Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Exhibit H – Operator’s Manual & Product Specification PGI International Remote Shut-Off Device
Exhibit L – Letter of Modification PGI International Remote Shut-Off Device
Exhibit J – Letter of Authorization PGI International Remote Shut-Off Device
Exhibit K – Letter of Confidentiality PGI International Remote Shut-Off Device
Exhibit F – EUT Photographs PGI International Remote Shut-Off Device PGI International Remote Shut-Off Device External – Top View External – Bottom View
Exhibit D – Equipment ID Labels and Locations PGI International Remote Shut-Off Device
Exhibit F – EUT Photographs PGI International Remote Shut-Off Device PGI International Remote Shut-Off Device External – Top View External – Bottom View PGI International Remote Shut-Off Device Internal – Top View Internal – Bottom View PGI International Remote Shut-Off Device Main Board – Up View Main View – Down View
FCC ID: QHL-RSDT-1 Professional Testing (EMI), Inc. Page 4 of 15 1.0 EUT Description The Equipment Under Test (EUT) is the PGI International Remote Shut-Off Device. The Remote Shut-Off Device is a miniature RF module that provides a cost effective high performance FM radio data link, at 433.92 MHz or 315 MHz. There are no adjustable components and ensures very reliable operation over time. The EUT operates at 433 MHz and is designed for compliance with 47 CFR 15.231 of the FCC rules. Specific test requirements for this device include the following: 47 CFR 15.231 Fundamental Transmit Power 47 CFR 15.231 & 15.205 Spurious Radiated Power 47 CFR 15.231 & 2.1049 Occupied Bandwidth (2.989 used as Procedural Reference) 47 CFR 15.203 Antenna Requirement The system tested consisted of the following: Manufacturer & Model Serial # FCC ID # Description PGI International, Remote Shut- Off Device 1026-ASY- 02 QHL-RSDT-1 RSD Transmitter 1.1 EUT Operation The Remote Shut-Off Device was held by one technician and operated by pressing a key to transmit a signal while a second technician measured and logged the transmitted signal. This procedure was performed through out the tests. Setup and operational modes cover worst-case configuration and operational modes for the device. The frequency of the transmitting signal is 433 MHz. 2.0 Electromagnetic Emissions Testing Professional Testing (EMI), Inc. (PTI), follows the guidelines of NIST for all uncertainty calculations, estimates and expressions thereof for EMC testing. Radiated emission measurements were made of the Fundamental and Spurious Emission levels for the Remote Shut-Off Device. Measurements of the occupied bandwidth were also made for the equipment. Measurements of the maximum emission levels for the fundamental and the spurious/harmonic emissions of the Remote Shut-Off Device were made at the Professional Testing "Open Field" Site 3, located in Round Rock, Texas to determine the radio noise radiated from the EUT. A “Description of Measurement Facilities” has been submitted to the FCC and approved pursuant to Section 2.948 of CFR 47 of the FCC rules. Tests of the fundamental and spurious harmonics for the device were performed to determine the worst-case polarization of the devices. The fundamental and spurious emissions of the device were measured with the antennas of the devices vertical and horizontal to the ground plane.
FCC ID: QHL-RSDT-1 Professional Testing (EMI), Inc. Page 1 of 15 Project Number: 03001-10 Prepared for: PGI INTERNATIONAL 16101 Valen Drive. Houston, TX 77041 By Professional Testing (EMI), Inc. 1601 FM 1460, Suite B Round Rock, Texas 78664 June 2002 CERTIFICATION Electromagnetic Interference Test Report PGI INTERNATIONAL Remote Shut-Off Device FCC ID: QHL-RSDT-1 Professional Testing (EMI), Inc. Page 2 of 15 Table of Contents Title Page....................................................................................................................................1 Table of Contents........................................................................................................................2 Certificate of Compliance...........................................................................................................3 1.0 EUT Description.................................................................................................................4 1.1 EUT Operation....................................................................................................................4 2.0 Electromagnetic Emissions Testing.....................................................................................4 2.1 TEST PROCEDURE.............................................................................................................5 2.2 TEST CRITERIA................................................................................................................5 2.3 TEST RESULTS.................................................................................................................5 3.0 Occupied Bandwidth Measurements....................................................................................5 3.1 TEST PROCEDURE.............................................................................................................6 3.2 TEST CRITERIA.................................................................................................................6 3.3 TEST RESULTS.................................................................................................................6 4.0 Antenna Requirement..........................................................................................................6 4.1 EVALUATION PROCEDURE................................................................................................6 4.2 EVALUATION CRITERIA....................................................................................................7 4.3 EVALUATION RESULTS.....................................................................................................7 4.4 TRANSMIT DURATION.......................................................................................................7 5.0 Modifications to Equipment................................................................................................7 6.0 List of Test Equipment........................................................................................................7 Figures Figure 1: Radiated Emissions Test Setup.....................................................................................8 Appendices Appendix A: Fundamental Emissions Test Data..........................................................................9 Appendix B: Spurious Emissions Test Data..............................................................................11 Appendix C: Occupied Bandwidth Test Data............................................................................14 FCC ID: QHL-RSDT-1 Professional Testing (EMI), Inc. Page 3 of 15 THIS REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL, WITHOUT THE WRITTEN APPROVAL OF PROFESSIONAL TESTING (EMI), INC. Applicant: PGI International Applicant’s Address: 16101 Valen Drive Houston, TX 77041 Model: Remote Shut-Off Device Serial Number: Project Number: 03001-10 I, Jeffrey A. Lenk, for Professional Testing (EMI), Inc., being familiar with the FCC rules and test procedures have reviewed the test setup, measured data and this report. I believe them to be true and accurate. The PGI International Remote Shut-Off Device was tested to and found to be in compliance with FCC Part 15 Subpart C for an Intentional Radiator. The highest emissions generated by the above equipment are listed below: Frequency (MHz) Level (dBμV/m) Limit (dBμV/m) Margin (dB) Fundamental 433.9 77.9 80.8 -2.9 Spurious Harmonics 1302 66.1 70.4 -4.3 ______________________________ Jeffrey A. Lenk President Certificate of Compliance FCC ID: QHL-RSDT-1 Professional Testing (EMI), Inc. Page 4 of 15 1.0 EUT Description The Equipment Under Test (EUT) is the PGI International Remote Shut-Off Device. The Remote Shut-Off Device is a miniature RF module that provides a cost effective high performance FM radio data link, at 433.92 MHz or 315 MHz. There are no adjustable components and ensures very reliable operation over time. The EUT operates at 433 MHz and is designed for compliance with 47 CFR 15.231 of the FCC rules. Specific test requirements for this device include the following: 47 CFR 15.231 Fundamental Transmit Power 47 CFR 15.231 & 15.205 Spurious Radiated Power 47 CFR 15.231 & 2.1049 Occupied Bandwidth (2.989 used as Procedural Reference) 47 CFR 15.203 Antenna Requirement The system tested consisted of the following: Manufacturer & Model Serial # FCC ID # Description PGI International, Remote Shut- Off Device 1026-ASY- 02 QHL-RSDT-1 RSD Transmitter 1.1 EUT Operation The Remote Shut-Off Device was held by one technician and operated by pressing a key to transmit a signal while a second technician measured and logged the transmitted signal. This procedure was performed through out the tests. Setup and operational modes cover worst-case configuration and operational modes for the device. The frequency of the transmitting signal is 433 MHz. 2.0 Electromagnetic Emissions Testing Professional Testing (EMI), Inc. (PTI), follows the guidelines of NIST for all uncertainty calculations, estima…
Text truncated - open the document above for the full version.
Exhibit E – Test Setup Photographs PGI International Remote Shut-Off Device PGI International Remote Shut-Off Device Radiated Emissions – Front View Radiated Emissions – Back View PGI International Remote Shut-Off Device Microwave Radiated Emissions – Front View Microwave Radiated Emissions – Back View
1601 FM 1460 Suite B · Round Rock, Texas · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.9 MHz - 433.9 MHz | - |