Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
DYNETICS INCORPORATED GroundAware™ Reconfigurable Surveillance Sensor Installation, Operation, and User’s Manual GROUNDAWARE™ RECONFIGURABLE SURVEILLANCE SENSOR Installation, Operation, and User’s Manual  Dynetics, Inc. 1002 Explorer Blvd Huntsville, AL 35806 Phone 256.964.4000 Version/ Revision Document Change # Release Date Originator Reason for Change 1/3/17 Joel Simoneau and Mike Stokes Initial version of the Installation, Operation, and User’s Manual for the GroundAware RSS Table of Contents Important Safety Instructions ..................................................... 1 Safe Usage ..................................................................................... 1 General Description and Specifications ..................................... 3 ........................................................................................................ 4 Specifications .................................................................................. 4 Installation .................................................................................. 5 Operation .................................................................................... 7 Configuration ................................................................................... 7 User Access .................................................................................... 7 User’s Guide ............................................................................... 7 GROUNDAWARE 1 Important Safety Instructions ARNING! Do no remove any part of the product enclosure or create an opening in the produce enclosure in any way. Risk of fatal electrical shock exists with any exposure to the internal product components. Further, any opening of modification of the enclosure by any non-Dynetics personnel voids the product warranty and can only be reinstated by Dynetics in writing. The GroundAware™ product should only be used with the power and data cables supplied with the unit by Dynetics. Failure to use provided cabling may result in damage to the unit and increased risk of electrical shock. Safe Usage Dynetics recommends that at least two people be used to move the unit. The unit should only be mounted by qualified personnel using the appropriate safety lanyards to prevent unrestrained unit fall should the mounting fail. The mounting fixture, power receptacle, and data receptacle used with the unit should be appropriately grounded by a qualified electrician. VERY IMPORTANT: GROUNDAWARE IS A RADIATING DEVICE WITH RF HAZARDS. INSTALLATION AND OPERATIONAL PROCEDURES MUST ENSURE THAT NO HUMANS OR ANIMALS PASS WITHIN ONE METER (1 m) OF THE UNIT WHILE IT IS POWERED. FCC COMPLIANCE STATEMENT CAUTION: Changes or modifications not expressly approved could void your authority to use this equipment Section 1 W 2 This device complies with Part 15 of the FCC Rules. Operation to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation 3 General Description and Specifications roundAware™ 360 is a user Reconfigurable Surveillance Sensor that detects, tracks, classifies, and provides actionable information relevant to objects within a 360° field of view up to One kilometers from the sensor. This capability is implemented via the interoperation of four sub-systems: The radar sub-system transmits S-band radio frequency signals, digitizes and processes the received returns, identifies detections, clusters detections to identify tracks, and associates tracks with feature data that can be used to classify the object. The radar can be configured to use three different waveforms, based on installed site, that will be explained in further detail in later sections. This manual should be used with radar sub- system model number 10037200. The server sub-system receives track data, receives and processes cla ssification data, hosts the GoogleMaps based user interface, and implements external sensor (e.g. single/dual band PTZ camera, unattended ground sensor, etc) integration. Server hosting of the user interface includes managing user-defined alert zones, per-zone alerting criteria, and the per-zone violation log. Commodity grade desktop or laptop computers may be used to execute the server sub-system software. The client sub-system renders the GoogleMaps user interface for each unique browser session. Users may maintain their own zoom and view settings, while sharing zone definitions, alert criteria, and camera control with other users. The user interface is browser agnostic, but works best with Mozilla Firefox. While the client software is executed on each user’s machine within a web browser, it is provided upon authentication and managed by the server sub-system software. The optional interface sub-system provides a cellular data link, optional use network interfaces, and independent radar power on/off control. The interface sub-system also includes the cabling, encoder, and power supplies required to integrate external cameras or other sensors. This sub-system is self-contained in an environmentally sealed enclosure with the external switches and connectors as required by the customer. GroundAware™ enables a customer to use the system in an environment where the interface is continually monitored by personnel on desktop or mobile devices, or in an unmonitored environment where personnel can be alerted to intrusions based on user defined criteria. Section 2 G 4 Figure 2-1 below illustrates how the GroundAware™ system and sub-systems interact and what is typically provided by Dynetics and by the user/reseller. NOTE: Optional integrated cameras and other sensors not shown. FIGURE 2-1 GroundAware™ System/Sub-System Block Diagram Specifications The GroundAware™ system is a sophisticated, multi-channel digital beam-forming device that utilizes state of the art Direct Digital Synthesis (DDS) waveform generation and …
Text truncated - open the document above for the full version.
Date: July 30, 2020 UL LLC 12 Laboratory Dr RTP, NC 27709, USA To whom it may concern: I, the undersigned, hereby authorize UL LLC to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by UL LLC on our behalf shall have the same effect as acts of our own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing UL LLC as our agent, we still recognize that we are responsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) do not use our product certification in such a manner as to bring UL LLC into disrepute and not make any statement regarding our product certification which UL LLC may consider misleading or unauthorized; e) upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by UL LLC; 2 f) use certification only to indicate the products are certified as being in conformity with specified standards; g) endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; h) ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of UL LLC; i) keep a record of all complaints made known to the us relating to the product’s compliance with requirements of the relevant standard and to make these records available to UL LLC when requested; j) take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; k) document the actions taken. This authorization is valid until further written notice from the applicant. Sincerely Yours, Paul E. Byrge II, Director of Contracts Dynetics, Inc. , A Leidos Company REMARK: 1. This authorization letter will be sent along with your application when filing with UL LLC. 2. Please follow the format and type it on company letterhead and send original to us. 3. Authorized signature must be in agreement with grantee code contact in FCC database. 3
Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 Subject: Request for Confidentiality FCC ID: QFS001-10064785 To Whom It May Concern: Pursuant to the provisions of Sections 0.457 and 0.459 of the Commission’s rules (47 CFR §§ 0.457, 0.459), we are requesting the Commission to withhold the following attachments as confidential document from public disclosure indefinitely. Schematic Diagram Block Diagram Theory of Operation Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Best Regards Paul E. Byrge II Director of Contracts Dynetics, Inc. , A Leidos Company 7-30-2020
GroundAware 3360 External Photographs Side View Top View Bottom View
.18 .50 .70 3.0 1.5 4X R.13 7. 8. 9. 11. NOTES: UNLESS OTHERWISE SPECIFIED APPLICABLE STANDARDS/SPECIFICATIONS:1. INTERPRET DRAWING IAW ASME Y14.100-2017. DIMENSIONING AND TOLERANCING IAW ASME Y14.5-2009. REMOVE ALL BURRS AND SHARP EDGES .010 MAX.2. MATERIAL: .020 THICK PHOTOSENSITIVE ALUMINUM PER MIL-DTL-15024F, TYPE H, STYLE IV.3. ATTACH 3M 468MP ADHESIVE TRANSFER TAPE TO BACK SIDE OF PLATE. DO NOT REMOVE TAPE LINER ON OPPOSITE SIDE.4. HUMAN READABLE INFORMATION IAW MIL-STD-130 AND PARAGRAPH 4.7. ALL TEXT TO BE ARIAL FONT TYPE.5. SERIAL NUMBER(S) TO BE PROVIDED AT TIME OF PURCHASE BY PROCURING ACTIVITY. 6. CHARACTERS ARE TO BE .08 INCH HIGH.7. CHARACTERS ARE TO BE .10 INCH HIGH, ARIAL NARROW. REPLACE XXXXXX WITH APPLICABLE SERIAL NUMBER. 8. CHARACTERS ARE TO BE .13 INCH HIGH.9. DATA MATRIX SYMBOL (2D BAR CODE) IAW MIL-STD-130 PARAGRAPHS 5.2.3.2 AND 5.2.7.2 FOR A SQUARE DATA MATRIX.10. 2D BAR CODE DATA ELEMENT INFORMATION (CONSTRUCT 2, DI)11. DATA ELEMENT 1: 7L855 DATA ELEMENT 2: 10064785 DATA ELEMENT 3: SERIAL NUMBER ARTWORK TO BE PROVIDED UPON REQUEST.12. SAMPLE MATRIX SHOWN FOR REFERENCE ONLY REVISION HISTORY ZONE REVDESCRIPTIONDATEAPPROVED -INITIAL RELEASESEE AGILESEE AGILE 1 D 34 C B A 1234 5678 D 567 C B A 10077246 SHEET of 0.00 LBS DAI D SCALE SIZE DWG. NO.REV. CALC MASS 4:1 7L855 - UNLESS OTHERWISE SPECIFIED DIM ARE IN INCHES TOL ON ANGLE .5° 1 PL .100 2 PL .030 3 PL .010 DO NOT SCALE DRAWING THIRD ANGLE PROJECTION 11 DWG NOSHREV 100772461- APPLICATION NEXT ASSYUSED ON S. WILSON 2019-12-10 2019-12-13 MODEL FILENAME: 10077246 REVISION: - DRAWING FILENAME: 10077246 MODEL LAST SAVED: Friday, December 13, 2019 8:11:24 AM B. BARTLETT APPROVED DRAWN DATE CONTRACT NO CHECKED FORMAT VERSION: 13 DYNETICS PROPRIETARY: THE DRAWING, SPECIFICATIONS AND/OR DESCRIPTIONS CONTAINED HEREIN, INCLUDING TECHNICAL DATA, ARE THE EXCLUSIVE PROPERTY OF DYNETICS. NO DISCLOSURE TO OTHERS EITHER IN THE UNITED STATES OR ABROAD IS PERMITTED WITHOUT THE EXPRESS WRITTEN AUTHORIZATION OF DYNETICS. FURTHERMORE, NO REPRODUCTION, MANUFACTURE, SALE OR USE OF ANY DEVICE, PROCESS, COMPOSITION OF MATTER OR PORTION OF INFORMATION DISCLOSED HEREIN, WHETHER PATENTED, COPYRIGHTED, OR TRADEMARKED OR NOT, SHALL BE MADE EXCEPT BY WRITTEN AUTHORIZATION OF DYNETICS. THIS IS NOT INTENDED AND SHALL NOT NULLIFY OR LIMIT ANY RIGHTS TO A PARTY OR THE GOVERNMENT GRANTED BY CONTRACT OR REQUIRED BY LAW OR REGULATION. PLACARD, IDENTIFICATION, GA3360, TAN DYNETICS STANDARD FORMAT HUNTSVILLE, ALABAMA 35806 WWW.DYNETICS.COM ALL SHEETS SAME REV SEE AGILE PLM FOR DETAILED APPROVAL INFORMATION. APPROVAL DISCIPLINES MAY BE LISTED BELOW (REFERENCE ONLY). TOP VIEW GRAPHITE THERMAL PAD INSTALLATION COMPONENTS HIDDEN FOR CLARITY 7 8 6 2 BOTTOM VIEW 18 3 3 1 D 34 C B A 1234 5678 D 567 C B A DWG NOSHREV 100647912 3 2 1:4 REVDWG. NO. SIZE SCALE: D DAI SHEET of 10064791 - 7L855 - MODEL FILENAME: 10064791 REVISION: - DRAWING FILENAME: 10064791 MODEL LAST SAVED: Wednesday, December 18, 2019 11:50:31 AM FORMAT VERSION: 13DYNETICS STANDARD CONT. FORMAT DYNETICS PROPRIETARY: THE DRAWING, SPECIFICATIONS AND/OR DESCRIPTIONS CONTAINED HEREIN, INCLUDING TECHNICAL DATA, ARE THE EXCLUSIVE PROPERTY OF DYNETICS. NO DISCLOSURE TO OTHERS EITHER IN THE UNITED STATES OR ABROAD IS PERMITTED WITHOUT THE EXPRESS WRITTEN AUTHORIZATION OF DYNETICS. FURTHERMORE, NO REPRODUCTION, MANUFACTURE, SALE OR USE OF ANY DEVICE, PROCESS, COMPOSITION OF MATTER OR PORTION OF INFORMATION DISCLOSED HEREIN, WHETHER PATENTED, COPYRIGHTED, OR TRADEMARKED OR NOT, SHALL BE MADE EXCEPT BY WRITTEN AUTHORIZATION OF DYNETICS. THIS IS NOT INTENDED AND SHALL NOT NULLIFY OR LIMIT ANY RIGHTS TO A PARTY OR THE GOVERNMENT GRANTED BY CONTRACT OR REQUIRED BY LAW OR REGULATION.
GroundAware 3360 Internal Photographs Company Proprietary Receive Antenna Array (Inside Top Lid) Central Enclosure Digital Radar Board: Top View Digital Radar Board: Bottom View
NVLAP LAB CODE 200246-0 FCC Part 1 Subpart I FCC Part 2 Subpart J RSS 102 ISSUE 5 RF EXPOSURE REPORT FOR GROUND RADAR MODEL NUMBER: GA3360 FCC ID: QFS001-10064785 REPORT NUMBER: R13255054-E2 ISSUE DATE: 2020-09-01 Prepared for DYNETICS 1002 EXPLORER BOULEVARD HUNTSVILLE, AL 35806 USA Prepared by UL LLC 12 LABORATORY DR. RESEARCH TRIANGLE PARK, NC 27709 USA TEL: (919) 549-1400 REPORT NO: R13255054-E2 DATE: 2020-09-01 FCC ID: QFS001-10064785 Page 2 of 8 UL LLC FORM NO: 03-EM-F00858 12 Laboratory Dr., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. REVISION HISTORY Ver. Issue Date Revisions Revised By 1 2020-06-01 Initial Issue Brian T. Kiewra 1 2020-09-01 Revised antenna gain. Brian T. Kiewra REPORT NO: R13255054-E2 DATE: 2020-09-01 FCC ID: QFS001-10064785 Page 3 of 8 UL LLC FORM NO: 03-EM-F00858 12 Laboratory Dr., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. TABLE OF CONTENTS REVISION HISTORY ..................................................................................................................2 TABLE OF CONTENTS .............................................................................................................3 1. ATTESTATION OF TEST RESULTS ..................................................................................4 2. TEST METHODOLOGY ......................................................................................................5 3. REFERENCES ....................................................................................................................5 4. FACILITIES AND ACCREDITATION ..................................................................................5 5. DEVICE UNDER TEST ........................................................................................................5 6. MAXIMUM PERMISSIBLE EXPOSURE (LIMITS AND EQUATIONS) ................................6 6.1. FCC RULES .................................................................................................................6 6.2. EQUATIONS .................................................................................................................7 7. RF EXPOSURE RESULTS ..................................................................................................8 END OF TEST REPORT ............................................................................................................8 REPORT NO: R13255054-E2 DATE: 2020-09-01 FCC ID: QFS001-10064785 Page 4 of 8 UL LLC FORM NO: 03-EM-F00858 12 Laboratory Dr., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. 1. ATTESTATION OF TEST RESULTS COMPANY NAME: Dynetics 1002 Explorer Boulevard Huntsville, AL 35806-2806 EUT DESCRIPTION: Ground Radar MODEL: GA3360 APPLICABLE STANDARDS STANDARD TEST RESULTS FCC PART 1 SUBPART I & PART 2 SUBPART J Complies UL LLC. tested the above equipment in accordance with the requirements set forth in the above standards. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. All samples tested were in good operating condition throughout the entire test program. Measurement Uncertainties are published for informational purposes only and were not taken into account unless noted otherwise. This document may not be altered or revised in any way unless done so by UL LLC. and all revisions are duly noted in the revisions section. Any alteration of this document not carried out by UL LLC. will constitute fraud and shall nullify the document. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. government. Approved & Released For UL LLC by: Prepared By: Jeffrey Moser Brian T. Kiewra Operations Leader Project Engineer UL – Consumer Technology Division UL – Consumer Technology Division REPORT NO: R13255054-E2 DATE: 2020-09-01 FCC ID: QFS001-10064785 Page 5 of 8 UL LLC FORM NO: 03-EM-F00858 12 Laboratory Dr., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. 2. TEST METHODOLOGY All calculations were made in accordance with FCC Parts 1.1310, 2.1091, KDB 447498 D01 v06, IEEE Std C95.1-2005, IEEE Std C95.3-2002. 3. REFERENCES Output power, duty cycle, and Antenna gain data is excerpted from the applicable documentation provided by manufacturer. 4. FACILITIES AND ACCREDITATION The test sites and measurement facilities used to collect data are located at 12 Laboratory Dr., Research Triangle Park, NC 27709, USA and 2800 Perimeter Park Dr., Suite B, Morrisville, NC 27560, USA. UL LLC (RTP) is accredited by NVLAP, Laboratory Code 200246-0. 5. DEVICE UNDER TEST The EUT is a wide-band ground radar used to monitor a specific area. Other details regarding the EUT are documented in the applicable test reports and product documentation. REPORT NO: R13255054-E2 DATE: 2020-09-01 FCC ID: QFS001-10064785 Page 6 of 8 UL LLC FORM NO: 03-EM-F00858 12 Laboratory Dr., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. 6. MAXIMUM PERMISSIBLE EXPOSURE (LIMITS AND EQUATIONS) 6.1. FCC RULES §1.1310 The criteria listed in Table 1 shall be used to evaluate the environmental impact of human exposure to radio-frequency (RF) radiation as specified in §1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of §2.1093 of this c…
Text truncated - open the document above for the full version.
TEST REPORT Report Number : R13255054-E1 Applicant : Dynetics 1002 Explorer Boulevard Huntsville, AL 35806 Model : GA3360 FCC ID : QFS001-10064785 EUT Description : Ground Radar Test Standard(s) : FCC CFR47 PART 90.103 Date of Issue: 2020-09-01 Prepared by: UL LLC 12 Laboratory Dr. Research Triangle Park, NC 27709 USA Tel: (919) 549-1400 REPORT NO: R13255054-E1 DATE: 2020-09-01 MODEL: GA3360 FCC ID: QFS001-10064785 Page 2 of 86 UL LLC FORM NO: 03-EM-F00858 12 Laboratory Dr., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. REVISION HISTORY Ver. Issue Date Revisions Revised By 1 2020-08-12 Initial Release Brian T. Kiewra 2 2020-08-24 Corrected Header on p. 37. Brian T. Kiewra 3 2020-09-01 Revised antenna gain. Brian T. Kiewra REPORT NO: R13255054-E1 DATE: 2020-09-01 MODEL: GA3360 FCC ID: QFS001-10064785 Page 3 of 86 UL LLC FORM NO: 03-EM-F00858 12 Laboratory Dr., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. TABLE OF CONTENTS REVISION HISTORY .................................................................................................................. 2 TABLE OF CONTENTS ............................................................................................................. 3 1. ATTESTATION OF TEST RESULTS .................................................................................. 4 2. TEST METHODOLOGY ...................................................................................................... 6 3. FACILITIES AND ACCREDITATION .................................................................................. 6 4. DECISION RULES AND MEASUREMENT UNCERTAINTY............................................... 7 4.4. SAMPLE CALCULATION ............................................................................................. 8 5. EQUIPMENT UNDER TEST................................................................................................ 9 5.1. DESCRIPTION OF EUT ............................................................................................... 9 5.2. MAXIMUM OUTPUT POWER ...................................................................................... 9 5.3. DESCRIPTION OF AVAILABLE ANTENNAS ............................................................... 9 5.4. SOFTWARE AND FIRMWARE .................................................................................... 9 5.5. WORST-CASE CONFIGURATION AND MODE ......................................................... 10 5.6. DESCRIPTION OF TEST SETUP .............................................................................. 11 6. TEST AND MEASUREMENT EQUIPMENT ...................................................................... 12 7. RF POWER OUTPUT........................................................................................................ 14 8. EMISSIONS TEST RESULTS ........................................................................................... 18 8.1. OCCUPIED BANDWIDTH .......................................................................................... 18 8.2. BAND EDGE .............................................................................................................. 22 8.3. OUT OF BAND EMISSIONS ...................................................................................... 26 ANTENNA PORT OUT OF BAND EMISSIONS ................................................... 27 RADIATED ENCLOSURE PORT OUT OF BAND EMISSIONS ........................... 45 9. FREQUENCY STABILITY ................................................................................................. 81 10. TEST SETUP PHOTOS ................................................................................................. 85 END OF REPORT .................................................................................................................... 86 REPORT NO: R13255054-E1 DATE: 2020-09-01 MODEL: GA3360 FCC ID: QFS001-10064785 Page 4 of 86 UL LLC FORM NO: 03-EM-F00858 12 Laboratory Dr., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. 1. ATTESTATION OF TEST RESULTS COMPANY NAME: Dynetics 1002 Explorer Boulevard Huntsville, AL 35806-2806 EUT DESCRIPTION: Ground Radar MODEL: GA3360 SERIAL NUMBER: E2 DATE TESTED: 2020-04-15 to 2020-05-28 APPLICABLE STANDARDS STANDARD TEST RESULTS 47 CFR Part 90.103 Compliant UL LLC tested the above equipment in accordance with the requirements set forth in the above standards. All indications of Pass/Fail in this report are opinions expressed by UL LLC based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into account and are published for informational purposes only. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Note: The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. This document may not be altered or revised in any way unless done so by UL LLC and all revisions are duly noted in the revisions section. Any alteration of this document not carried out by UL LLC will constitute fraud and shall nullify the document. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. government. REPORT NO: R13255054-E1 DATE: 2020-09-01 MODEL: GA3360 FCC ID: QFS001-10064785 Page 5 of 86 UL LLC FORM NO: 03-EM-F00858 12 Laboratory Dr., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. Approved & Released For UL LLC by: Prepared By: Jeffrey Moser Brian T. Kiewra Operations Leader Project Engineer UL – Consumer Technology Division UL – Consumer Techno…
Text truncated - open the document above for the full version.
REPORT NO: R13255054-E1 DATE: 2020-08-12 MODEL: GA3360 FCC ID: QFS001-10064785 Page 85 of 86 UL LLC FORM NO: 03-EM-F00858 12 Laboratory Dr., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. 10. TEST SETUP PHOTOS ANTENNA PORT CONDUCTED AND FREQUENCY STABILITY ANTENNA PORT CONDUCTED PHOTO FREQUENCY STABILITY PHOTO REPORT NO: R13255054-E1 DATE: 2020-08-12 MODEL: GA3360 FCC ID: QFS001-10064785 Page 86 of 86 UL LLC FORM NO: 03-EM-F00858 12 Laboratory Dr., RTP, NC 27709 TEL: (919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC. RADIATED EMISSIONS SETUP END OF REPORT RADIATED PHOTO < 1GHz RADIATED PHOTO >1GHz
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 90 | 3.15 GHz - 3.23 GHz | 21.04 W | 16M9Q3N | 159.0000000000 ppm |

Ground Radar
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Ground Radar
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Ground Radar
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
GROUND RADAR
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter