Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jun 10, 2001
Application Purpose
Original Equipment
Date of Application
May 02, 2001
Equipment Note
Remote Control Lamps
Frequency Range
290.14000000 - 290.14000000
Company
Action Products Limited
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗
↗

Schematics

↗

Test Report

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

External Photos

MAX LIGHT Report Number: MLT0105P15010 FCC ID: PI9062900 Technology Lab MAX LIGHT Report Number: MLT0105P15010 FCC ID: PI9062900 Technology Lab MAX LIGHT Report Number: MLT0105P15010 FCC ID: PI9062900 Technology Lab MAX LIGHT Report Number: MLT0105P15010 FCC ID: PI9062900 Technology Lab

ID Label/Location Info

MAX LIGHT Report Number: MLT0105P15010 FCC ID: PI9062900 Technology Lab Label Format: Label Position: This device complies with Part15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference,and (2) This device must accept any interference received ,including. Interference that may cause undesired operation. Model: 06290 FCC ID: PI9062900 MADE IN China Equipment Lable 4.0CMX2.5CM Rear View

Internal Photos

MAX LIGHT Report Number: MLT0105P15010 FCC ID: PI9062900 Technology Lab

Internal Photos

MAX LIGHT Report Number: MLT0105P15010 FCC ID: PI9062900 Technology Lab MAX LIGHT Report Number: MLT0105P15010 FCC ID: PI9062900 Technology Lab

Schematics

1 2 3 4 5 6 7 8 9 18 17 16 15 14 13 12 11 10 R5 4.7K R7 4.7K R3 R6 47K S2 SW-PH S1 SW-PH BATTER 12V D1 LED R4 33K R1 1K Q1 R8 4.7K L1 4.7uH C2 472p C3 3p Q2 9318 CX 3P C6 3P C5 1P R4 2-4P C1 C1 30P BEAD 2012K221

Test Report

Product : Remote Control Lamps Manufacture : Action Products Limited . FCC ID : PI9062900 Model : 06290 Report No. : MLT0105P15010 Test Date : May 03,2001 Test By Max Light Technology Co.,Ltd. Room 5, 8F, No.125, Section 3 Roosevelt Road, Taipei, Taiwan., R.O.C. Tel: 886-2-363-2447 Fax: 886-2-363-2597 T T h h e e t t e e s s t t r r e e p p o o r r t t c c o o n n s s i i s s t t s s o o f f 1 1 9 9 p p a a g g e e s s i i n n t t o o t t a a l l . . I I t t m m a a y y b b e e d d u u p p l l i i c c a a t t e e d d c c o o m m p p l l e e t t e e l l y y f f o o r r l l e e g g a a l l u u s s e e w w i i t t h h t t h h e e a a l l l l o o w w a a n n c c e e o o f f t t h h e e a a p p p p l l i i c c a a n n t t . . I I t t s s h h a a l l l l n n o o t t b b e e r r e e p p r r o o d d u u c c e e d d e e x x c c e e p p t t i i n n f f u u l l l l , , w w i i t t h h o o u u t t t t h h e e w w r r i i t t t t e e n n a a p p p p r r o o v v a a l l o o f f o o u u r r l l a a b b o o r r a a t t o o r r y y . . MAX LIGHT MEASUREMENT REPORT Page: 2/19 Report Number: MLT0105P15010 FCC ID: PI9062900 Technology Lab Table of Contents : I. General 4. II. Conducted Emissions Requirements 6. III. Radiated Emissions Requirements 7. IV.Transmitter Bandwidth Measurements 13. V. Transmitter Duty Cycle Measurements 15. Appendix I (EUT Test Setup) 17. MAX LIGHT MEASUREMENT REPORT Page: 3/19 Report Number: MLT0105P15010 FCC ID: PI9062900 Technology Lab CERTIFICATION We here by verify that : The test data, data evaluation, test procedures and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.4-1992. All test were conducted by MLT (Max Light Technology Co.,Ltd) Room 5, 8F, No.125, Section 3 Roosevelt Road, Taipei, Taiwan, R.O.C Also, we attest to the accuracy of each. We further submit that the energy emitted by the sample EUT tested as described in the report is in compliance with radiated emission limit of FCC Rules Part 15 Subpart C Section 15.231. EUT: Remote Control Lamps Applicant: Action Products Limited. Flat J, 11Fl, Yue Cheung Centre, 1-3 Wong Chuk Yeung Street, Fo Tan, Shatin, N.T., Hong Kong Manufacturer: Well Brain Industrial Limited. Unit 21, 11Fl., Yale Industrial Centre, No. 61-63 Au Pui Wan Street, Fo Tan, Shatin, N.T., Hong Kong Model No: 06290 FCC ID: PI9062900 Prepared by : Approved by : Country Huang Roger Chen MAX LIGHT MEASUREMENT REPORT Page: 4/19 Report Number: MLT0105P15010 FCC ID: PI9062900 Technology Lab I. GENERAL 1.1 Introduction The following measurement report is submitted on behalf of Action Products Limited . In support of an Intentional Periodic Radiator certification in accordance with Part 2 Subpart J and Part 15 Subpart A And C of the Commission’s and Regulations. 1.2 Description of EUT EUT: Remote Control Lamps Applicant: Action Products Limited. Flat J, 11Fl, Yue Cheung Centre, 1-3 Wong Chuk Yeung Street, Fo Tan, Shatin, N.T., Hong Kong Manufacturer: Well Brain Industrial Limited. Unit 21, 11Fl., Yale Industrial Centre, No. 61-63 Au Pui Wan Street, Fo Tan, Shatin, N.T., Hong Kong Model No: 06290 FCC ID : PI9062900 Power Type: Powered by DC 12V Battery The EUT(06290) is Remote Control of On/Off Controller. The operation frequency is 290.14Mhz. Press the button on remote transmitter, can set the ON/OFF(LIGHT) button. MAX LIGHT MEASUREMENT REPORT Page: 5/19 Report Number: MLT0105P15010 FCC ID: PI9062900 Technology Lab 1.3 Description of Support Equipment The EUT itself forms a system. No support equipment is required for its normal operation. 1.4 Configuration of System Under Test 1.5 Test Procedure All measurements contained in this report were performed according to the techniques described in Measurement procedure ANSI C63.4-1992 "Measurement of Intentional Radiators." EUT MAX LIGHT MEASUREMENT REPORT Page: 6/19 Report Number: MLT0105P15010 FCC ID: PI9062900 Technology Lab 1.6 General Test Condition The conditions under which the EUT operates were varied to determine their effect on the equipment's emission characteristics. The final configuration of the test system and the mode of operation used during these tests was chosen as that which produced the highest emission levels. However, only those conditions which the EUT was considered likely to encounter in normal use were investigated. MAX LIGHT MEASUREMENT REPORT Page: 7/19 Report Number: MLT0105P15010 FCC ID: PI9062900 Technology Lab II. Conducted Emissions Requirements The EUT operates solely by the battery. According to the rule of Section 15.207(c), the EUT exempt to the power line conducted test. MAX LIGHT MEASUREMENT REPORT Page: 8/19 Report Number: MLT0105P15010 FCC ID: PI9062900 Technology Lab III. Radiated Emissions Requirements 3.1 General Configuration: Prior to open-field testing, the EUT was placed in a shielded enclosure and scanned at a close distance to determine its emission characteristics. The physical arrangement of the EUT was varied (within the scope of arrangements likely to be encountered in actual use) to determine the effect on the unit's emanations in amplitude, directivity, and frequency. The exact system configuration which produced the highest emissions was noted so it could be reproduced later during the open-field tests. This was done to ensure that the final measurements would demonstrate the worst-case interference potential of the EUT. 3.2 General Configuration: Final radiation measurements were made on a three-meter, open- field test site. The EUT system was placed on a nonconductive turntable which is 0.8 meters height, top surface 1.0 x 1.5 meter. The spectrum was examined from 250 MHz to 4 GHz in order to cover the whole spectrum below10th harmonic which could generate from the EUT. During the test,EUT was set to transmit continuously and the switch was positioned to yield the maximum duty cycle which had measured before radiated emissions test. A nonconductive material surrounded the EUT to supporting the EU…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Mr.Ted Lam(Manager)
[email protected]852-2608-1778Fax: 852-2608-1802

Technical Contact

Max Light Technology Co.,LtdCountry Huang
[email protected]886-2-26633486

P.O.Box 5-86,Shen Keng · Taipei Hsien · Taiwan

Non-Technical Contact

Max Light Technology Co.,LtdCountry Huang
[email protected]886-2-26633486

Test Firm

Max Light Technology Co., Ltd.Jesse Tien
[email protected]8862-266633486Fax: 866-2-26633582

Technical Specifications

#Rule PartsFrequency RangePower Output
115C290.14 MHz - 290.14 MHz-