Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCC: Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
PHOENIX TEST-LAB GmbH Product Certification Kˆnigswinkel 10 D 32825 Blomberg To Whom It May Concern: Please be advised that Tyco Electronics Belgium EC N.V. authorizes Senton GmbH to act on our behalf for applications submitted to PHOENIX TEST-LAB GmbH (PTL). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse ACT of 1988, U.S.C.862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you for your attention to this matter.
Request for Confidentiality in accordance with 47 CFR 0.459 Date: 14 December 2005 PHOENIX TEST-LAB GmbH Kˆnigswinkel 10 D-32825 Blomberg Germany RE: Certification Application FCC ID: QB4-1417121 Please be advised that the following information is to be held confidential on behalf of Tyco Electronics Belgium EC N.V.: • Schematics • Parts Lists • Block Diagram • Technical Description The application contains technical information which Tyco Electronics Belgium EC N.V. deems to be trade secrets and proprietary. If made public, the information might be used to the disadvantage of the applicant in the market place. Thank you for your attention to this matter.
FCC ID: QB4-1417121 FCC ID: QB4-1417121 FCC ID: QB4-1417121 FCC ID: QB4-1417121 FCC ID: QB4-1417121 FCC ID: QB4-1417121 FCC ID: QB4-1417121
FCC ID: QB4-1417121
FCC ID: QB4-1417121 FCC ID: QB4-1417121
Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Note: The test data of this report is related only to the individual item which has been tested. This report shall not be reproduced except in full extent without the written approval of the testing laboratory. Test Report No. 55705-050075-2 (Edition 1) Page 1 of 26 Pages Straubing, April 5, 2005 T E S T - R E P O R T No. 55705-050075-2 (Edition 1) for BMW Immobilizer Inductive Transponder Reader for Immobilizer Applicant: Tyco Electronics EC NV Test Specifications: FCC Code of Federal Regulations, CFR 47, Part 15, Sections 15.205 and 15.209 Industry Canada Radio Standards Specification RSS-210 Issue 5, Sections 6.2.1 and 6.3 (Category I Equipment) Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55705-050075-2 (Edition 1) Page 2 of 26 Pages Table of Contents 1 Description of the Equipment Under Test (EUT) ........................................................ 3 2 Administrative Data..................................................................................................... 4 3 Identification of the Test Laboratory ........................................................................... 5 4 Summary .................................................................................................................... 6 5 Operation Mode and Configuration of EUT................................................................. 7 6 Measuring Methods .................................................................................................... 8 6.1 Radiated Emission Measurement 9 kHz to 30 MHz ............................................. 8 6.2 Radiated emission in Fully Anechoic Room ....................................................... 10 6.3 Radiated emission at Open Field Test Site ........................................................ 12 7 Photographs Taken During Testing .......................................................................... 13 8 Test Results .............................................................................................................. 16 8.1 Occupied Bandwidth........................................................................................... 17 8.2 Emission Bandwidth ........................................................................................... 20 8.3 Designation of Emissions ................................................................................... 21 8.4 Restricted bands of operation............................................................................. 22 8.5 Radiated Emission Measurement 9 kHz to 30 MHz .......................................... 23 8.6 Radiated Emission Measurement 30 MHz to 1 GHz ......................................... 24 9 Referenced Regulations ........................................................................................... 25 10 Charts taken during testing ....................................................................................... 26 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55705-050075-2 (Edition 1) Page 3 of 26 Pages 1 Description of the Equipment Under Test (EUT) General data of EUT Type designation 1 : BMW Immobilizer Parts 2 : 1 Serial number(s): EZ800L38 Manufacturer: Tyco Electronics EC NV Type of equipment: Inductive Transponder Reader for Immobilizer Version: as delivered FCC ID: QB4-1417121 Additional parts/accessories: --- Technical data of EUT Application frequency range: 119 ñ 127 kHz Frequency range: 119 ñ 127 kHz Operating frequency: 125 kHz Type of modulation: ASK Pulse train: Not Applicable Pulse width: Not Applicable Number of RF-channels: 1 Channel spacing: Wideband (Not Applicable) Designation of emissions 3 : 10K0A1D Type of antenna: Inductive Loop Coil Size/length of antenna: ÿ 40 mm Type of power supply: Battery supply Specifications for power supply: nominal voltage: 13.2 V minimum voltage: 10.8 V maximum voltage: 15.6 V 1 Type designation of the system if EUT consists of more than one part. 2 Type designations of the parts of the system, if applicable. 3 Also known as "Class of Emission". Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55705-050075-2 (Edition 1) Page 4 of 26 Pages 2 Administrative Data Application details Applicant (full address): Tyco Electronics EC NV Siemenslaan 14 B-8020 Oostkamp Belgium Contact person: Mr. William van Loenhout Contract identification: Order no. 2453336427 Receipt of EUT: February 14 th , 2005 Date(s) of test: April 5 th , 2005 Note(s): --- Report details Report number: 55705-050075-2 Edition: 1 Issue date: April 5, 2005 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55705-050075-2 (Edition 1) Page 5 of 26 Pages 3 Identification of the Test Laboratory Details of the Test Laboratory Company name: Senton GmbH EMI/EMC Test Center Address: Aeussere Fruehlingstrasse 45 D-94315 Straubing Germany Laboratory Accreditation: DAR-Registration No. DAT-P-171/94-02 FCC Test Site registration number 90926 Industry Canada Test site registration: IC 3050 Contact person: Mr. Johann Roidt Phone: (+49) (0)9421 5522-0 Fax: (+49) (0)9421 5522-99 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55705-050075-2 (Edition 1) Page 6 of 26 Pages 4 Summary Summary of test results The tested sample complies with the requirements set forth in the Code of Federal Regulations CFR 47, Part 15, Sections 15.205 and 15.209 of the Federal Communication Commission (FCC) and the Radio Standards Specification RSS-210 Issue 5, Sections 6.2.1 and 6.3 (Category I Equipment) of Industry Canada (IC). Personnel involved in this report Laboratory Manager: Mr. Johann Roidt Responsible for testing: Mr. Martin Steindl Responsible for test report: Mr. Martin Steindl Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55705-050075-2 (Edition 1) Page 7 of 26 Pages 5 Operation Mode and Configuration of EUT Operation Mod…
Text truncated - open the document above for the full version.
Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55705-050075-2 (Edition 1) Page 14 of 26 Pages Test setup for radiated emission measurement 9 kHz ñ 30 MHz Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55705-050075-2 (Edition 1) Page 15 of 26 Pages Test setup for radiated emission measurement (fully anechoic room)
Aeussere Fruehlingstrasse 45 · Straubing · Germany
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.125 MHz - 0.125 MHz | - |