Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Ssentech Co.,Ltd. 14F. Daegak Bldg., 1319-5 Seocho-dong, Seocho-gu, Seoul, Korea Tel :+82 2 3474 8080 Fax:+82 2 3474 8102 June 8, 2001 Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 To whom it may concern: We, the undersigned, hereby authorize Celltech Research Inc., to act on our behalf in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. Any and all acts carried out by Celltech Research Inc. on our behalf shall have the same effect as acts of our own. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S. C. 853(a). Sincerely, David Kim Manager of Mobile Communication R&D Lab. Ssentech Co.,Ltd. Ssentech Co.,Ltd. 14F. Daegak Bldg., 1319-5 Seocho-dong, Seocho-gu, Seoul, Korea Tel :+82 2 3474 8080 Fax:+82 2 3474 8102 AFFIDAVIT FOR ESN PROTECTION OF CELLULAR MOBILE TELEPHONES We hereby certify that the Handheld Portable Cellular Telephone FCC ID: PPPCWH-100 is so designed that it complies with all the requirements for ESN protection specified in Section 22.919 of the FCC Rules. a) The transmitter in service has a unique ESN. b) The ESN host component is permanently attached to a main circuit board of the mobile transmitter and the integrity of the unit operating software cannot be altered. The ESN is plated from fraudulent contact and tampering. The ESN is encoded using multiplication by a polynomial and the ESN data programmed in the memory with other information. C) The ESN is factory-set and cannot be altered, transferred, removed or otherwise able to be manipulated. Cellular mobile equipment is specifically designed such that any attempt to remove, tamper with, or change the ESN chip, its logic system, or firmware originally programmed by the manufacturer will render the mobile transmitter inoperative. Sincerely, David Kim Manager of Mobile Communication R&D Lab. Ssentech Co.,Ltd.
July 30, 2001 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Attn: Joe Dichoso Confirmation of Maximum Conducted Power Level Dear Joe, We hereby confirm that the conducted power level of 24.8dBm, which was the conducted power level set for Ssentech Model: CWH-100 single-band single-mode CDMA cellular phone (FCC ID: PPPCWH-100) during testing performed at Celltech Labs in this filing, will be the maximum conducted power level set for all production units. If you have any questions regarding this matter, please do not hesitate to contact me. Sincerely, David Kim Manager of Mobile Communication R&D Lab Ssentech Co., Ltd. Ssentech Co.,Ltd. 14F. Daegak Bldg., 1319-5 Seocho-dong, Seocho-gu, Seoul, Korea Tel :+82 2 3474 8080 Fax:+82 2 3474 8102
Celltech Research Inc. 1955 Moss Court, Kelowna, B.C. Canada V1Y 9L3 Tel. 250-860-3130 •• Fax. 250-860-3110 •• email: [email protected] www.celltechlabs.com June 14, 2001 Federal Communications Commission Equipment Approval Services 7435 Oakland Mills Road Columbia, MD 21046 SUBJECT: SSENTECH CO., LTD. FCC ID: PPPCWH-100 Part 22 Certification Gentlemen: On behalf of SSENTECH CO., LTD. we hereby submit an application for Part 22 Certification of the Ssentech Single-Mode CDMA Cellular Phone as follows: FCC ID: PPPCWH-100 Model(s): CWH-100 Equipment Class: Licensed Non-Broadcast Transmitter Held to Ear (TNE) Equipment Type: Single-Mode CDMA Cellular Phone Tx Freq. Range: 824.70 - 848.31 MHz Rx Freq. Range: 869.70 - 893.31 MHz Max. RF Output Power: 0.251 Watts (ERP) Emission Designator(s): 1M25F9W Attached is the Letter of Authorization, Confidentiality Request, ESN Affidavit, Part 22 measurement report data and test plots, RF exposure measurement report data & photographs, FCC ID label and location, test setup photographs, internal and external photographs, block diagram (confidential), circuit diagrams (confidential), circuit description (confidential), antenna specifications (confidential), parts list (confidential), tune-up procedure (confidential), and the user's manual with RF exposure warning statement. If you have any questions or comments concerning the above, please do not hesitate to contact me. Sincerely, Shawn McMillen General Manager Celltech Research Inc. Testing & Engineering Lab cc: Ssentech Co., Ltd. Ssentech Co.,Ltd. 14F. Daegak Bldg., 1319-5 Seocho-dong, Seocho-gu, Seoul, Korea Tel :+82 2 3474 8080 Fax:+82 2 3474 8102 June 8, 2001 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Re: Ssentech Co., Ltd. FCC ID: PPPCWH-100 FCC Part 22 Certification Request for Confidentiality Gentlemen: In accordance with 0.459 of CFR 47, Ssentech Co., Ltd. hereby requests confidentiality of the block diagram, circuit diagrams, circuit description, operational description, antenna specifications, parts list, and tune-up procedure attachments for the subject application. These documents contain detailed system and equipment description and related information about the product in which Ssentech Co., Ltd. considers to be proprietary, confidential, and a custom design and, otherwise, would not release to the general public. Since this design is a basis from which future technological products will evolve, Ssentech Co., Ltd. considers that this information would be of benefit to its competitors, and that the disclosure of the information in these documents would give competitors an unfair advantage in the market. Sincerely, David Kim Manager of Mobile Communication R&D Lab. Ssentech Co.,Ltd.
Celltech Research Inc. 1955 Moss Court, Kelowna, B.C. Canada V1Y 9L3 Tel. 250-860-3130 •• Fax. 250-860-3110 •• [email protected] www.celltechlabs.com August 02, 2001 Federal Communications Commission Equipment Approval Services 7435 Oakland Mills Road Columbia, MD 21046 Attn: Joe Dichoso SUBJECT: SSENTECH CO., LTD. FCC ID: PPPCWH-100 731 Confirmation No.: EA101362 Correspondence Ref. No.: 20097 Dear Joe: On behalf of Ssentech Co., Ltd. is our amendment per your e-mail dated July 27, 2001 requesting additional information for the subject application. 1. Attached is the revised block diagram with oscillators and frequencies. 2. Attached are the resubmitted circuit diagrams. 3. Please note that this device operates in the cellular CDMA frequency band only, therefore modulation characteristics measurements per Section 2.1047 are not applicable for this filing. Please find attached revised circuit description and operational description attachments with references to FM modulation removed. 4. The measured conducted output power of the device is 24.8dBm across the band (see page 4 of Part 22 test report attachment). Please see attached letter from the applicant confirming the 24.8dBm conducted power level to be set for all production units. If you have any questions or comments concerning the above, please do not hesitate to contact me. Sincerely, Shawn McMillen General Manager Celltech Research Inc. Testing & Engineering Lab cc: Wide Telecom Inc.
Celltech Research Inc. 1955 Moss Court, Kelowna, B.C. Canada V1Y 9L3 Tel. 250-860-3130 •• Fax. 250-860-3110 •• [email protected] www.celltechlabs.com August 10, 2001 Federal Communications Commission Equipment Approval Services 7435 Oakland Mills Road Columbia, MD 21046 Attn: Joe Dichoso SUBJECT: SSENTECH CO., LTD. FCC ID: PPPCWH-100 731 Confirmation No.: EA101362 Correspondence Ref. No.: 20160 Dear Joe: On behalf of Ssentech Co., Ltd. is an amendment per your e-mail dated August 06, 2001 requesting additional information for the subject application. 1. According to the applicant, the block diagram should contain two oscillators, which are U105 (19.88MHz) and X300 (32.768MHz). Attached is the revised block diagram showing both oscillators and frequencies. 2. Please find attached the revised Page 2 of the Part 22 test report addressing the modulation characteristics per Section 2.1047 of the FCC Rules. If you have any questions or comments concerning the above, please do not hesitate to contact me. Sincerely, Shawn McMillen General Manager Celltech Research Inc. Testing & Engineering Lab cc: Ssentech Co., Ltd.
CELLTECH RESEARCH INC. Test Report S/N: 052501-119PPP 1955 Moss Court, Kelowna Dates of Tests: June 04-06, 2001 B.C. Canada V1Y 9L3 FCC Part 22 Certification © 2001 Celltech Research Inc. SSENTECH CO., LTD. FCC ID: PPPCWH-100 Single-Mode CDMA Cellular Phone (824-849MHz) EXTERNAL EUT PHOTOGRAPHS CELLTECH RESEARCH INC. Test Report S/N: 052501-119PPP 1955 Moss Court, Kelowna Dates of Tests: June 04-06, 2001 B.C. Canada V1Y 9L3 FCC Part 22 Certification © 2001 Celltech Research Inc. SSENTECH CO., LTD. FCC ID: PPPCWH-100 Single-Mode CDMA Cellular Phone (824-849MHz) EXTERNAL EUT PHOTOGRAPHS CELLTECH RESEARCH INC. Test Report S/N: 052501-119PPP 1955 Moss Court, Kelowna Dates of Tests: June 04-06, 2001 B.C. Canada V1Y 9L3 FCC Part 22 Certification © 2001 Celltech Research Inc. SSENTECH CO., LTD. FCC ID: PPPCWH-100 Single-Mode CDMA Cellular Phone (824-849MHz) EXTERNAL EUT PHOTOGRAPHS CELLTECH RESEARCH INC. Test Report S/N: 052501-119PPP 1955 Moss Court, Kelowna Dates of Tests: June 04-06, 2001 B.C. Canada V1Y 9L3 FCC Part 22 Certification © 2001 Celltech Research Inc. SSENTECH CO., LTD. FCC ID: PPPCWH-100 Single-Mode CDMA Cellular Phone (824-849MHz) EXTERNAL EUT PHOTOGRAPHS CELLTECH RESEARCH INC. Test Report S/N: 052501-119PPP 1955 Moss Court, Kelowna Dates of Tests: June 04-06, 2001 B.C. Canada V1Y 9L3 FCC Part 22 Certification © 2001 Celltech Research Inc. SSENTECH CO., LTD. FCC ID: PPPCWH-100 Single-Mode CDMA Cellular Phone (824-849MHz) BODY HOLSTER PHOTOGRAPHS
CELLTECH RESEARCH INC. Test Report S/N: 052501-119PPP 1955 Moss Court, Kelowna Dates of Tests: June 04-06, 2001 B.C. Canada V1Y 9L3 FCC Part 22 Certification © 2001 Celltech Research Inc. SSENTECH CO., LTD. FCC ID: PPPCWH-100 Single-Mode CDMA Cellular Phone (824-849MHz) FCC ID LABEL & LOCATION LABELLING REQUIREMENTS PER §§ 2.925 The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time of purchase. CDMA PHONE MODEL: CWH-100 FCC ID: PPPCWH-100 SERIAL NO.: MADE IN KOREA
CELLTECH RESEARCH INC. Test Report S/N: 052501-119PPP 1955 Moss Court, Kelowna Dates of Tests: June 04-06, 2001 B.C. Canada V1Y 9L3 FCC Part 22 Certification © 2001 Celltech Research Inc. SSENTECH CO., LTD. FCC ID: PPPCWH-100 Single-Mode CDMA Cellular Phone (824-849MHz) INTERNAL EUT PHOTOGRAPHS CELLTECH RESEARCH INC. Test Report S/N: 052501-119PPP 1955 Moss Court, Kelowna Dates of Tests: June 04-06, 2001 B.C. Canada V1Y 9L3 FCC Part 22 Certification © 2001 Celltech Research Inc. SSENTECH CO., LTD. FCC ID: PPPCWH-100 Single-Mode CDMA Cellular Phone (824-849MHz) INTERNAL EUT PHOTOGRAPHS CELLTECH RESEARCH INC. Test Report S/N: 052501-119PPP 1955 Moss Court, Kelowna Dates of Tests: June 04-06, 2001 B.C. Canada V1Y 9L3 FCC Part 22 Certification © 2001 Celltech Research Inc. SSENTECH CO., LTD. FCC ID: PPPCWH-100 Single-Mode CDMA Cellular Phone (824-849MHz) INTERNAL EUT PHOTOGRAPHS CELLTECH RESEARCH INC. Test Report S/N: 052501-119PPP 1955 Moss Court, Kelowna Dates of Tests: June 04-06, 2001 B.C. Canada V1Y 9L3 FCC Part 22 Certification © 2001 Celltech Research Inc. SSENTECH CO., LTD. FCC ID: PPPCWH-100 Single-Mode CDMA Cellular Phone (824-849MHz) INTERNAL EUT PHOTOGRAPHS CELLTECH RESEARCH INC. Test Report S/N: 052501-119PPP 1955 Moss Court, Kelowna Dates of Tests: June 04-06, 2001 B.C. Canada V1Y 9L3 FCC Part 22 Certification © 2001 Celltech Research Inc. SSENTECH CO., LTD. FCC ID: PPPCWH-100 Single-Mode CDMA Cellular Phone (824-849MHz) INTERNAL EUT PHOTOGRAPHS CELLTECH RESEARCH INC. Test Report S/N: 052501-119PPP 1955 Moss Court, Kelowna Dates of Tests: June 04-06, 2001 B.C. Canada V1Y 9L3 FCC Part 22 Certification © 2001 Celltech Research Inc. SSENTECH CO., LTD. FCC ID: PPPCWH-100 Single-Mode CDMA Cellular Phone (824-849MHz) INTERNAL EUT PHOTOGRAPHS CELLTECH RESEARCH INC. Test Report S/N: 052501-119PPP 1955 Moss Court, Kelowna Dates of Tests: June 04-06, 2001 B.C. Canada V1Y 9L3 FCC Part 22 Certification © 2001 Celltech Research Inc. SSENTECH CO., LTD. FCC ID: PPPCWH-100 Single-Mode CDMA Cellular Phone (824-849MHz) INTERNAL EUT PHOTOGRAPHS CELLTECH RESEARCH INC. Test Report S/N: 052501-119PPP 1955 Moss Court, Kelowna Dates of Tests: June 04-06, 2001 B.C. Canada V1Y 9L3 FCC Part 22 Certification © 2001 Celltech Research Inc. SSENTECH CO., LTD. FCC ID: PPPCWH-100 Single-Mode CDMA Cellular Phone (824-849MHz) INTERNAL EUT PHOTOGRAPHS
FCC RF EXPOSURE INFORMATION In August 1996 the Federal Communications Commission (FCC) of the United States with its action in Report and Order FCC 96-326 adopted an updated safety standard for human exposure to radio frequency (RF) electromagnetic energy emitted by FCC regulated transmitters. Those guidelines are consistent with the safety standard previously set by both U.S. and international standards bodies. The design of this phone complies with the FCC guidelines and these international standards. Use only the supplied or an approved antenna. Unauthorized antennas, modifications, or attachments could impair call quality, damage the phone, or result in violation of FCC regulations. Do not use the phone with a damaged antenna. If a damaged antenna comes into contact with the skin, a minor burn may result. Please contact your local dealer for replacement antenna. Body-worn Operation This device was tested for typical body-worn operations using the Ssentech CWH-100 belt-holster. To comply with FCC RF exposure requirements, use only Ssentech approved accessories. When carrying the phone with the power on, use only the specific Ssentech belt-holster that has been tested for compliance. The use of non Ssentech approved accessories may not comply with FCC RF exposure requirements and should be avoided. For more information about RF exposure, please visit the FCC website at www.fcc.gov Read this information before using your handset
CELLTECH RESEARCH INC. Test Report S/N: 052501-120PPP 1955 Moss Court, Kelowna Date(s) of Tests: June 01-04, 2001 B.C. Canada V1Y 9L3 FCC SAR Measurements _________________________________________________________________________________________________________ © 2001 Celltech Research Inc. CERTIFICATE OF COMPLIANCE SAR EVALUATION This wireless portable device has been shown to be compliant for localized Specific Absorption Rate (SAR) for uncontrolled environment/general exposure limits specified in ANSI/IEEE Std. C95.1-1992 and has been tested in accordance with the measurement procedures specified in ANSI/IEEE Std. C95.3-1999. I attest to the accuracy of data. All measurements were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. Celltech Research Inc. certifies that no party to this application has been denied FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Shawn McMillen General Manager Celltech Research Inc. Test Lab: CELLTECH RESEARCH INC. Testing and Engineering Lab 1955 Moss Court Kelowna, B.C. Canada V1Y 9L3 Phone: 250 - 860-3130 Fax: 250 - 860-3110 Toll Free: 1-877-545-6287 e-mail: [email protected] web site: www.celtechlabs.com Applicant Information: SSENTECH CO., LTD. 14F. Daegak Bldg., 1319-5 Seocho-dong, Seocho-gu, Seoul, Korea Contact: David Kim, Manager Mobile Communication R&D Lab FCC ID: PPPCWH-100 Model(s): CWH-100 Equipment Type: Single-Mode CDMA Cellular Phone Classification: Licensed Non-Broadcast Transmitter Held to Ear (TNE) Tx Frequency Range: 824.70 - 848.31 MHz Rx Frequency Range: 869.70 - 893.31 MHz Max. RF Output Power: 0.251 Watts (ERP) FCC Rule Part(s): 2.1093; ET Docket 96.326 CELLTECH RESEARCH INC. Test Report S/N: 052501-120PPP 1955 Moss Court, Kelowna Date(s) of Tests: June 01-04, 2001 B.C. Canada V1Y 9L3 FCC SAR Measurements _________________________________________________________________________________________________________ © 2001 Celltech Research Inc. TABLE OF CONTENTS 1.0 INTRODUCTION.................................................................. 1 2.0 DESCRIPTION OF EUT.......................................................... 1 3.0 SAR MEASUREMENT SYSTEM ............................................. 2 4.0 MEASUREMENT SUMMARY.................................................. 3-5 5.0 SAR LIMITS........................................................................ 6 6.0 DETAILS OF SAR EVALUATION........................................... 6 7.0 EVALUATION PROCEDURES................................................. 7 8.0 SYSTEM VALIDATION.......................................................... 7 9.0 SIMULATED EQUIVALENT TISSUES...................................... 8 10.0 TISSUE PARAMETERS......................................................... 8 11.0 SYSTEM SPECIFICATIONS.................................................... 9 12.0 TEST EQUIPMENT LIST........................................................ 10 13.0 MEASUREMENT UNCERTAINTIES........................................ 11 14.0 REFERENCES...................................................................... 12 APPENDIX A - SAR MEASUREMENT DATA........................................ 13 APPENDIX B - DIPOLE VALIDATION................................................ 14 APPENDIX C - PROBE CALIBRATION............................................... 15 APPENDIX D - SAR TEST SETUP PHOTOGRAPHS.............................. 16 CELLTECH RESEARCH INC. Test Report S/N: 052501-120PPP 1955 Moss Court, Kelowna Date(s) of Tests: June 01-04, 2001 B.C. Canada V1Y 9L3 FCC SAR Measurements _________________________________________________________________________________________________________ © 2001 Celltech Research Inc. SSENTECH CO., LTD. FCC ID: PPPCWH-100 1 Single-Mode CDMA Cellular Phone (824.70-848.31MHz) 1.0 INTRODUCTION This measurement report shows compliance of the SSENTECH CO., LTD. Model: CWH-100 Single-Mode CDMA Cellular Phone FCC ID: PPPCWH-100 with FCC Part 2.1093, ET Docket 96-326 Rules for mobile and portable devices. The test procedures, as described in American National Standards Institute C95.1-1992 (1), FCC OET Bulletin 65-1997 were employed. A description of the product and operating configuration, detailed summary of the test results, methodology and procedures used in the evaluation, equipment used, and the various provisions of the rules are included within this test report. 2.0 DESCRIPTION of Equipment Under Test (EUT) EUT Type Single-Mode CDMA Cellular Phone FCC ID PPPCWH-100 Equipment Class Licensed Non-Broadcast Transmitter Held to Ear (TNE) Model No.(s) CWH-100 FCC Rule Part(s) § 2.1093, Docket 96-326 Application Type Part 22 Certification Tx Frequency Range (MHz) 824.70 - 848.31 S/N No. Pre-production Rx Frequency Range (MHz) 869.70 - 893.31 Max. RF Output Power 0.251 Watts (ERP) Modulation CDMA Battery Type(s) Slim: 3.7V Lithium Polymer Standard: 3.7V Lithium Ion Antenna Type Retractable Whip Antenna Length 91 mm Front of EUT Left Side of EUT Right Side of EUT Back of EUT Antenna Belt-Holster CELLTECH RESEARCH INC. Test Report S/N: 052501-120PPP 1955 Moss Court, Kelowna Date(s) of Tests: June 01-04, 2001 B.C. Canada V1Y 9L3 FCC SAR Measurements _________________________________________________________________________________________________________ © 2001 Celltech Research Inc. SSENTECH CO., LTD. FCC ID: PPPCWH-100 2 Single-Mode CDMA Cellular Phone (824.70-848.31MHz) 3.0 SAR MEASUREMENT SYSTEM Celltech Research SAR measurement facility utilizes the Dosimetric Assessment System (DASY™) manufactured by Schmid & Partner Engineering AG (SPEAG™) of Zurich, Switzerland. The DASY system is comprised of the robot controller, computer, near-field probe, probe alignment sensor, and the generic twin phantom containing brain or muscle equivalent mat…
Text truncated - open the document above for the full version.
Ssentech Co., Ltd. FCC ID: PPPCWH-100 Generic Twin Phantom; Flat Section; Position: (270°,270°) Probe: ET3DV6 - SN1387; ConvF(6.43,6.43,6.43); Crest factor: 1.0 Muscle 835 MHz: σ = 0.95 mho/m ε r = 56.1 ρ = 1.00 g/cm 3 Coarse: Dx = 20.0, Dy = 20.0, Dz = 10.0; Cube 5x5x7 SAR (10g): 1.39 mW/g Hand SAR Ssentech Model: CWH-100 CDMA Mode - Antenna Out Channel 363 [835.89 MHz] Conducted Power: 24.8 dBm Date Tested: June 4, 2001 SAR Tot [mW/g] 1.55E-1 5.34E-1 9.14E-1 1.55E+0 1.92E+0 Celltech Research Inc. Celltech Research Inc. Ssentech Co., Ltd. FCC ID: PPPCWH-100 Generic Twin Phantom; Flat Section; Position: (270°,270°) Probe: ET3DV6 - SN1387; ConvF(6.43,6.43,6.43); Crest factor: 1.0 Muscle 835 MHz: σ = 0.95 mho/m ε r = 56.1 ρ = 1.00 g/cm 3 Coarse: Dx = 20.0, Dy = 20.0, Dz = 10.0; Cube 5x5x7 SAR (10g): 1.25 mW/g Hand SAR - Extended Battery Ssentech Model: CWH-100 CDMA Mode - Antenna Out Channel 363 [835.89 MHz] Conducted Power: 24.8 dBm Date Tested: June 4, 2001 SAR Tot [mW/g] 1.41E-1 5.20E-1 9.00E-1 1.41E+0 1.78E+0 Celltech Research Inc. Celltech Research Inc. CELLTECH RESEARCH INC. Test Report S/N: 052501-120PPP 1955 Moss Court, Kelowna Date(s) of Tests: June 01-04, 2001 B.C. Canada V1Y 9L3 FCC SAR Measurements _________________________________________________________________________________________________________ © 2001 Celltech Research Inc. SSENTECH CO., LTD. FCC ID: PPPCWH-100 14 Single-Mode CDMA Cellular Phone (824.70-848.31MHz) APPENDIX B - DIPOLE VALIDATION Dipole 835 MHz Generic Twin Phantom; Flat Section; Position: (90°,90°); Probe: ET3DV6 - SN1387; ConvF(6.43,6.43,6.43); Crest factor: 1.0; Brain 835 MHz: σ = 0.80 mho/m ε r = 44.2 ρ = 1.00 g/cm 3 Coarse: Dx = 20.0, Dy = 20.0, Dz = 10.0 Cube 5x5x7 SAR (1g): 2.04 mW/g, SAR (10g): 1.35 mW/g Validation Date: June 1, 2001 SAR Tot [mW/g] 2.17E-1 6.49E-1 1.09E+0 1.52E+0 1.95E+0 Celltech Research Inc. Celltech Research Inc. Dipole 835 MHz Generic Twin Phantom; Flat Section; Position: (90°,90°); Probe: ET3DV6 - SN1387; ConvF(6.43,6.43,6.43); Crest factor: 1.0; Brain 835 MHz: σ = 0.80 mho/m ε r = 44.2 ρ = 1.00 g/cm 3 Coarse: Dx = 20.0, Dy = 20.0, Dz = 10.0 Cube 5x5x7 SAR (1g): 2.02 mW/g, SAR (10g): 1.34 mW/g Validation Date: June 4, 2001 SAR Tot [mW/g] 2.15E-1 6.47E-1 1.07E+0 1.50E+0 1.93E+0 Celltech Research Inc. Celltech Research Inc. Validation Dipole D835V2 SN:411, d = 15mm Frequency: 835 MHz; Antenna Input Power: 250 [mW] Generic Twin Phantom; Flat Section; Grid Spacing: Dx = 20.0, Dy = 20.0, Dz = 10.0 Probe: ET3DV5 - SN1342/DAE3; ConvF(5.75,5.75,5.75); Brain 835 MHz: σ = 0.80 mho/m ε r = 44.2 ρ = 1.00 g/cm 3 Cubes (2): Peak: 3.07 mW/g ± 0.05 dB, SAR (1g): 2.06 mW/g ± 0.05 dB, SAR (10g): 1.38 mW/g ± 0.05 dB, (Worst-case extrapolation) Penetration depth: 13.6 (12.7, 14.8) [mm] Powerdrift: -0.00 dB SAR Tot [mW/g] 2.50E-1 5.00E-1 7.50E-1 1.00E+0 1.25E+0 1.50E+0 1.75E+0 2.00E+0 2.25E+0 2.50E+0 Validation SN411, 08/26/99 Schmid & Partner Engineering AG, Zurich Switzerland CELLTECH RESEARCH INC. Test Report S/N: 052501-120PPP 1955 Moss Court, Kelowna Date(s) of Tests: June 01-04, 2001 B.C. Canada V1Y 9L3 FCC SAR Measurements _________________________________________________________________________________________________________ © 2001 Celltech Research Inc. SSENTECH CO., LTD. FCC ID: PPPCWH-100 15 Single-Mode CDMA Cellular Phone (824.70-848.31MHz) APPENDIX C - PROBE CALIBRATION Probe ET3DV6 SN:1387 Manufactured:September 21, 1999 Last calibration:September 22, 1999 Calibrated for System DASY3 Page 1 of 7 ET3DV6 SN:1387 DASY3 - Parameters of Probe: ET3DV6 SN:1387 Sensitivity in Free SpaceDiode Compression NormX1.55 μV/(V/m) 2 DCP X98mV NormY1.65 μV/(V/m) 2 DCP Y98mV NormZ1.64 μV/(V/m) 2 DCP Z98mV Sensitivity in Tissue Simulating Liquid Brain450MHz ε r =48 ± 5% σ = 0.50 ± 10% mho/m ConvF X6.76 extrapolatedBoundary effect: ConvF Y6.76 extrapolatedAlpha0.30 ConvF Z6.76 extrapolatedDepth2.52 Brain900MHz ε r =42.5 ± 5% σ = 0.86 ± 10% mho/m ConvF X6.34 ± 7% (k=2)Boundary effect: ConvF Y6.34 ± 7% (k=2)Alpha0.47 ConvF Z6.34 ± 7% (k=2)Depth2.25 Brain1500MHz ε r =41 ± 5% σ = 1.32 ± 10% mho/m ConvF X5.78 interpolatedBoundary effect: ConvF Y5.78 interpolatedAlpha0.69 ConvF Z5.78 interpolatedDepth1.88 Brain1800MHz ε r =41 ± 5% σ = 1.69 ± 10% mho/m ConvF X5.50 ± 7% (k=2)Boundary effect: ConvF Y5.50 ± 7% (k=2)Alpha0.81 ConvF Z5.50 ± 7% (k=2)Depth1.70 Sensor Offset Probe Tip to Sensor Center2.7mm Optical Surface Detection1.6 ± 0.2mm Page 2 of 7 ET3DV6 SN:1387 Receiving Pattern (φ), θ = 0° f = 30 MHz, TEM cell ifi110 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 XYZTot f = 100 MHz, TEM cell ifi110 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 XYZTot f = 300 MHz, TEM cell ifi110 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 XYZTot f = 900 MHz, TEM cell ifi110 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 XYZTot Page 3 of 7 ET3DV6 SN:1387 Isotropy Error (φ), θ = 0° -1.00 -0.80 -0.60 -0.40 -0.20 0.00 0.20 0.40 0.60 0.80 1.00 060120180240300360 error[dB] 30 MHz 100 MHz 300 MHz 900 MHz 1800 MHz 2500 MHz f = 1800 MHz, WG R22 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 XYZTot f = 2500 MHz, WG R26 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 XYZTot Page 4 of 7 ET3DV6 SN:1387 Frequency Response of E-Field ( TEM-Cell:ifi110, Waveguide R22, R26 ) 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 050010001500200025003000 f [MHz] frequency response TEMR22R26 Page 5 of 7 ET3DV6 SN:1387 Dynamic Range f(SAR brain ) ( TEM-Cell:ifi110 ) 1.E+0 1.E+1 1.E+2 1…
Text truncated - open the document above for the full version.
CELLTECH RESEARCH INC. Test Report S/N: 052501-119PPP 1955 Moss Court, Kelowna Dates of Tests: June 04-06, 2001 B.C. Canada V1Y 9L3 FCC Part 22 Certification ____________________________________________________________________________________________________________________ © 2001 Celltech Research Inc. CERTIFICATE OF COMPLIANCE FCC PART 22 CERTIFICATION This equipment has been shown to be capable of compliance with the applicable technical standards as indicated in the measurement report and was tested in accordance with the measurement procedures specified in §2.947. I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. Celltech Research Inc. certifies that no party to this application has been denied FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Shawn McMillen General Manager Celltech Research Inc. Test Lab: CELLTECH RESEARCH INC. Testing and Engineering Services 1955 Moss Court Kelowna, B.C. Canada V1Y 9L3 Phone: 250 - 860-3130 Fax: 250 - 860-3110 Toll Free: 1-877-545-6287 e-mail: [email protected] web site: www.celltechlabs.com Applicant Information: SSENTECH CO., LTD. 14F. Daegak Bldg., 1319-5 Seocho-dong Seocho-gu, Seoul, Korea Contact: David Kim, Manager Mobile Communication R&D Lab FCC Classification: Licensed Non-Broadcast Transmitter Held to Ear (TNE) FCC Rule Part(s): §22.901(d), §2 FCC ID: PPPCWH-100 Model(s): CWH-100 Equipment Type: Single-Mode CDMA Cellular Phone Tx Frequency Range: 824.70 - 848.31 MHz Rx Frequency Range: 869.70 - 893.31 MHz Max. RF Output Power: 0.251 Watts (ERP) Frequency Tolerance: 2.5 PPM Emission Designator: 1M25F9W CELLTECH RESEARCH INC. Test Report S/N: 052501-119PPP 1955 Moss Court, Kelowna Dates of Tests: June 04-06, 2001 B.C. Canada V1Y 9L3 FCC Part 22 Certification ____________________________________________________________________________________________________________ © 2001 Celltech Research Inc. TABLE OF CONTENTS 1.1 GENERAL INFORMATION 1 2.1 MEASUREMENT PROCEDURES 2 Occupied Bandwidth (2.1049) 2 Spurious Emissions at Antenna Terminal (2.1051) 2 Radiated Spurious & Harmonic Emissions (2.1053) 2 Frequency Stability/Temperature Variation (2.1055) 3 3.1 TEST DATA 4 Effective Radiated Power Output 4 Field Strength of Spurious Radiation 5-7 Frequency Stability 8-9 4.1 LIST OF TEST EQUIPMENT 10 5.1 CONCLUSION 11 ATTACHMENT A: COVER LETTER(S) ATTACHMENT B: ATTESTATION STATEMENT(S) ATTACHMENT C: TEST REPORT ATTACHMENT D: TEST PLOTS ATTACHMENT E: FCC ID LABEL & LOCATION ATTACHMENT F: TEST SETUP PHOTOGRAPHS ATTACHMENT G: EXTERNAL EUT PHOTOGRAPHS ATTACHMENT H: INTERNAL EUT PHOTOGRAPHS ATTACHMENT I: BLOCK DIAGRAM(S) ATTACHMENT J: CIRCUIT DIAGRAMS ATTACHMENT K: CIRCUIT DESCRIPTION ATTACHMENT L: PARTS LIST ATTACHMENT M: TUNE UP PROCEDURE ATTACHMENT N: ANTENNA SPECIFICATIONS ATTACHMENT O: OPERATIONAL DESCRIPTION ATTACHMENT P: USER’S MANUAL ATTACHMENT Q: SAR MEASUREMENT REPORT CELLTECH RESEARCH INC. Test Report S/N: 052501-119PPP 1955 Moss Court, Kelowna Dates of Tests: June 04-06, 2001 B.C. Canada V1Y 9L3 FCC Part 22 Certification ____________________________________________________________________________________________________________ © 2001 Celltech Research Inc. SSENTECH CO., LTD. FCC ID: PPPCWH-100 1 Single-Mode CDMA Cellular Phone (824-849MHz) APPLICANT: SSENTECH CO., LTD. 14F. Daegak Bldg., 1319-5 Seocho-dong Seocho-gu, Seoul, Korea Contact: David Kim - Manager, Mobile Communication R&D Lab MEASUREMENT REPORT - FCC PART 22.901(d) 1.1 SCOPE Measurement and determination of electromagnetic emissions (EME) from radio f…
Text truncated - open the document above for the full version.
1955 Moss Court · Kelowna, B.C. · Canada
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 22.901(d) | 824.7 MHz - 848.31 MHz | 251.00 mW | 1M25F9W | 2.5000000000 ppm |