
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 3 Report Version 1 Reference No.: 120717N027-2 PHOTOGRAPHS OF THE EUT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 3 Report Version 1 Reference No.: 120717N027-2 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 3 Report Version 1 Reference No.: 120717N027-2
#83022,84113, 7.5” BTM RC Controller (49MHz TX) Receiver (49MHz RX), FCC ID: PWYJT49RX99009 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)this device may not cause harmful interference, and (2)this device must accept any interference received, including interference that may cause undesired operation. FCC ID: PWYJT49TX99009 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)this device may not cause harmful interference, and (2)this device must accept any interference received, including interference that may cause undesired operation. 40MM 20MM 30MM 12MM
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 3 Report Version 1 Reference No.: 120717N027-2 PHOTOGRAPHS OF THE EUT ANT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 3 Report Version 1 Reference No.: 120717N027-2 ANT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 3 Report Version 1 Reference No.: 120717N027-2
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 13 Report Version 1 Test Report No.: FC120717N027-2 TEST REPORT Applicant: Jada Toys Co., Ltd Address: Unit 318, 3/F, Tower A, New Mandarin Plaza, No.14 Science Museum Road, TST East, Kowloon, HK Factory or Supplier: Jada Toys Co., Ltd Address: Unit 318, 3/F, Tower A, New Mandarin Plaza, No.14 Science Museum Road, TST East, Kowloon, HK Product: 7.5” BTM RC Brand Name: N/A Model: 83022 Additional Models & Model Difference: See Section 2.1 Date of tests: July 18, 2012~ July 24, 2012 The submitted sample of the above equipment has been tested for according to the requirements of the following standards: FCC Part 15, Subpart B, Class B CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Glyn He Project Engineer / EMC Department Approved by Sam Tung Manager/ EMC Department Date: July 24, 2012 This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 13 Report Version 1 Test Report No.: FC120717N027-2 Table of Contents RELEASE CONTROL RECORD ................................................................................ 3 1 SUMMARY OF TEST RESULTS ..................................................................... 4 1.1 MEASUREMENT UNCERTAINTY ...................................................................4 2 GENERAL INFORMATION .............................................................................. 5 2.1 GENERAL DESCRIPTION OF EUT ................................................................5 2.2 DESCRIPTION OF TEST MODES ..................................................................5 2.3 DESCRIPTION OF SUPPORT UNITS ............................................................5 3 EMISSION TEST ............................................................................................. 6 3.1 RADIATED EMISSION MEASUREMENT........................................................6 3.1.1 LIMITS OF RADIATED EMISSION MEASUREMENT ..................................6 3.1.2 TEST INSTRUMENTS .................................................................................7 3.1.3 TEST PROCEDURE ....................................................................................8 3.1.4 DEVIATION FROM TEST STANDARD ........................................................8 3.1.5 TEST SETUP ...............................................................................................9 3.1.6 EUT OPERATING CONDITIONS .................................................................9 3.1.7 TEST RESULTS .........................................................................................10 4 PHOTOGRAPHS OF THE TEST CONFIGURATION .................................... 12 5 APPENDIX A – MODIFICATIONS RECORDERS FOR ENGINEERING CHANGES TO THE EUT BY THE LAB.......................................................... 13 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 13 Report Version 1 Test Report No.: FC120717N027-2 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED Original release N/A July 24, 2012 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 13 Report Version 1 Test Report No.: FC120717N027-2 1 SUMMARY OF TEST RESULTS The EUT has been tested according to the following specifications: APPLIED STANDARD: FCC Part 15, Subpart B Standard SectionTest Item ResultRemark 15.107 Conducted Emission Test N/A N/A 15.109 Radiated Emission Test (30MHz ~ 1GHz) PASS Meets Class B Limit Minimum passing margin is -3.19dB at 429.32MHz 1.1 MEASUREMENT UNCERTAINTY Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the EUT as specified in CISPR 16-4-2: This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2. MEASUREMENT FREQUENCY UNCERTAINTY Conducted emissions 150kHz ~ 30MHz+/-2.56 dB Radiated emissions 30MHz ~ 1GHz +/-3.58 dB Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 3…
Text truncated - open the document above for the full version.
1 Set-up for radiated emission test <Frequency Range 30MHz~1GHz>
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | 49.86 MHz - 49.86 MHz | - |

BTM 1/16 RC, FAST & FURIOUS 1/16 RC, Hollywood Rides 1/16 RC, PINK SLIP 1/16 RC, Hyper Charger 1/16 RC
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Disney Pixar RC Cars, R/C Lightning Mcqueen
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
11 inches Ghostbuster RC, Stay Puft Marshmallow Man RC
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
1/16 F1 McLaren RC
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Star Wars AT-AT Walker RC, Star Wars AT-RT Walker RC
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter