Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Annex no. 5 Functional Description / User Manual MONTAGE INSTALLATION Preliminary public (B) 2011-04-13 M01111-0de-ID-B.DOC ID ISC.LRM2500-B (deutsch / english) OBID i-scan ® Montage ID ISC.LRM2500-B FEIG ELECTRONIC GmbH Seite 2 von 63 M01111-0de-ID-B.DOC D E U T S C H deutsche Version ab Seite 3 english version from page 34 E N G L I S H OBID i-scan ® Montage ID ISC.LRM2500-B FEIG ELECTRONIC GmbH Seite 3 von 63 M01111-0de-ID-B.DOC D E U T S C H Hinweis Copyright 2011 by FEIG ELECTRONIC GmbH Lange Straße 4 D-35781 Weilburg-Waldhausen Tel.: +49 6471 3109-0 http://www.feig.de Alle früheren Ausgaben verlieren mit dieser Ausgabe ihre Gültigkeit. Die Angaben in diesem Dokument können ohne vorherige Ankündigung geändert werden. Weitergabe sowie Vervielfältigung dieses Dokuments, Verwertung und Mitteilung ihres Inhalts sind nicht gestattet, soweit nicht ausdrücklich zugestanden. Zuwiderhandlung verpflichtet zu Schadenersatz. Alle Rechte für den Fall der Patenterteilung oder Gebrauchsmuster-Eintragung vorbehalten. Die Zusammenstellung der Informationen in diesem Dokument erfolgt nach bestem Wissen und Gewissen. FEIG ELECTRONIC GmbH übernimmt keine Gewährleistung für die Richtigkeit und Vollständigkeit der An- gaben in diesem Dokument. Insbesondere kann FEIG ELECTRONIC GmbH nicht für Folgeschäden auf Grund fehlerhafter oder unvollständiger Angaben haftbar gemacht werden. Da sich Fehler, trotz aller Bemü- hungen nie vollständig vermeiden lassen, sind wir für Hinweise jederzeit dankbar. Die in diesem Dokument gemachten Installationsempfehlungen gehen von günstigsten Rahmenbedingun- gen aus. FEIG ELECTRONIC GmbH übernimmt weder Gewähr für die einwandfreie Funktion in system- fremden Umgebungen, noch für die Funktion eines Gesamtsystems, welches die in diesem Dokument be- schriebenen Geräte enthält. FEIG ELECTRONIC weist ausdrücklich darauf hin, dass die in diesem Dokument beschriebenen Geräte nicht für den Einsatz mit oder in medizinischen Geräten oder für Geräte für lebenserhaltende Maßnahmen konzipiert sind, bei denen ein Fehler eine Gefahr für menschliches Leben oder für die gesundheitliche Un- versehrtheit zur Folge haben kann. Der Applikationsdesigner ist dafür verantwortlich geeignete Maßnahmen zu ergreifen um Gefahren, Schäden oder Verletzungen zu vermeiden. FEIG ELECTRONIC GmbH übernimmt keine Gewährleistung dafür, dass die in diesem Dokument enthal- tenden Informationen frei von fremden Schutzrechten sind. FEIG ELECTRONIC GmbH erteilt mit diesem Dokument keine Lizenzen auf eigene oder fremde Patente oder andere Schutzrechte. OBID ® und OBID i-scan ® ist ein eingetragenes Warenzeichen der FEIG ELECTRONIC GmbH my-d ® ist ein eingetragenes Warenzeichen der Infineon Technologies AG I-CODE ® und mifare ® ist ein eingetragenes Warenzeichen der Philips Electronics N.V. Tag-it ist ein Warenzeichen der Texas Instruments Incorporated OBID i-scan ® Montage ID ISC.LRM2500-B FEIG ELECTRONIC GmbH Seite 4 von 63 M01111-0de-ID-B.DOC D E U T S C H Inhalt Sicherheits- und Warnhinweise - vor Inbetriebnahme unbedingt lesen 6 1 Leistungsmerkmale der Readerfamilie ID ISC.LRM2500 7 1.1 Leistungsmerkmale .................................................................................................... 7 1.2 Verfügbare Readervarianten ...................................................................................... 7 2 Montage und Anschluss 8 2.1 Montage ....................................................................................................................... 8 2.2 Anschlussklemmen .................................................................................................. 10 2.3 Antennenanschluss .................................................................................................. 11 2.4 Versorgungsspannung ............................................................................................. 12 2.5 Sicherung F1 ............................................................................................................. 13 2.6 Optokoppler Eingänge (X2 / IN1, IN2, IN3) .............................................................. 14 2.7 Optokoppler Ausgänge (X2 / OUT1, OUT2) ............................................................. 17 2.8 Relais (X2 / REL1, REL2, REL3) ............................................................................... 18 2.9 Ausgang 24V (X2 / 24V, GND) ............................................................................ 20 2.10 Anschluss externer Diagnose-LEDs X8 .................................................................. 21 2.11 Schnittstellen ............................................................................................................ 22 2.11.1 RS232-Schnittstelle X3 .......................................................................................... 22 2.11.2 RS485-Schnittstelle X3 .......................................................................................... 23 2.12 USB – Schnittstelle X4 (Host Kommunikation) ....................................................... 25 2.12.1 Ethernet-Schnittstelle an X1 (10/100 Base-T) ........................................................ 26 3 Bedien- und Anzeigeelemente 27 3.1 LEDs .......................................................................................................................... 27 3.2 Taster T1.................................................................................................................... 28 4 Funkzulassungen 29 OBID i-scan ® Montage ID ISC.LRM2500-B FEIG ELECTRONIC GmbH Seite 5 von 63 M01111-0de-ID-B.DOC D E U T S C H 4.1 Europa (CE) ............................................................................................................... 29 4.2 USA (FCC) und Kanada (IC) ............................................................................…
Text truncated - open the document above for the full version.
m. dudde hochfrequenz-technik Rottland 5a, D-51429 Bergisch-Gladbach DIN EN ISO/IEC 17025 certified DAkkS accreditation number: D-PL-12053-01 Tel. : +49 22 07 - 96 89 - 0 Fax : +49 22 07 - 96 89 - 20 email: [email protected] www.dudde.com PHOENIX TEST-LAB GmbH Product Certification Königswinkel 10 D 32825 Blomberg Date: 2011-06-16 Brand/Trade name: OBID i-scan Model name: ID ISC.LR2500 FCC Certification Number: PJMLRM2500 IC Certification Number: 6633A-LRM2500 Subject: Compliance Statement in the User Manual Dear Sirs, On behalf of our customer FEIG ELECTRONIC GmbH, we would like to inform you that they assure that the following will be included in a prominent location of the user manual: This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions. (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Unauthorized modifications may void the authority granted under Federal communications Commission Rules permitting the operation of this device. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This Class A digital apparatus complies with Canadian ICES-003. m. dudde hochfrequenz-technik Rottland 5a, D-51429 Bergisch-Gladbach DIN EN ISO/IEC 17025 certified DAkkS accreditation number: D-PL-12053-01 Tel. : +49 22 07 - 96 89 - 0 Fax : +49 22 07 - 96 89 - 20 email: [email protected] www.dudde.com Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. Yours sincerely, m. dudde hochfrequenz-technik Andreas Morsbach Management Assistant
m. dudde hochfrequenz-technik Rottland 5a, D-51429 Bergisch-Gladbach DIN EN ISO/IEC 17025 zertifiziert Akkreditiertes Testhaus- Reg.-Nr.: DAT-P-225/96-02 Tel. : +49 22 07 - 96 89 - 0 Fax : +49 22 07 - 96 89 - 20 email: [email protected] www.dudde.com RE: Construction Equality Declaration To Whom It May Concern: Our customer, FEIG ELECTRONIC GmbH, Brand/Trade name: OBID i-scan Model name: ID ISC.LR2500 Herewith declare, that the ID ISC.LR2500-A of: Company name : FEIG ELECTRONIC GmbH Address : Lange Straße 4 35781 Weilburg Country : Germany Telephone : +49 (0) 6471 31 09 0 Fax : +49 (0) 6471 31 09 99 Email : [email protected] is mechanically and electrically similar to the ID ISC.LR2500-B of: Company name : FEIG ELECTRONIC GmbH Address : Lange Straße 4 35781 Weilburg Country : Germany Telephone : +49 (0) 6471 31 09 0 Fax : +49 (0) 6471 31 09 99 Email : [email protected] The differences between ID ISC.LR2500-A and ID ISC.LR2500-B are only the numbers of ports and the logic board. The radio module is absolutely identically! m. dudde hochfrequenz-technik Andreas Morsbach Management Assistant
m. dudde hochfrequenz-technik Rottland 5a, D-51429 Bergisch-Gladbach DIN EN ISO/IEC 17025 certified DAkkS accreditation number: D-PL-12053-01 Tel. : +49 22 07 - 96 89 - 0 Fax : +49 22 07 - 96 89 - 20 email: [email protected] www.dudde.com Attn: Reviewing Engineer RE: FCC Part 15C MODULAR TRANSMITTER APPROVAL To Whom It May Concern: Our customer, FEIG ELECTRONIC GmbH, hereby requests limited modular approval acc. to FCC Part 15 (Modular Approval) Brand/Trade name: OBID i-scan Model name: ID ISC.LR2500 FCC certification number: PJMLRM2500 Transmitters designed as modules for the installation in a host device may obtain equipment certification as a modular device provided that the applicable FCC part is met and the following conditions in this section are met. Items to be covered Answer from applicant 1. The modular transmitter must have its own RF shielding. YES, see external photographs "Annex No. 1" 2. The modular transmitter must have buffered modulation/data inputs (if such inputs are provided) to ensure that the module will comply with Part 15 requirements under conditions of excessive data rates or over-modulation. YES 3. The modular transmitter must have its own power supply regulation. YES 4. The modular transmitter must comply with the antenna requirements of Section 15.203 and 15.204(c). The antenna must either be permanently attached or employ a “unique” antenna coupler (at all connections between the module and the antenna, including the cable).. YES, the RF module will be integrated into host devices subject to professional installation 5. The modular transmitter must be tested in a stand-alone configuration, i.e., the module must not be inside another device during testing. This is intended to demonstrate that the module is capable of complying with Part 15 emission limits regardless of the device into which it is eventually installed. YES, see test setup photographs "Annex No. 6" m. dudde hochfrequenz-technik Rottland 5a, D-51429 Bergisch-Gladbach DIN EN ISO/IEC 17025 certified DAkkS accreditation number: D-PL-12053-01 Tel. : +49 22 07 - 96 89 - 0 Fax : +49 22 07 - 96 89 - 20 email: [email protected] www.dudde.com 6. The modular transmitter must be labeled with its own FCC ID number, and, if the FCC ID is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. This exterior label can use wording such as the following: “Contains Transmitter Module FCC ID: XYZMODEL1” or “Contains FCC ID: XYZMODEL1.” Any similar wording that expresses the same meaning may be used. The Grantee may either provide such a label, an example of which must be included in the application for equipment authorization, or, must provide adequate instructions along with the module which explain this requirement. In the latter case, a copy of these instructions must be included in the application for equipment authorization. YES, see label sample "Annex No. 4" and the labeling instructions can be found in the Installation Manual which is included with the device 7. The modular transmitter must comply with any specific rule or operating requirements applicable to the transmitter and the manufacturer must provide adequate instructions along with the module to explain any such requirements. A copy of these instructions must be included in the application for equipment authorization. For example, there are very strict operational and timing requirements that must be met before a transmitter is authorized for operation under Section 15.231. For instance, data transmission is prohibited, except for operation under Section 15.231(e), in which case there are separate field strength level and timing requirements. Compliance with these requirements must be assured. YES 8. The modular transmitter must comply with any applicable RF exposure requirements. For example, FCC Rules in Sections 2.1091, 2.1093 and specific Sections of Part 15, including 15.319(i), 15.407(f), 15.253(f) and 15.255(g), require that Unlicensed PCS, UNII and millimeter wave devices perform routine environmental evaluation for RF Exposure to demonstrate compliance. In addition, spread spectrum transmitters operating under Section 15.247 are required to address RF Exposure compliance in accordance with Section 15.247(b)(4). Modular transmitters approved under other Sections of Part 15, when necessary, may also need to address certain RF Exposure concerns, typically by providing specific installation and operating instructions for users, installers and other interested parties to ensure compliance. N/A, this RF module is subject to §15.225 and therefore exempted Note: If compliance with one or more of the numbered requirements, listed above, cannot be demonstrated, it may be possible to obtain a “Limited Modular Approval” (LMA). m. dudde hochfrequenz-technik Andreas Morsbach Management Assistant
State: 2010-03-01Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Annex no. 12 Antenna Descriptions INSTALLATION final public (B) 2011 -04-13 M90401-2e-ID-B.doc OBID i-scan ® ID ISC.ANT310310-A HF Antenna OBID i-scan ® InstallationID ISC.ANT310/310-A FEIG ELECTRONIC GmbHPage 2 of 22M90401-2e-ID-B.doc Note Copyright 2009-2011 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg Tel.: +49 6471 3109-0 http://www.feig.de With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design. Composition of the information in this document has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments and does not give any guaranty for the functionality of the complete system which incorporates the subject of this document. FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to a human. To avoid damage, injury, or death, the user or application designer must take reasonably prudent steps to protect against system failures. FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this docu- ment and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others. OBID ® and OBID i-scan ® are registered trademarks of FEIG ELECTRONIC GmbH. All cited brand names, product names, or trademarks belong to their respective holders. OBID i-scan ® InstallationID ISC.ANT310310-A FEIG ELECTRONIC GmbHPage 3 of 22M90401-2e-ID-B.doc E N G L I S H Contents 1 Safety Instructions / Warning - Read before start-up !4 2 Features of the antenna ID ISC.ANT310/310 5 3 Installation and Wiring 6 4 Start-up7 4.1 Project Notes .............................................................................................................. 7 4.2 Configuring the Reader in accordance with national RF regulations ..................... 9 4.3 The influence of the transmitting power on the reading range............................. 10 4.4 The influence of metal on the reading range .......................................................... 11 4.5 The influence of the noise level on the antenna’s working range......................... 12 4.6 How to measure the voltage standing wave ratio (VSWR)..................................... 13 4.7 Antenna tuning ......................................................................................................... 14 5 Course of the antenna’s magnetic lines of electric flux18 6 Technical data19 6.1 Approval .................................................................................................................... 20 6.1.1 Europe (CE) ........................................................................................................... 20 6.1.2 USA (FCC) and Canada (IC) .................................................................................. 21 7 System delivery contents22 OBID i-scan ® InstallationID ISC.ANT310/310-A FEIG ELECTRONIC GmbHPage 4 of 22M90401-2e-ID-B.doc 1 Safety Instructions / Warning - Read before start-up ! The device may only be used for the intended purpose designed by for the manufacturer. The operation manual should be conveniently kept available at all times for each user. Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorized measures shall exclude any liability by the manufacturer. The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors, or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device. Repairs may only be executed by the manufacturer. Installation, operation, and maintenance procedures should only be carried out by qualified personnel. Use of the device and its installation must be in accordance with national legal requirements and local electrical codes . When working on devices the valid safety regulations must be observed. Please observe that some parts of the device may heat severely. Special advice for carriers of cardiac pacemakers: Although this device doesn't exceed the valid limits for electromagnetic fields you should keep a minimum distance of 25 cm between the device and your cardiac pacemaker and not stay in an immediate proximity of the device respective the antenna for some time. Do not use harsh chemicals, cleaning solvents or strong detergents to clean the antenna. Wipe it with a soft cloth slightly dampened in a mild soap-and-water solution. CAUTION! When working on an opened device, the Antenna-Tuner and t…
Text truncated - open the document above for the full version.
State: 2010-03-01Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Annex no. 12 Antenna Descriptions INSTALLATION final public (B) 2011 -04-12 M00210-3e-ID-B.doc ID ISC.ANT1700/740-SLA /-SLB Clear Gate English OBID i-scan ® InstallationID ISC.ANT1700/740-SLA/-SLB FEIG ELECTRONIC GmbHPage 2 of 70M00210-3e-ID-B.doc Note Copyright 2010-2011 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg Tel.: +49 6471 3109-0 http://www.feig.de With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design. Composition of the information in this document has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments and does not give any guaranty for the functionality of the complete system which incorporates the subject of this document. FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to a human. To avoid damage, injury, or death, the user or application designer must take reasonably prudent steps to protect against system failures. FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this docu- ment and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others. OBID ® and OBID i-scan ® are registered trademarks of FEIG ELECTRONIC GmbH. I-CODE ® is a registered trademark of Philips Electronics N.V. Tag-it TM is a registered trademark of Texas Instruments Incorporated. OBID i-scan ® InstallationID ISC.ANT1700/740-SLA/-SLB FEIG ELECTRONIC GmbHPage 3 of 70M00210-3e-ID-B.doc Contents 1 Safety Instructions / Warning - Read before Start-Up ! 5 2 Maintenance 6 3 Performance Features of the ID ISC.ANT1700/740 SLx Antennas 7 3.1 Performance Features of the People Counter ID ISC.ANT1700/740-GPC ............... 8 3.2 Available Antenna Types ......................................................................................... 11 4 Installation and Wiring 12 4.1 Mounting preparation .............................................................................................. 13 4.2 Dimensions of antenna ............................................................................................ 14 4.3 Drilling the Mounting Holes ..................................................................................... 15 4.4 Installing the Antenna Body ..................................................................................... 17 5 Typical Antenna Configuration (Gate Antenna with two Antennas) 18 5.1 Project Notes ............................................................................................................ 18 5.2 Gate Configuration and Setup using Antennas Type -SLA and -SLB ................... 21 5.2.1 Required Components ........................................................................................... 21 5.2.2 Configuration of a Gate antenna with Multiplexer ................................................... 22 5.2.3 Setting the Multiplexer ............................................................................................ 24 5.2.4 Setting the Antenna Tuner ..................................................................................... 25 5.2.5 Interface Connections ............................................................................................ 26 5.2.5.1 RS 232 ......................................................................................................... 26 5.2.5.2 LAN / TCP/IP ................................................................................................ 27 5.2.6 Reader Configuration with Multiplexer .................................................................... 28 5.2.7 Tuning the Gate Antenna with Multiplexer .............................................................. 31 5.3 Testing the Gate Antenna......................................................................................... 32 5.3.1 Checking the Noise Level ....................................................................................... 32 5.3.2 Reading a Serial Number ....................................................................................... 34 5.3.3 Testing the performance ........................................................................................ 35 OBID i-scan ® InstallationID ISC.ANT1700/740-SLA/-SLB FEIG ELECTRONIC GmbHPage 4 of 70M00210-3e-ID-B.doc 5.4 Setting the Alarm indicators (Alarm sounder and Alarm LED lights) ................... 37 5.4.1 Reader Setting for Indicator.................................................................................... 38 5.4.2 Programming a Transponder with the AFI Byte ...................................................... 40 5.5 Activating the Automatic Mode...............................…
Text truncated - open the document above for the full version.
m. dudde hochfrequenz-technik Rottland 5a, D-51429 Bergisch-Gladbach DIN EN ISO/IEC 17025 zertifiziert Akkreditiertes Testhaus- Reg.-Nr.: DAT-P-225/96-02 Tel. : +49 22 07 - 96 89 - 0 Fax : +49 22 07 - 96 89 - 20 email: [email protected] www.dudde.com Request for Confidentiality Date: 2010-05-16 RE: Certification Application FCC ID: PJMLRM2500 Confidentiality Request To whom it may concern: Pursuant to Sections 0.457 (d) (1) (ii) and 0.459 of the Commission’s Rules, our customer hereby requests confidential treatment of information accompanying as outlined below: Block diagram Block diagram description / Operational description Schematics Parts list The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to our customer and provide unjustified benefits to their competitors. Thank you for your attention in this matter. m. dudde hochfrequenz-technik Andreas Morsbach Assistant Manager
State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Annex no. 1 External Photographs State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 ID ISC.LRM2500-A Upper side RF module State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 ID ISC.LRM2500-A RF module Lower side State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 ID ISC.LRM2500-A Logic board RF module Metal plate State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 ID ISC.LRM2500-B Upper side RF module State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 ID ISC.LRM2500-B RF module Lower side State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 ID ISC.LRM2500-B Logic board RF module Metal plate State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 ID ISC.LRM2500-B ID ISC.LRM2500-A State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 ID ISC.LRM2500-A ID ISC.LRM2500-B State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 ID ISC.LRM2500-A / ID ISC.LRM2500-B Lower Side
State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Annex no. 4 Label Sample OBID i-scan ® Installation ID ISC.LRM2500-B FEIG ELECTRONIC GmbH Page 56 of 59 M01111-0de-ID-B.DOC E N G L I…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Tolerance |
|---|---|---|---|---|
| 1 | 15C | 13.56 MHz - 13.56 MHz | - | 0.0100000000 % |

RFID Reader
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
RFID Reader
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterWireless Safety System for industrial doors - Mobile Unit
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
RFID Reader
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
RFID Reader
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter