Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
EXHIBIT 5 User’s Manual Page 1 Zhongshan OKES Lighting Appliance Co., Ltd. Energy Saving Lamp FCC ID: QK4OKES CAUTIONS AND INSTRUCTION 1. Use only on 110-120V, 60Hz. 2. Never disassemble or modify the lamp. 3. To prevent risk of fire, never install this device in the following fixtures: a. Fixture on dimming circuits. b. Emergency exit lights powered by direct current (DC). 4. To avoid risk of electronic shock----use only in dry locations. 5. This product may cause interference to the radio equipment and should no be installed near maritime safety communications equipment or other critical navigation or communication equipment operating between 0.45-30MHz. 6. This product may produce interference when using a T.V., radio or a wireless remote control. If interference should occur, move the lamp away form such equipment three feet or more, otherwise, plug the lamp or the receiver into a different outlet. 7. To prevent burns and avoid electric shock, please do not touch the bulb or cap during operation or immediately after switching off. 8. COMPLIANCE INFORMATION STATEMENT Product Name: Energy Saving Lamp Model Number: HY2U-7W(9W), HY2U-11W(13W), HY2U-15W, HY3U-15W(13W), HY3U-20W(18W), HY3U-23W(26W), NK4A-15W(13W), NK4A -20W(18W), NK4A -23W(26W), HY4U-20W, HY4U-26W, HY4U-30W , Statement:This device complies with part 18 of FCC Rules operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that Page 2 Zhongshan OKES Lighting Appliance Co., Ltd. Energy Saving Lamp FCC ID: QK4OKES may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. This product may cause interference to the radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communication equipment operating between 0.45-30MHz. Page 3 Zhongshan OKES Lighting Appliance Co., Ltd. Energy Saving Lamp FCC ID: QK4OKES
EXHIBIT 2 External Photographs Page 1 Zhongshan OKES Lighting Appliance Co., Ltd. Energy Saving Lamp FCC ID: QK4OKES Figure 1 M/N: HY2U Series General Appearance and Label Location Figure 2 M/N: HY3U Series General Appearance and Label Location FCC ID QK4OKES FCC ID QK4OKES Page 2 Zhongshan OKES Lighting Appliance Co., Ltd. Energy Saving Lamp FCC ID: QK4OKES Figure 3 M/N: QSM, NK4A Series General Appearance and Label Location Figure 4 M/N: HY4U Series General Appearance and Label Location Page 3 Zhongshan OKES Lighting Appliance Co., Ltd. Energy Saving Lamp FCC ID: QK4OKES FCC ID QK4OKES FCC ID QK4OKES Page 4 Zhongshan OKES Lighting Appliance Co., Ltd. Energy Saving Lamp FCC ID: QK4OKES
Page 4 FCC ID: QK40KES Energy Saving Lamp Zhon~ban OKES Lighting Appliance Co., Ud. Figure 1 M/N: HY2U Series General Appearance and Label Location Figure 2 M/N: HY3U Series General Appearance and Label Location FCC ID QK4OKES FCC ID QK4OKES Page 2 Zhongshan OKES Lighting Appliance Co., Ltd. Energy Saving Lamp FCC ID: QK4OKES Figure 3 M/N: QSM, NK4A Series General Appearance and Label Location Figure 4 M/N: HY4U Series General Appearance and Label Location Page 3 Zhongshan OKES Lighting Appliance Co., Ltd. Energy Saving Lamp FCC ID: QK4OKES FCC ID QK4OKES FCC ID QK4OKES Page 4 Zhongshan OKES Lighting Appliance Co., Ltd. Energy Saving Lamp FCC ID: QK4OKES
EXHIBIT 2 Internal Photographs Page 1 Zhongshan OKES Lighting Appliance Co., Ltd. Energy Saving Lamp FCC ID: QK4OKES Figure 1 M/N: HY2U Series Main Board, Component Side Figure 2 M/N:HY2U Series Main Board, Soldered Side Page 2 Zhongshan OKES Lighting Appliance Co., Ltd. Energy Saving Lamp FCC ID: QK4OKES Figure 3 M/N: HY3U Series Main Board, Component Side Figure 4 M/N: HY3U Series Main Board, Soldered Side Page 3 Zhongshan OKES Lighting Appliance Co., Ltd. Energy Saving Lamp FCC ID: QK4OKES Figure 5 M/N: NK4A Series Main Board, Component Side Figure 6 M/N: NK4A Series Main Board, Soldered Side Page 4 Zhongshan OKES Lighting Appliance Co., Ltd. Energy Saving Lamp FCC ID: QK4OKES Figure 7 M/N: HY4U Series Main Board, Component Side Figure 8 M/N: HY4U Series Main Board, Soldered Side Page 5 Zhongshan OKES Lighting Appliance Co., Ltd. Energy Saving Lamp FCC ID: QK4OKES
EXHIBIT 3 Circuit Diagram Page 1 Zhongshan OKES Lighting Appliance Co., Ltd. Energy Saving Lamp FCC ID: QK4OKES Page 2 Zhongshan OKES Ligting Appliance Co., Ltd. Energy Saving Lamp FCC ID: QK4OKES
Page 1 Zhongshan OKES Lighting Appliance Co., Ltd. Energy Saving Lamp FCC ID: QK4OKES EXHIBIT 4 Te s t R e p o r t APPLICATION FOR CERTIFICATION On Behalf of Zhongshan OKES Lighting Appliance Co., Ltd. Energy Saving Lamp Model Number : HY2U-7W(9W), HY2U-11W(13W), HY2U-15W HY3U-15W(13W), HY3U-20W(18W), HY3U-23W(26W) NK4A-15W(13W),NK4A -20W(18W), NK4A -23W(26W) HY4U-20W, HY4U-26W, HY4U-30W Prepared for : Zhongshan OKES Lighting Appliance Co., Ltd. Gangdong Industray Zone, Guzhen Town, Zhongshan City, Guangdong China Prepared by : Shenzhen Most Technology Co., Ltd C-13B,Shennan Gardon Nanshan Zone Shenzhen Guangdong China Telephone : (0755)-26506933 Report Number : SMT-F82002 Date of Test : August 2, 2002 Date of Report : August 20-27, 2002 Page 2 Zhongshan OKES Lighting Appliance Co., Ltd. Energy Saving Lamp FCC ID: QK4OKES TABLE OF CONTENTS Description Page FCC Test Report for Declaration of Conformity 1. GENERAL INFORMATION....................................................................................................... 5 1.1. Description of Device (EUT) ...................................................................................................................... 5 1.2. Test Facility ............................................................................................................................................ 6 1.3. Test Uncertainty ......................................................................................................................................... 6 2. POWER LINE CONDUCTED EMISSION TEST..................................................................... 7 2.1. Test Equipment........................................................................................................................................... 7 2.2. Block Diagram of Test Setup ..................................................................................................................... 7 2.3. Power Line Conducted Emission Test Limits............................................................................................. 7 2.4. Configuration of EUT on Test.................................................................................................................... 7 2.5. Operating Condition of EUT ...................................................................................................................... 8 2.6. Test Procedure ............................................................................................................................................ 8 2.7. Power Line Conducted Emission Test Results ........................................................................................... 8 3. MODIFICATION TO TEST SPECIFICATIONS ................................................................... 12 4. PHOTOGRAPH........................................................................................................................... 13 4.1. Photo of Power Line Conducted Emission Test ....................................................................................... 13 APPENDIX I (12 pages) Page 3 Zhongshan OKES Lighting Appliance Co., Ltd. Energy Saving Lamp FCC ID: QK4OKES Page 4 Zhongshan OKES Lighting Appliance Co., Ltd. Energy Saving Lamp FCC ID: QK4OKES 1. GENERAL INFORMATION 1.1. Description of Device (EUT) Description : Energy Saving Lamp Model Number : HY2U-7W(9W), HY2U-11W(13W), HY2U-15W HY3U-15W(13W), HY3U-20W(18W), HY3U-23W(26W) NK4A-15W(13W), NK4A -20W(18W), NK4A -23W(26W) HY4U-20W, HY4U-26W, HY4U-30W Applicant : Zhongshan OKES Lighting Appliance Co., Ltd. Gangdong Industray Zone, Guzhen Town, Zhongshan City, Guangdong China Manufacturer : Zhongshan OKES Lighting Appliance Co., Ltd. Gangdong Industray Zone, Guzhen Town, Zhongshan City, Guangdong China Date of Test : August 2, 2002 Page 5 Zhongshan OKES Lighting Appliance Co., Ltd. Energy Saving Lamp FCC ID: QK4OKES Test Facility Site Description 3m Anechoic Chamber : Certificated by FCC, USA Aug. 24, 2000 3m & 10m Open Site : Certificated by FCC, USA Feb. 13, 1998 EMC Lab. : Certificated by VCCI, Japan Oct. 29, 1998 Certificated by DATech, German Feb. 02, 1999 Certificated by NVLAP, USA until Mar. 03, 2001 NVLAP Code: 200372-0 Certificated by DNV, Norway May 26, 1999 Name of Firm : Audix Technology (Shenzhen) Co., Ltd. Site Location : No. 6, Ke Feng Rd., 52 Block, Shenzhen Science & Industrial Park, Nantou, Shenzhen, Guangdong, P.R China 1.3. Test Uncertainty Conducted Emission Uncertainty = ±2.66dB Radiated Emission Uncertainty = ±4.26dB : Page 6 Zhongshan OKES Lighting Appliance Co., Ltd. Energy Saving Lamp FCC ID: QK4OKES 2. POWER LINE CONDUCTED EMISSION TEST 2.1 Test Equipment The following test equipments are used during the power line conducted emission test: Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. Test Receiver Rohde & Schwarz ESHS20 836600/006 Jun. 04, 02 1 Year 2. L.I.S.N. Kyoritsu KNW-407 8-541-4 Jun. 04, 02 1 Year 3. Terminator EMCO 50Ω No. 1 Jun. 04, 02 1 Year 4. Terminator EMCO 50Ω No. 2 Jun. 04, 02 1 Year 5. RF Cable FUJIKURA RG-55/U LISN Cable Feb 28, 02 1/2 Year 6. Passive Probe Rohde & Schwarz ESH-Z3 299.7810.52 Jun. 04, 02 1 Year 7. Coaxial Switch Anritsu MP59B M73989 Feb.28, 02 1/2 Year 2.2 Block Diagram of Test Setup Block diagram of connection between the EUT and simulators (EUT: Saving Lamp) 2.3 Power Line Conducted Emission Test Limits Maximum RF Line Voltage Frequency MHz dB(μV) 0.45 ~ 2.51 48 2.51~ 3.0 70 3.0 ~ 30 48 2.4 Configuration of EUT on Test The following equipment are installed on Power Line Conducted Emission Test to meet the commission requirement and operating regulations in a manner which tends to maximize its emission characteristics in a normal application. 2.4.1 Saving Lamp (EUT) Model Number : HY2U-7W(9W), HY2U-11W(13W), HY2U-15W, HY3U-15W(13W), HY3U-20W(18W), HY3U-23W(26W), NK4A-15W(13W), NK4A -20W(18W), NK4A -23W(26W), HY4U-20W, HY4U-26W, HY4U-30W Manufacturer : Zhongshan OKES Lighting…
Text truncated - open the document above for the full version.
Setup Zhongshan OKES Lighting Appliance Co., Ltd. Energy Saving Lamp FCC ID: QK4OKES SETUP PHOTOGRAPH 1.1. Photo of Power Line Conducted Emission Test Page 2 Zhongshan OKES Lighting Appliance Co., Ltd. Energy Saving Lamp FCC ID: QK4OKES
230 Commercial Street · Sunnyvale, California · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 18 | 0.04 MHz - 0.05 MHz | - |