QBKETD-2740CowTek HealthWatch system

CowTek, Inc.
CowTek HealthWatch system - FCC ID QBKETD-2740 - CowTek, Inc.
Click to zoom

Application Details

Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Date of Grant
Oct 23, 2002
Application Purpose
Original Equipment
Date of Application
Oct 23, 2002
Equipment Note
CowTek HealthWatch system
Frequency Range
417.95000000 - 417.95000000
Company
CowTek, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Part I: The CowTek HealthWatch System Overview The CowTek HealthWatch system uses an electronic ETD BOLUS (Elevated Temperature Detection bolus) to monitor cattle for infections or illnesses which cause loss in weight gain or milk production. The ETD BOLUS consists of a weighted capsule which rests in the animal’s rumen and incorporates temperature monitoring and recording circuitry together with a radio-frequency transmitter to report changes in internal temperature which may indicate illness or infection. In addition to simple long- term health monitoring, the HealthWatch system also offers special veterinary monitoring and fertility detection modes. Note: fertility detection is presently in development and is not offered as a reliable indicator. This feature is included, however, because it is being used in laboratory settings for further research. Also, because cattle are less thermally stable than some species and because their normal internal temperatures can vary with seasonal, climatic and regional conditions, the ETD BOLUS accepts threshold reporting levels which can be set either using the Desktop Exciter prior to implanting the bolus. Hardware Components: To manage and monitor report transmissions from the boluses and to control operational modes, in addition to the temperature boluses, the HealthWatch system includes three types of external device: a Desktop Exciter to initialize boluses and a Field Receiver to monitor cattle over a wide area. Temperature Bolus The ETD BOLUS is an active, battery-powered temperature monitoring device which records and tracks temperature changes. The bolus is designed to ignore minor temperature fluxuations caused by diet or exertion while reporting prolonged elevated temperatures which are indications of illnesses or infections which demand attention and treatment. Figure 1: The CowTek HealthWatch Temperature Bolus The ETD BOLUS is sealed in an inert polypropylene capsule and weighted to prevent the bolus from being expelled from the rumen or from being passed through the digestive system. Powered by a sealed lithium battery, the ETD BOLUS has a functional lifespan – without attention – of approximately five years. Because a cow’s normal temperature can vary according to the temperature of their environment, the ETD BOLUS monitors and calculates a ‘normal reference’ temperature for each animal, adjusting this reference temperature according to seasonal and climatic changes. In addition to long-term health monitoring, the ETD BOLUS can also be used for veterinarian monitoring to report reactions to injections, implants or other treatments and can be used for ovulation monitoring (in development) to report when an animal is ready for artificial (or natural) insemination following the use of fertility stimulants. NOTICE TO THE USER Any changes or modifications not expressly approved by CowTek, Inc for compliance could void your authority to use the equipment. FCC WARNING This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Desktop Exciter The Desktop Exciter is used to ‘turn on’ a pill before it is given to the cow or bull. Because of FCC requirements for active transmitter devices and to ensure maximum battery life (estimated ~5 years), the HeathWatch temperature pills are shipped in a QUIET or OFF mode and must be initialized before use. The Desktop Exciter – see Figure 2 – has a recessed grove on the top shaped to the orientation of the pill; three mode buttons labeled WAKEUP, FERTILITY and VETERINARY and three threshold buttons labeled WINTER, NORMAL and SUMMER. In addition there are two LEDs – one RED and one GREEN – which show operation and status; one serial port (DB9, RS232, not shown); and a power connection (not shown). Figure 2: The Desktop Exciter Components The Desktop Exciter includes a 12-volt power supply (120VAC to12VDC) and a serial cable for connections to a desktop computer. Field Receiver The Field Receiver consists of a control box and a pole-mounted antenna and is used to monitor and record messages transmitted by HealthWatch temperature pills in cattle over a wide area. The Field Receiver control panel does not provide switches to select operational modes or change temperature thresholds. Figure 4: The Field Receiver Control and Antenna The number and locations of Field Receivers necessary are determined by the area to be covered including such factors as the number of cattle, and the size and location of the pens or other enclosures being monitored. The Field Receiver control box has one LED pair (RED/GREEN) to report status information (see LED Indicators) and a set of four serial connectors, one power connection and one RF connector (see Ports and Connections). Note: the two DB9 connectors on the front of the Receiver control box (one male, one female) and the two DB9 connectors on the bottom (one male, one female) are all connected as a single serial port. The two types and two positions simply provide convenient connections for either a handheld (PDA) device or a desktop or laptop computer. Components The Field Receiver includes a 12-volt power supply (120VAC to 12VDC) and a coaxial cable (control panel to antenna unit). Optional components include: • PDA (handheld) to DB9 serial cable – required for handheld versions of HealthWatch Monitor and Commander programs. • DB9 Serial cable (M/F) – required for desktop/laptop connection to run HealthWatch Monitor and Commander programs. LED Indicators The Field Receiver has one LED pair (one red, one green) on the control box. Functionally, the LEDs are used for error and status reporting as: Error / Status Reporting LED Display Meaning Duration GREEN slow blink reports waiting for download until data is dumped to handheld / desktop or u…

Text truncated - open the document above for the full version.

Block Diagram

Exhibit F – Block Diagrams CowTek, Inc. Temperature Bolus

Cover Letter(s)

28110 Avenue Stanford, Unit C Valencia, CA 91355 Phone: 661.295.9530 Fax: 661.295.9534 October 1, 2002 American Telecommunications Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 RE: Certification Application FCC ID: QBKETD-2740 Please be advised that the following information is to be held confidential and behalf of CowTek, Inc. We have applied for patents on the unit and as of today they have not been issued: • Wake-up circuit • Operation algorithm The application contains technical information, which CowTek, Inc. deems to be trade secrets and proprietary. If made public, the information might be used to the disadvantage of the applicant in the market place. Thank you for your attention to this matter. Sincerely, Gary F. Marsh President

Cover Letter(s)

American Telecommunications Certification Body Inc. 6731 Whittier Ave, McLean, VA 22101 October 15, 2002 RE: FCC ID: QBK ETD-2740 Attention: Jeffrey Lenk, Nicole Golden I have a few comments on this Application. 1 The label information does not specify what the label is made of and how it is attached to the device. Please provide this information. xxx 2 Please note that unless the ckt boards are ‘potted’ or otherwise prevented for being accessed or viewed by the user at the time of purchase, the internal photos cannot be held confidential. The board will be provided as not confidential unless it can be shown how this board will be potted and prevented from being exposed to view. xxx 3 You show the final transmitter section but have not provided any input as to the modulation circuitry used in the device. Please provide schematics of the entire transmitter device including the modulation circuitry. xxx 4 Please provide a theory of operation or a technical description of how the device operates. This is necessary to determine if the device falls into the requested part 15 section. xxx 5 Your manual states, “Any changes or modifications not expressly approved by CowTek, Inc for compliance could void your authority to modify the equipment.” This is a misleading statement and does not present the intent of the FCC non-modification statement of 15.21. The statement is to notify users that unauthorized modification of the device may void the authority to use the device, not that it voids the authority to modify the equipment. Please correct the statement to reflect the intent of the FCC non-modification statement. xxx 6 The report does not indicate if the device was tested in the three orthogonal axis. Please provide data or an explanation as to testing all three orthogonal planes, xxx 7 The documentation does not appear to specify that the device meets the 15.231e rules pertaining to automatic limiting of transmission. 15.231 states, “In addition, devices operated under the provisions of this paragraph shall be provided with a means for automatically limiting operation so that the duration of each transmission shall not be greater than one second and the silent period between transmissions shall be at least 30 times the duration of the transmission but in no case less than 10 seconds.” Please provide evidence that the device meets this criteria. Dennis Ward mailto:[email protected] The items indicated above must be submitted before processing can continue on the above referenced application. Failure to provide the requested information may result in application termination. Correspondence should be considered part of the permanent submission and may be viewed from the Internet after a Grant of Equipment Authorization is issued. Please do not respond to this correspondence using the email reply button. In order for your response to be processed expeditiously, you must submit your documents through the AmericanTCB.com website. Also, please note that partial responses increase processing time and should not be submitted. Any questions about the content of this correspondence should be directed to the sender. American Telecommunications Certification Body Inc. 6731 Whittier Ave, McLean, VA 22101 October 18, 2002 RE: FCC ID: QBK ETD-2740 Attention: Jeffrey Lenk, Nicole Golden I have a few comments on this Application. 1 See item 7 form ATCB comments of 10-15-02. The theory of operation states that data is sent to the transmitter, “in a 1-5 second Three pulse (anti-collision) output. Please note that 15.231e states, “In addition, devices operated under the provisions of this paragraph shall be provided with a means for automatically limiting operation so that the duration of each transmission shall not be greater than one second and the silent period between transmissions shall be at least 30 times the duration of the transmission but in no case less than 10 seconds.” The description in the theory of operation would seem to violate this one second limit to transmission as well as disagree with the test criteria in the report.. Please explain. xxx 2 You have not addressed the modification issue of item 5 from the ATCB comments of 10-15- 02. Please address this issue and clarify the intent of the required FCC non-modification statement. xxx Dennis Ward mailto:[email protected] The items indicated above must be submitted before processing can continue on the above referenced application. Failure to provide the requested information may result in application termination. Correspondence should be considered part of the permanent submission and may be viewed from the Internet after a Grant of Equipment Authorization is issued. Please do not respond to this correspondence using the email reply button. In order for your response to be processed expeditiously, you must submit your documents through the AmericanTCB.com website. Also, please note that partial responses increase processing time and should not be submitted. Any questions about the content of this correspondence should be directed to the sender.

Cover Letter(s)

Exhibit J- Letter of Authorization and Anti- Drug CowTek, Inc. Temperature Bolus

External Photos

CowTek, Inc. Temperature Bolus External – Top View External – Bottom View

ID Label/Location Info

Exhibit C – Equipment ID Labels and Locations CowTek, Inc. Temperature Bolus The FCC ID label will be etched in to the cap so to the fact that the product is going into an animal FCC ID # placement

Internal Photos

Exhibit E – EUT Photographs CowTek, Inc. Temperature Bolus CowTek, Inc. Temperature Bolus External – Top View External – Bottom View CowTek, Inc. Temperature Bolus Internal View Main Board View

Test Report

Professional Testing (EMI), Inc. Page 1 Project Number: 03137-10 Prepared for: COWTEK, INC. 28110 Avenue Stanford Unit C. Valencia, CA 91335 By Professional Testing (EMI), Inc. 1601 FM 1460, Suite B Round Rock, Texas 78664 October 2002 CERTIFICATION Electromagnetic Interference Test Report COWTEK, INC. Temperature Bolus (Intentional Radiator Portion) Professional Testing (EMI), Inc. Page 2 Table of Contents Title Page....................................................................................................................................1 Table of Contents........................................................................................................................2 Certificate of Compliance...........................................................................................................3 1.0 EUT Description.............................................................................................................2 1.1 EUT Operation................................................................................................................2 2.0 Electromagnetic Emissions Testing.................................................................................2 2.2 TEST CRITERIA.............................................................................................................3 2.3 TEST RESULTS..............................................................................................................3 3.0 Occupied Bandwidth Measurements................................................................................4 3.1 TEST PROCEDURE.........................................................................................................4 3.2 TEST CRITERIA.............................................................................................................4 3.3 TEST RESULTS..............................................................................................................4 4.0 Antenna Requirement......................................................................................................4 4.1 EVALUATION PROCEDURE............................................................................................5 5.3 EVALUATION RESULTS.................................................................................................5 6.0 Modifications to Equipment............................................................................................5 7.0 List of Test Equipment....................................................................................................5 Figures Figure 1: Radiated Emissions Test Setup.....................................................................................8 Appendices Appendix A: Fundamental Emissions Test Data..........................................................................9 Appendix B: Harmonic Emissions Test Data.............................................................................11 Appendix C: Occupied Bandwidth Test Data............................................................................15 Professional Testing (EMI), Inc. Page 3 THIS REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL, WITHOUT THE WRITTEN APPROVAL OF PROFESSIONAL TESTING (EMI), INC. 1601 FM 1460, Suite B Round Rock, Texas 78664 512/244-3371 Fax 512/244-1846 Applicant: CowTek, Inc. Applicant’s Address: 28110 Avenue Stanford Unit C Valencia, CA 91335 Model: Temperature Bolus Serial Number: None Project Number: 03137-10 I, Jeffrey A. Lenk, for Professional Testing (EMI), Inc., being familiar with the FCC rules and test procedures have reviewed the test setup, measured data and this report. I believe them to be true and accurate. The CowTek, Inc. Temperature Bolus was tested to and found to be in compliance with FCC Part 15 Subpart C, 15.231 (e) for an Intentional Radiator. The highest emissions generated by the above equipment are listed below: Frequency (MHz) Level (dBμV/m) Limit (dBμV/m) Margin (dB) Fundamental 417.95 50.3 72.3 -22.0 Harmonic 835.95 32.8 52.3 -19.5 Frequency (MHz) Bandwidth Limit (MHz) Bandwidth Measured (kHz) Occupied Bandwidth 417.95 1.045 74 ______________________________ Jeffrey A. Lenk President This report has been reviewed and accepted by CowTek, Inc.. The undersigned is responsible for ensuring that the Temperature Bolus will continue to comply with the FCC rules. ______________________________ Certificate of Compliance Professional Testing (EMI), Inc. Page 2 1.0 EUT Description The Equipment Under Test (EUT) is the CowTek, Inc. Temperature Bolus. The Temperature Bolus is an active, battery-powered temperature-monitoring device which records and tracks temperature changes in cattle. The bolus is designed to ignore minor temperature fluxuations caused by diet or exertion while reporting prolonged elevated temperatures, which are indications of illnesses or infections, which demand attention and treatment. The EUT operates at 418 MHz and is designed for compliance with 47 CFR 15.231(e) of the FCC rules. Specific test requirements for this device include the following: 47 CFR 15.231(e) Fundamental Transmit Power 47 CFR 15.231(e) & 15.205 Spurious Radiated Power 47 CFR 15.109 Unintentional Radiated Emissions 47 CFR 15.231(e) & 2.1049 Occupied Bandwidth (2.989 used as Procedural Reference) 47 CFR 15.203 Antenna Requirement The system tested consisted of the following: Manufacturer & Model Serial # FCC ID # Description CowTek, Inc., Temperature Bolus None QBKETD-2740 Temperature Bolus 1.1 EUT Operation The Temperature Bolus was placed in a special test mode, causing it to transmit every three seconds with a three burst transmission per each three-second period. The EUT was placed in the center of a plastic five-gallon water bottle, which was filled with water containing 1/3 grass, ½ cup vinegar, ½ cup salt. Setup and operational modes cover worst-case configuration and operational modes for the device. The frequency of the transmitting signal is 418 MHz. 2.0 Electromagne…

Text truncated - open the document above for the full version.

Test Report

1601 FM 1460, Suite B Round Rock, Texas 78664 512/244-3371 Fax 512/244-1846 Project Number: 03137-10 Prepared for: COWTEK, INC. 28110 Avenue Stanford Unit C. Valencia, CA 91335 By Professional Testing (EMI), Inc. 1601 FM 1460, Suite B Round Rock, Texas 78664 October 2002 CERTIFICATION Electromagnetic Interference Test Report COWTEK, INC. Temperature Bolus (Intentional Radiator Portion) Professional Testing (EMI), Inc. Page 2 Table of Contents Title Page....................................................................................................................................1 Table of Contents........................................................................................................................2 Certificate of Compliance...........................................................................................................3 1.0 EUT Description.............................................................................................................4 1.1 EUT Operation................................................................................................................4 2.0 Electromagnetic Emissions Testing.................................................................................4 2.2 TEST CRITERIA.............................................................................................................5 2.3 TEST RESULTS..............................................................................................................5 3.0 Occupied Bandwidth Measurements................................................................................6 3.1 TEST PROCEDURE.........................................................................................................6 3.2 TEST CRITERIA.............................................................................................................6 3.3 TEST RESULTS..............................................................................................................6 4.0 Antenna Requirement......................................................................................................6 4.1 EVALUATION PROCEDURE............................................................................................7 5.3 EVALUATION RESULTS.................................................................................................7 6.0 Modifications to Equipment............................................................................................7 7.0 List of Test Equipment....................................................................................................7 Figures Figure 1: Radiated Emissions Test Setup.....................................................................................8 Appendices Appendix A: Fundamental Emissions Test Data..........................................................................9 Appendix B: Harmonic Emissions Test Data.............................................................................11 Appendix C: Occupied Bandwidth Test Data............................................................................15 THIS REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL, WITHOUT THE WRITTEN APPROVAL OF PROFESSIONAL TESTING (EMI), INC. Professional Testing (EMI), Inc. Page 3 Applicant: CowTek, Inc. Applicant’s Address: 28110 Avenue Stanford Unit C Valencia, CA 91335 Model: Temperature Bolus Serial Number: None Project Number: 03137-10 I, Jeffrey A. Lenk, for Professional Testing (EMI), Inc., being familiar with the FCC rules and test procedures have reviewed the test setup, measured data and this report. I believe them to be true and accurate. The CowTek, Inc. Temperature Bolus was tested to and found to be in compliance with FCC Part 15 Subpart C, 15.231 (e) for an Intentional Radiator. The highest emissions generated by the above equipment are listed below: Frequency (MHz) Level (dBμV/m) Limit (dBμV/m) Margin (dB) Fundamental 417.95 50.3 72.3 -22.0 Harmonic 835.95 32.8 52.3 -19.5 Frequency (MHz) Bandwidth Limit (MHz) Bandwidth Measured (kHz) Occupied Bandwidth 417.95 1.045 74 ______________________________ Jeffrey A. Lenk President This report has been reviewed and accepted by CowTek, Inc.. The undersigned is responsible for ensuring that the Temperature Bolus will continue to comply with the FCC rules. ______________________________ Certificate of Compliance Professional Testing (EMI), Inc. Page 4 1.0 EUT Description The Equipment Under Test (EUT) is the CowTek, Inc. Temperature Bolus. The Temperature Bolus is an active, battery-powered temperature-monitoring device which records and tracks temperature changes in cattle. The bolus is designed to ignore minor temperature fluxuations caused by diet or exertion while reporting prolonged elevated temperatures, which are indications of illnesses or infections, which demand attention and treatment. The EUT operates at 418 MHz and is designed for compliance with 47 CFR 15.231(e) of the FCC rules. Specific test requirements for this device include the following: 47 CFR 15.231(e) Fundamental Transmit Power 47 CFR 15.231(e) & 15.205 Spurious Radiated Power 47 CFR 15.109 Unintentional Radiated Emissions 47 CFR 15.231(e) & 2.1049 Occupied Bandwidth (2.989 used as Procedural Reference) 47 CFR 15.203 Antenna Requirement The system tested consisted of the following: Manufacturer & Model Serial # FCC ID # Description CowTek, Inc., Temperature Bolus None QBKETD-2740 Temperature Bolus 1.1 EUT Operation The Temperature Bolus was placed in a special test mode, causing it to transmit every three seconds with a three burst transmission per each three-second period. The EUT was placed in the center of a plastic five-gallon water bottle, which was filled with water containing 1/3 grass, ½ cup vinegar, ½ cup salt. Setup and operational modes cover worst-case configuration and operational modes for the device. The frequency of the transmitting signal is 418 MHz. 2.0 Electromagnetic Emissions Testing Professional Testi…

Text truncated - open the document above for the full version.

Test Report

1601 FM 1460, Suite B Round Rock, Texas 78664 512/244-3371 Fax 512/244-1846 Project Number: 03137-10 Prepared for: COWTEK, INC. 28110 Avenue Stanford Unit C. Valencia, CA 91335 By Professional Testing (EMI), Inc. 1601 FM 1460, Suite B Round Rock, Texas 78664 October 2002 CERTIFICATION Electromagnetic Interference Test Report COWTEK, INC. Temperature Bolus (Intentional Radiator Portion) Professional Testing (EMI), Inc. Page 2 Table of Contents Title Page....................................................................................................................................1 Table of Contents........................................................................................................................2 Certificate of Compliance...........................................................................................................3 1.0 EUT Description.............................................................................................................4 1.1 EUT Operation................................................................................................................4 2.0 Electromagnetic Emissions Testing.................................................................................4 2.2 TEST CRITERIA.............................................................................................................5 2.3 TEST RESULTS..............................................................................................................5 3.0 Occupied Bandwidth Measurements................................................................................6 3.1 TEST PROCEDURE.........................................................................................................6 3.2 TEST CRITERIA.............................................................................................................6 3.3 TEST RESULTS..............................................................................................................6 4.0 Antenna Requirement......................................................................................................6 4.1 EVALUATION PROCEDURE............................................................................................7 5.3 EVALUATION RESULTS.................................................................................................7 6.0 Modifications to Equipment............................................................................................7 7.0 List of Test Equipment....................................................................................................7 Figures Figure 1: Radiated Emissions Test Setup.....................................................................................8 Appendices Appendix A: Fundamental Emissions Test Data..........................................................................9 Appendix B: Harmonic Emissions Test Data.............................................................................11 Appendix C: Occupied Bandwidth Test Data............................................................................15 THIS REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL, WITHOUT THE WRITTEN APPROVAL OF PROFESSIONAL TESTING (EMI), INC. Professional Testing (EMI), Inc. Page 3 Applicant: CowTek, Inc. Applicant’s Address: 28110 Avenue Stanford Unit C Valencia, CA 91335 Model: Temperature Bolus Serial Number: None Project Number: 03137-10 I, Jeffrey A. Lenk, for Professional Testing (EMI), Inc., being familiar with the FCC rules and test procedures have reviewed the test setup, measured data and this report. I believe them to be true and accurate. The CowTek, Inc. Temperature Bolus was tested to and found to be in compliance with FCC Part 15 Subpart C, 15.231 (e) for an Intentional Radiator. The highest emissions generated by the above equipment are listed below: Frequency (MHz) Level (dBμV/m) Limit (dBμV/m) Margin (dB) Fundamental 417.95 50.3 72.3 -22.0 Harmonic 835.95 32.8 52.3 -19.5 Frequency (MHz) Bandwidth Limit (MHz) Bandwidth Measured (kHz) Occupied Bandwidth 417.95 1.045 74 ______________________________ Jeffrey A. Lenk President This report has been reviewed and accepted by CowTek, Inc.. The undersigned is responsible for ensuring that the Temperature Bolus will continue to comply with the FCC rules. ______________________________ Certificate of Compliance Professional Testing (EMI), Inc. Page 4 1.0 EUT Description The Equipment Under Test (EUT) is the CowTek, Inc. Temperature Bolus. The Temperature Bolus is an active, battery-powered temperature-monitoring device which records and tracks temperature changes in cattle. The bolus is designed to ignore minor temperature fluxuations caused by diet or exertion while reporting prolonged elevated temperatures, which are indications of illnesses or infections, which demand attention and treatment. The EUT operates at 418 MHz and is designed for compliance with 47 CFR 15.231(e) of the FCC rules. Specific test requirements for this device include the following: 47 CFR 15.231(e) Fundamental Transmit Power 47 CFR 15.231(e) & 15.205 Spurious Radiated Power 47 CFR 15.109 Unintentional Radiated Emissions 47 CFR 15.231(e) & 2.1049 Occupied Bandwidth (2.989 used as Procedural Reference) 47 CFR 15.203 Antenna Requirement The system tested consisted of the following: Manufacturer & Model Serial # FCC ID # Description CowTek, Inc., Temperature Bolus None QBKETD-2740 Temperature Bolus 1.1 EUT Operation The Temperature Bolus was placed in a special test mod…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Rick A Sohns(Operations Manager)
[email protected]661-295-9530Fax: 661-295-9534

Technical Contact

Professional Testing (EMI), Inc.Jeffrey Lenk
[email protected]512-244-3371

1601 FM 1460 Suite B · Round Rock, Texas · United States

Non-Technical Contact

Professional Testing (EMI), Inc.Nicole Golden
[email protected]512-244-3371

Test Firm

Professional Testing (EMI), Inc.Jeff Link
[email protected]512-244-3371Fax: 512-244-1846

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231(e)417.95 MHz - 417.95 MHz-
Confidentiality
Long Term