FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Feig Electronic GmbH/
  3. PJMPRH200

PJMPRH200RFID Reader

Feig Electronic GmbH
RFID Reader - FCC ID PJMPRH200 - Feig Electronic GmbH
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
May 26, 2014
Application Purpose
Original Equipment
Date of Application
May 19, 2014
Equipment Note
RFID Reader
Frequency Range
13.56000000 - 13.56000000
Company
Feig Electronic GmbH
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Annex no. 5 Functional Description / User Manual INSTALLATION draft – public (B) 2014-04-28 – M31210-2e-ID-B.docx ID ISC.PRH200 Mobile Reader (English) OBID i-scan ® HF Installation ID ISC.PRH200 FEIG ELECTRONIC GmbH Page 2 from 37 M31210-2e-ID-B.docx Note  Copyright 2014 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg Tel.: +49 6471 3109-0 http://www.feig.de With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design. Composition of the information in this document has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments and does not give any guaranty for the functionality of the complete system which incorporates the subject of this document. FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to a human. To avoid damage, injury, or death, the user or application designer must take reasonably prudent steps to protect against system failures. FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this docu- ment and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others. OBID ® and OBID i-scan ® are registered trademarks of FEIG ELECTRONIC GmbH. my-d ® is a registered trademark of Infineon Technologies AG I-CODE ® is a registered trademark of Philips Electronics N.V. Tag-it TM is a registered trademark of Texas Instruments Incorporated. OBID i-scan ® HF Installation ID ISC.PRH200 FEIG ELECTRONIC GmbH Page 3 from 37 M31210-2e-ID-B.docx Contents 1 Safety Instructions / Warning - Read before Start-Up 5 1.1 Safety Instructions / Warning - Lithium-ion battery ................................................. 6 1.2 Lithium-ion batteries – Return and Transport .......................................................... 7 1.3 Maintenance ................................................................................................................ 8 1.4 Assembly of the wrist strap ....................................................................................... 8 2 Performance Features of the mobile Reader ID ISC.PRH200 9 2.1 Performance Features ................................................................................................ 9 2.2 Available Reader Types ............................................................................................ 10 2.3 Available Spare Parts ............................................................................................... 10 2.4 Delivery contents ...................................................................................................... 10 3 Start-up 11 3.1 Side view, Button & LED‘s ....................................................................................... 11 3.2 Charge the battery .................................................................................................... 12 4 First Wi-Fi connection with the Reader and scanning transponder 13 4.1 Connection in Access point Mode ........................................................................... 13 4.2 How to configure the Reader in client mode ........................................................... 16 4.3 Set Wi-Fi parameter to default ................................................................................. 18 4.4 Wi-Fi Interfaces ......................................................................................................... 20 5 Control and Display Elements 21 5.1 Buttons ...................................................................................................................... 21 5.1 HF-ON Motion Detector ............................................................................................ 22 5.2 LEDs .......................................................................................................................... 23 5.3 Buzzer ........................................................................................................................ 24 6 Configuration and testing the Reader using ISOStart 25 OBID i-scan ® HF Installation ID ISC.PRH200 FEIG ELECTRONIC GmbH Page 4 from 37 M31210-2e-ID-B.docx 7 Approvals 30 7.1 Europe (CE) ............................................................................................................... 30 7.2 USA (FCC) and Canada (IC) ..................................................................................... 31 7.3 Label Information Reader ID ISC.PRH200 ............................................................... 33 7.3.1 USA (FCC) and Canada (IC) approved antennas ................................................... 34 8 Technical Data 35 OBID i-scan ® HF Installation ID ISC.PRH2…

Text truncated - open the document above for the full version.

External Photos

Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Annex no. 1 External Photographs Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920

ID Label/Location Info

Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Annex no. 4 Label Sample Label position ID ISC.PRH200 1 / 1 Fi le : ID ISCPRH200 – Label position.DOC Date : 28.04.2014 The reproduction of this document as well as the utilization and communication of its contents are strictly forbidden, as far as not expressly conceded. Any contravention will lead to a liability for damages. All rights reserved for the case of patent grant respectively the registration of a utility or design. Confidential ID ISC.PRH200 ID ISC.PRH200 – Side view ID ISC.PRH200 - Back side

Internal Photos

Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Annex no. 2 Internal Photographs Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920

RF Exposure Info

RF exposure calculation 8.8.1 Regulation Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission's guidelines. 8.8.2 Test result MPE calculation to the FCC no: QOQWF121 in combination with PJMPRH200 These equations are generally accurate in the far field of an antenna but will over predict power density in the near field, where they could be used for making a “worst case” prediction. S = PG/4πR 2 where S = power density ( in appropriate units, e.g. mW/cm 2 ) P = power input to the antenna (in appropriate units e.g. mW) G = power gain of the antenna in the direction of interest relative to the isotropic radiator R = distance to the center of radiation of the antenna (appropriate units e.g. cm) Or S = EIRP/(4πR 2 ) where EIRP = equivalent isotropically radiated power Maximum measured power for WiFi = 18.7 dBm EIRP Calculation: (Calculated for max. EIRP) EIRP: 18.7 dBm = 74.1 mW calculated at distance of 20 cm: power density = 74.1 /(4*π*20 2 ) = 0.0147 mW/ cm 2 Limit: ± 1.0 mW/ cm 2 is the reference level for general public exposure according to the OET Bulletin 65, Edition 97-01 Table 1..

Test Report

Test report no. 14009146 Page 1 of 32 EUT: ID ISC.PRH200 FCC ID: PJMPRH200 Date of issue: 2014-04-15 Date: 2014-04-11 Vers. no. 1.14 dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Test Report acc. to FCC Title 47 CFR Part 15 relating to FEIG ELECTRONIC GmbH ID ISC.PRH200 Title 47 - Telecommunication Part 15 - Radio Frequency Devices Subpart C – Intentional Radiators Measurement Procedure: ANSI C63.4-2009 Test report no. 14009146 Page 2 of 32 EUT: ID ISC.PRH200 FCC ID: PJMPRH200 Date of issue: 2014-04-15 Date: 2014-04-11 Vers. no. 1.14 dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Manufacturer’s details Manufacturer FEIG ELECTRONIC GmbH Manufacturer’s grantee code PJM Manufacturer’s address FEIG ELECTRONIC GmbH Lange Str. 4 35781 Weilburg Germany Phone: +49 (0) 6471 3109 0 Fax: +49 (0) 6471 3109 99 Email: [email protected] Relevant standard used 47 CFR Part 15C - Intentional Radiators ANSI C63.4-2009 Test Report prepared by Technical engineer Ralf Trepper m. dudde hochfrequenz-technik (laboratory) Rottland 5a 51429 Bergisch Gladbach Germany Phone: +49 2207 96890 Fax: +49 2207 968920 Email: [email protected] Equipment Under Test (EUT) Equipment category Inductive application / RFID Trade name OBID i-scan Type designation ID ISC.PRH200 Serial no. --- Variants --- Test report no. 14009146 Page 3 of 32 EUT: ID ISC.PRH200 FCC ID: PJMPRH200 Date of issue: 2014-04-15 Date: 2014-04-11 Vers. no. 1.14 dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 1. Test results Clause Requirements headline Test result Report page number 8.1 Antenna Requirement Pass Fail N.t.* 9 8.2 Conducted limits Pass Fail N.t.* 10 to 12 8.3 Restricted bands of operation Pass Fail N.t.* 13 to 14 8.4 Radiated emission limits Pass Fail N.t.* 15 to 24 8.5 Frequency tolerance Pass Fail N.t.* 25 to 28 8.6 20 dB Bandwidth Pass Fail N.t.* 29 to 30 * Not tested The equipment passed the conducted tests Yes No Signature: ............................. Signature: ...................................... (Technician) (Laboratory Manager) Test report no. 14009146 Page 4 of 32 EUT: ID ISC.PRH200 FCC ID: PJMPRH200 Date of issue: 2014-04-15 Date: 2014-04-11 Vers. no. 1.14 dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Table of contents 1. Test results ........................................................................................................................................................ 3 2. Introduction ...................................................................................................................................................... 5 3. Testing laboratory ............................................................................................................................................ 5 4. Applicant .......................................................................................................................................................... 6 5. Product and product documentation ................................................................................................................ 6 6. Conclusions, observations and comments ........................................................................................................ 7 7. Operational description ...................................................................................................................................... 8 8. Compliance assessment ..................................................................................................................................... 9 8.1 Antenna requirement ....................................................................................................................................... 9 8.1.1 Regulation ............................................................................................................................................. 9 8.1.2 Result .................................................................................................................................................... 9 8.2 Conducted limits ............................................................................................................................................ 10 8.2.1 Regulation ............................................................................................................................................. 10 8.1.2 Test equipment ...................................................................................................................................... 11 8.2.3 Test procedures ..................................................................................................................................... 11 8.2.4 Result .................................................................................................................................................... 12 8.3 Restricted bands of operation ......................................................................................................................... 13 8.3.1 Regulation ............................................................................................................................................. 13 8.3.2 Result .................................................................................................................................................... 14 8.4 Radiated emission limits ................................................................................................................................ 15 8.4.1 Regulation ............................................................................................................................................. 15 8.4.2 Test equipment ............................................................................…

Text truncated - open the document above for the full version.

Test Report

Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Annex no. 3 Occupied Bandwidth Plot Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 20 dB bandwidth Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 99 % bandwidth

Test Setup Photos

Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Annex no. 6 Test Setup Photographs Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920

Contact Information

Applicant

Elmar Reichwein(Manager)
[email protected]+49 6471 31090Fax: +49 6471 310999

Technical Contact

FEIG ELECTRONIC GmbHElmar Reichwein
49 6471 31090

Germany

Non-Technical Contact

FEIG ELECTRONIC GmbHElmar Reichwein
49 6471 31090

Test Firm

TUEV NORD Hochfrequenztechnik GmbH & Co. KGRalf Trepper
[email protected]+49 221 / 88889518Fax: +49 221 / 88889595

Technical Specifications

#Rule PartsFrequency RangePower Output
115C13.56 MHz - 13.56 MHz-
Confidentiality
Long Term

Other Applications from Feig Electronic GmbH

RFID Reader - FCC ID PJMPRM103 - Feig Electronic GmbH
PJMPRM103

RFID Reader

Feb 25, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
RFID Reader - FCC ID PJMMRM103 - Feig Electronic GmbH
PJMMRM103

RFID Reader

Jan 19, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
PJMTSTFSAMC

Wireless Safety System for industrial doors - Mobile Unit

Dec 01, 2024

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
RFID Reader - FCC ID PJMLRM5400 - Feig Electronic GmbH
PJMLRM5400

RFID Reader

Jun 27, 2023

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
RFID Reader - FCC ID PJMMRU102A - Feig Electronic GmbH
PJMMRU102A

RFID Reader

Jul 07, 2021

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter