FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Cardionet/
  3. QBI-1005

QBI-1005CardioNet Monitor

Cardionet
CardioNet Monitor - FCC ID QBI-1005 - Cardionet
Click to zoom

Application Details

Equipment Class
PCT - PCS Licensed Transmitter worn on body
Date of Grant
May 04, 2003
Application Purpose
Original Equipment
Date of Application
May 04, 2003
Equipment Note
CardioNet Monitor
Frequency Range
1851.25000000 - 1908.75000000
Company
Cardionet
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗

External Photos

↗
↗

ID Label/Location Info

↗
↗

Internal Photos

↗
↗

RF Exposure Info

↗

Schematics

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

HOME HEART MONITORING Patient Education Guide Contents i TABLE OF CONTENTS 1. INTRODUCTION...................................................................................... 1 How the CardioNet Service Works ............................................................ 2 The CardioNet Monitoring Kit ................................................................... 4 Who to Call for Help ................................................................................... 8 2. SETTING UP............................................................................................ 9 Connecting At Home ............................................................................... 10 Setting Up the Base .................................................................................. 11 Checking Battery Power........................................................................... 12 Staying in Range ........................................................................................ 12 Limitations of cell phone coverage ......................................................... 12 Wearing the CardioNet Sensor ................................................................ 14 Placement of Lead Wires and Pads ......................................................... 15 3. USING THE MONITOR .......................................................................... 17 Monitor On and Off .................................................................................. 18 Using the Touch Screen ............................................................................ 20 Recording a Symptom.............................................................................. 23 When You Are Without Cell Phone Coverage ....................................... 27 Changing Monitor Options...................................................................... 28 Checking Monitor Status.......................................................................... 30 Viewing the Cell Signal Status .................................................................. 32 Warnings and Alarms ................................................................................ 33 4. SENSOR CARE ....................................................................................... 35 Changing Electrode Pads......................................................................... 36 Placing the Leads and Pads .................................................................... 39 Showering or Bathing............................................................................... 40 Changing the Battery ................................................................................ 42 5. TROUBLE SHOOTING........................................................................... 43 Responding to Warnings and Alarms ..................................................... 44 Cautions..................................................................................................... 56 6. SPECIFICATIONS, COMPLIANCE AND SYMBOLS ................................ 59 ii Caution:Caution: Caution:Caution: Caution: Federal law restricts this device to sale by or on the order of a physician. CardioNet Patient Service Center 3701 Market Street, Philadelphia PA 19104 Copyright 2003 All rights reserved Model Number 1001 Document Number - 100526 !! !! ! Revision A !! !! ! March 2003 Introduction 1 INTRODUCTION We Help Find Answers The CardioNet Service monitors your heart rhythms continuously. This helps your doctor detect problems that occur infrequently, even while you sleep. CardioNet works with you and your physician. The CardioNet Service was developed to help doctors detect and treat heart problems that may not happen often enough to be found during a routine ECG in the physician’s office. CardioNet monitors heart rhythm continuously, while people go about their normal daily activities. We can help physicians detect problems that may occur infrequently, whether you feel them or not, even while you are sleeping. Our goal at CardioNet is to work as a team with patients and physicians to help people receive the best possible care. We are honored that we were chosen to serve you. 1 2 Introduction 1. Introduction HOW THE CARDIONET SERVICE WORKS When you’re using the CardioNet Service, you’ll wear a small, lightweight sensor. The sensor monitors each heartbeat and sends data to the portable CardioNet monitor. The CardioNet monitor can be tucked away in a pocket or purse. It sends wireless communications to the CardioNet Center automatically when it detects an event, or when you report an event using the touch screen on the monitor. Sensor with lead Wires Lightweight sensor monitors each heartbeat. CardioNet monitor sends your information to the CardioNet Center 1. Introduction Introduction 3 CardioNet Patient Service Center Monitors Heart Rhythms The CardioNet Patient Service Center operates 24 hours a day, seven days a week. At the Center, specially trained cardiac technicians analyze your heart rhythms and report results to your physician. Physician Reviews Results Your physician reviews the results, discusses results with you and prescribes or adjusts treatment. 4 Introduction 1. Introduction THE CARDIONET MONITORING KIT The CardioNet Monitoring Kit contains the supplies you will need while you are on the CardioNet Monitoring Service. If any items are missing or broken, or if you have any questions about how to use them, please call the CardioNet Patient Service Center at 1-866-426-4401. When service is ended, please return all the items to their labeled slots and send the kit back to the monitoring center, following the directions on the enclosed return address label. It is important to return the patient supply kit no later than the very next day. Other patients may need to use the equipment. YOUR SERVICE KIT CONTAINS 1.1. 1.1. 1. The CardioNet MonitorThe CardioNet Monitor The CardioNet MonitorThe CardioNet Monitor The CardioNet Mo…

Text truncated - open the document above for the full version.

Block Diagram

Block Diagram StrongARM SA1110 6 MByte Static RAM 64 MByte Fl ash ROM Storage Audi o Ampl ifier Microphone Ampl i f i er AT Mega 103L Mi crprocessor TRF 6900 900MHz T/Rvr POWER SUPPLY 1.55 Volts 3.3 Vol ts 3.8 Vol ts D/A Converter A/D Converter LCD Di spl ay 1/4 VGA Cradle Interface USB/RS232/ Charger GPS RCVR CDMA/ AMPS Modem 800/1900 MHz 3. 3 Vol ts to Al l Sections 1. 5 Volts to SA1110 Core 3.8 Vol ts to Modem 8 MByte Fl ash ROM Program 3 Seri al Port s USB Port CTS/ RTS (GPI O 7, 8) Keyboar d Part of Daughter Board Part of Daughter Board 6 GPIOs /CS3 /CS3 SPI Seri al Port 2 Seri al Port 3 Seri al Port 1 /CS2 /CS0 /CS1 LCD Dri ve Part of Daughter Boar d Connect i on t o LCD on Daughter Board

Cover Letter(s)

April 14, 2003 Federal Communications Commission Authorization and Standards Division 7435 Oakland Mills Rd. Columbia, M.D. 21046 Dear sir/madam: Re: Request for Confidentiality We hereby request that the documentation listed below, submitted with the application for certification, be withheld from public disclosure. This request is made under the provisions of Section 0.457(d) of the Commission’s Rules, and Section 552(b)(4) of the Freedom of Information Act. We cite trade secrets as the reason and purpose of the request. 1. SB555 Modem Schematics SB555SCH_S_3C.PDF 2. SB555 Bill of Materials SB555BOM_S_3C.PDF. 3. SB555 Detailed Circuit Description SB555DCD_S_3C.PDF 4. SB555 Block Diagram SB555BLK_S_3C.PDF 5. SB555 Tune Up Procedure.pdf Sincerely, Dattesh Kumar Senior Hardware Designer Sierra Wireless, Inc.

External Photos

External Photographs FCC ID: QBI-1005 External Photographs FCC ID: QBI-1005 External Photographs FCC ID: QBI-1005 External Photographs FCC ID: QBI-1005

ID Label/Location Info

THIS BLANK AREA IN BARCODE BOX WILL PRINT 39 BARCODE AND THE SERIAL NUMBERS SEQUENCE AS SPECIFIED ON THE P.O. FOR PART NUMBER 220-0024-01 Patent Nos. 15 Volts DC. 1.2 amps FCC ID N7NSB555 - (cdma modem) RF ISM band MHz Complies with FCC part 15 220-0024-01 FCC ID: QBI-1005 (monitor) FCC ID: QBI-1002 (transceiver) Li-Ion Battery CARDIONET MONITOR Warning: Read Patient Education Guide before use. Protect from water and other liquid Medical Equipment If found please call: CardioNet Inc. San Diego, CA 92101 For Patient questions please call: 866-426-4401 5,959,529: 6,225,901 902-928 100-0005-01 REVISIONS REV. DESCRIPTION DATE APPROVED THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CardioNet Inc. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CardioNet Inc IS PROHIBITED. PROPRIETARY AND CONFIDENTIAL NEXT ASSY USED ON APPLICATION DO NOT SCALE DRAWING FINISH MATERIAL DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL 1/32 ANGULAR: MACH1 BEND 1.5 TWO PLACE DECIMAL .01 THREE PLACE DECIMAL .005 DRAWN CHECKED ENG APPR. MFG APPR. Q.A. COMMENTS: DATE NAME A SIZE SCALE:1:1 DWG. NO. WEIGHT:SHEET 1 OF 1 ZONE 510 MARKET STREET SAN DIEGO CA 92101 TITLE: 220-0023-01 A ARTWORK, CDMA MONITOR REAR LABEL SEE NOTES PRODUCTION RELEASE PER ECO # SEE NOTES REV. 3/xx/03 G.K. G.K. J.G. G.K. 9/26/02 9/26/02 9/26/02 A

ID Label/Location Info

1.65±.03 2.67 1.33 2X .73 A A A C L C L 3 4 NOTES. UNLESS OTHERWISE SPECIFIED: 1. MATERIAL-GM NAMEPLATE POLYCARBONATE WITH REVERSE PRINTED POLYESTER: 0.015" THK. 2. LABEL TEXT AND ARTWORK SHOULD BE PER CURRENT REVISION OF ARTWORK. PART #220-0023-01 Rev. A 3. COLOR OF MATERIAL - GMN2 4. TEXT COLOR - BLACK R.04 30.0° DETAIL A SCALE 2 : 1 4.12±.03 .015 MAX SECTION A-A SCALE 3 : 2 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CardioNet Inc. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CardioNet Inc IS PROHIBITED. PROPRIETARY AND CONFIDENTIAL NEXT ASSY USED ON APPLICATION DO NOT SCALE DRAWING FINISH MATERIAL DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL 1/32 ANGULAR: MACH1 BEND 1.5 TWO PLACE DECIMAL .01 THREE PLACE DECIMAL .005 A SIZE SCALE:1:1 DWG. NO. WEIGHT: SHEET 1 OF 1 REV. 510 MARKET STREET SAN DIEGO CA 92101 TITLE: 220-0024-01 CDMA MONITOR LABEL SEE NOTES ZONE APPROVED DATE DESCRIPTION REV. REVISIONS J.G. 9/26/02 G.K. NAME DATE COMMENTS: Q.A. MFG APPR. ENG APPR. CHECKED DRAWN SEE NOTES G.K. 9/26/02 9/26/02 PRODUCTION RELEASE ECO#XXX 3/XX/03 G.K. A A

Internal Photos

Internal Photographs FCC ID: QBI-1005 Internal Photographs FCC ID: QBI-1005 Internal Photographs FCC ID: QBI-1005 Internal Photographs FCC ID: QBI-1005 Internal Photographs FCC ID: QBI-1005 Internal Photographs FCC ID: QBI-1005 Internal Photographs FCC ID: QBI-1005

RF Exposure Info

on the CardioNet ECG Monitor With Arrhythmia Detection Model Number: CardioNet Monitor FCC ID: QBI-I005 Test Report: 30388163 Date of Report: March 25,2003 Job#: 3038816 Date of Test: March 10 to 11,2003 A2LA Certificate Number: 1755-01 Tested by .~r ~ I Suresh Kondapal1i Wa"tOCk Hersey --- -i@. David Chernomordik, Ph.D., EMC Technical Manager ~ Review Date: ,,~..,,~ ..A. '\- .~ ~IP em: - :II' ,,;""" " , : ~ j ',,--,-~ Intertek Testing Services NA, Inc. lOr Cardionet, Inc. 1365 Adams Court, Menlo Park, CA 94025 Telephone 650-463-2900 Fax 650-463-2910 Home Page www.etlsemko.com 1365 Adams Court, Menlo Park, CA 94025 Cardionet, Inc., Model No: CardioNet Monitor Date of Test: March 10 to 11, 2003 FCC ID: QBI-1005 File: 30388163 Page 2 of 58 FCC Part 2 & RSS-102 SAR Evaluation TABLE OF CONTENTS STATEMENT OF COMPLIANCE .......................................................................................................... 3 1.0 JOB DESCRIPTION ..................................................................................................................... 4 1.1 Client Information.............................................................................................................. 4 1.2 Equipment under test (EUT) ............................................................................................... 4 1.3 Test Plan Reference ............................................................................................................5 1.4 System Test Configuration ................................................................................................. 6 1.4.1 System Block Diagram & Support Equipment ...................................................... 6 1.4.2 Test Position .......................................................................................................... 7 1.4.3 Test Condition ....................................................................................................... 8 1.5 Modifications required for compliance............................................................................... 8 1.6 Additions, deviations and exclusions from standards ......................................................... 8 2.0 SAR EVALUATION ..................................................................................................................... 9 2.1 SAR Limits ......................................................................................................................... 9 2.2 Configuration Photographs ............................................................................................... 10 2.3 System Verification .......................................................................................................... 16 2.4 Evaluation Procedures ...................................................................................................... 16 2.5 Test Results....................................................................................................................... 17 3.0 TEST EQUIPMENT.................................................................................................................... 20 3.1 Equipment List..................................................................................................................20 3.2 Muscle Tissue Simulating Liquid ..................................................................................... 22 3.3 E-Field Probe Calibration ................................................................................................. 23 3.4 Measurement Uncertainty ................................................................................................. 24 3.5 Measurement Tractability ................................................................................................. 25 4.0 WARNING LABEL INFORMATION - USA........................................................................... 26 5.0 REFERENCES............................................................................................................................. 27 6.0 DOCUMENT HISTORY ............................................................................................................ 28 APPENDIX A - SAR Evaluation Data .................................................................................................... 29 APPENDIX B - E-Field Probe Calibration Data ................................................................................... 45 APPENDIX C – Phantom Certificate ..................................................................................................... 58 1365 Adams Court, Menlo Park, CA 94025 Cardionet, Inc., Model No: CardioNet Monitor Date of Test: March 10 to 11, 2003 FCC ID: QBI-1005 File: 30388163 Page 3 of 58 FCC Part 2 & RSS-102 SAR Evaluation STATEMENT OF COMPLIANCE The Cardionet Monitor, FCC ID: QBI-1005 was evaluated for SAR in accordance with the requirements for RF Exposure compliance testing defined in FCC OET Bulletin 65, Supplement C (Edition 01-01). Testing was performed at the Intertek Testing Services facility in Menlo Park, California. For the evaluation, the dosimetric assessment system DASY3 was used. The phantom employed was the "SAM Twin Phantom". The total uncertainty for the evaluation of the spatial peak SAR values averaged over a cube of 1g tissue mass had been assessed for this system to be ±27.8%. The device was tested at their maximum output power declared by the Cardionet Inc. In summary, the maximum spatial peak SAR value for the sample device averaged over 1g was found to be: Phantom Position SAR 1g , mW/g Flat Section 1.5 cm from phantom 0.89 In conclusion, the tested sample device was found to be in compliance with the requirements defined in OET Bulletin 65, Supplement C (Edition 01-01) for body-worn configuration. 1365 Adams Court, Menlo Park, CA 94025 Cardionet, Inc., Model No: CardioNet Monitor Date of Test: March 10 to 11, 2003 FCC ID: QBI-1005 File: 30388163 Page 4 of 58 FCC Part 2 & RSS-1…

Text truncated - open the document above for the full version.

Schematics

55 44 33 22 11 D D C C B B A A 10- TXD_1 Diagnostic Interface 8- GPIO_8 Audio Amplifier DNI DNI DNI 7- /UDC Base/Charger Interface 20- Com6- RXD_117-Com Battery Pack Interface 13- Battery +19- RF Out Ear Piece Amplifier 15- Battery +5- Com18- Battery Com4- Com Volume Control 16- Therm 1/10Vcc 3- RS232/Modem (GPIO_26)14- SCL_Batt2- +1512- SDA_Batt 2 Pole 4KHz filter 1- +1511- GPIO_7 EL Panel Interface 9-UDC 9- UDC RTC + Located off board 190-3200-04 1 Monitor_V5_3_Audio Analog 110 Monday, March 17, 2003 TitleSize Document Number Rev Date: Sheet of JimSweeney Phil Cari ThermSDA_BattSCL_Batt Bob_R Mark_B /AudioOut_EBL Larry Battery_Pack_Plus Larry_W Augie Cornell Jim_L Gino JimG Data_Bus_5Data_Bus_0 ADR_Bus_3 Data_Bus_4 ADR_Bus_2 Data_Bus_3 ADR_Bus_5ADR_Bus_1ADR_Bus_4 Data_Bus_2Data_Bus_7Data_Bus_1Data_Bus_6 VCC_3_3 VCC_3_3 VCC_3_3 VCC_3_3 VCC_3_3 VCC_3_3 +15_V VCC_3_3 C64.001uF D26 MBR914 L168.7nH C3.1uF R1911.62K R207100K R179 0 R1921K LM4860 U1 LM4860M 1 4 8 9 16 1314 12 1015 11 67325 GND GND GND GND GND -IN+IN Vdd Vout1Vout2 GAIN-OUT HP-IN1HP-IN2HP-SenseShutdownBYPASS R193100K R7 0 C215pF R194 10K C191 .1uF C12.2uF R2 100 L18.7nH J3 Battery Conn. 123 L19FPB-1206-A601 U34 MAX394 1 2 3 4 56 7 8 9 1020 19 18 17 16 1514 13 12 11 IN1 NO1 COM1 NC1 V- GND NC2 COM2 NO2 IN2IN4 NO4 COM4 NC4 V+ N.C.NC3 COM3 NO3 IN3 C5 4.7uF R11 0 C42.2uF R8 0 D27 MBR914 J4 020-0085-01 135791113151719 2468 101214161820 ++++++++++ ++++++++++ R208100K R10 R10 0 C612.2uF C7.1uF R12 1K R190 0 TVS1SMDA05C 1 2 3 4 8 7 6 5 In1 In2 In3 In4 Com Com Com Com R1460 C62.001uF R4 2.7 Y5 32.768KHZ R168 10 Q12N7002/SOT23 3 1 2 R169 100 R5 2.7 R170100K C6 DNI R17120.5K R195 1K +- U31A LM358 32 1 84 R164 1K C182.01uF R182 100 R161 1K L18FPB-1206-A601 C8.1uF R162 2.67KR163 10K C9DNI R9100K R205100KR176100K C178.1uF J1 CLP-120-02-G-D 13579 111315171921232527293133353739 246810121416182022242628303234363840 C183.1uF R610K C184.15uF C180.01uF U39 DS1501WE 9 1014151617 21 234 7 1819202223242526 1312 61 27 85 11 28 X1X2A3A2A1A0 GND SQW KS VBAT VCC DQ0DQ1DQ2DQ3DQ4DQ5DQ6DQ7 A4IRQ WEOECE PWR VBaux RST GND +- U31B LM358 56 7 84 C1850.0082 R1831K BT1 BR1220/1HF R3 51.1K IO_Port_2IO_Port_1 TXD_1 Audio2_Out GPIO_3 DAC_OUT_+ GPIO_21 GPIO_7 SCL_Batt DAC_OUT_- Batt_Gnd IO_Port_3 TXD_1 GPIO_14 SPK1 GPIO_0 GPIO_14 GPIO_18GPIO_17 GPIO_7 GPIO_1 GPIO_4 GPIO_19 TXD_3 GPIO_6GPIO_9GPIO_10 RF_Out GPIO_20 GPIO_11 SDA_Batt GPIO_5GPIO_2 GPIO_15 EL_Control IO_Port_0 GPIO_13 GPIO_4 TXD_2 GPIO_6 Therm GPIO_27 GPIO_8 GPIO_16 GPIO_12 RXD_2GPIO_27 Audio1_Out RXD_3 UDC/UDC RXD_1 Audio3_Out Batt_Gnd GPIO_8 R_BATT GPIO_25GPIO_22 RXD_1 GPIO_24GPIO_23GPIO_26 GPIO_26 Data_Bus_[0..31] /WR_SA ADR_Bus_[0..25] /RD 3.0_Batt /CS_4 55 44 33 22 11 D D C C B B A A < Data to AVR from SA MISO /CS*/WR VCC_3.3 Power Off/ON Control To RF Section MOSI /Reset SCK Locate on PCB near center of board beneath LCD INT0 Temperature Sensor Com SS A-D Converter + /CS*//WR 190-3200-04 1 Monitor V5 AVR_Processor_I/O 210 Monday, March 17, 2003 TitleSize Document Number Rev Date: Sheet of Data_Bus_4 Data_Bus_7 Data_Bus_7 Gary Doreen Data_Bus_1 /SS Data_Bus_2 Data_Bus_3 Data_Bus_1 Data_Bus_3 Data_Bus_4 Data_Bus_0 Data_Bus_5 Data_Bus_8 SCK Data_Bus_9 Data_Bus_1 Data_Bus_2 MOSI A_D_CLK Data_Bus_7 audio_0 Data_Bus_2 audio_1 Data_Bus_5 Data_Bus_6 Data_Bus_6 Data_Bus_6 Doug_E Data_Bus_0 Data_Bus_0 Data_Bus_3 Data_Bus_5 MISO Data_Bus_4 Bob_G VCC_3_3 VCC_3_3 VCC_3_3 VCC_3_3 VCC_3_3 VCC_3_3 VCC_3_3 VCC_3_3 VCC_3_3 VCC_3_3 VCC_3_3 VCC_3_3 VCC_3_3 TLV1578 U5 TLV1578CDA 1234 29303132 1213141516171819202156722 28 27 118 23242625 9 10 CH0CH1CH2CH3CH4CH5CH6CH7 D0D1D2D3D4D5D6D7 A0/D8A1/D9 /CS /WR /RD /CSTART MUX_Out AIN INT/EOC CLK REFPREFmAVddAGND DGND DVdd R22 100 R147100K R171K R23 100 C13.1uF 0123EN 12 X/Y U6A 74HC139AFN 2 4 3 56 1 7 168 R161K Q2 2N7002/SOT23 3 1 2 R24 100 C176100pF R15 1K R25 100 C63 .1uF R141K R19 1K C17.01uF D20 MBR914 R20 1K U32 74HC374 347813141718111 2569 12151619 2010 D0D1D2D3D4D5D6D7 OC CLK Q0Q1Q2Q3Q4Q5Q6Q7 VCCGND C1732.2uF +C1847uF R291K U3D SN74LV125 12 11 13 out inonly only U2 ATmega103L-4AI 1011121314151617 35363738394041422526272829303132343343123456789 242320191851504948474645446160595857565554 62 63 64 52 21 53 22 PB0/SSPB1/SCKPB2/MOSIPB3/MISOPB4/OC0/PWM0PB5/OC1A/PWM1APB6/OC1B/PWM1BPB7/OC2/PWM2 PC0/A8PC1/A9 PC2/A10PC3/A11PC4/A12PC5/A13PC6/A14PC7/A15 PD0/INTO PD1/INT1PD2/INT2PD3/INT3 PD4/IC1 PD5 PD6/T1PD7/T2 RD WR ALE PEN PE0/RXD PE1/TXD PE2/AC+ PE3/AC- PE4/INT4PE5/INT5PE6/INT6PE7/INT7 XTAL1XTAL2RESET TOSC1TOSC2PA0/AD0PA1/AD1PA2/AD2PA3/AD3PA4/AD4PA5/AD5PA6/AD6PA7/AD7PF0/ADC0PF1/ADC1PF2/ADC2PF3/ADC3PF4/ADC4PF5/ADC5PF6/ADC6PF7/ADC7 AREF AGND AVCC VCC VCC GND GND R28 100 R172100KQ15 2N7002/SOT23 3 1 2 R153475K R152100K Q16 2N7002/SOT23 3 1 2 MAX5190 U4 MAX5190BEEG 1314151617181920 12 11 8 22 97 4231 2423 10 21 5 6 D0D1D2D3D4D5D6D7 DGND DGND CS DGND CLK PD AGNDOUTPOUTNCREFREF0REFR REN DVdd AVdd DACEN R1851.1K Q17 2N7002/SOT23 3 1 2 R167100K 1 of 8 Decode 01234567 124 & EN U7 74HC138D 645 168 123 151413121110 97 C15.1uF D1 LED R150 100K D2 LED Q11MMBT3904 3 1 2 Q13 MMBT3906 3 1 2 +C1647uF D3 LED D4 LED C20.1uF C14.1uF C186.1uF C1227pF R140 10 Q10 2N7002/SOT23 3 1 2 C1127pF C10100pF R21100K J5 53261-0890 1 2 3 4 5 6 7 8 R1480 D10 MBR914 D18 MBR914 R3010K R1580 R155 100K U3B SN74LV125 5 6 4 R165100K R26 1K R1860 U3C SN74LV125 9 8 10 R51 1K R27100 C19.1uF U3A SN74LV125 2 3 1 U29DS60 2 1 3 Vdd Vout GND Y14.000 MHz R149100K R151100K C17247uF R1351.1K C170.1uF R154 10K A_D_4A_D_5 A_D_5 IO_Port_4 DAC_OUT_- RXD_C /WR_SAIO_Port_3IO_Port_2/RD CLOCK TXD_C A_D_0 SCLK_C /CS_3 A_D_2 GPIO_2 RSSI_OUT IO_Port_6 ADR_Bus_1 IO_Port_1 A_D_6 LOCKDET Data_Bus_[0..31] GPIO_17 SFRM_C GPIO_3 TX_DATA ADR_Bus_4 AtoD_Ref AMP_OUT MODE RX_DATA IO_Port_5 GPIO_1 IO_Port_7 ADR_Bus_3 GPIO_15 GPIO_18 R_BATT A_D_3 STROBE A_D_7A_D_1 DAC_OUT_+ POWER_BUTTON Power_Off /STDBY ADR_Bus_0 ADR_Bus_2 DATA IO_Port_0 3.0_Batt AVR_P_MOSIAVR_P_MISOAVR_MISOAVR_MOSI SA_MISOSA_MOSI 55 44 33 22 11 D D C C B B A A DSR Shutdown Rqst YD DTR X…

Text truncated - open the document above for the full version.

Test Report

 2002 Sierra Wireless, Inc. This document contains information which is proprietary and confidential to Sierra Wireless, Inc. Disclosure to persons other than the officers, employees, agents, or subcontractors of the Company or licensee of this document without the prior written permission of Sierra Wireless, Inc. is strictly prohibited. FCC Part 22 and 24 800/1900 MHz CDMA DUAL BAND MODULE Model: SB555-S FCC ID: N7NSB555 Prepared by SIERRA WIRELESS INC. 13811 WIRELESS WAY RICHMOND, BC V6V 3A4 CANADA Test Date(s): September 2002 SIERRA WIRELESS, INC. FCC Part 22 & 24 Test Report SB555-S Sept 2002 Page 2 of 43 Table of Contents 1 Introduction and Purpose.........................................................................3 2 Test Summary..........................................................................................3 3 Product Description.................................................................................4 4 Test Configuration...................................................................................5 5 RF Power Output.....................................................................................6 5.1 Test Procedure....................................................................................................6 5.2 Test Equipment.................................................................................................... 6 5.3 Test Results.........................................................................................................7 6 Occupied Bandwidth..............................................................................14 6.1 Test Procedure..................................................................................................14 6.2 Test Equipment.................................................................................................. 14 6.3 Test Results.......................................................................................................14 7 Out of Band Emissions at Antenna Terminals......................................17 7.1 Test Procedure..................................................................................................17 7.2 Test Equipment.................................................................................................. 17 7.3 Test Results.......................................................................................................18 8 Frequency Stability vs Temperature......................................................40 8.1 Test Procedure..................................................................................................40 8.2 Test Equipment.................................................................................................. 40 8.3 Test Results.......................................................................................................41 9 Frequency Stability vs Voltage..............................................................42 9.1 Test Procedure..................................................................................................42 9.2 Test Equipment.................................................................................................. 43 9.3 Test Results.......................................................................................................43  2002 Sierra Wireless, Inc. The contents of this page are subject to the confidentiality information on page one. SIERRA WIRELESS, INC. FCC Part 22 & 24 Test Report SB555-S Sept 2002 Page 3 of 43 1 Introduction and Purpose This document provides the FCC test data for the SB555-S module. The tests included in this report are limited to all conducted tests required. Other radiated tests were performed at an external test facility. 2 Test Summary FCC RULE DESCRIPTION OF TEST RESULT PAGE 2.1046 RF Power Output Complies 6 2.1049 Occupied Bandwidth Complies 15 2.1051, 22.901(d) 22.917(f), 24.238(a) Out of Band Emissions at Antenna Terminals Mobile Emissions In Base Frequency Range Complies 18 2.1053 Field Strength of Spurious Radiation Complies See CCS Report 2.1055 Frequency Stability vs Temperature Complies 44 2.1055 Frequency Stability vs Voltage Complies 45 The tests described in this report were performed by Mr. Sean Hoare, under the supervision of Mr Ron Vanderhelm, P.Eng. at Sierra Wireless, Inc. 13811 Wireless Way Richmond, B.C. V6V 3A4 Canada  2002 Sierra Wireless, Inc. The contents of this page are subject to the confidentiality information on page one. SIERRA WIRELESS, INC. FCC Part 22 & 24 Test Report SB555-S Sept 2002 Page 4 of 43 3 Product Description The Sierra Wireless Inc. model SB555-S is a dual band CDMA embedded modem. EUT Type Cellular and PCS CDMA Embedded Modem Whether quantity(>1) production is planned [X] Yes [ ]No Standards CDMA2000 Types of Emission 1M25F9W RF Output Power 824-849 MHz: 23.5 dBm max 1850-1910 MHz: 23.5 dBm max In both bands, power is variable to –50 dBm. Frequency Range 824-849 MHz, 1850-1910 MHz  2002 Sierra Wireless, Inc. The contents of this page are subject to the confidentiality information on page one. SIERRA WIRELESS, INC. FCC Part 22 & 24 Test Report SB555-S Sept 2002 Page 5 of 43 4 Test Configuration Tests were performed on the radio module alone. For frequency stability versus temperature, testing the module requires a wider range of temperature at the higher extreme to account for the insulating and warming affects of the end-user device. We test up to 70 degrees C for the module alone rather than just 50 deg C for the module in the end user device. For the effect of variation of DC power supply on frequency stability, the DC supply to the module was varied to the extremes of its specified voltage range, 3.15 to 4.2 volts. Item # Description Model No. Serial No. 1 Module EUT SB555-S E0207135003503C  2002 Sierra Wireless, Inc. The contents of this page are subject to the confidentiality information on page one. SIERRA WIRELESS, INC. FCC Part 22 & 24 Test Report S…

Text truncated - open the document above for the full version.

Test Report

Intertek Testing Services ETL SEMKO TEST REPORT Report Number: 303882162 Project Number: 30388216 Report Date: March 16, 2003 Testing performed on the CardioNet ECG Monitor With Arrhythmia Detection Model: CardioNet Monitor FCC ID: QBI-l00S to FCC Parts 22 and 24 for Cardionet, Inc. Test Performed bv: Intertek Testing Services 1365 Adams Court Menlo Park, CA 94025 A2LA Certificate Number: 1755-01 Test Authorized bv: Cardionet, Inc. 510 Market Street San Diego, CA 92101 Wamock Hersey --- .i,"- Prepared by: ~t'4 ~II..D~ David Chernomordik, EMC Technical Manager Reviewed by: CJJ;/ -yr-y-" Ollie Mo~g, ~ Manager ","A'.""I- ',-, ~ ~@ Date: # Date: ~ em: .-i-, ""&""'[ \ , i , l,,-~=/) Intertek Testing Services NA, Inc. 1365 Adams Court, Menlo Park, CA 94025 Telephone 650-463-2900 Fax 650-463-2910 Home Page www.etlsemko.com 1365 Adams Court, Menlo Park, CA 94025 CardioNet, Inc., CardioNet Monitor Date of Test: February 19 to March 14, 2003 FCC ID: QBI-1005 Report # 30388162 2 FCC Part 22 & 24 TABLE OF CONTENTS 1.0 Introduction ...................................................................................................................3 1.1 Test Summary .................................................................................................................. 3 1.2 Product Description ......................................................................................................... 4 1.3 Test Configuration ........................................................................................................... 5 1.4 Related Submittal(s) Grants .............…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Kent Sayler(Quality/Regulatory VP)
[email protected]619 243 7560Fax: 619 243 7700

Technical Contact

Intertek Testing ServicesSuresh Kondapalli
(650) 463-2900

1365 Adams Court · Menlo Park, California · United States

Non-Technical Contact

Intertek Testing ServicesSuresh Kondapalli
[email protected](650) 463-2900

Test Firm

Intertek Testing Services NA Inc.Roland Gubisch
[email protected]978-635-8500Fax: 978-263-7086

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
224E1.85 GHz - 1.91 GHz148.00 mW1M25F9W2.5 ppm
Confidentiality
Long Term
Grant Notes
Power is ERP (830MHz) EIRP (1900MHz). The device was not evaluated for use in the head region. Users must be provided with installation instructions and operating conditions for satisfying RF exposure compliance. Worst case SAR(1g) values measured at 100% duty cycle: 835MHz 1.07mW/g 1850MHz 0.132mW/g Transmitter must not be co-located or operating in conjuction with any other transmitter. Only accessories that have no metallic components maybe used.

Other Applications from Cardionet

Ambulatory Cardiac Outpatient Telemetry - FCC ID QBI-1012 - Cardionet
QBI-1012

Ambulatory Cardiac Outpatient Telemetry

Nov 08, 2010

Equipment Class

DTS - Digital Transmission System
Wireless Modem - FCC ID QBI-1010 - Cardionet
QBI-1010

Wireless Modem

Mar 28, 2007

Equipment Class

DTS - Digital Transmission System
C3 Sensor - FCC ID QBI-1008 - Cardionet
QBI-1008

C3 Sensor

Dec 26, 2006

Equipment Class

DTS - Digital Transmission System
C3 monitor - FCC ID QBI-1009 - Cardionet
QBI-1009

C3 monitor

Dec 21, 2006

Equipment Class

DTS - Digital Transmission System
Monitor - FCC ID QBI-1006 - Cardionet
QBI-1006

Monitor

Feb 08, 2004

Equipment Class