explain what is unique, sophisticated, complex, or specialized about the equipment that REQUIRES it to be installed by a professional installer? Description: This product and will not be sold directly to the general public through retail store 4. Other professional installation requirements (1) Installation must be controlled. Description: The product will be distributed through controlled distribution channel which has special trained professional to install this product (2) Installed by licensed professionals. Description: Device sold to dealer who hires installers and need special trained professional in configuring and installing the product. (3) Installation requires special training. Description: The product need special programming, access to keypad, field strength measurements made, so must need special trained professional in configuring and installing the product. If you should have any question(s) regarding this declaration, please don’t hesitate to contact us. Thank you!

Attestation Statements

Delta Electronics, Inc. 31-1 Shien Pan Rd., Kuei San Industrial Zone, Taoyuan City, 333, Taiwan Date: May 19, 2026 We, Delta Electronics, Inc., declare that the device does not support channel 12 ~ 13 in 2.4GHz band and any non-US channels in all the operational mode(s) for the following product. FCC ID: PD5-NWA1200 If you should have any question(s) regarding this declaration, please don’t hesitate to contact us. Thank you! ----------------------------------- Payton Ting, Manager Delta Electronics, Inc. Tel: 886-3-4526107 # 8095 Fax: 886-3-4527314 E-mail: [email protected]

Cover Letter(s)

Delta Electronics, Inc. 31-1 Shien Pan Rd., Kuei San Industrial Zone, Taoyuan City, 333, Taiwan Date: 2026-05-19 FCC ID: PD5-NWA1200 A U T H O R I Z A T I O N L E T T E R To Whom It May Concern: Delta Electronics, Inc. hereby authorizes Emerald Chen / Specialist of Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch (β€œBV CPS Taoyuan”), to act on its behalf in all matters relating to the Federal Communication Commission (β€œFCC”) application for equipment authorization in connection with the FCC ID listed above, including signing of all documents relating to these matters. Any and all acts carried out by Emerald Chen / Specialist of BV CPS Taoyuan on Delta Electronics, Inc.’s behalf, within the scope of the powers granted herein, shall have the same effect as acts of its own. If you have any questions regarding the authorization, please don’t hesitate to contact us. Sincerely yours, ----------------------------------------------- Payton Ting, Manager Delta Electronics, Inc. Tel: 886-3-4526107 # 8095 Fax: 886-3-4527314 E-mail: [email protected]

Cover Letter(s)

Delta Electronics, Inc. 31-1 Shien Pan Rd., Kuei San Industrial Zone, Taoyuan City, 333, Taiwan Date: 2026-06-02 FCC ID: PD5-NWA1200 To the attention of Federal Communications Commission Authorization and Evaluation Division Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the commission’s rules, we request short-term confidential treatment for the following information until 180 days after the Grant Date of Equipment Authorization) in order to ensure sensitive business information remains confidential until the actual marketing of the device: External photos Internal Photos Test Setup photos User’s manual Sincerely yours, ----------------------------------- Payton Ting, Manager Delta Electronics, Inc. Tel: 886-3-4526107 # 8095 Fax: 886-3-4527314 E-mail: [email protected]

Cover Letter(s)

Delta Electronics, Inc. 31-1 Shien Pan Rd., Kuei San Industrial Zone, Taoyuan City, 333, Taiwan Date: 2026-05-19 FCC ID: PD5-NWA1200 To the attention of Federal Communications Commission Authorization and Evaluation Division Permanent Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, the Applicant hereby requests confidential treatment of information accompanying this Application as outlined below: Schematics Block Diagram Operational Description Operational Description-SDR Software Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457, disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely yours, ----------------------------------- Payton Ting, Manager Delta Electronics, Inc. Tel: 886-3-4526107 # 8095 Fax: 886-3-4527314 E-mail: [email protected]

ID Label/Location Info

FCC ID: PD5-NWA1200 IC: 3970A-NWA1200 The label will be permanently affixed and readily visible. Label: Label location Bottom of EUT

RF Exposure Info

Report No.: MFBAPP-WTW-P25120629 Page No. 1 / 14 Report Format Version: 7.1.0 Reference No.: BAPP-WTW-P25120629 RF EXPOSURE REPORT CERTIFICATE OF CONFORMITY FCC Rule Part: FCC Part 2 (Section 2.1091) Report No.: MFBAPP-WTW-P25120629 FCC ID: PD5-NWA1200 Product: Indoor Wireless AP Brand: Nile Global Model No.: NWA1200 Received Date: 2025/12/22 Test Date: 2026/4/7 ~ 2026/5/15 Issued Date: 2026/6/3 Applicant: Delta Electronics, Inc. Address: No.31-1, Shien Pan Rd., Kuei San District, Taoyuan City 33341, Taiwan Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Lin Kou Laboratories Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City 33383, Taiwan FCC Registration / Designation Number: 788550 / TW0003 Approved by: , Date: 2026/6/3 Jeremy Lin / Project Engineer This test report consists of 14 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The test results in the report only apply to the tested sample. The test results in this report are traceable to the national or international standards. Prepared by : Gina Liu / Specialist This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our- business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Report No.: MFBAPP-WTW-P25120629 Page No. 2 / 14 Report Format Version: 7.1.0 Reference No.: BAPP-WTW-P25120629 Table of Contents Release Control Record ....................................................................................................................................................... 3 1 Certificate .................................................................................................................................................................... 4 2 Measurement Uncertainty ......................................................................................................................................... 5 3 Test Instruments ........................................................................................................................................................ 5 4 Applicable RF Exposure Limit .................................................................................................................................. 6 5 Test Results .............................................................................................................................................................. 10 6 Conclusion ................................................................................................................................................................ 13 7 Information of the Testing Laboratories ................................................................................................................ 14 Report No.: MFBAPP-WTW-P25120629 Page No. 3 / 14 Report Format Version: 7.1.0 Reference No.: BAPP-WTW-P25120629 Release Control Record Issue No. Description Date Issued MFBAPP-WTW-P25120629 Original release. 2026/6/3 Report No.: MFBAPP-WTW-P25120629 Page No. 4 / 14 Report Format Version: 7.1.0 Reference No.: BAPP-WTW-P25120629 1 Certificate Product: Indoor Wireless AP Brand: Nile Global Test Model: NWA1200 Sample Status: Engineering sample Applicant: Delta Electronics, Inc. Test Date: 2026/4/7 ~ 2026/5/15 FCC Rule Part: FCC Part 2 (Section 2.1091) Standard: KDB 447498 D04 Interim General RF Exposure Guidance v01 The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s RF characteristics under the conditions specified in this report. Report No.: MFBAPP-WTW-P25120629 Page No. 5 / 14 Report Format Version: 7.1.0 Reference No.: BAPP-WTW-P25120629 2 Measurement Uncertainty Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the EUT. Measurement Specification Expanded Uncertainty (k=2) (Β±) RF Exposure 1 GHz ~ 2.5 GHz 1.2 dB 2.5 GHz ~ 8 GHz 1.3 dB 3 Test Instruments The calibration interval of the all test instruments are 12 months and the calibrations are traceable to NML/ROC and NIST/USA. Routine Evaluation Routin…

Text truncated - open the document above for the full version.

RF Exposure Info

CERTIFICATE OF CALIBRATION Number NE25/03017 Page 1 of 5 pages LabCal - Wavecontrol Radio-electric Calibration Laboratory C/ Pallars 65-71 08018 Barcelona This certificate has been issued by digital signature, any print of it will be considered a copy. ITEM EM Field Meter + Isotropic EM Field Probe BRAND Wavecontrol MODEL Meter: SMP2 Probe: WPF60 IDENTIFICATION Meter: 22SN1914 Probe: 22WP230188 APPLICANT Bureau Veritas Consumer Products Services (Hong Kong) No. 19, Huaya 2nd Rd., Guishan Dist., Taoyuan City 33383, Taiwan 33383 Taoyuan City (Taiwan) DATE/S OF CALIBRATION 18/06/2025 Authorized Signatories Date of issue: 19/06/2025 David Guayerbas Laboratory Technician Laboratory Director CERTIFICATE OF CALIBRATION Number: NE25/03017 Page 2 of 5 This certificate has been issued by digital signature, any print of it will be considered a copy. Measurement: The calibration of field strength monitors involves the generation of a known linearly polarised electromagnetic field, approximating to a plane wave, into which the probe or sensor is placed. The probe is positioned on a low reflectivity mount inside a microwave anechoic chamber on the bore sight of a linearly polarised horn antenna. The probe under test is always perpendicular to the direction of propagation and parallel to the electric field. The follow parameter is obtained: Correction factor (CF) For each measurement, the input power to the test facility is adjusted so that the actual field strength is set to a specific value. The field strength indicated by the probe under calibration is then read and the correction factor calculated using the following definition: 퐢퐹= ν΄ν‘ν‘‘ν‘’ν‘Žν‘™ 퐹푖푒푙푑 ν‘†ν‘‘ν‘Ÿν‘’ν‘›ν‘”ν‘‘β„Ž νΌν‘›ν‘‘ν‘–ν‘ν‘Žν‘‘ν‘’ν‘‘ 퐹푖푒푙푑 ν‘†ν‘‘ν‘Ÿν‘’ν‘›ν‘”ν‘‘β„Ž 퐢퐹 2 = ν΄ν‘ν‘‘ν‘’ν‘Žν‘™ ν‘ƒν‘œν‘€ν‘’ν‘Ÿ 퐷푒푛푠푖푑푦 νΌν‘›ν‘‘ν‘–ν‘ν‘Žν‘‘ν‘’ν‘‘ ν‘ƒν‘œν‘€ν‘’ν‘Ÿ 퐷푒푛푠푖푑푦 The indicated field strength must be multiplied by the appropriate correction factor to give the actual field strength. CERTIFICATE OF CALIBRATION Number: NE25/03017 Page 3 of 5 This certificate has been issued by digital signature, any print of it will be considered a copy. Reference standards: IEEE Std 1309:2013 β€œStandard for Calibration of Electromagnetic Field Sensors and Probes, Excluding Antennas, from 9 kHz to 40 GHz”. Uncertainties: The uncertainty of calibration for this device at the calibrated frequency is as follows: 60 – 90 GHz: Β± 4.2 dB The measurement uncertainties above apply only when the probe is supported in a low reflectivity mount. The user should be aware of the effects of reflections from nearby objects, including human body, and should allow additional measurement uncertainties accordingly. The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor k = 2, providing a level of confidence of approximately 95 %. The uncertainty evaluation has been carried out in accordance with the EA-4/02 M document. Environmental conditions: Humidity Temperature (50 Β± 20) % rH (23 Β± 2) ΒΊC The uncertainties refer to the measured devices only. They relate to the on-the-day values and make no allowance for drift or operation under other environmental conditions. Procedure: PC-1206 – Calibration of electric field probes in the range 800 MHz – 40 GHz This method follows the Standard probe method. A reference probe is used to measure and calibrate the field used for calibrating the probe under calibration. Calibration engineer: David Guayerbas CERTIFICATE OF CALIBRATION Number: NE25/03017 Page 4 of 5 This certificate has been issued by digital signature, any print of it will be considered a copy. Calibration set-up: Position 1: Display of the meter facing to direction of propagation Position 2: Probe rotated 90ΒΊ from Position 1 Figure 1: Calibration set-up in the anechoic chamber CERTIFICATE OF CALIBRATION Number: NE25/03017 Page 5 of 5 This certificate has been issued by digital signature, any print of it will be considered a copy. Results: The correction factors (CF) for each position and the average correction factor are given. This average correction factor must be applied to the measured value for the total field. The average correction factor is the arithmetic mean of the correction factors for the two positions. The correction factors given below must be multiplied by the measured value for the field in order to obtain the actual field value: Position 1Position 2Position 1Position 2Mean 6000021.3110.9611.901.941.791.87 Freq. (MHz) Actual Field (V/m) Measured Field (V/m)CF Frequency response

RF Exposure Info

CERTIFICATE OF CALIBRATION Number 25/12245 Page 1 of 8 pages LabCal - Wavecontrol Radio-electric Calibration Laboratory C/ Pallars 65-71 08018 Barcelona This certificate is issued in accordance with the conditions of accreditation granted by ENAC, according to standard ISO 17025, which has assessed the measurement capability of the laboratory and its traceability to national standards. ENAC is one of the signatories of the Multilateral Agreement of the European Cooperation for Accreditation (EA) and the International Laboratories Accreditation Cooperation (ILAC). This certificate has been issued by digital signature, any print of it will be considered a copy. ITEM EM Field Meter + Isotropic EM Field Probe BRAND Wavecontrol MODEL Meter: SMP2 Probe: WPF60 IDENTIFICATION Meter: 22SN1914 Probe: 22WP230188 APPLICANT Bureau Veritas Consumer Products Services (Hong Kong) No. 19, Huaya 2nd Rd., Guishan Dist., Taoyuan City 33383, Taiwan 33383 Taoyuan City (Taiwan) DATE/S OF CALIBRATION 18/06/2025 Authorized Signatories Date of issue: 19/06/2025 David Guayerbas Laboratory Technician Laboratory Director CERTIFICATE OF CALIBRATION Number: 25/12245 Page 2 of 8 This certificate has been issued by digital signature, any print of it will be considered a copy. Measurement: The calibration of field strength monitors involves the generation of a known linearly polarised electromagnetic field, approximating to a plane wave, into which the probe or sensor is placed. Over the frequency range of 1 – 800 MHz, an absorber loaded TEM cell is used to generate the known field. The probe under test is positioned parallel to the electric field and perpendicular to the direction of propagation. Over the frequency range of 800 MHz – 40 GHz the probe is positioned on a low reflectivity mount inside a microwave anechoic chamber on the bore sight of a linearly polarised horn antenna. The probe under test is always perpendicular to the direction of propagation and parallel to the electric field. Three calibration parameters are obtained: 1- Correction factor (CF) For each measurement, the input power to the test facility is adjusted so that the actual field strength is set to a specific value. The field strength indicated by the probe under calibration is then read and the correction factor calculated using the following definition: 퐢퐹= ν΄ν‘ν‘‘ν‘’ν‘Žν‘™ 퐹푖푒푙푑 ν‘†ν‘‘ν‘Ÿν‘’ν‘›ν‘”ν‘‘β„Ž νΌν‘›ν‘‘ν‘–ν‘ν‘Žν‘‘ν‘’ν‘‘ 퐹푖푒푙푑 ν‘†ν‘‘ν‘Ÿν‘’ν‘›ν‘”ν‘‘β„Ž 퐢퐹 2 = ν΄ν‘ν‘‘ν‘’ν‘Žν‘™ ν‘ƒν‘œν‘€ν‘’ν‘Ÿ 퐷푒푛푠푖푑푦 νΌν‘›ν‘‘ν‘–ν‘ν‘Žν‘‘ν‘’ν‘‘ ν‘ƒν‘œν‘€ν‘’ν‘Ÿ 퐷푒푛푠푖푑푦 The indicated field strength must be multiplied by the appropriate correction factor to give the actual field strength. 2- Linearity The linearity can be calculated as the variation of the Correction Factor as a function of the field strength applied to the probe for a frequency value. 3- Frequency response The frequency response can be calculated as the variation of the Correction Factor as a function of the frequency for a fixed field value applied to the probe. Traceability: NPL (National Physical Laboratory) CERTIFICATE OF CALIBRATION Number: 25/12245 Page 3 of 8 This certificate has been issued by digital signature, any print of it will be considered a copy. Reference standards: IEEE Std 1309:2013 β€œStandard for Calibration of Electromagnetic Field Sensors and Probes, Excluding Antennas, from 9 kHz to 40 GHz”. Uncertainties: The uncertainty of calibration for this device is as follows: The measurement uncertainties above apply only when the probe is supported in a low reflectivity mount. The user should be aware of the effects of reflections from nearby objects, including human body, and should allow additional measurement uncertainties accordingly. The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor k = 2, providing a level of confidence of approximately 95 %. The uncertainty evaluation has been carried out in accordance with the EA-4/02 M document. Environmental conditions: Humidity Temperature (50 Β± 20) % rH (23 Β± 2) ΒΊC The uncertainties refer to the measured devices only. They relate to the on-the-day values and make no allowance for drift or operation under other environmental conditions. Procedure: PC-1205 – Calibration of electric field probes in the range 100 kHz – 800 MHz PC-1206 – Calibration of electric field probes in the range 800 MHz – 40 GHz Both methods follow the Standard probe method. A reference probe is used to measure and calibrate the field used for calibrating the probe under calibration. Calibration engineer: David Guayerbas 1 MHz - 10 MHz: Β± 1.2dB 10 MHz - 300 MHz: Β± 1.3dB 300 MHz – 500 MHz: Β± 1.1dB 500 MHz - 800 MHz:Β± 1.5dB 800 MHz - 1 GHz: Β± 1.2dB 1 GHz - 2.5 GHz: Β± 1.2dB 2.5 GHz - 8 GHz:Β± 1.3dB 8 GHz - 18 GHz:Β± 1.8dB 18 GHz - 40 GHz:Β± 2.8dB CERTIFICATE OF CALIBRATION Number: 25/12245 Page 4 of 8 This certificate has been issued by digital signature, any print of it will be considered a copy. Calibration set-up: Figure 1: Calibration set-up in the absorber loaded TEM cell Figure 2: Calibration set-up in the anechoic chamber CERTIFICATE OF CALIBRATION Number: 25/12245 Page 5 of 8 This certificate has been issued by digital signature, any print of it will be considered a copy. The position of the probe inside the TEM cell is specified in Figure 1. The main axis of the probe is parallel to the cell walls. The probe is positioned on the bore sight of the horn antenna inside the anechoic chamber, at the distance and height specified in Figure 2. The position and orientation of the probe relative to the applied field to calibrate the 3 axis is specified in Figure 3. Figure 3: Position and orientation of the probe CERTIFICATE OF CALIBRATION Number: 25/12245 Page 6 of 8 This certificate has been issued by digital signature, any print of it will be considered a copy. Results: The correction factors (CF) for the requested calibration points are shown below. The correction factors for each axis and the average correction factor are given. This average correction factor must be applied to the measured value for the total field…

Text truncated - open the document above for the full version.

Test Report

Report No.: RFBAPP-WTW-P25120629-1 Page No. 1 / 117 Report Format Version: 7.2.0 Reference No.: BAPP-WTW-P25120629 TEST REPORT CERTIFICATE OF CONFORMITY Standard: 47 CFR FCC Part 15, Subpart C (Section 15.247) Report No.: RFBAPP-WTW-P25120629-1 FCC ID: PD5-NWA1200 Product: Indoor Wireless AP Brand: Nile Global Model No.: NWA1200 Received Date: 2025/12/22 Test Date: 2026/1/6 ~ 2026/5/12 Issued Date: 2026/6/3 Applicant: Delta Electronics, Inc. Address: No.31-1, Shien Pan Rd., Kuei San District, Taoyuan City 33341, Taiwan Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Lin Kou Laboratories Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City 33383, Taiwan FCC Registration / Designation Number: 788550 / TW0003 Approved by: , Date: 2026/6/3 Jeremy Lin / Project Engineer This test report consists of 117 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The test results in the report only apply to the tested sample. The test results in this report are traceable to the national or international standards. Prepared by : Gina Liu / Specialist This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our- business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Report No.: RFBAPP-WTW-P25120629-1 Page No. 2 / 117 Report Format Version: 7.2.0 Reference No.: BAPP-WTW-P25120629 Table of Con…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Payton Ting(Manager)
[email protected]Fax: 886-3-3206365

Technical Contact

Nile Global, Inc.Pankaj Patel
[email protected]

3590 N 1st St Β· San Jose, California, 95134 Β· United States

Test Firm

Bureau Veritas CPS(H.K.) Ltd., Taoyuan BranchLiu Ken
[email protected]Fax: +886-3-2115834

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz707.00 mW
215C2.42 GHz - 2.45 GHz136.00 mW
315C2.40 GHz - 2.48 GHz3.00 mW
Software Defined Radio
Yes
Confidentiality
Long Term
Grant Notes
Output Power listed is the maximum combined conducted output power. Professional installation is required. This device must be installed and operated so as to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. End-users must be informed of operating requirements for satisfying RF exposure compliance. This device supports 20 and 40 MHz bandwidth modes. Device operation is limited to indoor use only.

Other Applications from Delta Electronics, Inc.

PD5-AP743

802.11be enterprise access point

Jun 03, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
PD5-AP623E

802.11ax enterprise access point

Sep 04, 2025

Equipment Class

NII - Unlicensed National Information Infrastructure TX
802.11 b/g/n/ac WIFI AP - FCC ID PD5-LM-WESA04OR - Delta Electronics, Inc.
PD5-LM-WESA04OR

802.11 b/g/n/ac WIFI AP

Aug 01, 2021

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Wireless Access Point - FCC ID PD5-NWA1000 - Delta Electronics, Inc.
PD5-NWA1000

Wireless Access Point

Jul 25, 2021

Equipment Class

NII - Unlicensed National Information Infrastructure TX
BT Module - FCC ID PD5-NSW1000BLE - Delta Electronics, Inc.
PD5-NSW1000BLE

BT Module

Feb 07, 2021

Equipment Class

DTS - Digital Transmission System