FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. International Sales Corporation/
  3. QOZ-HRSENSOR

QOZ-HRSENSORHeart Rate Sensor

International Sales Corporation
Heart Rate Sensor - FCC ID QOZ-HRSENSOR - International Sales Corporation
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Nov 03, 2014
Application Purpose
Original Equipment
Date of Application
Nov 03, 2014
Equipment Note
Heart Rate Sensor
Frequency Range
2402.00000000 - 2480.00000000
Company
International Sales Corporation
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

TecSmart Heart Rate Monitor Instruction Manual (GB) THR-200BT Bluetooth® Smart + 5.3kHz Dual Band Heart Rate Monitor THR-200BT is water resistant. www.dragon-ample.com.hk Dragon Ample Internationl Limited Bluetooth® is a registered trademark of Bluetooth SIG, Inc. *App Store is a service mark of Apple Inc. Box contents 1. THR-200BT (sensor) x 12. Fabric strap x 1 3. Battery (CR2032) THR-200BT overview THR-200BT battery setup Wearing the THR-200BT Pairing the THR-200BT Technology: Bluetooth® Smart / RF 5.3kHz Battery life: up to 300 hours Operating temperature: -10°C ~ +50°C Transmission range: 10 meters (Bluetooth) Water resistant level: IPX7 Sensor dimension (LxWxH): 64.75 x 35.70 x 12.4 mm Weight: 15.3g (without CR2032 battery) Technical specication DisclaimersWarranty Maintainence of fabric strap 1.) Twisting the battery door counter-clock wise with a coin until it’s open (Fig1.) 1.) Apply water or conductive GEL onto the surface of the conductive pads (Fig.4) 2.) Attach the sensor to the snap buttons on the strap (Fig.5) 3.) Wrap the strap around and right below your chest and then fasten (note: make sure adjust the strap to be most comfortable t) (Fig.6) 4.) Locate the THR-200BT right in the middle and just below your chest (Fig.7) 1.) Download and install the TecSmart TSHR app from App Store (for FREE download) 2.) Make sure Bluetooth is turn “ON” on your Bluetooth Smart enabled device 3.) Pair your THR-200BT and start (Note: Refer to the instruction on the appstore for the pairing and setup procedure) Note: THR-200BT is also compatible with the devices and gym equipments that work with 5.3kHz (non-coded) signal, please refer to your product service counter or technician for more information 2.) Inset the new battery to the battery door with the negative side facing up (Fig.2) **Note: Always wait approximately 40 seconds before replacing a new battery 3.) Replace the battery door to the compartment and rotate clock wise until the “lock icon” is pointing to the mark (Fig.3) THR-200BT works with iPhone4S, 5, 5C, 5S, iPod Touch, iPad 2, 3, 4, New, Mini, Mini 2, Air (iOS 6.1 or higher required) OR other Bluetooth Smart enabled devices. THR-200BT is best used with the TecSmart TSHR app OR other Bluetooth Smart compatible app THR-200BT Sensor Front view Battery door & compartment Snap buttons Back view Conductive pads Fabric strap front & back view H2OH2O Fig.4 Fig.5 Fig.6 Fig.7 Fig.1 Fig.3 RISKS FOR CHILDREN AND PEOPLE IN NEED OF CARE The use of this device is not intended for people (including children) with limited physical, sensory or mental abilities or lack of experience and/or lack of knowledge, unless they are supervised by a person responsible for their safety or have been instructed on the use of the device. DISPOSAL Batteries are hazardous waste. For the correct disposal of batteries appropriate containers are provided at the premises of commercial battery dealers as well as local council waste disposal facilities. If you want to dispose of your transmitter with chest strap, follow the provisions current at the time. Information may be obtained from the local council waste disposal facility. Fig.2 (-) (+) Copyr ight ,Inc. 2014 Do not iron or press. Do not dry-clean. Do not bleach. Do not tumble dry. APP: TSHR 5.3kHz Thank you for purchasing the TecSmart THR-200BT Chest belt. Please read this instruction manual before using this unit. To ensure safe and correct use., please keep this instruction manual for your future reference. SAFETY ADVICE Important: Always consult your doctor before you begin a regular exercise programme. The transmitter with chest strap is not a medical device. It is a training tool for the measurement and display of your heart rate. People with pacemaker devices may only use heart rate measurement devices after consulting with the doctor. Wash in domestic or commercial machine in water not exceeding 40°C, at normal setting. We provide a 12 months warranty for this product. The warranty period begins on the date of purchase (till receipt, purchase voucher). During this period you will receive free of charge a new or repaired product. The warranty does not include batteries, improper handling, dropping, shock or the like. In case of a claim you have the following possibilities: a) contact your point of sale or b) write us an e-mail: [email protected] iPhone® is a trademark of Apple Inc., registered in the U.S. and other countries. TSHR Warning: Changes or modications to this unit not expressly approved by the party responsible for compliance could void the user authority to operate the equipment. In addition, the user manual shall include the following or similar statement, placed in a prominent location in the text of the manual: NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installa- tion. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and …

Text truncated - open the document above for the full version.

External Photos

External Photo

Internal Photos

Internal Photo

Test Report

TEST REPORT Report No. : AS0059148(5) Date : 07 Oct 2014 For and on behalf of CMA Industrial Development Foundation Limited Authorized Signature : Page 1 of 28 Mr. WONG Lap-pong, Andrew Manager Electrical Division FCC ID: QOZ-HRSENSOR Application No. : LS019587(8) Applicant : International Sales Corporation 8 th Floor, Pan Asia Centre, 137 Wai Yip Street, Kwun Tong, Kowloon, Hong Kong Sample Description : One(1) item of submitted sample stated to be Heart Rate Monitor of Model No. THR-200BT Sample registration No. : RS022546-001 Radio Frequency : 2402MHz – 2480 MHz Transceiver Rating : 1 x 3V button cell No. of submitted sample : Six (6) piece (s) Date Received : 04 Jun 2014 Test Period : 05 Jun 2014 to 19 Jun 2014. Test Requested : FCC Part 15 Certificate Test Method : 47 CFR Part 15 (10-1-12 Edition), ANSI C63. 4 – 2009 Test Engineer : Mr. LEUNG Shu-kan, Ken Test Result : See attached sheet(s) from page 2 to 28. Conclusion : The submitted sample was found to comply with requirement of FCC Part 15 Subpart B and C. TEST REPORT Report No. : AS0059148(5) Date : 07 Oct 2014 Page 2 of 28 FCC ID: QOZ-HRSENSOR Table of Contents 1 General Information ................................................................................................................................... 3 1.1 General Description ............................................................................................................................ 3 1.2 Location of the test site ....................................................................................................................... 4 1.3 List of measuring equipment............................................................................................................... 5 1.4 Measurement Uncertainty ................................................................................................................... 6 2 Description of the radiated emission test ................................................................................................... 7 2.1 Test Procedure .................................................................................................................................... 7 2.2 Test Result .......................................................................................................................................... 8 2.3 Radiated Emission Measurement Data ............................................................................................... 9 3 Description of the Line-conducted Test ................................................................................................... 12 3.1 Test Procedure .................................................................................................................................. 12 3.2 Test Result ........................................................................................................................................ 12 3.3 Graph and Table of Conducted Emission Measurement Data .......................................................... 12 4 Photograph ............................................................................................................................................... 13 4.1 Photographs of the Test Setup for Radiated Emission and Conducted Emission ............................. 13 4.2 Photographs of the External and Internal Configurations of the EUT .............................................. 13 5 Supplementary document ......................................................................................................................... 14 5.1 Bandwidth ......................................................................................................................................... 14 5.2 Duty cycle ......................................................................................................................................... 14 5.3 Transmission time ............................................................................................................................. 14 5.4 Power Spectral Density ..................................................................................................................... 14 5.5 Average on time ................................................................................................................................ 14 6 Appendices ............................................................................................................................................... 15 TEST REPORT Report No. : AS0059148(5) Date : 07 Oct 2014 Page 3 of 28 FCC ID: QOZ-HRSENSOR 1 General Information 1.1 General Description The equipment under test (EUT) is a transceiver for Heart Rae Monitor. The EUT is power by 1 x 3V button cell. The EUT will check the human heart rate and send the data to other wireless device. The brief circuit description is listed as follows: - U1 and its associated circuit act as MCU - U2 and its associated circuit act as RF module TEST REPORT Report No. : AS0059148(5) Date : 07 Oct 2014 Page 4 of 28 FCC ID: QOZ-HRSENSOR 1.2 Location of the test site FCC Registered Test Site Number: 552221 Radiated emissions measurements are investigated and taken pursuant to the procedures of ANSI C63.4 – 2009. A Semi-Anechoic Chamber Testing Site is set up for investigation and located at: Ground Floor, Yan Hing Centre, 9 – 13 Wong Chuk Yeung Street, Fo Tan, Shatin, New Territories, Hong Kong. Conducted emissions measurements are investigated and also taken pursuant to the procedures of ANSI C63.4 – 2009. A shielded room is located at : Ground Floor, Yan Hing Centre, 9 – 13 Wong Chuk Yeung Street, Fo Tan, Shatin, New Territories, Hong Kong. TEST REPORT Report No. : AS0059148(5) Date : 07 Oct 2014 Page 5 of 28 FCC ID: QOZ-HRSENSOR 1.3 List of measuring equipment Equipment Manufacturer Model No. Serial No. Calibration Due Date Calibration Period EMI Test Receiver R&S ESCI 100152 08 Jul 2014 1Year Spectrum Analyzer R&S FSV40 100964…

Text truncated - open the document above for the full version.

Test Report

TEST REPORT Report No. : AS0059148(5) Date : 07 Oct 2014 Tested by: Reviewed by: Mr. LEUNG Shu-kan, Ken Mr. WONG Lap-pong, Andrew Page 25 of 28 FCC ID: QOZ-HRSENSOR A5. Band Edge Lower edge (Peak measurement) Lower edge (Average measurement) TEST REPORT Report No. : AS0059148(5) Date : 07 Oct 2014 Tested by: Reviewed by: Mr. LEUNG Shu-kan, Ken Mr. WONG Lap-pong, Andrew Page 26 of 28 FCC ID: QOZ-HRSENSOR A5. Band Edge Higher edge (Peak measurement) Higher edge (Average measurement)

Test Report

TEST REPORT Report No. : AS0059148(5) Date : 07 Oct 2014 Tested by: Reviewed by: Mr. LEUNG Shu-kan, Ken Mr. WONG Lap-pong, Andrew Page 27 of 28 FCC ID: QOZ-HRSENSOR A6. 20dB Bandwidth Plot Bandwidth 1 (2402MHz) Bandwidth 2 (2440MHz) TEST REPORT Report No. : AS0059148(5) Date : 07 Oct 2014 Tested by: Reviewed by: Mr. LEUNG Shu-kan, Ken Mr. WONG Lap-pong, Andrew Page 28 of 28 FCC ID: QOZ-HRSENSOR A6. 20dB Bandwidth Plot Bandwidth 3 (2480MHz) ***** End of Report *****

Test Setup Photos

Test Setup Photo Front view (30MHz – 1GHz) Rear view (30MHz – 1GHz) Front view (9kHz – 30MHz) Rear view (9kHz – 30MHz) Front view (1GHz – 25GHz) Rear view (1GHz – 25GHz)

Contact Information

Applicant

Daniel Ip(Senior Engineer)
[email protected]852 2763 1678Fax: 852 2344 8671

Test Firm

CMA Industrial Development Foundation LimitedJoey Kwok
[email protected]+852 2690 8255

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz-
Confidentiality
Long Term

Other Applications from International Sales Corporation

Remote Control Door Chime - FCC ID QOZRF-1000T - International Sales Corporation
QOZRF-1000T

Remote Control Door Chime

Dec 09, 2002

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter