Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
INSTALLATION final public (B) 2010-05-26 M90401-1e-ID-B.doc OBID i-scan ® ID ISC.ANT310310-A HF Antenna OBID i-scan ® Installation ID ISC.ANT310/310-A FEIG ELECTRONIC GmbH Page 2 of 22 M90401-1e-ID-B.doc Note © Copyright 2009-2010 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg Tel.: +49 6471 3109-0 http://www.feig.de With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design. Composition of the information in this document has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments and does not give any guaranty for the functionality of the complete system which incorporates the subject of this document. FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to a human. To avoid damage, injury, or death, the user or application designer must take reasonably prudent steps to protect against system failures. FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this docu- ment and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others. OBID ® and OBID i-scan ® are registered trademarks of FEIG ELECTRONIC GmbH. All cited brand names, product names, or trademarks belong to their respective holders. OBID i-scan ® Installation ID ISC.ANT310310-A FEIG ELECTRONIC GmbH Page 3 of 22 M90401-1e-ID-B.doc E N G L I S H Contents 1 Safety Instructions / Warning - Read before start-up ! 4 2 Features of the antenna ID ISC.ANT310/310 5 3 Installation and Wiring 6 4 Start-up 7 4.1 Project Notes ................................................................................................................. 7 4.2 Configuring the Reader in accordance with national RF regulations ...................... 9 4.3 The influence of the transmitting power on the reading range ............................... 10 4.4 The influence of metal on the reading range ............................................................ 11 4.5 The influence of the noise level on the antenna’s working range .......................... 12 4.6 How to measure the voltage standing wave ratio (VSWR) ...................................... 13 4.7 Antenna tuning ............................................................................................................ 14 5 Course of the antenna’s magnetic lines of electric flux 18 6 Technical data 19 6.1 Approval ....................................................................................................................... 20 6.1.1 Europe (CE) .............................................................................................................. 20 6.1.2 USA (FCC) and Canada (IC) .................................................................................... 21 7 System delivery contents 22 OBID i-scan ® Installation ID ISC.ANT310/310-A FEIG ELECTRONIC GmbH Page 4 of 22 M90401-1e-ID-B.doc 1 Safety Instructions / Warning - Read before start-up ! • The device may only be used for the intended purpose designed by for the manufacturer. • The operation manual should be conveniently kept available at all times for each user. • Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorized measures shall exclude any liability by the manufacturer. • The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors, or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device. • Repairs may only be executed by the manufacturer. • Installation, operation, and maintenance procedures should only be carried out by qualified personnel. • Use of the device and its installation must be in accordance with national legal requirements and local electrical codes . • When working on devices the valid safety regulations must be observed. • Please observe that some parts of the device may heat severely. • Special advice for carriers of cardiac pacemakers: Although this device doesn't exceed the valid limits for electromagnetic fields you should keep a minimum distance of 25 cm between the device and your cardiac pacemaker and not stay in an immediate proximity of the device respective the antenna for some time. • Do not use harsh chemicals, cleaning solvents or strong detergents to clean the antenna. Wipe it with a soft cloth slightly dampened in a mild soap-and-water solution. CAUTION! When working on an opened device, the Antenna-Tuner and the Antenna conductor carry voltages up to 1000V. OBID i-scan ® Installation ID ISC.ANT310310-A FEIG ELECTRONIC GmbH Page 5 of 22 M90401-1e-ID-B.do…
Text truncated - open the document above for the full version.
CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 38 of 69 9 Ph otog ra ph s of th e EUT Photo documentation: external photos Photo 1: ID ISC.ANT1690/600 (ant. 1) Gate 1 (multiplexer only) CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 39 of 69 Photo 2: ID ISC.ANT1690/600 (ant. 1) Gate 1 (multiplexer only) CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 40 of 69 Photo 3: ID ISC.ANT1690/600 (ant. 1) Gate 2 (multiplexer & reader) CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 41 of 69 Photo 4: ID ISC.ANT1690/600 (ant. 1) Gate 2 (multiplexer & reader) CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 42 of 69 Photo 1: ID ISC.ANT1700/740 (ant. 2) Gate 1 (multiplexer only) CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 43 of 69 Photo 2: ID ISC.ANT1700/740 (ant. 2) Gate 1 (multiplexer only) CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 44 of 69 Photo 3: ID ISC.ANT1700/740 (ant. 2) Gate 2 (multiplexer & reader) CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 45 of 69 Photo 4: ID ISC.ANT1700/740 (ant. 2) Gate 2 (multiplexer & reader) CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 46 of 69 Photo 5: ID ISC.ANT310/310 (ant. 3) Photo 6: ID ISC.ANT310/310 (ant. 3)
CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 48 of 69 Photo documentation: internal photos Photo 1: ID ISC.ANT1690/600 (ant. 1) Gate 1 (multiplexer only) Photo 2: ID ISC.ANT1690/600 (ant. 1) Gate 1 (multiplexer only) CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 49 of 69 Photo 3: ID ISC.ANT1690/600 (ant. 1) Gate 1 (multiplexer only) Photo 4: ID ISC.ANT1690/600 (ant. 1) Gate 2 (multiplexer & reader) CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 50 of 69 Photo 5: ID ISC.ANT1690/600 (ant. 1) Gate 2 (multiplexer & reader) Photo 6: ID ISC.ANT1690/600 (ant. 1) Gate 2 (multiplexer & reader) CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 51 of 69 Photo 7: ID ISC.ANT1690/600 (ant. 1) Gate 2 (multiplexer & reader) Photo 8: ID ISC.ANT1690/600 (ant. 1) Gate 2 (multiplexer & reader) CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 52 of 69 Photo 9: ID ISC.ANT1690/600 (ant. 1) Gate 2 (multiplexer & reader) CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 53 of 69 Photo 10: ID ISC.ANT1700/740 (ant. 2) Gate 1 (multiplexer only) CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 54 of 69 Photo 11: ID ISC.ANT1700/740 (ant. 2) Gate 1 (multiplexer only) Photo 12: ID ISC.ANT1700/740 (ant. 2) Gate 1 (multiplexer only) CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 55 of 69 Photo 13: ID ISC.ANT1700/740 (ant. 2) Gate 2 (multiplexer & reader) CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 56 of 69 Photo 14: ID ISC.ANT1700/740 (ant. 2) Gate 2 (multiplexer & reader) Photo 15: ID ISC.ANT1700/740 (ant. 2) Gate 2 (multiplexer & reader) CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 57 of 69 Photo 16: ID ISC.ANT1700/740 (ant. 2) Gate 2 (multiplexer & reader) Photo 17: ID ISC.ANT1700/740 (ant. 2) Gate 2 (multiplexer & reader) CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 58 of 69 Photo 18: ID ISC.ANT1700/740 (ant. 2) Gate 2 (multiplexer & reader) Photo 19: ID ISC.ANT310/310 (ant. 3) CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 59 of 69 Photo 20: ID ISC.LRM 2000 Photo 21: ID ISC.LRM 2000 CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 60 of 69 Photo 22: ID ISC.LRM 2000 Photo 23: ID ISC.LRM 2000 CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 61 of 69 Photo 24: ID ISC.LRM 2000 Photo 25: ID ISC.LRM 2000 CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 62 of 69 Photo 26: ID ISC.LRM 2000 Photo 27: ID ISC.LRM 2000 CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 63 of 69 Photo 28: ID ISC.LRM 2000 Photo 29: ID ISC.LRM 2000 CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 64 of 69 Photo 30: ID ISC.LRM 2000 Photo 31: ID ISC.LRM 2000 CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 65 of 69 Photo 32: ID ISC.LRM 2000 Photo 33: ID ISC.LRM 2000 CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 66 of 69 Photo 34: ID ISC.LRM 2000 Photo 35: ID ISC.LRM 2000 CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 67 of 69 Photo 36: ID ISC.LRM 2000 Photo 37: ID ISC.LRM 2000 CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 68 of 69 Photo 38: ID ISC.LRM 2000 Photo 39: ID ISC.LRM 2000 CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 69 of 69 Photo 40: ID ISC.LRM 2000
CETECOM ICT Services GmbH Untertürkheimer Straße 6-10 . D-66117 Saarbrücken Phone: +49 (0) 681-598-0 Fax: -9075 RSC-Laboratory 2010-05-07 Page 1 of 69 Accredited testing-laboratory DAR registration number: DGA-PL-176/94-D1 Federal Motor Transport Authority (KBA) DAR registration number: KBA-P 00070-97 Recognized by the Federal Communications Commission Anechoic chamber registration no.: 90462 (FCC) Anechoic chamber registration no.: 3462C-1 (IC) Certification ID: DE 0001 Accreditation ID: DE 0002 Accredited Bluetooth ® Test Facility (BQTF) The Bluetooth word mark and logos are owned by the Bluetooth SIG, Inc. and any use of such marks by Cetecom ICT is under license Test report no. : 1-2124-01-03/10 Type identification : ID ISC.LRM 2000 (Reader) + ID ISC.ANT1690/600 (antenna 1) ID ISC.ANT1700/740 (antenna 2) ID ISC.ANT310/310 (antenna 3) Applicant : FEIG ELECTRONIC GmbH FCC ID : PJMLRM2000-2 IC Certification No : 6633A-LRM2000-2 Test standards : 47 CFR Part 15 RSS - 210 Issue 7 CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 2 of 69 Table of contents 1 G e n e r a l i n f o r m a t i o n . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . 3 1.1 Notes ...................................................................................................................................................................3 1.2 Testing laboratory ...............................................................................................................................................4 1.3 Details of applicant .............................................................................................................................................4 1.4 Application details ..............................................................................................................................................4 2 T e s t s t a n d a r d / s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . 5 3 T e c h n i c a l t e s t s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . 6 3.1 Details of manufacturer.......................................................................................................................................6 3.2 Test Item .............................................................................................................................................................6 3.3 Test Item (Additional EUT information For IC Canada (appendix 2) ................................................................7 3.4 Extreme conditions testing values.......................................................................................................................8 3.5 Reference documents ..........................................................................................................................................8 3.6 Additional comments ..........................................................................................................................................8 4 S t a t e m e n t o f C o m p l i a n c e . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . 9 4.1 Summary of Measurement Results .....................................................................................................................9 4.2 CFR 47 Part 15.225.............................................................................................................................................9 5 M e a s u r e m e n t s a n d R e s u l t s . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . 1 0 6 F C C P a r t 1 5 . 2 2 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . 1 1 6.1 Field strength of the fundamental......................................................................................................................11 6.2 Field strength of the harmonics and the spurious ..............................................................................................14 6.3 Frequency tolerance ..........................................................................................................................................29 6.4 Conducted Limits ..............................................................................................................................................30 7 T e s t e q u i p m e n t a n d a n c i l l a r i e s u s e d f o r t e s t s . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . 3 2 8 P h o t o g r a p h s o f t h e T e s t S e t - u p . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . 3 4 9 P h o t o g r a p h s o f t h e E U T . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . 3 8 CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 3 of 69 1 Gen era l info rma tion 1 . 1 N o t e s The test results of this test report relate exclusively to the test item specified in 3.1.1. The CETECOM ICT Services GmbH does not assume responsibilit…
Text truncated - open the document above for the full version.
CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 34 of 69 8 Ph otog ra ph s of th e Test S et-up Photo documentation: Photo 1: ID ISC.ANT1690/600 (ant. 1) Photo 2: ID ISC.ANT1690/600 (ant. 1) CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 35 of 69 Photo 3: ID ISC.ANT1700/740 (ant. 2) Photo 4: ID ISC.ANT1700/740 (ant. 2) CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 36 of 69 Photo 5: ID ISC.ANT310/310 (ant. 3) Photo 6: ID ISC.ANT310/310 (ant. 3) CETECOM ICT Services GmbH Test report no.: 1-2124-01-03/10 2010-05-07 Page 37 of 69 Photo 7: AC conducted
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 13.56 MHz - 13.56 MHz | - |

RFID Reader
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
RFID Reader
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterWireless Safety System for industrial doors - Mobile Unit
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
RFID Reader
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
RFID Reader
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter