FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Sensors & Software Inc./
  3. QJQ-PE-PRO-TLF

QJQ-PE-PRO-TLFGround Penetrating Radar

Sensors & Software Inc.
Ground Penetrating Radar - FCC ID QJQ-PE-PRO-TLF - Sensors & Software Inc.
Click to zoom

Application Details

Equipment Class
UWB - Ultra Wideband Transmitter
Date of Grant
Nov 22, 2004
Application Purpose
Original Equipment
Date of Application
Apr 21, 2004
Equipment Note
Ground Penetrating Radar
Frequency Range
0.01000000 - 733.00000000
Company
Sensors & Software Inc.
Country
Canada

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗
↗
↗

ID Label/Location Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

USER’S GUIDE Copyright 2003 Sensors & Software Inc. 2003-00376-00 pulseEKKO PRO TLF Transmitter SENSORS & SOFTWARE INC. PRODUCT LICENCE, COPYRIGHT, LIABILITY AND WARRANTY INFORMATION Important Please read this document carefully before removing the SOFTWARE PRODUCT storage media from their protective cover or assembling the HARDWARE PRODUCT. By removing the storage media or assembling the hardware, you are agreeing to be bound by the terms of this agreement. If you do not agree to the terms of this agreement, promptly contact Sen- sors & Software, Inc. at the address indicated at the end of this document. Definition The word PRODUCT as used herein defines any tangible item sold by Sensors & Software, Inc. and may be comprised of HARDWARE PRODUCT which consists of physical objects and SOFTWARE PRODUCT which means computer programs, codes and related support materials. Software Product Licence Agreement In order to preserve and protect its rights under the applicable laws, Sensors & Software, Inc. (hereafter S&S) does not sell any rights to its Software product. Rather, S&S grants the right to use its software, diskettes (or other storage media) and documentation (hereafter collectively called SOFTWARE PRODUCT) by means of a SOFTWARE PRODUCT licence. You acknowledge and agree that S&S retains worldwide title and rights to all its software and that the SOFT- WARE PRODUCT contains proprietary materials protected under copyright, trademark and trade secret laws. Grant of Software Product Licence In consideration of payment of the licence fee which is the price you pay for the SOFTWARE PRODUCT and your agree- ment to abide by the terms and conditions of this Licence Agreement, S&S grants to you, the Licensee, a non-exclu- sive right to use the SOFTWARE PRODUCT under the following conditions: Yo u m a y : •use the SOFTWARE PRODUCT on a single workstation owned, leased or otherwise controlled by you •copy the SOFTWARE PRODUCT for backup purposes in support of your use of the product on a single workstation You may not: •copy, distribute or sell copies of the SOFTWARE PRODUCT or accompanying written materials, including modified or merged SOFTWARE PRODUCT to others •sell, licence, sublicence, assign or otherwise transfer this licence to anyone without the prior written consent of S&S •modify, adapt, translate, decompile, disassemble or create derivative works based on the SOFTWARE PRODUCT Termination This licence is effective until terminated. You may terminate the licence at any time by returning the SOFTWARE PROD- UCT and all copies to S&S. The licence will automatically terminate without notice by S&S if you fail to comply with any terms or conditions of this agreement. Upon termination, you agree to return all copies of the SOFTWARE PRODUCT to S&S. Update Policy S&S may create, from time to time, updated versions of its SOFTWARE PRODUCT. At its option, S&S will make such updates available to licencees who have paid the update fee. Product Warranty, Limited Remedy and Limited Liability S&S warrants the PRODUCT to be free from defect in material and workmanship under normal use for a period of one year (365 days) from the date of shipment. Any third party computer systems or other items not manufactured directly by S&S purchased with any PRODUCT or independently from S&S are subject to the original manufacturer's warranty and not the responsibility of S&S. S&S makes no other warranties including, but not limited to, any implied warranty of merchantability or fitness for a particular purpose. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at S&S’s option to replace or repair the S&S product or refund the purchase price of the S&S product. Except where prohibited by law, S&S will not be liable for any loss or damage arising from this S&S product, whether direct, indirect, special, incidental or consequential regardless of the legal theory asserted. All statements, technical information, and recommendations related to S&S products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must eval- uate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in S&S current publications, or any contrary statements contained on your purchase order shall have not force or effect unless expressly agreed upon, in writing, by an authorized officer of S&S. S&S warrants the diskettes or other storage media on which the SOFTWARE PRODUCT is furnished to be free from defects in material and workmanship under normal use for a period of ninety (90) days from the date of purchase as evidenced by a copy of your invoice. Except as specified above, any SOFTWARE PRODUCT is provided "as is" without warranty of any kind, either expressed or implied, including, but not limited to, the use or result of use of the product in terms of correctness, accuracy, reliabil- ity, currentness or otherwise. The entire risk as to the results and performance of the PRODUCT is assumed by you. If the PRODUCT is defective or used improperly, you, and not S&S or its dealers, distributors, agents, or employees, assume the entire cost of all necessary servicing, repair or correction. S&S's entire liability and your exclusive remedy for SOFTWARE PRODUCT shall be, at S&S's option, either •the replacement of any diskette or hardware components which do not meet S&S's Limited Warranty and which are returned to S&S postage prepaid with a copy of the receipt, or •if S&S is unable to deliver a replacement diskette which is free of defects in material or workmanship, Licensee may terminate this agreement and have the licence fee refunded by returning all copies of the SOFTWARE PRODUCT postage prepaid with a copy of the receipt. If failure of any PRODUCT resulted from accident, abuse or m…

Text truncated - open the document above for the full version.

Attestation Statements

To: Joe Dichoso [email protected] FCC Application Processing Branch From: David Redman – Sensors & Software Inc. and Tri M. Luu – Ultratech Engineering Labs Inc. Re: FCC ID QJQ-PE-PRO-TLF Applicant: Sensors & Software Inc. Correspondence Reference Number: 26929 731 Confirmation Number: EA478068 1) What is the pulse width of the device? The pulse width depends on the attached antenna as outlined in the table below: Antenna Pulse Width (ns) 50 MHz 60 100 Mhz 33 200 Mhz 18 *** This information was added to the revised test report uploaded to FCC. 2) Internal photo's are not confidential because when the unit is sold, anyone can open the device. Please revise the confidential letter and resubmit. We would like some clarification on this issue. It is not clear to us why we cannot claim this since our competitors (see FCC IDs: QLAMID, QLA500MHZ, QLA100MHZ, QLA250MHZ, QLA800MHZ)have requested and obtained approval to keep their internal photos confidential. We also claim as they have that: “Specifically this material contains information relating to circuit function and system design that could be of benefit for competitors. This material contains confidential information and trade secrets that Mala Geosciene does not customarily release to the public and which is otherwise not generally available to the public.” 3) Please provide photo's of all antennas, a clearer and larger photo of the component side of the transmitter board. Photos of the antennas were already submitted to FCC with the external photos of the transmitter unit. I will send another one, just in case you not have them. I also re-submit the clearer internal photos of the transmitter board. 4) Please provide internal and external photo's of the control unit. The external and internal photos of the console unit have been uploaded to FCC E-filing per your request. 5) It appears that the 50, 100 and 200 MHz antennas are interchangeable and the antenna is not permanent as stated. How does the device comply with 15.203. The antenna connection consists of 2 pins and a unique mechanical structure that allows the attachment of the transmitter electronics to the antenna. Like any connector, there is an electrical component (the 2 pins) and a mechanical component (the shell and support structure). The uniqueness of the support structure ensures incompatibility with antennas other than those designed for this system. By its nature the system is required to be moved over the ground with all the attendant stresses on the antenna and attached electronics. Operation of the system without this coupling mechanism is impractical. See Figures 1 and 2 that show the connector on the bottom of the transmitter and on the antenna respectively. Figure 1: View of connector on bottom of transmitter. Figure 2: View of connector on antenna. 6) What antenna was used below 30 MHz? The Emco Active Loop Antenna, Model 6507, S/N: 8906-1167, Freq. Range: 1 kHz to 30 MHz were used for measurement of frequencies below 30 MHz. 7) The data for the bandwidth test does not agree with the QP data below 960 MHz. For instance, the bandwidth test data shows peaks at 270 MHz for the 200 MHz antenna, a peak at 156 MHz for the 100 MHz antenna and a peak at 42 MHz for the 50 MHz antenna. Please provide QP data at these peaks. Please refer to the revised test report for any additional tests or explanation regarding to your questions. Please note that it is not practical to relate the peak frequency in a large frequency span (970 MHz) for 10 dB BW measurement and the peak frequency in a small frequency (0Hz) span for E- field QP peak measurement since the frequency in a large frequency using the spectrum analyzer will show the inaccuracy. For example, the 30-1000 MHz span for 10 dB BW measurement, it showed the peak at 270.1 MHz, but in the zoom-in frequency span such as 2 MHz for peak measurement or 0Hz for QP measurement, the actual frequency of the peak is 288.12 MHz. 8) The bandwidth is determined by the furthest 10 dB point from the peak. The QP data shows that, for the 200 MHz antenna, there is a significant emission at 553 MHz that is almost as high as the emission at 288 MHz. See page 21. Please explain/correct accordingly for all antennas. There was an error by observing the plots for 10 dB BW, please review the revised test report for correction. As a result, the Emission Designations will be changed to “660MN0N” for 200 MHz antenna, “612MN0N” for 100 MHz antenna and “733MN0N” fro 50 MHz antenna. Please correct the emission designation in 731 form. 9) Except for measuring the peak level(when applicable), all measurements above 960 MHz uses a RMS detector. Do not use an average detector as indicated on pages 21, 23 and 25 of your report. Please re-measure and correct the report. Please find the coorections in revised test report. 10) You requested deferral of the filing. After the above is resolved, the filing will be deferred but please notify EAB a few days before the deferral date to confirm. We agree.

Cover Letter(s)

April 12, 2004 FEDERAL COMMUNICATIONS COMMISSION 7435 Oakland Mills Road Columbia, MD 21046 USA Subject: FCC Certification Authorization Application under FCC ET Docket 98-153 & FCC Part 15, Subpart F, Sec. 15.509 - Technical Requirements for Low Frequency Imaging Systems operating at 50 MHz, 100 MHz or 200 MHz. Product: Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz) Model No.: TLF FCC ID: QJQ-PE-PRO-TLF Dear Sir/Madam As appointed agent for Sensors & Software Inc., we would like to submit the application to the Federal Communications Commission for certification of the above product. Please review all necessary files uploaded to FCC OET site for detailed information. If you have any queries, please do not hesitate to contact us. Yours truly, Tri Minh Luu, P. Eng., V.P., Engineering Encl UltraTech Group of Labs 31040/SIT C-1376 46390-2049 200093-0 2 00-034 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 Tel.: (905) 829-1570 Fax.: (905) 829-8050 Website: www.ultratech-labs.com Email: [email protected]

External Photos

ANNEX 1 – EXTERNAL PHOTOGRAPHS OF EQUIPMENT UNDER Photo #1 Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz), Model No.: TLF FCC ID: QJQ-PE-PRO-TLF ANNEX 1 – EXTERNAL PHOTOGRAPHS OF EQUIPMENT UNDER Photo #1 Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz), Model No.: TLF FCC ID: QJQ-PE-PRO-TLF ANNEX 1 – EXTERNAL PHOTOGRAPHS OF EQUIPMENT UNDER Photo #1 Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz), Model No.: TLF FCC ID: QJQ-PE-PRO-TLF Pulse Ekko 100 with 200 MHz Antenna ANNEX 1 – EXTERNAL PHOTOGRAPHS OF EQUIPMENT UNDER Photo #1 Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz), Model No.: TLF FCC ID: QJQ-PE-PRO-TLF ANNEX 1 – EXTERNAL PHOTOGRAPHS OF EQUIPMENT UNDER Photo #1 Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz), Model No.: TLF FCC ID: QJQ-PE-PRO-TLF Pulse Ekko 100 with 100 MHz Antenna ANNEX 1 – EXTERNAL PHOTOGRAPHS OF EQUIPMENT UNDER Photo #1 Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz), Model No.: TLF FCC ID: QJQ-PE-PRO-TLF ANNEX 1 – EXTERNAL PHOTOGRAPHS OF EQUIPMENT UNDER Photo #1 Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz), Model No.: TLF FCC ID: QJQ-PE-PRO-TLF Pulse Ekko 100 with 50 MHz Antenna ANNEX 1 – EXTERNAL PHOTOGRAPHS OF EQUIPMENT UNDER Photo #1 Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz), Model No.: TLF FCC ID: QJQ-PE-PRO-TLF

External Photos

ANNEX 1 – EXTERNAL PHOTOGRA PHS OF EQUIPMEN T UNDER (Control Unit) Photo #12 Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz), Model No.: TLF FCC ID: QJQ-PE-PRO-TLF ANNEX 1 – EXTERNAL PHOTOGRA PHS OF EQUIPMEN T UNDER (Control Unit) Photo #13 Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz), Model No.: TLF FCC ID: QJQ-PE-PRO-TLF

External Photos

ANNEX 1 – EXTERNAL PHOTOGRAPHS OF EQUIPMENT UN DER (Transmitter & Antenna Units) Photo #1 Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz), Model No.: TLF FCC ID: QJQ-PE-PRO-TLF ANNEX 1 – EXTERNAL PHOTOGRAPHS OF EQUIPMENT UN DER (Transmitter & Antenna Units) Photo #2 Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz), Model No.: TLF FCC ID: QJQ-PE-PRO-TLF ANNEX 1 – EXTERNAL PHOTOGRAPHS OF EQUIPMENT UN DER (Transmitter & Antenna Units) Photo #3 Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz), Model No.: TLF FCC ID: QJQ-PE-PRO-TLF Pulse Ekko 100 with 200 MHz Antenna ANNEX 1 – EXTERNAL PHOTOGRAPHS OF EQUIPMENT UN DER (Transmitter & Antenna Units) Photo #4 Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz), Model No.: TLF FCC ID: QJQ-PE-PRO-TLF ANNEX 1 – EXTERNAL PHOTOGRAPHS OF EQUIPMENT UN DER (Transmitter & Antenna Units) Photo #5 Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz), Model No.: TLF FCC ID: QJQ-PE-PRO-TLF Pulse Ekko 100 with 100 MHz Antenna ANNEX 1 – EXTERNAL PHOTOGRAPHS OF EQUIPMENT UN DER (Transmitter & Antenna Units) Photo #6 Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz), Model No.: TLF FCC ID: QJQ-PE-PRO-TLF ANNEX 1 – EXTERNAL PHOTOGRAPHS OF EQUIPMENT UN DER (Transmitter & Antenna Units) Photo #7 Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz), Model No.: TLF FCC ID: QJQ-PE-PRO-TLF Pulse Ekko 100 with 50 MHz Antenna ANNEX 1 – EXTERNAL PHOTOGRAPHS OF EQUIPMENT UN DER (Transmitter & Antenna Units) Photo #8 Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz), Model No.: TLF FCC ID: QJQ-PE-PRO-TLF ANNEX 1 – EXTERNAL PHOTOGRAPHS OF EQUIPMENT UN DER (Transmitter & Antenna Units) Photo #9 Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz), Model No.: TLF FCC ID: QJQ-PE-PRO-TLF ANNEX 1 – EXTERNAL PHOTOGRAPHS OF EQUIPMENT UN DER (Transmitter & Antenna Units) Photo #10 Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz), Model No.: TLF FCC ID: QJQ-PE-PRO-TLF View of connector on bottom of transmitter ANNEX 1 – EXTERNAL PHOTOGRAPHS OF EQUIPMENT UN DER (Transmitter & Antenna Units) Photo #11 Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz), Model No.: TLF FCC ID: QJQ-PE-PRO-TLF View of connector on antenna.

ID Label/Location Info

Label 1 FCC IDENTIFIER LABELING Location of FCC Label FCC ID: QJQ-PE-PRO-TLF This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.

Test Report

April 12, 2004 FEDERAL COMMUNICATIONS COMMISSION 7435 Oakland Mills Road Columbia, MD 21046 USA Subject: FCC Certification Authorization Application under FCC ET Docket 98-153 & FCC Part 15, Subpart F, Sec. 15.509 - Technical Requirements for Low Frequency Imaging Systems operating at 50 MHz, 100 MHz or 200 MHz. Product: Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz) Model No.: TLF FCC ID: QJQ-PE-PRO-TLF Dear Sir/Madam As appointed agent for Sensors & Software Inc., we would like to submit the application to the Federal Communications Commission for certification of the above product. Please review all necessary files uploaded to FCC OET site for detailed information. If you have any queries, please do not hesitate to contact us. Yours truly, Tri Minh Luu, P. Eng., V.P., Engineering Encl UltraTech Group of Labs 31040/SIT C-1376 46390-2049 200093-0 2 00-034 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 Tel.: (905) 829-1570 Fax.: (905) 829-8050 Website: www.ultratech-labs.com Email: [email protected] April 12, 2004 Sensors & Software Inc. 1040 Stacey Court Mississauga, Ontario Canada, L4W 2X8 Attn.: Mr. David Redman Subject: FCC Certification Application Testing under FCC ET Docket 98- 153 & FCC Part 15, Subpart F, Sec. 15.509 – Technical Requirements for Low Frequency Imaging Systems operating at 50 MHz, 100 MHz or 200 MHz Product: Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz) Model No.: TLF FCC ID: QJQ-PE-PRO-TLF Dear Mr. Redman, The product sample, as provided by you, has been tested and found to comply with FCC ET Docket 98-153 & FCC Part 15, Subpart F, Sec. 15.509 - Technical Requirements for Low Frequency Imaging Systems operating at 50 MHz, 100 MHz or 200 MHz. Enclosed you will find copies of the engineering report. If you have any queries, please do not hesitate to contact us. Yours truly, Tri Minh Luu, P. Eng., V.P., Engineering Encl UltraTech Group of Labs 31040/SIT C-1376 46390-2049 200093-0 2 00-034 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 Tel.: (905) 829-1570 Fax.: (905) 829-8050 Website: www.ultratech-labs.com Email: [email protected] Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz) Model No.: TLF FCC ID: QJQ-PE-PRO-TLF Applicant: Sensors & Software Inc. 1040 Stacey Court Mississauga, Ontario Canada, L4W 2X8 In Accordance With FEDERAL COMMUNICATIONS COMMISSION (FCC) PART 15, SUBPART F, SEC. 15.509 Technical Requirements for Low Frequency Imaging Systems operating at 50 MHz, 100 MHz or 200 MHz UltraTech's File No.: SES-020FCC15UWB This Test report is Issued under the Authority of Tri M. Luu, Professional Engineer, Vice President of Engineering UltraTech Group of Labs Date: July 09, 2003 Report Prepared by: Tri Luu Tested by: Manuel D'Oliveira, Ultratech Eng. Labs Inc And David Redman Sensors & Software Inc. Issued Date: April 12, 2004 Test Dates: April 05-07, 2004 ƒ The results in this Test Report apply only to the sample(s) tested, and the sample tested is randomly selected. ƒ This report must not be used by the client to claim product endorsement by NVLAP or any agency of the US Government. UltraTech 3000 Bristol Circle, Oakville, Ontario, Canada, L6H 6G4 Tel.: (905) 829-1570 Fax.: (905) 829-8050 Website: www.ultratech-labs.com Email: [email protected], Email: [email protected] 2 31040/SIT C-1376 46390-2049 200093-0 00-034 FCC ET DOCKET 98-153 & FCC PART 15, SUBPART F, SEC. 15.509 LOW FREQUENCY IMAGING SYSTEMS Page 2 Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz), Model No.: TLF FCC ID: QJQ-PE-PRO-TLF ULTRATECH GROUP OF LABS File #: SES-020FCC15UWB 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 April 12, 2004 Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: [email protected] , Website: http://www.ultratech-labs.com ƒ All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST) TABLE OF CONTENTS EXHIBIT 1. SUBMITTAL CHECK LIST ................................................................................................................ 3 EXHIBIT 2. INTRODUCTION .................................................................................................................................. 4 2.1. SCOPE ................................................................................................................................................................. 4 2.2. RELATED SUBMITAL(S)/GRANT(S).......................................................................................................................... 4 2.3. NORMATIVE REFERENCES ............................................................................................................................ 4 EXHIBIT 3. PERFORMANCE ASSESSMENT ....................................................................................................... 5 3.1. CLIENT INFORMATION ...................................................................................................................................... 5 3.2. EQUIPMENT UNDER TEST (EUT) INFORMATION............................................................................................... 5 3.3. EUT’S TECHNICAL SPECIFICATIONS........................................................................................................... 6 3.4. LIST OF EUT’S PORTS........................................................................................................................................... 7 3.5. ANCILLARY EQUIPMENT........................................................................................................................................ 7 3.6. GENERAL TEST SETUP .................................................................................................................................... 7 EXHIBIT 4. EUT OPERATING CONDITIONS AND CONFIGURATIONS DURING TESTS ........................ 8 4.1. CLIMATE TEST CONDITIONS.....................................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

ANNEX 1 – PHOTOGRAPHS OF TEST SETUP Photo #1 Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz), Model No.: TLF FCC ID: QJQ-PE-PRO-TLF Test Configuration #1: Pul se Ekko 100 with 200 MHz Antenna ANNEX 1 – PHOTOGRAPHS OF TEST SETUP Photo #1 Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz), Model No.: TLF FCC ID: QJQ-PE-PRO-TLF Test Configuration #1: Pul se Ekko 100 with 200 MHz Antenna ANNEX 1 – PHOTOGRAPHS OF TEST SETUP Photo #1 Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz), Model No.: TLF FCC ID: QJQ-PE-PRO-TLF Test Configuration #2: Pul se Ekko 100 with 100 MHz Antenna ANNEX 1 – PHOTOGRAPHS OF TEST SETUP Photo #1 Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz), Model No.: TLF FCC ID: QJQ-PE-PRO-TLF Test Configuration #2: Pul se Ekko 100 with 100 MHz Antenna ANNEX 1 – PHOTOGRAPHS OF TEST SETUP Photo #1 Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz), Model No.: TLF FCC ID: QJQ-PE-PRO-TLF Test Configuration #3: Pul se Ekko 100 with 50 MHz Antenna ANNEX 1 – PHOTOGRAPHS OF TEST SETUP Photo #1 Pulse Ekko Pro (50 MHz, 100 MHz and 200 MHz), Model No.: TLF FCC ID: QJQ-PE-PRO-TLF Test Configuration #3: Pul se Ekko 100 with 50 MHz Antenna

Contact Information

Applicant

David Redman(Applications Engineer)
[email protected]905-624-8909Fax: 905-624-9365

Technical Contact

Ultratech Engineering Labs Inc.Tri M Luu
[email protected]1-877-747-6381

3000 Bristol Circle · Oakville, Ontario · Canada

Non-Technical Contact

Ultratech Engineering Labs Inc.Tri M Luu
[email protected]1-877-747-6381

Test Firm

UltraTech Engineering Labs Inc.Victor Kee
[email protected]9058291570Fax: 9058298050

Technical Specifications

#Rule PartsFrequency RangePower Output
115F0.01 MHz - 733 MHz-
Confidentiality
Long Term

Other Applications from Sensors & Software Inc.

Pavement Density Profiler - FCC ID QJQ-PDP1000 - Sensors & Software Inc.
QJQ-PDP1000

Pavement Density Profiler

May 19, 2021

Equipment Class

UWB - Ultra Wideband Transmitter
Ground Penetrating Radar - FCC ID QJQ-NG1000 - Sensors & Software Inc.
QJQ-NG1000

Ground Penetrating Radar

May 09, 2013

Equipment Class

UWB - Ultra Wideband Transmitter
Ground Penetrating Radar System - FCC ID QJQ-NG250 - Sensors & Software Inc.
QJQ-NG250

Ground Penetrating Radar System

Nov 22, 2011

Equipment Class

UWB - Ultra Wideband Transmitter
Noggin Gold 500 - FCC ID QJQ-NG500 - Sensors & Software Inc.
QJQ-NG500

Noggin Gold 500

Apr 25, 2011

Equipment Class

UWB - Ultra Wideband Transmitter
Noggin Gold 100 - FCC ID QJQ-NG100 - Sensors & Software Inc.
QJQ-NG100

Noggin Gold 100

Jan 23, 2011

Equipment Class

UWB - Ultra Wideband Transmitter