Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Date of Grant
Jun 01, 2005
Application Purpose
Original Equipment
Date of Application
Jun 01, 2005
Equipment Note
Inductive Reader
Frequency Range
13.56000000 - 13.56000000
Company
Feig Electronic GmbH
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗
↗
↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

INSTALLATION public (B) 2005-06-02 M50300-1de-ID-B-neu.doc ID ISC.MR101-USB ID ISC.PR101-USB (english) OBIDi-scan  InstallationID ISC.PR / MR101-USB FEIG ELECTRONIC GmbHPage2of14M50300-1de-ID-B-neu.doc E N G L I S H Note Copyright 2005 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg-Waldhausen Tel.: +49 6471 3109-0 http://www.feig.de With the edition of this document, all previous editions become void. Indications made in this man- ual may be changed without previous notice. Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the pay- ment of damages. All rights are reserved in the event of the grant of a patent or the regis- tration of a utility model or design. Composition of the information in this manual has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete infor- mation. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. The installation instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross en- vironments. FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this manual and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others. OBID ® and OBID i-scan ® are registered trademarks of FEIG ELECTRONIC GmbH. I-CODE ® is a registered trademark of Philips Electronics N.V. Tag-it TM is a registered trademark of Texas Instruments Incorporated. OBIDi-scan  InstallationID ISC.PR / MR101-USB FEIG ELECTRONIC GmbHPage3of14M50300-1de-ID-B-neu.doc E N G L I S H Contents 1.Safety instructions / Warning - read before start-up !.........................................................4 2.Performance features of the readers....................................................................................5 2.1.Performance features.....................................................................................................5 2.2.Available reader-types....................................................................................................5 3.Assembly and wiring.............................................................................................................6 3.1.Connector sockets..........................................................................................................6 3.2.USB-Interface connection X3.........................................................................................7 3.3.Power supply (only ID ISC.MR101)................................................................................7 3.4.Antenna terminal X4 (only ID ISC.MR101).....................................................................8 3.5.Starting............................................................................................................................9 3.5.1.ID ISC.MR101...............................................................................................................9 3.5.2.ID ISC.PR101................................................................................................................9 4.Control and display elements.............................................................................................10 4.1.LED.................................................................................................................................10 5.Technical data......................................................................................................................11 6.Approvals..............................................................................................................................13 6.2.USA (FCC)....................................................................................................................13 6.2.Europe (CE).................................................................................................................13 7.Appendix...............................................................................................................................14 7.1.Accessories...................................................................................................................14 7.1.1.Wall mounting kit ID ISC.MS.MR/PR-A.......................................................................14 OBIDi-scan  InstallationID ISC.PR / MR101-USB FEIG ELECTRONIC GmbHPage4of14M50300-1de-ID-B-neu.doc E N G L I S H 1.Safety instructions / Warning - read before start-up ! •The device has to be used only for the purpose designed by the manufacturer. •The operation manual has to be stored available at any time and has to be handed over to each user. •Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such measures will lead to exclusion of any liability by the manufacturer. •The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the device. The manufacturer is not legally responsible for incorrect, unsuitable manual or automatical setting of parameters for a device or the incorrect application of a device. •Repairs can only be executed by the manufacturer. •Installation-, operation- and maintenance procedures should only be carried out by qualified personnel. •Before opening the device, the power supply must always be interrupted. Make sure that the device is without voltage by measuring. CAUTION! The fading of an operation control (LED) is no indicator for an interrupted power supply or the device be…

Text truncated - open the document above for the full version.

Cover Letter(s)

FEIG ELECTRONIC GmbH - Lange Straße 4 - D-35781 Weilburg-Waldhausen account details: Kreissparkasse Weilburg (Bank sorting code No. 511 519 19) Account-No. 100 451 012 IBAN: DE 38511519190100451012 Dresdner Bank Limburg (Bank sorting code No. 513 800 40) Account-No. 9 367 354 00 IBAN: DE 60 5138 0040 0936 7354 00 Managing Director: Dipl.-Ing. Wolfgang Feig Place of Jurisdiction: Limburg HRB 3178 Sales tax-IdNo. DE 811 460 661 VEK Traffic Detectors TST Control technology OBID ® Object identification your signdate of your messageour signyour correspondency partnerdate CFFiedler19.04.2005 To Whom It May Concern: Please be advised that FEIG ELECTRONIC GmbH authorizes Senton GmbH to act on our behalf, until otherwise notified, for applications submitted to PHOENIX TEST-LAB GmbH (PTL). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse ACT of 1988, U.S.C.862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you for your attention to this matter. FEIG ELECTRONIC ______________________________________ Dipl.-Ing. Carsten Fiedler R&D PHOENIX TEST-LAB GmbH Product Certification Königswinkel 10 D 32825 Blomberg FEIG ELECTRONIC GmbH Lange Straße 4 D-35781 Weilburg-Waldhausen Phone:+49 6471/31 09-0 Fax:+49 6471/31 09-99

Cover Letter(s)

Request for Confidentiality in accordance with 47 CFR 0.459 15 April 2005 PHOENIX TEST-LAB GmbH Kˆnigswinkel 10 D32825 Blomberg Germany RE: Certification Application FCC ID: PJMMR101-PR101 Please be advised that the following information is to be held confidential on behalf of FEIG ELECTRONIC GmbH • Schematics • Parts Lists • Block Diagram • Technical Description The application contains technical information which FEIG ELECTRONIC GmbH deems to be trade secrets and proprietary. If made public, the information might be used to the disadvantage of the applicant in the market place. Thank you for your attention to this matter.

External Photos

FCC ID PJMMR101-PR101 ID ISC.MR101 FCC ID PJMMR101-PR101 ID ISC.MR101 FCC ID PJMMR101-PR101 ID ISC.MR101 FCC ID PJMMR101-PR101 ID ISC.MR101

External Photos

FCC ID PJMMR101-PR101 ID ISC.PR101 FCC ID PJMMR101-PR101 ID ISC.PR101 FCC ID PJMMR101-PR101 ID ISC.PR101 FCC ID PJMMR101-PR101 ID ISC.PR101

External Photos

External Photographs ID ISC.MR101 / ID ISC.PR101 1 / 2 File:ID ISCMR101-Internal-Photos.DOC Date:21.03.2005 The reproduction of this document as well as the utilization and communication of its contents are strictly forbidden, as far as not expressly conceded. Any contravention will lead to a liability for damages. All rights reserved for the case of patent grant respectively the registration of a utility or design. External ID ISC.MR101 Front of unit Rear of unit External Photographs ID ISC.MR101 / ID ISC.PR101 2 / 2 File:ID ISCMR101-Internal-Photos.DOC Date:21.03.2005 The reproduction of this document as well as the utilization and communication of its contents are strictly forbidden, as far as not expressly conceded. Any contravention will lead to a liability for damages. All rights reserved for the case of patent grant respectively the registration of a utility or design. External ID ISC.PR101 Front of unit Rear of unit

ID Label/Location Info

Type Label ID ISC.MR101 1/1 File:ID ISCMR101-Type Label.DOC Date:21.03.2005 The reproduction of this document as well as the utilization and communication of its contents are strictly forbidden, as far as not expressly conceded. Any contravention will lead to a liability for damages. All rights reserved for the case of patent grant respectively the registration of a utility or design. Type Label ID ISC.MR101 / ID ISC.PR101 ID ISC.MR101ID ISC.PR101 50mm x 34mm50mm x 34mm Position of the Label (serial number)(serial number)

Internal Photos

Internal Photographs ID ISC.MR101 / ID ISC.PR101 1 / 2 File:ID ISCMR101-Internal-Photos.DOC Date:21.03.2005 The reproduction of this document as well as the utilization and communication of its contents are strictly forbidden, as far as not expressly conceded. Any contravention will lead to a liability for damages. All rights reserved for the case of patent grant respectively the registration of a utility or design. Internal ID ISC.MR101 Front of unit Rear of unit Internal Photographs ID ISC.MR101 / ID ISC.PR101 2 / 2 File:ID ISCMR101-Internal-Photos.DOC Date:21.03.2005 The reproduction of this document as well as the utilization and communication of its contents are strictly forbidden, as far as not expressly conceded. Any contravention will lead to a liability for damages. All rights reserved for the case of patent grant respectively the registration of a utility or design. Internal ID ISC.PR101 Top view of printed board Bottom view of printed board

Test Report

Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Note: The test data of this report is related only to the individual item which has been tested. This report shall not be reproduced except in full extent without the written approval of the testing laboratory. Test Report No. 50602-050112-5 (Edition 1) Page 1 of 47 Pages Straubing, April 1, 2005 T E S T - R E P O R T No. 50602-050112-5 (Edition 1) for ID ISC.MR101 Inductive TAG Reader Applicant: FEIG ELECTRONIC GmbH Test Specifications: FCC Code of Federal Regulations, CFR 47, Part 15, Sections 15.205, 15.207 and 15.225 Industry Canada Radio Standards Specification RSS-210 Issue 5, Sections 6.2.2(e), 6.3 and 6.6 (Category I Equipment) Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-050112-5 (Edition 1) Page 2 of 47 Pages Table of Contents 1 Description of the Equipment Under Test (EUT) ........................................................ 3 2 Administrative Data..................................................................................................... 4 3 Identification of the Test Laboratory ........................................................................... 5 4 Summary .................................................................................................................... 6 5 Operation Mode and Configuration of EUT................................................................. 7 6 Measuring Methods .................................................................................................... 8 6.1 Bandwidth Measurements .................................................................................... 8 6.2 Conducted AC powerline emission..................................................................... 10 6.3 Radiated Emission Measurement 9 kHz to 30 MHz ........................................... 12 6.4 Radiated emission in Fully Anechoic Room ....................................................... 14 6.5 Radiated emission at Open Field Test Site ........................................................ 16 6.6 Carrier Frequency Stability ................................................................................. 17 7 Photographs Taken During Testing .......................................................................... 19 8 Test Results .............................................................................................................. 27 8.1 Occupied Bandwidth........................................................................................... 29 8.2 Emission Bandwidth ........................................................................................... 32 8.3 Designation of Emissions ................................................................................... 34 8.4 Conducted Powerline Emission Measurement 150 kHz to 30 MHz................... 35 8.5 Spectrum mask .................................................................................................. 37 8.6 Radiated Emission Measurement 9 kHz to 30 MHz .......................................... 39 8.7 Radiated Emission Measurement 30 MHz to 1 GHz ......................................... 40 8.8 Carrier Frequency Stability ................................................................................. 42 9 Referenced Regulations ........................................................................................... 46 10 Charts taken during testing ....................................................................................... 47 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-050112-5 (Edition 1) Page 3 of 47 Pages 1 Description of the Equipment Under Test (EUT) General data of EUT Type designation 1 : ID ISC.MR101 Parts 2 : - ID ISC.MR101 - ID ISC.ANT 340/240 Serial number(s): 0852486 Manufacturer: FEIG ELECTRONIC GmbH Type of equipment: Inductive TAG Reader Version: As delivered FCC ID: Additional parts/accessories: --- Technical data of EUT Application frequency range: 13.553 ñ 13.567 MHz Frequency range: 13.553 ñ 13.567 MHz Operating frequency: 13.56 MHz Type of modulation: ASK Pulse train: Not Applicable Pulse width: Not Applicable Number of RF-channels: 1 Channel spacing: Not Applicable Designation of emissions 3 : 10K0A1D Type of antenna: Inductive Loop Coil Size/length of antenna: 340 x 240 mm Type of power supply: DC supply Specifications for power supply: nominal voltage: 12.0 V minimum voltage: 12.0 V maximum voltage: 24.0 V 1 Type designation of the system if EUT consists of more than one part. 2 Type designations of the parts of the system, if applicable. 3 Also known as "Class of Emission". Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-050112-5 (Edition 1) Page 4 of 47 Pages 2 Administrative Data Application details Applicant (full address): FEIG ELECTRONIC GmbH Lange Strafle 4 D-35781 Weilburg-Waldhausen Contact person: Mr. Carsten Fiedler Contract identification: Order no. EB203083 / 16483 Receipt of EUT: 16 th March 2005 Date(s) of test: 16 th March ñ 1 st April 2005 Note(s): Mr. Fiedler attended testings on March, 16 th . Report details Report number: 50602-050112-5 Edition: 1 Issue date: April 1, 2005 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-050112-5 (Edition 1) Page 5 of 47 Pages 3 Identification of the Test Laboratory Details of the Test Laboratory Company name: Senton GmbH EMI/EMC Test Center Address: Aeussere Fruehlingstrasse 45 D-94315 Straubing Germany Laboratory Accreditation: DAR-Registration No. DAT-P-171/94-02 FCC Test Site registration number 90926 Industry Canada Test site registration: IC 3050 Contact person: Mr. Johann Roidt Phone: (+49) (0)9421 5522-0 Fax: (+49) (0)9421 5522-99 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-050112-5 (Edition 1) Page 6 of 47 Pages 4 Summary Summary of test results The tested sample complies with the requirements set forth in the …

Text truncated - open the document above for the full version.

Test Report

Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Note: The test data of this report is related only to the individual item which has been tested. This report shall not be reproduced except in full extent without the written approval of the testing laboratory. Test Report No. 50602-050112-6 (Edition 1) Page 1 of 46 Pages Straubing, April 1, 2005 T E S T - R E P O R T No. 50602-050112-6 (Edition 1) for ID ISC.PR101 Inductive TAG Reader Applicant: FEIG ELECTRONIC GmbH Test Specifications: FCC Code of Federal Regulations, CFR 47, Part 15, Sections 15.205, 15.207 and 15.225 Industry Canada Radio Standards Specification RSS-210 Issue 5, Sections 6.2.2(e), 6.3 and 6.6 (Category I Equipment) Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-050112-6 (Edition 1) Page 2 of 46 Pages Table of Contents 1 Description of the Equipment Under Test (EUT) ........................................................ 3 2 Administrative Data..................................................................................................... 4 3 Identification of the Test Laboratory ........................................................................... 5 4 Summary .................................................................................................................... 6 5 Operation Mode and Configuration of EUT................................................................. 7 6 Measuring Methods .................................................................................................... 8 6.1 Bandwidth Measurements .................................................................................... 8 6.2 Conducted AC powerline emission..................................................................... 10 6.3 Radiated Emission Measurement 9 kHz to 30 MHz ........................................... 12 6.4 Radiated emission in Fully Anechoic Room ....................................................... 14 6.5 Radiated emission at Open Field Test Site ........................................................ 16 6.6 Carrier Frequency Stability ................................................................................. 17 7 Photographs Taken During Testing .......................................................................... 19 8 Test Results .............................................................................................................. 26 8.1 Occupied Bandwidth........................................................................................... 28 8.2 Emission Bandwidth ........................................................................................... 31 8.3 Designation of Emissions ................................................................................... 33 8.4 Conducted Powerline Emission Measurement 150 kHz to 30 MHz................... 34 8.5 Spectrum mask .................................................................................................. 36 8.6 Radiated Emission Measurement 9 kHz to 30 MHz .......................................... 38 8.7 Radiated Emission Measurement 30 MHz to 1 GHz ......................................... 39 8.8 Carrier Frequency Stability ................................................................................. 40 9 Referenced Regulations ........................................................................................... 45 10 Charts taken during testing ....................................................................................... 46 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-050112-6 (Edition 1) Page 3 of 46 Pages 1 Description of the Equipment Under Test (EUT) General data of EUT Type designation 1 : ID ISC.PR101 Variants covered in this test report: - with USB interface - with serial interface Parts 2 : 1 Serial number(s): 6 Manufacturer: FEIG ELECTRONIC GmbH Type of equipment: Inductive TAG Reader Version: As delivered FCC ID: PJMMR101-PR101 Additional parts/accessories: --- Technical data of EUT Application frequency range: 13.553 ñ 13.567 MHz Frequency range: 13.553 ñ 13.567 MHz Operating frequency: 13.56 MHz Type of modulation: ASK Pulse train: Not Applicable Pulse width: Not Applicable Number of RF-channels: 1 Channel spacing: Not Applicable Designation of emissions 3 : 10K0A1D Type of antenna: Integrated Inductive Loop Coil Size/length of antenna: 100 x 70 mm Type of power supply: DC supply Specifications for power supply: nominal voltage: 5.0 V 12.0 V minimum voltage: 4.5 V 12.0 V maximum voltage: 5.5 V 24.0 V 1 Type designation of the system if EUT consists of more than one part. 2 Type designations of the parts of the system, if applicable. 3 Also known as "Class of Emission". Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-050112-6 (Edition 1) Page 4 of 46 Pages 2 Administrative Data Application details Applicant (full address): FEIG ELECTRONIC GmbH Lange Strafle 4 D-35781 Weilburg-Waldhausen Contact person: Mr. Carsten Fiedler Contract identification: Order no. EB203083 / 16483 Receipt of EUT: 16 th March 2005 Date(s) of test: 16 th March ñ 1 st April 2005 Note(s): Mr. Fiedler attended testings on March, 16 th . Report details Report number: 50602-050112-6 Edition: 1 Issue date: April 1, 2005 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-050112-6 (Edition 1) Page 5 of 46 Pages 3 Identification of the Test Laboratory Details of the Test Laboratory Company name: Senton GmbH EMI/EMC Test Center Address: Aeussere Fruehlingstrasse 45 D-94315 Straubing Germany Laboratory Accreditation: DAR-Registration No. DAT-P-171/94-02 FCC Test Site registration number 90926 Industry Canada Test site registration: IC 3050 Contact person: Mr. Johann Roidt Phone: (+49) (0)9421 5522-0 Fax: (+49) (0)9421 5522-99 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-050112-6 (Edition 1) Page 6 of 46 Pages 4 Summary Summ…

Text truncated - open the document above for the full version.

Test Setup Photos

Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-050112-5 (Edition 1) Page 20 of 47 Pages Test setup for conducted AC powerline emission measurement Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-050112-5 (Edition 1) Page 21 of 47 Pages Test setup for radiated emission measurement 9 kHz ñ 30 MHz Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-050112-5 (Edition 1) Page 22 of 47 Pages Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-050112-5 (Edition 1) Page 23 of 47 Pages Test setup for radiated emission measurement (fully anechoic room) Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-050112-5 (Edition 1) Page 24 of 47 Pages Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-050112-5 (Edition 1) Page 25 of 47 Pages Test setup for radiated emission measurement (open field test site) Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-050112-5 (Edition 1) Page 26 of 47 Pages Test setup for carrier frequency stability measurement

Test Setup Photos

Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-050112-6 (Edition 1) Page 20 of 45 Pages Test setup for conducted AC powerline emission measurement Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-050112-6 (Edition 1) Page 21 of 45 Pages Test setup for radiated emission measurement 9 kHz ñ 30 MHz Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-050112-6 (Edition 1) Page 22 of 45 Pages Test setup for radiated emission measurement (fully anechoic room) Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-050112-6 (Edition 1) Page 23 of 45 Pages Test setup for radiated emission measurement (open field test site) Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50602-050112-6 (Edition 1) Page 24 of 45 Pages Test setup for carrier frequency stability measurement

Contact Information

Applicant

Elmar Reichwein(Manager)
[email protected]+49 6471 31090Fax: +49 6471 310999

Technical Contact

Senton GmbHJohann Roidt
[email protected]+49 9421 552213

Aeussere Fruehlingstr. 45 · Straubing · Germany

Test Firm

TUV SUD Product Service GmbH PS-EMC-STRRainer Heller
[email protected]49-09421-5522-20Fax: 49-09421-5522-99

Technical Specifications

#Rule PartsFrequency RangePower OutputTolerance
115C13.56 MHz - 13.56 MHz-0.0100000000 %
Confidentiality
Long Term
Grant Notes
This device approved only for use with the antennas documented in the filing. This device is designed for professional use only.

Other Applications from Feig Electronic GmbH

RFID Reader - FCC ID PJMPRM103 - Feig Electronic GmbH
PJMPRM103

RFID Reader

Feb 25, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
RFID Reader - FCC ID PJMMRM103 - Feig Electronic GmbH
PJMMRM103

RFID Reader

Jan 19, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
PJMTSTFSAMC

Wireless Safety System for industrial doors - Mobile Unit

Dec 01, 2024

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
RFID Reader - FCC ID PJMLRM5400 - Feig Electronic GmbH
PJMLRM5400

RFID Reader

Jun 27, 2023

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
RFID Reader - FCC ID PJMMRU102A - Feig Electronic GmbH
PJMMRU102A

RFID Reader

Jul 07, 2021

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter