Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Intellect Sapphire 9870 DataTAC User Manual February 2002 Version 1.0 © 2002 by Intellect International N.V. All rights reserved. Intellect Sapphire 9870 DataTAC Version 1.0 • February 2002 iii Table of Contents Chapter 1 Introduction Features.......................................................................................................................................1-1 Power and Flexibility.........................................................................................................1-1 High Security.......................................................................................................................1-1 Portability and Ease of Use..............................................................................................1-1 Technical Specifications....................................................................................................1-2 Notes on Handling....................................................................................................................1-3 Important Cautions............................................................................................................1-3 AC/DC Adapter, Battery Charger..................................................................................1-3 To Prevent Malfunctions of the Unit.....................................................................................1-3 Safety Precautions......................................................................................................................1-3 Avoid Excess Moisture, Water and Dust...............................................................................1-3 Avoid High Temperatures................................................................................................1-3 When Not In Use for Prolonged Periods......................................................................1-3 Care of the Sapphire..........................................................................................................1-3 If Water Gets Inside the Unit..................................................................................................1-3 Important Notes........................................................................................................................1-4 Warning.......................................................................................................................................1-4 Note......................................................................................................................................1-4 Industry Canada Certification..........................................................................................1-4 IC Class A Compliance.....................................................................................................1-4 Names of Parts and Controls...........................................................................................1-5 Front of the Unit................................................................................................................1-5 Rear of the Unit..................................................................................................................1-6 Table of Contents ii © 2002 by Intellect International N.V. All rights reserved. February 2002 • Intellect Sapphire 9870 DataTAC Chapter 2 Preliminaries Menus..........................................................................................................................................2-1 Administration and Management Operations...............................................................2-1 Backlight (BACK LGHT).........................................................................................2-1 Power Management (PWR MGT)...........................................................................2-1 Power Status (PWR STAT).......................................................................................2-1 Auto Discharge (AUTO PWR)................................................................................2-1 Conditioning Cycle (COND BATT).......................................................................2-2 Commissioning Cycle (COMM BATT)..................................................................2-2 Settlement menu (STTL MENT).............................................................................2-3 Detail Batch Report Menu (DTL BTCH)..............................................................2-3 Totals Report Menu (TTL RPRT)...........................................................................2-3 Tips Report Menu (TIPS RPRT).............................................................................2-3 Host Totals Menu (HOST TTL)............................................................................................2-3 Clear Batch (CLR BTCH)..................................................................................2-3 Offline Settlement (OFF LINE)......................................................................2-4 Configure Close (CONF CLOS)......................................................................2-4 Configuration Menu (CON FIG)............................................................................2-5 Merchant Configuration Menu (MRCH)........................................................2-5 Communication Configuration Menu (COMM)............................................2-6 System Configuration (SYS)..............................................................................2-6 Print Configuration (PRNT).............................................................................2-6 Operator Configuration Menu (OPER)..........................................................2-6 Key Injection Menu (KEY INJ).......................................................................2-7 Parameter Download (PARM LOAD)............................................................2-7 Card Type Configuration Menu (CONF CARD)...................…
Text truncated - open the document above for the full version.
Intellect Sapphire 9870 DataTAC User Manual February 2002 Version 1.0 © 2002 by Intellect International N.V. All rights reserved. Intellect Sapphire 9870 DataTAC Version 1.0 • February 2002 iii Table of Contents Chapter 1 Introduction Features.......................................................................................................................................1-1 Power and Flexibility.........................................................................................................1-1 High Security.......................................................................................................................1-1 Portability and Ease of Use..............................................................................................1-1 Technical Specifications....................................................................................................1-2 Notes on Handling....................................................................................................................1-3 Important Cautions............................................................................................................1-3 AC/DC Adapter, Battery Charger..................................................................................1-3 To Prevent Malfunctions of the Unit.....................................................................................1-3 Safety Precautions......................................................................................................................1-3 Avoid Excess Moisture, Water and Dust...............................................................................1-3 Avoid High Temperatures................................................................................................1-3 When Not In Use for Prolonged Periods......................................................................1-3 Care of the Sapphire..........................................................................................................1-3 If Water Gets Inside the Unit..................................................................................................1-3 Important Notes........................................................................................................................1-4 Warning.......................................................................................................................................1-4 Note......................................................................................................................................1-4 Industry Canada Certification..........................................................................................1-4 IC Class A Compliance.....................................................................................................1-4 Names of Parts and Controls...........................................................................................1-5 Front of the Unit................................................................................................................1-5 Rear of the Unit..................................................................................................................1-6 Table of Contents ii © 2002 by Intellect International N.V. All rights reserved. February 2002 • Intellect Sapphire 9870 DataTAC Chapter 2 Preliminaries Menus..........................................................................................................................................2-1 Administration and Management Operations...............................................................2-1 Backlight (BACK LGHT).........................................................................................2-1 Power Management (PWR MGT)...........................................................................2-1 Power Status (PWR STAT).......................................................................................2-1 Auto Discharge (AUTO PWR)................................................................................2-1 Conditioning Cycle (COND BATT).......................................................................2-2 Commissioning Cycle (COMM BATT)..................................................................2-2 Settlement menu (STTL MENT).............................................................................2-3 Detail Batch Report Menu (DTL BTCH)..............................................................2-3 Totals Report Menu (TTL RPRT)...........................................................................2-3 Tips Report Menu (TIPS RPRT).............................................................................2-3 Host Totals Menu (HOST TTL)............................................................................................2-3 Clear Batch (CLR BTCH)..................................................................................2-3 Offline Settlement (OFF LINE)......................................................................2-4 Configure Close (CONF CLOS)......................................................................2-4 Configuration Menu (CON FIG)............................................................................2-5 Merchant Configuration Menu (MRCH)........................................................2-5 Communication Configuration Menu (COMM)............................................2-6 System Configuration (SYS)..............................................................................2-6 Print Configuration (PRNT).............................................................................2-6 Operator Configuration Menu (OPER)..........................................................2-6 Key Injection Menu (KEY INJ).......................................................................2-7 Parameter Download (PARM LOAD)............................................................2-7 Card Type Configuration Menu (CONF CARD)...................…
Text truncated - open the document above for the full version.
Intellect Sapphire 9870 DataTAC User Manual February 2002 Version 1.0 © 2002 by Intellect International N.V. All rights reserved. Intellect Sapphire 9870 DataTAC Version 1.0 • February 2002 iii Table of Contents Chapter 1 Introduction Features.......................................................................................................................................1-1 Power and Flexibility.........................................................................................................1-1 High Security.......................................................................................................................1-1 Portability and Ease of Use..............................................................................................1-1 Technical Specifications....................................................................................................1-2 Notes on Handling....................................................................................................................1-3 Important Cautions............................................................................................................1-3 AC/DC Adapter, Battery Charger..................................................................................1-3 To Prevent Malfunctions of the Unit.....................................................................................1-3 Safety Precautions......................................................................................................................1-3 Avoid Excess Moisture, Water and Dust...............................................................................1-3 Avoid High Temperatures................................................................................................1-3 When Not In Use for Prolonged Periods......................................................................1-3 Care of the Sapphire..........................................................................................................1-3 If Water Gets Inside the Unit..................................................................................................1-3 Important Notes........................................................................................................................1-4 Warning.......................................................................................................................................1-4 Note......................................................................................................................................1-4 Industry Canada Certification..........................................................................................1-4 IC Class A Compliance.....................................................................................................1-4 Names of Parts and Controls...........................................................................................1-5 Front of the Unit................................................................................................................1-5 Rear of the Unit..................................................................................................................1-6 Table of Contents ii © 2002 by Intellect International N.V. All rights reserved. February 2002 • Intellect Sapphire 9870 DataTAC Chapter 2 Preliminaries Menus..........................................................................................................................................2-1 Administration and Management Operations...............................................................2-1 Backlight (BACK LGHT).........................................................................................2-1 Power Management (PWR MGT)...........................................................................2-1 Power Status (PWR STAT).......................................................................................2-1 Auto Discharge (AUTO PWR)................................................................................2-1 Conditioning Cycle (COND BATT).......................................................................2-2 Commissioning Cycle (COMM BATT)..................................................................2-2 Settlement menu (STTL MENT).............................................................................2-3 Detail Batch Report Menu (DTL BTCH)..............................................................2-3 Totals Report Menu (TTL RPRT)...........................................................................2-3 Tips Report Menu (TIPS RPRT).............................................................................2-3 Host Totals Menu (HOST TTL)............................................................................................2-3 Clear Batch (CLR BTCH)..................................................................................2-3 Offline Settlement (OFF LINE)......................................................................2-4 Configure Close (CONF CLOS)......................................................................2-4 Configuration Menu (CON FIG)............................................................................2-5 Merchant Configuration Menu (MRCH)........................................................2-5 Communication Configuration Menu (COMM)............................................2-6 System Configuration (SYS)..............................................................................2-6 Print Configuration (PRNT).............................................................................2-6 Operator Configuration Menu (OPER)..........................................................2-6 Key Injection Menu (KEY INJ).......................................................................2-7 Parameter Download (PARM LOAD)............................................................2-7 Card Type Configuration Menu (CONF CARD)...................…
Text truncated - open the document above for the full version.
May 27, 2002 FEDERAL COMMUNICATIONS COMMISSION 7435 Oakland Mills Road Columbia, MD 21046 USA Subject: Approval Application under FCC 47 CFR, Parts 2 and 90 (Subpart I) - Licensed Non-Broadcast Radio Transceivers Operating in the Frequency Band 806-821 MHz (25 kHz Channel Spacing). Applicant: INTELLECT INTERNATIONAL N.V. Product: SAPPHIRE 9870-L Model: 9870 FCC ID: QHM-9870 Dear Sir/Madam, As appointed agent for INTELLECT INTERNATIONAL N.V., we would like to submit an application to Federal Communications Commission for certification of the above product. The Model 9870 incorporates a Radio transceiver module Model 802D manufactured by Research In Motion Ltd. (RIM), FCC ID: L6AR802D-2-O. This module is supplied as a complete OEM unit, with no tuning or modifications required for operation in this device. The only change to this modular transceiver is the transmitter’s antenna. UltraTech Engineering Labs Inc. will provide the following test data: • ERP Measurements • Transmitter Spurious/Harmonic emission measurements • SAR Evaluation Report For all other tests pertaining to FCC Part 90 and information about the radio modem module please refer to RIM’s submission. If you have any queries, please do not hesitate to contact us by our TOLL FREE number: OUR TELEPHONE NO.: 1-877-765-4173 Yours truly, Tri Minh Luu, P. Eng., V.P., Engineering TML/MT Encl. UltraTech Group of La bs 31040/SIT A96/TH/0093 46390-2049 200093-0 2 00-034 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 Telephone (905) 829-1570 Facsimile (905) 829-8050 Website: www.ultratech-labs.com Email: [email protected]
RESEARCH IN MOTION Research In Motion Limited 295 Phillip Street Waterloo, Ontario Canada N2L 3W8 +1 519 888 7465, fax +1 519 888 6906 E-mail: [email protected] Our Ref: 02400-CERT-FCC-COVER-021_mod July 8, 2002 Federal Communication Commission Equipment Authorization Division Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21045 Reference : FCC ID : L6AR802D-2-O Subject : Letter requesting confidentiality of R802D-2-O radio modem device FCC Certification application . Pursuant to CFR 47 Chapter 1 Section 0.459, Research In Motion Limited (RIM) requests that the following identified detailed technical information regarding the R802D-2-O device be held confidential by the Federal Communication Commission (FCC) and as such be withheld from public inspection. RIM does not disclose proprietary confidential information about our products to any third parties and as such we request that the FCC does the same and forward the confidentiality acceptance letter to RIM. Our FCC submissions are considered proprietary confidential information. Pursuant to CFR 47 Chapter 1 Sections 0.457(d) and 0.457(d)(2)(i) the exhibits contain details of trade secrets and technical data that is customarily guarded from competitors and not released to the public by Research In Motion Limited. The specific parts of the Exhibits indicated in this letter are considered confidential by RIM and as such should be prevented from disclosure to public and competitors. RIM has taken necessary measures to have limited access to confidential documents only to RIM internal employees on a need-to-know basis, and have signed confidentiality agreements with employees. If the disclosure of such information is made public, it will cause serious competitive harm to RIM. Previously, none of the requested confidential Exhibits have been disclosed to third parties by RIM. The following Exhibits with specific sections described, submitted with the Form 731 Attachments should be held confidential: Exhibit Parts List/Tune Up Info Procedur.doc “DOC-01606-007”, Users.doc “DOC-1606-006” CFR 47 Section 2.1033(c)(9) - Description of operational, test, and device tune-up technical procedure and operators’ manual. Section 010-10, CFR 47 Section 2.1033 (c) (10) - Description of Circuitry and Devices provided for: frequency stabilizing circuitry, suppression of spurious radiation, circuits for modulation limiting, and circuits for power limiting Exhibit Operational Description Section 010-13 and 010-13-1, CFR 47 Section 2.1033 (c) (13) - Description of digital modulation format and necessary bandwidth Exhibit Parts List/Tune Up Info Section 010-13-2 and 010-13-3, CFR 47 Section 2.1033 (c) (13) – Modulation generation methods and circuits. Detailed diagrams of modulation format and generation methods and circuits Exhibit Operational Description Section 011-1 and 011-2, CFR 47 Section 2.1033 - Detailed system and functional description Exhibit Parts List/Tune Up Info Section 011-3, CFR 47 Section 2.1033 - Detailed technical RF and power circuit description Exhibit Block Diagram 02400-CERT-FCC-BLOCK-“R802D-2-O RADIO BLOCK”, CFR 47 Section 2.1033 – Detailed technical radio modem block diagram Exhibit Schematics “RIM 802D OEM DataTAC - AMSC” SCH-02400-001 Rev B, CFR 47 Section 2.1033 (c) (10) - Complete technical schematic circuit diagrams Yours truly, Daoud S. Attayi, B.Eng. Compliance Specialist Research In Motion Limited ( 519 ) 888 – 7465 x2941 [email protected] RESEARCH IN MOTION Research In Motion Limited 295 Phillip Street Waterloo, Ontario Canada N2L 3W8 +1 519 888 7465, fax +1 519 888 6906 E-mail: [email protected] Our Ref: 02400-CERT-FCC-Cover-022_mod July 8, 2002 Federal Communications Commission Equipment Authorization Division Application Processing Branch 7435 Oakland Mills Rd. Columbia, Md. 21046 FCC ID: L6AR802D-2-O Subject: FCC Part 90 Certification Application for Research In Motion Limited, Model R802D-2-O This is to inform that Research In Motion is submitting the technical documentation of our radio modem Model R802D-2-O (existing FCC ID: L6AR802D-2-O ) in support of the application for Certification of our integrator, INTELLECT INTERNATIONAL N.V., with FCC ID: QHM- 9870. The Model R802D-2-O is a radio modem intended for integration into other equipment to allow wireless data communication. All required documents in compliance with Parts 2 and 90 of the FCC Rules have been provided in the attached Exhibits. Research In Motion would like to request confidentiality as indicated in the Form 731, Item 8 and as requested in the letter Ref: CERT-01677-021_mod, under Exhibit “Covering Letters”. Please do not hesitate to call at (519) 888-7465 x 2941 or email at [email protected] should you require additional information or have any questions. Yours truly, Daoud S. Attayi, B.Eng. Compliance Specialist Research In Motion Limited ( 519 ) 888 – 7465 x2941 [email protected]
31040/SIT A96/TH/0093 46390-2049 200093-0 2 00-034 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 Telephone (905) 829-1570 Facsimile (905) 829-8050 Website: www.ultratech-labs.com Email: [email protected] UltraTech Group of La bs August 29, 2002 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Attn: Mr. Stan Lyles Subject: Response to Correspondence dated August 15, 2002 Confirmation #: EA299429 Correspondence Reference #: 23687 Re: FCC ID: QHM-9870 Applicant: Intellect International N.V. Dear Mr. Lyles, Concerning correspondence # 23687, please see the following for our response. 1) Operational Description states TX frequency range is 806 MHz to 825 MHz and the 731 form shows frequency range is 806 MHz to 821 MHz. Please clarify. The device incorporates a radio modem supplied by Research In Motion Inc. (RIM), model R802D, FCC ID: L6AR802D-2-O. In the US the licensed frequency band for operation on DataTAC networks is 806-821 MHz. RIM 802D module supports the frequency range of 806-825 MHz, but the modules marketed in US are only operational in frequency band 806-821 MHz. Thus the upper frequency range of 821-825 MHz is software disabled and is not available for operation. 2) Please specify normal and/or expected use device and antenna positions. The normal position of the antenna is as shown on Page 9 or in the test setup photos of the SAR test report. However, it can be rotated 180 degrees around the attachment point. Normal use would most likely be hand-held at a body-worn height with antenna in the normal position as stated above. 3) Clarification of maximum conducted power. Measurements show 2W however the operational descriptions mention 2.25W is requested. Please clarify. Also, please clarify if the measured value is "burst average". Our measured conducted power is 2 Watts. RIM's FCC approval grant for the radio modem shows 2 Watts. The conducted power at the factory is calibrated to 2.00 W. The tolerance on the calibration is +/- 0.5 dB. Therefore, 2.25 W (2.00 W+0.5 dB) represented the worst case for SAR measurement. The conducted power measured was an average during a single pulse (an averaging power sensor was used with an averaging time much shorter than the pulse width). Also, if you refer to the correspondence from the original RIM radio modem certification, FCC ID: L6AR802D-2-O, a similar question regarding the 2.25W output power and the answer uploaded by RIM can be found. I have uploaded a copy of the correspondence, labeled: “Original RIM Correspondence” for your perusal. Continued... UltraTech Group of La bs 31040/SIT A96/TH/0093 46390-2049 200093-0 2 00-034 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 Telephone (905) 829-1570 Facsimile (905) 829-8050 Website: www.ultratech-labs.com Email: [email protected] 4.) SAR test results for additional body-worn positions. Please provide data for the device with it's back toward the phantom at an appropriate distance corresponding to a body-worn accessory gap. The summary of SAR results for this particular body position can be found on page 48 of the SAR report. Since it has been found to be at least 3 dB lower than the compliance limit, no further investigation were performed with this specific configuration. Please refer to the uploaded file, labeled: “Body Worn – Back” for details. 5) Additional system verification data. Manufacturer developed data supporting the target value could not be located. Also, please provide the full SAR plot and printout for the validation SAR plot included in the report. The system has been calibrated using the thermal transfer calibration procedure as shown in Section 5.6 System Calibration (pg. 26 of the SAR report). The results of this calibration are shown in Section 9.2 Temperature Transfer Calibration (pg. 53). The system verification was performed by measuring the exposure from the reference dipole, then comparing the result with the reference SAR values specified in Table 8.1 (Pg. 70 of IEEE Standards 1528). The system verification procedure employed is described in detail in Section 5.7 SAR measurement System Validation (pg. 38 of the SAR report). 6. Clarification of the date of the SAR tests and characteristics of the test liquid. Dates on page 50 and 51 do not agree with those on the SAR plots. The tissue characteristics shown on page 51 are the results of the tissue calibration performed when the tissue was initially formulated on January 9, 2002 (01/09/02). Prior to actual SAR measurements, the simulated tissue is calibrated a second time to verify the tissue characteristics; refer to page 50 for details. This verification was performed on April 2, 2002 (04/02/02), in accordance with OET 65, Supplement C (ED 01-01), page 42, which states: “The tissue media should be checked at the beginning of a series of SAR measurements to determine if the dielectric parameters are within the tolerances of the specified target values.” The computer system used to generate the SAR plots and data have regional settings that display dates in the format, (dd/mm/yyyy). The computer system used to generate the complete SAR report uses the format, (mm/dd/yyyy). Therefore, the date, 02/04/02 as shown on the SAR plots should actually be 04/02/02 which correspond to the calibration date shown on page 50. This discrepancy will be corrected for all future SAR reports. 7) Clarification of the test liquid parameters. Values measured on page 5…
Text truncated - open the document above for the full version.
3000 Bristol Circle · Oakville, Ontario · Canada
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 90 | 806 MHz - 821 MHz | 2 W | 20K0F1D | 2.5000000000 ppm |