Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Operator Manual SL58-P Loop Detector for the Peek ADR Series Traffic Recorders 11/19/2012 p/n: 99-578 Rev 1 © 2012 Peek Traffic Corporation, a Signal Group company All rights reserved. Information furnished here is believed to be accurate and reliable, however Peek Traffic does not warranty the accuracy, completeness, or fitness for use of any of the information furnished. No license is granted by implication or otherwise under any intellectual property. Peek reserves the right to alter any of the Company's products or published technical data relating thereto at any time without notice. The information contained within this manual is intended to serve as a guide to users in the operation of the SL58-P Loop Detector. An effort has been made to insure the accuracy of the information contained in this manual. However, the information is supplied without warranty of any kind. Further, there is no warranty of the applicability of the information to all cases. The SL58-P loop detector card has been designed and certified to operate within limits and a frequency range compliant with FCC and IC regulations. Model : SL58-P FCC ID : PMN-SL58P IC : 10596A-SL58P This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. The IC & FCC ID are labeled on the SL58-P. When the SL58-P is installed in an ADR unit, a screw driver may be used to open the ADR unit to view this label. This unit must be installed and operated as specified in this manual. Any changes or modifications not expressly approved by Peek Traffic could void the user's authority to operate the equipment. The user is cautioned to fully program and thoroughly test the controller for its intended application prior to placing it in operational service. Peek Traffic reserves the right to add, delete, and/or modify the material in this manual at any time. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or via any electronic or mechanical means for any purpose other than the purchaser’s personal use without the expressed, written permission of Peek Traffic Corporation. Peek Traffic Corporation 2906 Corporate Way Palmetto, FL 34221 U.S.A. Trademarks ADR-1000, ADR -2000, ADR -3000, ADR –Sabre and SL58-P Loop Detector are trademarks or registered trademarks of Peek Traffic Corporation, a Signal Group company, in the USA and other countries. Microsoft and Windows are trademarks or registered trademarks of Microsoft Corporation. Other brands and their products are trademarks or registered trademarks of their respective holders and should be noted as such. SL-58P Loop Detector Operating Manual iii ABOUT THIS MANUAL This is the operator manual for Peek Traffic Corporation’s SL58-P Loop Detector™. This manual provides: General information regarding the installation of the SL58-P Loop Detector, power- up, and operation Guidelines for installing and connecting inductive road loops Instructions for operating the loop detection within FCC compliance limits Instructions for using the SL58-P LED indicators and buttons Instructions for making adjustments to Loop Detector loop frequencies, and other settings Glossary Index iv SL-58P Loop Detector Operating Manual ADDITIONAL GUIDANCE For more guidance on the configuration and use of the Peek ADR Series traffic recorders, and related devices, refer to the following documents and contacts. Documentation These documents provide useful information concerning ADR Series traffic recorders. Table 1 — Additional documentation available for ADR products Document Part Number ADR-6000 Operating Manual 99-273 ADR-Plus Operating Manual 99-133 Technical Support Use this information to contact the technical support staff of Peek Traffic Corporation, should you require additional help concerning IQ Connect devices. Peek Traffic Corporation - Customer Service Center 2906 Corporate Way Palmetto, FL 34221 toll free in the U.S.: 1 (800) 245-7660 tel: 1 (941) 845-1200 fax: 1 (941) 845-1504 email: [email protected] SL-58P Loop Detector Operating Manual v Contents About this Manual ............................................................................................................ iii Additional Guidance ........................................................................................................ iv Documentation ............................................................................................................................ iv Technical Support ........................................................................................................................ iv Contents ............................................................................................................................ v Table of Figures ............................................................................................................... vi Chapter 1 — Introduction ................................................................................................. 1 Overview ............................................................................................................................ 1 Features .......................................................................................................................................... 1 Detector Installation Notes ............................................................................................... 2 Chapter 2 — Using the Detector ...................................................................................... 3 Basic Detector Operation ........................................................................…
Text truncated - open the document above for the full version.
FCC ID Label SL58-P 0.005”0.5° CorelDraw x5 DO NOT SCALE. IF IN DOUBT, ASK. 60-479 60-479 This document and the information it contains are the property of Peek Traffic and are proprietary and confidential to Peek. Any unauthorized publication, copying, use, reproduction, disclosure, or dissemination of the document or information by any means (including electronic means) is prohibited. SHEET 1 OF 1 1 : 1 DRAWING No. DRAWING PRODUCED IN NO MANUAL ALTERATION mm CHANGE # DIM: LINEARANGULAR 2906 CORPORATE WAY PALMETTO, FLORIDA 34221, USA TITLE: MATERIAL: SURFACE FINISH: TOLERANCE, UNLESS OTHERWISE STATED: SCALE:DRAWING NO. REVDRAWN BYDATECHECKED BYDATEAPPVD BYDATE ECN5228 1NAJ 09-25-12 Model:SL58-P FCC ID:PMN-SL58P IC:10596A-SL58P This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 3.000" 0.300" TEXT SIZE 5 Pt BOLD TEXT SIZE 4PT STANDARD NOTES: 1: LABEL COLOR: WHITE 2: TEXT COLOR: BLACK 3: WHITE POLYESTER MYLAR 0.007” WITH 0.002” PERMANENT ACRYLIC PRESURE SENSITIVE ADHESIVE (3M 9502 OR EQUIVALENT) 4: LABEL TO BE TRIMMED TO CROP MARKS, REFER TO NOTES REFER TO NOTES
Label Location
Internal Photos FCC ID: PMN-SL58P FCC ID: PMN-SL58P Internal Photos
Test Report Number 12F283 Product Safety Engineering, Inc 12955 Bellamy Brothers Blvd. Dade City, FL 33525 Tel (352) 588-2209 Fax (352) 588-2544 Page 2 of 13 D I R E C T O R Y - EMISSIONS Page(s) A)Documentation Test report1 - 11 Test Regulations2 Test Result Summary3 General Remarks11 Test-setups (Photos)12 - 13 B)Test data Conducted emissions10/150 kHz - 30 MHz5, 9 Radiated emissions10 kHz - 30 MHz5, 9 Radiated emissions30 MHz - 1000 MHz6, 9 Interference power30 MHz - 300 MHz6, 9 Equivalent Radiated emissions1 GHz - 18 GHz7, 9 Antenna Disturbance Voltage30 MHz - 1,000 MHz7,9 C)Appendix A Test Data Sheets A2 - A7 D)Appendix B System Under Test DescriptionB2 - B2 E) Appendix C Measurement Protocol C1 - C2 Test Report Number 12F283 Product Safety Engineering, Inc 12955 Bellamy Brothers Blvd. Dade City, FL 33525 Tel (352) 588-2209 Fax (352) 588-2544 Page 3 of 13 FCC / IC Test Results Summary TestRequirementMeasuredPass/FailData Page(s) Radiated emissions limit per 15.209 Intentional Radiator (9- 490) kHz = 2400/f(kHz) uV/m @ 3 meters See data Pass Conducted emissions limit15.107 & 15.207N/A (battery only)Pass Restricted bands15.205None in bandsPass CE Test Results Summary TestRequirementMeasuredPass/FailData Page(s) Permitted range of operating frequencies (9) kHz to (30) MHz (49.6 - 84.2) kHz Pass Permitted range of modulation bandwidth 23 dB below the carrier0 HzPass Emission LimitsTable 5 - 300 330-1See dataPass Transmitter spurious and out of band emissions per 7.5.2 Product Class 3 onlyN/APass Effective radiated powerTable 9 - 300 330-1NonePass Revision History RevisionDateDescription - --08/30/2012Initial Release Test Report Number 12F283 Product Safety Engineering, Inc 12955 Bellamy Brothers Blvd. Dade City, FL 33525 Tel (352) 588-2209 Fax (352) 588-2544 Page 4 of 13 EMISSIONS TEST REGULATIONS : The emissions tests were performed according to following regulations: 9 - EN 61000-6-3:2007 9 - EN 61000-6-4:2007 9 - EN 55011 : 2009/A1:20109 - Group 19 - Group 2 9 - Class A9 - Class B # - EN ETSI 300 330-1 V1.7.1 # - EN ETSI 300 330-2 V1.5.1 9 - EN 55014 -1: 20069 - Household appliances and similar 9 - Portable tools 9 - Semiconductor devices 9 - EN 55022:20109 - Class A9 - Class B 9 -AS/NZS CISPR 229 - Class A9 - Class B # - RSS-GEN9 - Class A9 - Class B 9 - CNS 134389 - Class A9 - Class B 9 - VCCI V-3/2010.49 - Class A9 - Class B # - FCC Part 15 (per ANSI C63.4)9 - Class A9 - Class B # - Certification 9 - Verification 9 - Declaration of Conformity 9 - FCC Part 18 Test Report Number 12F283 Product Safety Engineering, Inc 12955 Bellamy Brothers Blvd. Dade City, FL 33525 Tel (352) 588-2209 Fax (352) 588-2544 Page 5 of 13 Environmental conditions during testing: LAB OATS Temperature: * _________: ________ Relative Humidity: ** _________: ________ * The ambient temperature during the testing was within the range of (50 o - 104 o F) unless indicted above. ** The humidity levels during the testing was within the range of (10% - 90%) relative humidity unless indicated above. Power supply system: * Volts Hz phase * Internal Battery Sign Explanations: - not applicable - applicable Test Report Number 12F283 Product Safety Engineering, Inc 12955 Bellamy Brothers Blvd. Dade City, FL 33525 Tel (352) 588-2209 Fax (352) 588-2544 Page 6 of 13 Emissions Test Conditions: CONDUCTED EMISSIONS ( Interference Voltage) The C ONDUCTED EMISSIONS (INTERFERENCE VOLTAGE) measurements were performed at the following test location: - Test not applicable - Darby Test Site (Open Area Test Site) - Darby Laboratory Test equipment used : Model NumberManufacturerDescriptionSerial Number - 8028-50Solar50 LISN829012, 829022 - 8012Solar50 LISN924840 - EMC-30Electro-MetricsEMI Receiver191 - 8566BHewlett-PackardSpectrum Analyzer2421A00526 -85650AHewlett-PackardQuasi-Peak Adapter2043A00209 -85662AHewlett Packard Analyzer Display2403A07352 -8028-50Solar50 LISN903725, 903726 -FCC-TLISN-T4-02Fisher Custom Com.Telecom ISN20454 - - FCC-TLISN-T8-02 LI-125 Fisher Custom Com. Com-Power Telecom ISN 50 LISN 20452 191080/191081 Emissions Test Conditions: RADIATED EMISSIONS (Magnetic Field) The R ADIATED EMISSIONS (MAGNETIC FIELD) measurements were performed at the following test location: - Darby Test Site (Open Area Test Site) - - at a test distance of : - 3 meters - 30 meters - Test not applicable Test equipment used : Model NumberManufacturerDescriptionSerial Number -3148EMCOLog Periodic Antenna00044783 -BIA-25Electro-MetricsBiconical Antenna4283 -8566BHewlett-PackardSpectrum Analyzer2421A00526 -85662AHewlett-PackardAnalyzer Display2403A07352 -85650AHewlett-PackardQuasi-Peak Adapter2043A00209 -ALR-30MElectro-MetricsLoop Antenna824 -8447DHewlett PackardPreamplifier2944A06832 - - EMC-30 ALA-130/A Electro-Metrics Antenna Research EMI Receiver Loop Antenna 191 106 Test Report Number 12F283 Product Safety Engineering, Inc 12955 Bellamy Brothers Blvd. Dade City, FL 33525 Tel (352) 588-2209 Fax (352) 588-2544 Page 7 of 13 Emissions Test Conditions: RADIATED EMISSIONS ( Electric Field) The RADIATED EMISSIONS (ELECTRIC FIELD) measurements, in the frequency range of 30 MHz-1000 MHz, were tested in a horizontal and vertical polarization at the following test location : - Test not applicable - Darby Site (Open Area Test Site) - Darby Lab - at a test distance of : - 3 meters - 10 meters - 30 meters Test equipment used : Model NumberManufacturerDescriptionSerial Number -HLP 3003CEMC AutomationHybrid Periodic Antenna017501 -8447DHewlett-PackardPreamplifier (26dB)1937A03247 -8566BHewlett-PackardSpectrum Analyzer2421A00526 -85662AHewlett-PackardAnalyzer Display2403A07352 -85650AHewlett-PackardQuasi-Peak Adapter2043A00209 -BIA 25 Electro-Metrics Biconical Antenna4283 -EMC-30Electro-MetricsEMI Receiver191 - - - - - 8568B 85650A 85662A LPA30 3104C Hewlett Packard Hewlett Packard Hewlett Packard Electro-Metrics Emco Spectrum Analyzer Quasi-Peak Ad…
Text truncated - open the document above for the full version.
Test Report Number 12F283 Product Safety Engineering, Inc 12955 Bellamy Brothers Blvd. Dade City, FL 33525 Tel (352) 588-2209 Fax (352) 588-2544 Page 12 of 12 Test-setup photo(s): Radiated emission 30 MHz - 1000 MHz
Setup Photos FCC ID: PMN-SL58P FCC ID: PMN-SL58P Setup Photos
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.048 MHz - 0.086 MHz | - |