  2. Leeds Electronic Engineering LTD/
  3. PDB-LS100-0-2

PDB-LS100-0-2

Leeds Electronic Engineering LTD
DSC - Part 15 Security/Remote Control Transmitter - FCC ID PDB-LS100-0-2 - Leeds Electronic Engineering LTD
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Dec 21, 2000
Application Purpose
Original Equipment
Date of Application
Nov 26, 2000
Frequency Range
433.70000000 - 433.70000000
Company
Leeds Electronic Engineering LTD
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

LS2500 WIRELESS SECURITY SYSTEM INSTALLATION GUIDE COMMERCIAL CONFIDENTIAL I. Installation Guide DIY Installation Guide 1.Suggested Location of Main Console and Accessories 2.Mounting Height and Detection Range of PIR 3.Magnetic Switch Location 60 0 60 0 PIR 012345678910 2~2.5 meter (meter) WALL FLOOR PIR (6~8 feet) CEILING KITCHEN FRONT DOOR Magnetic Switch CHILDREN'S ROOM DINING ROOM Optional PIR Optional Magnetic Switch WINDOW WINDOW PIR SITTING ROOM Main Console BEDROOM STUDY ROOM Optional Smoke Detector Magnet Magnetic Switch Detector DOORDOOR Magnet Magnetic Switch Detector External Magnetic Switch less than 10mm less than 10mm Regular Shaped Door-Frame Installation Irregular Shaped Door-Frame Installation 4.Installation of Main Console a) Slacken the two screws at the base of the Main Console and open the back cover. b) Push the slide switch to the “OFF” position. c) Make connection to the terminals as shown in the diagram. d) Plug a 9V ALKALINE battery (not included) in the battery snap. e) Connect the automatic dialer to the connectors with wiring cable provided. f1)Take off the double-sided glue-tape paper on the back cover, and stick it on the chosen locationor f2)Leave the double-sided glue-tape on the back cover, mount the Main Console with the screws provided through the screw-mounting holes as shown in the diagrams. g)Replace and screw the Main Console to the back cover h) Plug the AC Adaptor to the Main Power Outlet Reset Battery Housing Terminals Connector for AD2510 Auto voice dialer wiring cable + 12V - DC IN + 12V - DC OUT TRIGG EXT SP Tie a knot here Tie a knot here AC/DC ADAPTOR EXTENSION SIREN SPEAKER LS1004 RED BLACK } OUTHOME OFF 0 456 123 879 Numbers Slide Switch LED (For Model LS2500 - 1 kit) l Optional Connections IV. Connect the AD2510 automatic voice dialer with the wiring cable. V. Power supply (12V DC out). 12V DC IN 12V DC OUT EXT SP VI. Connect the external device. (e.g. COMBELL Siren/Strobe Unit) 12V DC IN TRIGGEXT SP TRIGG 12V DC OUT Dialer AD2510LS2500 Main Console Glue Tape Screw Hole Screw Hole Screw Glue Tape Screw Hole Screw Hole Glue Tape Flat Screw-Driver 5.Installation of PIR and Magnetic Switch a) PIR — insert a flat screw-driver into the bottom of PIR to open the back cover. Magnetic Switch — slacken the screw at the base. b) Plug a 9V ALKALINE battery in the battery slap. c1)Take off the double-sided glue-tape paper on the back covers, and stick them on the chosen locations or c2)Leave the double-sided glue-tape on the back covers, mount the units with the screws provided through the screw-mounting holes as shown in the diagrams. d)Replace the units to the back covers The Back Cover of PIR DetectorThe Back Cover of Magnetic Switch Caution:1. 9V ALKALINE battery is highly recommended for use in Main Console and all other accessories. 2.Don’t locate the PIR facing directly to window or heat source. 3.The Factory Code of the Main Console and Accessories is preset on the Mini-Switch. Don’t touch the Mini-Switch. L-shape plastic sealing piece L-shape plastic sealing piece Plug the H-shaped plastic connecting piece here to pair up the back plates BACK PLATE OF AD2510 AUTO VOICE DIALER BACK PLATE OF LS2500 MAIN CONSOLE Connecting diagram 1 for external siren/strobe (LS2500 MAIN CONSOLE TERMINALS) EXT SP 12V DC IN SIRENTAMPERSUPPLY (Connect to DC supply via the AC/DC adaptor provided) (for wiring to Leeds Extension Siren LS1004 only) (not used, if COMBELL is fitted) (COMBELL L083E TERMINALS) OUTIN STROBE 12V DC OUT TRIGG Connecting diagram 2 for external siren/strobe (LS2500 MAIN CONSOLE TERMINALS) EXT SP 12V DC IN 12V DC OUT TRIGG STROBETRIGGSUPPLYRTN (Connect to DC supply via the AC/DC adaptor provided) (for wiring to Leeds Extension Siren LS1004 only) (not used, if COMBELL is fitted) ("RTN" not used when connecting to LS2500 Main Console) (COMBELL L082E TERMINALS) } 978 OUTHOME OFF 0 456 123 VIII. Operation LS2500 OPERATION MANUAL A)Turn on Alarm System while Exiting the House 1)Push the slide switch to “OUT” position. 2) Close the door and leave the house within 30 seconds. 3) Both PIR & Magnetic Switch are activated for protection B) Switch off Alarm System when Entering the House 1) Enter your own four-digit PIN number within 15 seconds. (Note: The factory preset PIN no. is “1 2 3 4”. To change the PIN no., please see procedure “E”) 2)Push the slide switch to “OFF” position. C) When Inside the House 1) Push the slide switch to “HOME” position. 2) Magnetic Switch and optional Curtain-Lens PIR are activated to protect your door / window. D) Panic Alarm Press Buttons “1” and “9” together, alarm will sound immediately. E) Change PIN Number User is highly recommended to change the PIN number when uses it at the first time. 1)Push the slide switch to “OFF” position. 2)Key in the PIN numbers as follows: F)Alarm Hold After the Main Console was triggered and continued sounding for 3 minutes, the Alarm Hold Light (Red LED Indicator) turns on. To turn off the Red LED Indicator, do as follows: Red LED Numbers Slide Switch 1234 + 19 New PIN No. (e.g. 6789) Current PIN No. 1234067890 HOMEOUTOFF HOMEOUT OFF HOME OUT OFF OUTHOME OFF 1) Push the slide switch to “OFF” position. 2) Press Button “0”. Then wait for 5 seconds. Note:1.Any alarm can be stopped by pressing the valid four-digit PIN numbers. 2.Periodically beep sound in one and a half minute cycle from PIR or Magnetic Switch indicate that it is in low battery situation. Replace a new battery according to the Installation Manual. 3.In case you forget PIN number, press the “RESET” button inside the alarm unit (refer to the diagram in Installation Manual) to restore the PIN number to the factory default setting (1 2 3 4). _________________________________________________________________________________ Note : This equipment has been tested and found to comply with the limits for a Class B digital devices, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection again…

Text truncated - open the document above for the full version.

Attestation Statements

Oct. 29, 2000 FEDERAL COMMUNICATIONS COMMISSION 7435 Oakland Mills Road Columbia, MD 21046 USA Subject:Certification Application under FCC Part 15, Subpart C, Para. 15.231, Momentarily Operation in 433.70 MHz. Applicant:LEEDS ELECTRONIC ENGINEERING LTD. Product:WIRELESS WIRELESS PIR MOTION DETECTORS Model No.:LS1000 & LS1002 FCC ID:PDB-LS100-0-2 Dear Sir/Madam, As appointed agent for LEEDS ELECTRONIC ENGINEERING LTD., we would like to submit the application to the Federal Communications Commission for certification of the above product. Please review all necessary files uploaded to FCC OET site for detailed information. Models LS1000 and LS1002 are exactly identical in circuit design and packaging. The only difference is plastic sensor windows. Therefore, only a sample of Model LS1000 is selected for testing and representing for both models. Since the rf exposure safety distance is approximately 0.002 cm where the power density reach 0.29 mW/cm 2 and the antenna is enclosed within the case, the RF exposure risk is in-considerable. Therefore, the applicant wishes to apply for the exemption of meeting both the SAR test requirements per FCC OET Bulletin 65 and FCC RF Exposure Distance per 2.1093 If you have any queries, please do not hesitate to contact us. Yours truly, Tri Minh Luu, P. Eng., V.P., Engineering Encl 2 3000 Bristol Circle Oakville, Ontario, Canada L6H 6G4 Telephone (905) 829-1570 Facsimile (905) 829-8050 Website: www.ultratech-labs.com Email: [email protected] [email protected] UltraTech Group of Labs

Attestation Statements

FCC DECLARATION OF CONFORMITY (DoC) FCC DOC APPPLICATION:FCC Part 15, Subpart B MANUFACTURER’S NAME/ADDRESS:LEEDS ELECTRONIC ENGINEERING LTD. Flat B, 21/F, Yally Ind. Bldg., 6 Yip Fat St. Wong Chuk Hang, Hong Kong. US REPRESENTATIVE’S NAME/ADDRESS:APV Inc, APV Building, 1689 Production Circle, Riverside, CA. 92509. U.S.A. FCC ACCREDITED TEST LABORATORIES:UltraTech EMC Labs Inc. 3000 Bristol Circle Oakville, Ontario, Canada L6H 6G4 EQUIPMENT TYPE/ENVIRONMENT:Radio Receivers TRADE NAME / MODEL NO.: Main Console, Model LS2500 YEAR OF MANUFACTURE: 2000 COUNTRY OF MANUFACTURE:Hong Kong, China STANDARD(S) TO WHICH CONFORMITY IS DECLARED: A representative sample of the above products has been tested and found to following FCC requirements: FCC STANDARD FCC PART 15, SUBPART B, SECTION TEST REQUIREMENTSEQUIPMENT APPROVALFCC AUTHORIZATION FCC Part 15, Subpart B15.107(a)AC Powerline Conducted Emissions Radio Receivers Operating in 433.95 MHz Band Declaration of Conformity FCC Part 15, SubPart B15.109(a)Radiated EmissionsRadio Receivers Operating in 433.95 MHz Band Declaration of Conformity Notes: (1) For detailed information please refer to the engineering test report, UltraTech’s File No.: KCE-011C-FCCRX I, the undersigned, hereby declare that the equipment as tested is representative within manufacturing tolerance to units. ManufacturerLegal Representative in US Mr. Lui, Yun Tak MichaelMr. William Wong LEEDS ELECTRONIC ENGINEERING LTD.APV Inc. Flat B, 21/F, Yally Ind. Bldg., 6 Yip Fat St.APV Building, 1689 Production Circle, Wong Chuk Hang, Hong KongRiverside, CA. 92509, U.S.A. Phone #: (852) 2554-1261Phone #: 909 788-8081 Fax #: (852) 2873 1255Fax: 909 788-8084 Email Address: [email protected] Address: [email protected] LEEDS ELECTRONIC ENG LTD Flat “B” 21 st Floor, Yally Industrial Building, 6 Yip Fat Street, Wong Chuk Hang, H.K. Tel: (852) 25541261-2Fax: (852) 28731255Cable Address: “TRILEEDS” E-MAIL: leeds@netvigator .comWeb page: http//home.netvigator.com/~leeds CHINA FACTORY: DONGGUAN CONCORD ELECTRONIC PRODUCTS CO., LTD. Block 5, Shui Bai Huan Industrial District, Yon Gan Pu, Dong Guan, Guang Dong China Tel: 769-777 2369

Cover Letter(s)

Oct. 29, 2000 FEDERAL COMMUNICATIONS COMMISSION 7435 Oakland Mills Road Columbia, MD 21046 USA Subject:Certification Application under FCC Part 15, Subpart C, Para. 15.231, Momentarily Operation in 433.70 MHz. Applicant:LEEDS ELECTRONIC ENGINEERING LTD. Product:WIRELESS WIRELESS PIR MOTION DETECTORS Model No.:LS1000 & LS1002 FCC ID:PDB-LS100-0-2 Dear Sir/Madam, As appointed agent for LEEDS ELECTRONIC ENGINEERING LTD., we would like to submit the application to the Federal Communications Commission for certification of the above product. Please review all necessary files uploaded to FCC OET site for detailed information. Models LS1000 and LS1002 are exactly identical in circuit design and packaging. The only difference is plastic sensor windows. Therefore, only a sample of Model LS1000 is selected for testing and representing for both models. Since the rf exposure safety distance is approximately 0.002 cm where the power density reach 0.29 mW/cm 2 and the antenna is enclosed within the case, the RF exposure risk is in-considerable. Therefore, the applicant wishes to apply for the exemption of meeting both the SAR test requirements per FCC OET Bulletin 65 and FCC RF Exposure Distance per 2.1093 If you have any queries, please do not hesitate to contact us. Yours truly, Tri Minh Luu, P. Eng., V.P., Engineering Encl 2 3000 Bristol Circle Oakville, Ontario, Canada L6H 6G4 Telephone (905) 829-1570 Facsimile (905) 829-8050 Website: www.ultratech-labs.com Email: [email protected] [email protected] UltraTech Group of Labs

Cover Letter(s)

«Report_Date» FEDERAL COMMUNICATIONS COMMISSION 7435 Oakland Mills Road Columbia, MD 21046 U.S.A. Subject:Authority to Act as an Agent to FCC Applicant:LEEDS ELECTRONIC ENGINEERING LTD. Product:WIRELESS WIRELESS PIR MOTION DETECTORS Model No.:LS1000 & LS1002 FCC ID:PDB-LS100-0-2 Dear Sir/Madam, I hereby appoint UltraTech Engineering Labs Inc. (UltraTech) to act as my agent in preparation of this application to F.C.C. for authorization of equipment under F.C.C. Rules. I also certify that the information provided, properly described the device or system for which authorization is required. Regards LEEDS ELECTRONIC ENG LTD Flat “B” 21 st Floor, Yally Industrial Building, 6 Yip Fat Street, Wong Chuk Hang, H.K. Tel: (852) 25541261-2Fax: (852) 28731255Cable Address: “TRILEEDS” E-MAIL: leeds@netvigator .comWeb page: http//home.netvigator.com/~leeds CHINA FACTORY: DONGGUAN CONCORD ELECTRONIC PRODUCTS CO., LTD. Block 5, Shui Bai Huan Industrial District, Yon Gan Pu, Dong Guan, Guang Dong China Tel: 769-777 2369

Cover Letter(s)

Nov. 19, 2000 FEDERAL COMMUNICATIONS COMMISSION 7435 Oakland Mills Road Columbia, MD 21046 U.S.A. Subject: Request for withholding from public disclosure the schematic diagrams and system block diagrams pursuant to an application for certification. Applicant:LEEDS ELECTRONIC ENGINEERING LTD. Product:WIRELESS WIRELESS PIR MOTION DETECTORS Model No.:LS1000 & LS1002 FCC ID:PDB-LS100-0-2 Dear Sir/Madam, We, LEEDS ELECTRONIC ENGINEERING LTD, would like to request that the schematic diagrams and system block diagrams, labeled Exhibit 6, submitted with the application for certification be withheld from public disclosure as per Section 0.459 of FCC Rules. This request is made under the provisions of Section 0.457(d) of the Commission's Rules, and Section 552(b)(4) of the Freedom of Information Act. These sections authorize as a withholding from public inspection materials which would be privileged as a matter of law if retained by the person submitting them, and materials which would not customarily be released to the public by that person. The detailed confidential materials are listed as follows: No. Title 1Operational Description in Exhibit 20 2Block Diagram in Exhibit 17 3 Schematic Diagrams in Exhibit 18 . 4 Parts List in Exhibit 19 If you have any queries, please do not hesitate to contact us by: OUR TELEPHONE NO.:(852) 25541261 Yours truly, LEEDS ELECTRONIC ENG LTD Flat “B” 21 st Floor, Yally Industrial Building, 6 Yip Fat Street, Wong Chuk Hang, H.K. Tel: (852) 25541261-2Fax: (852) 28731255Cable Address: “TRILEEDS” E-MAIL: leeds@netvigator .comWeb page: http//home.netvigator.com/~leeds CHINA FACTORY: DONGGUAN CONCORD ELECTRONIC PRODUCTS CO., LTD. Block 5, Shui Bai Huan Industrial District, Yon Gan Pu, Dong Guan, Guang Dong China Tel: 769-777 2369

External Photos

Exhibit 11 – External Photos of the EUTPhoto # 1 WIRELESS WIRELESS PIR MOTION DETECTORS, Model No.: LS1000 & LS1002FCC ID: PDB-LS100-0-2 Note: Models LS1000 and LS1002 are exactly identical except for the slightly difference in size of the plastic sensor window Model LS1000 Exhibit 11 – External Photos of the EUTPhoto # 2 WIRELESS WIRELESS PIR MOTION DETECTORS, Model No.: LS1000 & LS1002FCC ID: PDB-LS100-0-2 Note: Models LS1000 and LS1002 are exactly identical except for the slightly difference in size of the plastic sensor window Model LS1000 Exhibit 11 – External Photos of the EUTPhoto # 3 WIRELESS WIRELESS PIR MOTION DETECTORS, Model No.: LS1000 & LS1002FCC ID: PDB-LS100-0-2 Note: Models LS1000 and LS1002 are exactly identical except for the slightly difference in size of the plastic sensor window Model LS1002 Exhibit 11 – External Photos of the EUTPhoto # 4 WIRELESS WIRELESS PIR MOTION DETECTORS, Model No.: LS1000 & LS1002FCC ID: PDB-LS100-0-2 Note: Models LS1000 and LS1002 are exactly identical except for the slightly difference in size of the plastic sensor window Model LS1002

ID Label/Location Info

FCC ID LABEL FCC ID: PDB-LS100-0-2 Canada No.: xxxxx This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. Exhibit 16 - FCC Identifier Labeling Front Top Back PIR Motion Detector FCC ID Label

Internal Photos

Exhibit 12 – Internal Photos of the EUTPhoto # 1 WIRELESS WIRELESS PIR MOTION DETECTORS, Model No.: LS1000 & LS1002FCC ID: PDB-LS100-0-2 Note: The following pictures are the same for both Models LS1000 and LS1002 Exhibit 12 – Internal Photos of the EUTPhoto # 2 WIRELESS WIRELESS PIR MOTION DETECTORS, Model No.: LS1000 & LS1002FCC ID: PDB-LS100-0-2 Note: The following pictures are the same for both Models LS1000 and LS1002 Exhibit 12 – Internal Photos of the EUTPhoto # 3 WIRELESS WIRELESS PIR MOTION DETECTORS, Model No.: LS1000 & LS1002FCC ID: PDB-LS100-0-2 Note: The following pictures are the same for both Models LS1000 and LS1002 Exhibit 12 – Internal Photos of the EUTPhoto # 4 WIRELESS WIRELESS PIR MOTION DETECTORS, Model No.: LS1000 & LS1002FCC ID: PDB-LS100-0-2 Note: The following pictures are the same for both Models LS1000 and LS1002

Test Report

Oct. 29, 2000 FEDERAL COMMUNICATIONS COMMISSION 7435 Oakland Mills Road Columbia, MD 21046 USA Subject:Certification Application under FCC Part 15, Subpart C, Para. 15.231, Momentarily Operation in 433.70 MHz. Applicant:LEEDS ELECTRONIC ENGINEERING LTD. Product:WIRELESS WIRELESS PIR MOTION DETECTORS Model No.:LS1000 & LS1002 FCC ID:PDB-LS100-0-2 Dear Sir/Madam, As appointed agent for LEEDS ELECTRONIC ENGINEERING LTD., we would like to submit the application to the Federal Communications Commission for certification of the above product. Please review all necessary files uploaded to FCC OET site for detailed information. Models LS1000 and LS1002 are exactly identical in circuit design and packaging. The only difference is plastic sensor windows. Therefore, only a sample of Model LS1000 is selected for testing and representing for both models. Since the rf exposure safety distance is approximately 0.002 cm where the power density reach 0.29 mW/cm 2 and the antenna is enclosed within the case, the RF exposure risk is in-considerable. Therefore, the applicant wishes to apply for the exemption of meeting both the SAR test requirements per FCC OET Bulletin 65 and FCC RF Exposure Distance per 2.1093 If you have any queries, please do not hesitate to contact us. Yours truly, Tri Minh Luu, P. Eng., V.P., Engineering Encl 2 3000 Bristol Circle Oakville, Ontario, Canada L6H 6G4 Telephone (905) 829-1570 Facsimile (905) 829-8050 UltraTech Group of Labs Oct. 29, 2000 LEEDS ELECTRONIC ENGINEERING LTD. Flat B, 21/F, Yally Ind. Bldg., 6 Yip Fat St. Wong Chuk Hang, Hong Kong Attn.:Mr. Lui, Yun Tak Michael Subject:Certification Application under FCC Part 15, Subpart C, Para. 15.231, Momentarily Operation in 433.70 MHz. Product:WIRELESS WIRELESS PIR MOTION DETECTORS Model No.:LS1000 & LS1002 FCC ID:PDB-LS100-0-2 Dear Mr. Lui, The product sample, as provided by you, has been tested and found to comply with FCC PART 15, Subpart C, FCC Part 15, Subpart C, Para. 15.231, Momentarily Operation in 433.70 MHz. Since the rf exposure safety distance is approximately 0.002 cm where the power density reach 0.29 mW/cm 2 and the antenna is enclosed within the case, the RF exposure risk is in-considerable. Therefore, the applicant wishes to apply for the exemption of meeting both the SAR test requirements per FCC OET Bulletin 65 and FCC RF Exposure Distance per 2.1093. Enclosed you will find copies of the engineering report. If you have any queries, please do not hesitate to contact us. Yours truly, Tri Minh Luu, P. Eng., V.P., Engineering Encl 2 3000 Bristol Circle Oakville, Ontario, Canada L6H 6G4 Telephone (905) 829-1570 Facsimile (905) 829-8050 UltraTech Group of Labs WIRELESS WIRELESS PIR MOTION DETECTORS Model No.: LS1000 & LS1002 FCC ID: PDB-LS100-0-2 Applicant: LEEDS ELECTRONIC ENGINEERING LTD. Flat B, 21/F, Yally Ind. Bldg., 6 Yip Fat St. Wong Chuk Hang, Hong Kong In Accordance With FEDERAL COMMUNICATIONS COMMISSION (FCC) PART 15, SUBPART C, SEC. 15.231 Momentarily Operated Transmitters in 433.70 MHz UltraTech's File No.: KCE-011B-FCCTX This Test report is Issued under the Authority of Tri M. Luu, Professional Engineer, Vice President of Engineering UltraTech Group of Labs Date: Oct. 29, 2000 Report Prepared by: Tri M. Luu . Tested by: Hung Trinh Issued Date: Oct. 29, 2000Test Dates: Oct. 29, 2000 The results in this Test Report apply only to the sample(s) tested, and the sample tested is randomly selected. UltraTech 3000 Bristol Circle, Oakville, Ontario, Canada, L6H 6G4 Telephone (905) 829-1570 Facsimile (905) 829-8050 Website: www.ultratech-labs.com Email: [email protected] FCC PART 15, SUBPART C, Sec. 15.231, MOMENTARILY OPERATED TRANSMITTERSPage 2 WIRELESS WIRELESS PIR MOTION DETECTORS, Model No.: LS1000 & LS1002FCC ID: PDB-LS100-0-2 ULTRATECH GROUP OF LABSFile #: KCE-011B-FCCTX 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4Oct. 29, 2000 Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: [email protected], Website: http://www.ultratech-labs.com • Assessed by ITI (UK) Competent Body, NVLAP (USA) Accreditation Body & ACA/AUSTEL (Australia), VCCI (Japan) • Accredited by Industry Canada (Canada) under ACC-LAB (Europe/Canada MRA and APEC/Canada MRA) • Recognized/Listed by FCC (USA ) • All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST) TABLE OF CONTENTS EXHIBIT 1:SUBMITTAL CHECK LIST..................................................................................................................................................4 EXHIBIT 2:INTRODUCTION....................................................................................................................................................................5 2.1.SCOPE................................................................................................................................................................................................5 2.2.RELATED SUBMITAL(S)/GRANT(S).................................................................................................................................................5 2.3.NORMATIVE REFERENCES..........................................................................................................................................................5 EXHIBIT 3:PERFORMANCE ASSESSMENT........................................................................................................................................6 3.1.CLIENT INFORMATION.................................................................................................................................................................6 3.2.EQUIPMENT UNDER TEST (EUT) INFORMATION....................................................................................................................6 3.3.EUT’S TECHNICAL SPECIFICATIONS...............................................................................................................…

Text truncated - open the document above for the full version.

Test Report

Exhibit 9 - Plots of MeasurementsPlot # 1 WIRELESS WIRELESS PIR MOTION DETECTORS, Model No.: LS1000 & LS1002FCC ID: PDB-LS100-0-2 Exhibit 9 - Plots of MeasurementsPlot # 2 WIRELESS WIRELESS PIR MOTION DETECTORS, Model No.: LS1000 & LS1002FCC ID: PDB-LS100-0-2

Test Setup Photos

Exhibit 10 – Photograph of Test SetupPhoto # 1 WIRELESS WIRELESS PIR MOTION DETECTORS, Model No.: LS1000 & LS1002FCC ID: PDB-LS100-0-2 Exhibit 10 – Photograph of Test SetupPhoto # 2 WIRELESS WIRELESS PIR MOTION DETECTORS, Model No.: LS1000 & LS1002FCC ID: PDB-LS100-0-2 Exhibit 10 – Photograph of Test SetupPhoto # 3 WIRELESS WIRELESS PIR MOTION DETECTORS, Model No.: LS1000 & LS1002FCC ID: PDB-LS100-0-2

Contact Information

Applicant

Michael Y Lui(Manager)
[email protected](852) 2550-5284Fax: (852) 2873 1255

Technical Contact

Ultratech Engineering Labs Inc.Tri M Luu
[email protected]1-877-765-4173

3000 Bristol Circle · Oakville, Ontario · Canada

Non-Technical Contact

Ultratech Engineering Labs Inc.Tri M Luu
[email protected]1-877-765-4173

Test Firm

UltraTech Engineering Labs Inc.Tri Luu
[email protected]877-747-6381Fax: 905-829-8050

Technical Specifications

#Rule PartsFrequency RangePower Output
115C433.7 MHz - 433.7 MHz-
Confidentiality
Long Term

Other Applications from Leeds Electronic Engineering LTD

DSC - Part 15 Security/Remote Control Transmitter - FCC ID PDB-LS1001 - Leeds Electronic Engineering LTD
PDB-LS1001

DSC - Part 15 Security/Remote Control Transmitter

Dec 27, 2000

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter