MICROWAVE HOOD COMBINATION INSTALLATION INSTRUCTIONS This product is suitable for use above electric or gas cooking products up to and including 36" (91.4 cm) wide. See the “Installation Requirements” section for further notes. These installation instructions cover different models. The appearance of your particular model may differ slightly from the illustration in these installation instructions. Table of Contents MICROWAVE HOOD COMBINATION SAFETY W11359126B MICROWAVE HOOD COMBINATION SAFETY ............................1 INSTALLATION REQUIREMENTS .................................................2 Tools and Parts .............................................................................2 Location Requirements ................................................................2 Product Dimensions .....................................................................3 Electrical Requirements ...............................................................3 INSTALLATION INSTRUCTIONS ...................................................4 Wall Venting Installation Only .......................................................4 Install Damper Assembly (for wall venting only) ..........................4 Roof Venting Installation Only ......................................................4 Install Damper Assembly (for roof venting only) ..........................5 Locate Wall Stud(s) ......................................................................5 Prepare Upper Cabinet ................................................................7 Mark Rear Wall .............................................................................8 Drill Holes in Rear Wall .................................................................8 Attach Mounting Plate to Wall .....................................................9 Install the Microwave Oven ..........................................................9 Complete Installation .................................................................10 VENTING DESIGN SPECIFICATIONS .........................................11 ASSISTANCE ................................................................................12 Replacement Parts .....................................................................12 You can be killed or seriously injured if you don't immediately You can be killed or seriously injured if you don't follow All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed. Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.” These words mean: follow instructions. instructions. DANGER WARNING 2 INSTALLATION REQUIREMENTS Tools and Parts Tools needed Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. ■ Measuring tape ■ Pencil ■ Masking tape or thumbtacks ■ Scissors ■No. 3 Phillips screwdriver for 1/4 - 20 x 3" (7.6 cm) bolts ■ Drill ■ 3/16" (5 mm), 3/8" (9.5 mm), 5/8" (1.6 cm) drill bits ■ 3/4" (1.9 cm) hole saw ■ Diagonal wire cutting pliers ■ Stud finder ■ 7/16" (1.1 cm) socket wrench (or box wrench) for 1/4" x 2" (0.6 cm x 5.1 cm) lag screws ■ 1 1 ⁄ 2 " (3.8 cm) diam. hole drill bit for wood or metal cabinet ■ Keyhole saw ■ Caulking gun and weatherproof caulking compound ■ Duct tape Parts supplied For information on reordering, see the “Replacement Parts” section. NOTE: The hardware items listed here are for wood studs. For other types of wall structures, be sure to use appropriate fasteners. NOTE: Depending on model, grease filter and charcoal filter may be combined. Materials Needed Standard fittings for wall or roof venting. See the “Venting Design Specifications” section. Location Requirements IMPORTANT: Check the opening where the microwave oven will be installed. The location must provide: ■ Minimum installation dimensions. See the “Installation Dimensions” illustration. ■ Minimum one 2" x 4" (5.1 cm x 10.16 cm) wood wall stud and minimum 3/8" (9.5 mm) thickness drywall or plaster/lath within cabinet opening. ■ Support for weight of 150 lbs (68 kg) which includes microwave oven and items placed inside the microwave oven and upper cabinet. ■ Grounded electrical outlet inside upper cabinet. See the “Electrical Requirements” section. NOTE: Some cabinet and building materials are not designed to withstand the heat produced by the microwave oven for cooking. Check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate, or sustain other damages. Special Requirements For Wall Venting Installation Only: ■ Cutout must be free of any obstructions so that the vent fits properly and the damper blade opens freely and fully. For Roof Venting Installation Only: ■ If you are using a rectangular-to-round transition piece, the 3" (7.6 cm) clearance needs to exist above the microwave oven so that the damper blade can open freely and fully. See “Rectangular to Round Transition” illustration in the “Venting Design Specifications” section. A. 3/16 - 24 x 3" (7.6 cm) round-head bolts (2) B. 1/4 - 20 x 3" (7.6 cm) flat-head bolts (2) C. Washers (2) D. 3/16" (4.8 mm) toggle nuts (2) E. 1/4" x 2" (0.6 cm x 5.1 cm) lag screws (2) F. Sheet metal screws 5/32" x 5/16" (0.4 cm x 0.8 cm) (2) G. Power supply cord bushing (1) H. Damper assembly (for wall or ro venting) J. Exhaust vent cover (2) Not Shown: ■ Mounting plate (Located on the upper polyfoam) ■ Grease filters ■ Charcoal filters A B C DEF G H J 3 Installation Dimensions NOTE: The grounded 3 prong outlet must be inside the upper cabinet. See th…
Text truncated - open the document above for the full version.
WhirlpoolMicrowaveProductsDevelopmentLimited. Address:17thFl,EliteCentre,22HungToRd,KwunTong,HongKong Email:[email protected] Tel:+8675583811688 CFR47§2.911(d)(5)(i)AttestationLetter AttestationLetter Date:2026-3-23 FEDERALCOMMUNICATIONSCOMMISSIONS AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsCFR47§2.911(d)(5)(i)Filing FCCID:PR4TANGOLP55011X WhirlpoolMicrowaveProductsDevelopmentLimited.certifiesthattheequipmentforwhich authorizationissought,isnot“covered”equipmentprohibitedfromreceivinganequipment authorizationpursuanttosection2.903oftheFCCrules. Sincerely, Signature: PrintedName:BoboLin Title:ApprobationManager
Whirlpool Microwave Products Development Limited. Address: 17th Fl, Elite Centre,22 Hung To Rd,Kwun Tong, Hong Kong Email: [email protected] Tel: +8675583811688 CFR 47 §2.911 (d)(5)(ii) Attestation Letter Attestation Letter Date: 2026-3- 23 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(ii) Filing FCC ID: PR4TANGOLP55011X Whirlpool Microwave Products Development Limited. certifies that as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. We also certify that, as of the date of the filing of the application, the equipment does not utilize cyber-security or anti-virus software from Kaspersky Lab, Inc, or any of its successors and assignees, which is also on the “covered list”. Sincerely, Signature: Printed Name: Bobo Lin Title: Approbation Manager
U.S.AGENTLETTEROFATTESTATION Date:2026-3-23 FEDERALCOMMUNICATIONSCOMMISSION AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsCFR47§2.911(d)(7)Filing FCCID:PR4TANGOLP55011X WhirlpoolMicrowaveProductsDevelopmentLimited.certifiesthat,asofthedateofthe filingoftheapplication,WhirlpoolCorporationisourdesignatedU.S.agentforserviceof processfortheabovereferencedFCCID.WhirlpoolMicrowaveProductsDevelopment Limited.acceptstomaintainanagentfornolessthanoneyearafterthegranteehas terminatedallmarketingandimportationortheconclusionofanyCommission-related proceedinginvolvingtheequipment. WhirlpoolCorporationaccepts,asofthedateofthefilingoftheapplication,the obligationofthedesignatedU.S.agentforserviceofprocessfortheabovereferencedFCC ID. DesignatedU.S.AgentInformation: Name:WhirlpoolCorporation Address:2000M63NorthBentonHarbor,MI49022UnitedStates FRN:0011042405 Tel.:001(269)923-5068 Email:[email protected] Signedby(printedname):PaulFriis Signature: Applicant:WhirlpoolMicrowaveProductsDevelopmentLimited. Address:17thFl,EliteCentre,22HungToRd,KwunTong,HongKong FRN:0012635595 Tel:+8675583811688 Email:[email protected] Signedby(printedname):BoboLin Signature:
WhirlpoolMicrowaveProductsDevelopmentLimited. Address:17thFl,EliteCentre,22HungToRd,KwunTong,HongKong Email:[email protected] Tel:+8675583811688 QA-FR-170-B7/29/2014 FCCAuthorization Date:2026-3-23 FEDERALCOMMUNICATIONSCOMMISSIONS AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:AgentAuthorization Towhomitmayconcern: We,WhirlpoolMicrowaveProductsDevelopmentLimited.theundersigned,hereby authorizesBayAreaComplianceLaboratoriesCorp.(Shenzhen).toactonitsbehalfin allmattersrelatingtoapplicationforEquipmentauthorization,includingthesigningof alldocumentsrelatingtothesematters.AllactscarriedoutbyBayAreaCompliance LaboratoriesCorp.(Shenzhen)onourbehalfshallhavethesameeffectasourown action. We,theundersigned,herebycertifythatwearenotsubjecttoadenialoffederalbenefits, thatincludesFCCbenefits,pursuanttoSection5301oftheAnti-DrugAbuseActof1988, 21U.S.C.862. Thisauthorizationisvaliduntilfurtherwrittennoticefromtheapplicant. Sincerely, Signature: PrintedName:BoboLin Title:ApprobationManager
WhirlpoolMicrowaveProductsDevelopmentLimited. Address:17thFl,EliteCentre,22HungToRd,KwunTong,HongKong Email:[email protected] Tel:+8675583811688 QA-FR-171-A Date:2026-3-23 FCCConfidentialAuthorization FEDERALCOMMUNICATIONSCOMMISSIONS AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:ConfidentialityRequestregardingapplicationforcertificationof FCCID:PR4TANGOLP55011X InaccordancewithSections0.457and0.459oftheCommission’sRules, WhirlpoolMicrowaveProductsDevelopmentLimited.herebyrequestslong-term confidentialtreatmentofinformationaccompanyingthisapplicationasoutlinedbelow: BlockDiagram Schematics OperationDescription Theabovematerialscontainproprietaryandconfidentialinformationnotcustomarily releasedtothepublic.Thepublicdisclosureofthesematerialsprovidesunjustified benefitstoitscompetitorsinthemarket. SincerelyYours, Signature: PrintedName:BoboLin Title:ApprobationManager
Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601Q18435E-EM-EXP Page 1 of 4 EUT EXTERNAL PHOTOGRAPHS Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601Q18435E-EM-EXP Page 2 of 4 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601Q18435E-EM-EXP Page 3 of 4 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601Q18435E-EM-EXP Page 4 of 4
Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2601Q18435E-EM FCC ID LABEL AND LOCATION FCC ID Label FCC ID Label Location Information The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925)
Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601Q18435E-EM-INP Page 1 of 13 EUT INTERNAL PHOTOGRAPHS Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601Q18435E-EM-INP Page 2 of 13 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601Q18435E-EM-INP Page 3 of 13 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601Q18435E-EM-INP Page 4 of 13 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601Q18435E-EM-INP Page 5 of 13 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601Q18435E-EM-INP Page 6 of 13 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601Q18435E-EM-INP Page 7 of 13
Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601Q18435E-EM-INP Page 8 of 13 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601Q18435E-EM-INP Page 9 of 13 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601Q18435E-EM-INP Page 10 of 13 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601Q18435E-EM-INP Page 11 of 13 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601Q18435E-EM-INP Page 12 of 13 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601Q18435E-EM-INP Page 13 of 13
Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601Q18435E-EM-00 TR-EM-RF027 Page 10 of 32 Version 3.0 FCC §18.313, §1.1310, §2.1091- MAXIMUM PERMISSIBLE EXPOSURE Applicable Standard According to §1.1310, radio frequency devices shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. Calculation formula: Prediction of power density at the distance of the applicable MPE limit S = PG/4πR² = power density (in appropriate units, e.g. mW/cm2); P = power input to the antenna (in appropriate units, e.g., mW); G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain factor, is normally numeric gain; R = distance to the center of radiation of the antenna (appropriate units, e.g., cm); For simultaneously transmit system, the calculated power density should comply with: Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601Q18435E-EM-00 TR-EM-RF027 Page 11 of 32 Version 3.0 Measurement Environmental Conditions Temperature: 24.5 °C Relative Humidity: 46 % ATM Pressure: 101.4 kPa The testing was performed by Wing K Ji on 2026-03-07. Radiation leakage was measured in the as-received condition with the oven door closed using a microwave leakage meter. A 275ml water load was placed in the center of the oven and the oven was operated at maximum output power. There was no microwave leakage exceeding a power level of 0.2 mW/cm 2 observed at any point 5cm or more from the external surface of the oven. A maximum of 1.0mW/cm 2 is allowed in accordance with the applicable Federal Standards. Hence, microwave leakage in the as-received condition with the oven door closed was below the maximum allowed. Result: Complied.
Note: The information marked # is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Customer model name, addresses, names, trademarks etc. are included. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP or any agency of the U.S. Government. This report may contain data that are not covered by the NVLAP accreditation and are marked with an asterisk “▼”. Bay Area Compliance Laboratories Corp. (Shenzhen) 5F(B-West) , 6F, 7F, the 3rd Phase of Wan Li Industrial Building D, Shihua Rd, FuTian Free Trade Zone, Shenzhen, China Tel: +86-755-33320018 Fax: +86-755-33320008 www.baclcorp.com.cn TR-EM-RF027 Page 1 of 32 Version 3.0 TEST REPORT Applicant Name: Whirlpool Microwave Products Development Limited. Address: 17th Fl, Elite Centre,22 Hung To Rd,Kwun Tong, Hong Kong Report Number: 2601Q18435E-EM-00 FCC ID: PR4TANGOLP55011X Test Standard (s) FCC PART 18 Sample Description Product Type: Household microwave oven Model No.: WML55011 Multiple Model(s) No.: N/A Trade Mark: Whirlpool, KitchenAid Date Received: 2026/02/13 Issue Date: 2026/04/28 Test Result: Pass ▲ ▲ In the configuration tested, the EUT complied with the standards above. Prepared and Checked By: Approved By: Joson Xiao Moon Liu EMC Engineer EMC Supervisor Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601Q18435E-EM-00 TR-EM-RF027 Page 2 of 32 Version 3.0 TABLE OF CONTENTS DOCUMENT REVISION HISTORY ......................................................................................................................... 3 GENERAL INFORMATION ....................................................................................................................................... 4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 4 OBJECTIVE ................................................................................................................................................................... 4 MEASUREMENT UNCERTAINTY .................................................................................................................................... 4 TEST FACILITY ............................................................................................................................................................. 4 OPERATING CONDITION/TEST CONFIGURATION .......................................................................................... 5 DESCRIPTION OF TEST CONFIGURATION ...................................................................................................................... 5 EUT EXERCISE SOFTWARE .......................................................................................................................................... 5 SPECIAL ACCESSORIES ................................................................................................................................................. 5 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 5 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 5 EXTERNAL CABLE LIST AND DETAILS ......................................................................................................................... 5 CONFIGURATION OF TEST SETUP ................................................................................................................................. 5 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 6 SUMMARY OF TEST RESULT ................................................................................................................................. 7 TEST EQUIPMENT LIST ........................................................................................................................................... 8 FCC §18.313, §1.1310, §2.1091- MAXIMUM PERMISSIBLE EXPOSURE ......................................................... 10 APPLICABLE STANDARD ............................................................................................................................................ 10 MEASUREMENT .......................................................................................................................................................... 11 CONDUCTED EMISSIONS ...................................................................................................................................... 12 APPLICABLE STANDARD ............................................................................................................................................ 12 EUT SETUP ................................................................................................................................................................ 12 EMI TEST RECEIVER SETUP ....................................................................................................................................... 12 TEST PROCEDURE ...................................................................................................................................................... 13 TEST DATA .........................................................................................................................................................…
Text truncated - open the document above for the full version.
Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601Q18435E-EM-TSP Page 1 of 5 EXHIBIT D - TEST SETUP PHOTOGRAPHS Conducted Emissions Front View Conducted Emissions Side View Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601Q18435E-EM-TSP Page 2 of 5 Radiated Emissions Front View (9 kHz-30 MHz) Radiated Emissions Rear View (9 kHz-30 MHz) Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601Q18435E-EM-TSP Page 3 of 5 Radiated Emissions FrontView (30 MHz-1 GHz) Radiated Emissions Rear View (30 MHz-1 GHz) Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601Q18435E-EM-TSP Page 4 of 5 Radiated Emissions FrontView (1-18GHz) Radiated Emissions Rear View (1-18GHz) Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601Q18435E-EM-TSP Page 5 of 5 Radiated Emissions FrontView (18-25GHz) Radiated Emissions Rear View (18-25GHz)
2000 M63 North · Benton Harbor, Michigan, 49022 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 18 | 2.45 GHz - 2.45 GHz | - |

Household microwave oven
Equipment Class
8CC - Part 18 Consumer Device
Household microwave oven
Equipment Class
8CC - Part 18 Consumer Device
Household microwave oven
Equipment Class
8CC - Part 18 Consumer Device
Household microwave oven
Equipment Class
8CC - Part 18 Consumer Device
HOUSEHOLD MICROWAVE OVEN
Equipment Class
8CC - Part 18 Consumer Device