Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 02, 2015
Application Purpose
Original Equipment
Date of Application
Jun 29, 2015
Equipment Note
Point-to-Point & Point-to-Multipoint broadband wireless bridge
Frequency Range
5745.00000000 - 5830.00000000
Company
WaveIP Ltd.
Country
Israel

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

W W i i p p A A i i r r 8 8 0 0 0 0 0 0 I I n n s s t t a a l l l l a a t t i i o o n n a a n n d d O O p p e e r r a a t t i i o o n n I I n n s s t t r r u u c c t t i i o o n n s s March 2015 WaveIP Ltd. Teradion Industrial Park Misgav 20179, Israel Tel: 972-4-902-7000 Fax: 972-4-999-0324 [email protected] The information contained in this document is of commercial value, proprietary to WaveIP. It is conveyed to the recipient solely for the purpose of evaluation. Reproduction of this document, disclosure of its contents or any other use of the information herein is strictly forbidden unless expressly authorized in writing by WaveIP. WaveIP Ltd. WipAir Installation Guide Page 2 of 26 N N o o t t i i c c e e s s Radio Frequency Statement WipAir has been tested and found to comply with part 15 of the FCC rules and EN 301 489-1 rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential environment notwithstanding use in commercial, business and industrial environments. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.                                                                                        IMPORTANT! The device must be installed only for fixed, Point-to-Point or Point-to-Multipoint operations per 15.247(c)(1)(iii)                                                                                                                                                                               IMPORTANT! It is the responsibility of the installer to ensure that when using the outdoor antenna kits in the United States (or where FCC rules apply), only those antennas certified with the product are used. The use of any antenna other than those certified with the product is expressly forbidden in accordance to FCC rules CFR47 part 15.204.                                                                                                                                                                               IMPORTANT! Outdoor units and antennas should be installed ONLY by experienced installation professionals who are familiar with local building and safety codes and, wherever applicable, are licensed by the appropriate government regulatory authorities. Failure to do so may void the product warranty and may expose the end user or the service provider to legal and financial liabilities. WaveIP and its resellers or distributors of this equipment are not liable for injury, damage or violation of regulations associated with the installation of outdoor units or antennas.                                                                                        R&TTE Declaration on Conformity Hereby, WaveIP Ltd, declares that WipAir is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. The declaration of conformity may be consulted through WaveIP Ltd., Teradion Industrial Park, Misgav 20179, Israel. WaveIP Ltd. WipAir Installation Guide Page 3 of 26 Compliance with European Union WEEE Directives In January 2003, the European Union adopted an important environmental directive - - the Directive on Waste Electrical and Electronic Equipment (WEEE). It represents an important milestone in providing a safer environment for future generations. The WEEE label and instructions for disposal are as follows: Instructions for Disposal of Waste Equipment by Users in the European Union This symbol on the product or its packaging indicates that this product must not be disposed of with other waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact WaveIP. Warranty WaveIP warrants that this product shall be free from defects in workmanship and materials for a period of one year from the date of original purchase. If the product should fail to operate correctly in normal use during the warranty period, WaveIP will replace or repair it free of charge. No liability can be accepted for damage due to misuse or circumstances outside WaveIP’s control. WaveIP will not be responsible for any loss, damage or injury arising directly or indirectly from the use of this product. WaveIP’s total liability under the terms of this warranty shall in all circumstances be limited to the replacement value of this product. If any difficulty is experienced in the installation or use …

Text truncated - open the document above for the full version.

Cover Letter(s)

WaveIP Ltd. ; Teradion Industrial Park ; Misgav 20179, Israel Tel: 972-4-902-7000 ; Fax: 972-4-999-0324 web: www.waveip.com May. 18, 2015 Federal Communications Commission. 7354 Oakland Mills Road Columbia, MD 21046 Cover Letter Subject: Application for certification of Radio System, model: WipAir 8000 5X. FCC ID: QQ2-WA8K 5X Dear Gentlemen, Please find attached our application for certification of point-to-point and point-to multipoint broadband wireless communication system, FCC ID: QQ2-WA8K 5X. Prepared in accordance with FCC Rules Part 15.247, (5.8GHz), and FCC CFR 47 Part 90 subpart Y (4.9GHz) to the best of my knowledge. These tests were performed using measurement procedures consistent with industry and commission standards and demonstrate that the equipment complies with the appropriate standards. Each unit manufactured, imported or marketed, as defined in the commission regulations will conform to the test sample tests within the variations that can be expected due to quantity production and testing on a statistical basis’s. We further certify that the necessary measurements were made by Elbit Systems Land and C4I Ltd., EMC Laboratory, Hashoftim 26 St. Holon 58102 Israel. Elbit Systems Land and C 4 I Ltd. EMC Laboratory responsible person is Mr. Samuel Cohen, Tel: 972 35574476 Fax:972 35575320 e-mail: [email protected]. We hope this application satisfies your requirements Regards Amit Arazi

Cover Letter(s)

WaveIP Ltd. ; Teradion Industrial Park ; Misgav 20179, Israel Tel: 972-4-902-7000 ; Fax: 972-4-999-0324 web: www.waveip.com May. 18, 2015 Federal Communications Commission. 7354 Oakland Mills Road Columbia, MD 21046 FCC confidentiality form. FCC ID:QQ2-WA8K5X. Dear Gentlemen, This letter comply with Section 0.457(d)(2)(i), and 0.459 pertaining to confidential material. WaveIP LTD would like the following documents regarding this submission for FCC ID: QQ2-WA8K5X to be kept confidential. 1) System schematic 2) Block & Clock Diagram 3) Power Diagram 4) Part List 5) Tune-UP Procedure The above material contains trade secrets to technical data, which would customarily be guard from compatitors. We do not want thesse documents to be acceessible to general public. The product is a non-consumer device and is inaccessible to general public . The product is mounted on top of large towers and mounting poles, and serviceable only by the licensee or his designated technicians. Sincerely Amit Arazi

External Photos

Back side Top View

ID Label/Location Info

FCC ID: QQ2-WA8K5X This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Model: WipAir 8000 Made in Israel

ID Label/Location Info

FCC- Label location

RF Exposure Info

WipAir 8000 4.9GHz RF Hazard Distance Calculation Antenna gain Max TX Power EIRP Safe distance dBi Numeric dBm mW dBm mW cm 27 501.1872 29.104 813.5795 56.104 407755.7 180.1337408 Max TX power 29.104 obtained at low frequency 4943MHz at 20MHz channel BW. General public will not be exposed to dangerous RF level, when the fixed radio device will be used at distance above 180.1337 Cm. When using the system for applications, all outdoor units must be installed with aseparation distance of at least 2.5 meters from all persons during normal operation. Warning in the user manual will be provided

Test Report

WipAir 8000 5X FCC TX 15.247-Part 1 115/116 EMC/30020FC15002 05.01.2015 Plot Out of Band Conducted Emission/ 85 dBm 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 SoftPlot Measurement Presentation Trace A Start: 26.5000 GHzStop: 40.0000 GHz Res BW : 1 MHzVid BW : 3 MHzSweep: 337.50 ms 1/8/2015 11:26:07 AME7405A Mkr Trace X-Axis Value Notes 1 1 Trace A 38.9875 GHz-31.46 dBm Plot Out of Band Conducted Emission/ 86 WipAir 8000 5X FCC TX 15.247-Part 1 116/116 EMC/30020FC15002 05.01.2015 dBm 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 SoftPlot Measurement Presentation Trace A Start: 26.5000 GHzStop: 40.0000 GHz Res BW : 1 MHzVid BW : 3 MHzSweep: 337.50 ms 1/8/2015 11:24:21 AME7405A Mkr Trace X-Axis Value Notes 1 1 Trace A 38.8863 GHz-30.88 dBm Plot Out of Band Conducted Emission/ 87 dBm 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 SoftPlot Measurement Presentation Trace A Start: 26.5000 GHzStop: 40.0000 GHz Res BW : 1 MHzVid BW : 3 MHzSweep: 337.50 ms 1/8/2015 11:21:50 AME7405A Mkr Trace X-Axis Value Notes 1 1 Trace A 39.2913 GHz-30.48 dBm Plot Out of Band Conducted Emission/ 88

Test Report

WipAir 8000 5X FCC TX 15.247-Part 1 REV  DESCRIPTION SHEET EFFECTED DATE DRAWN CHECKED A 12.05.2015 M. Reuben S. Cohen Fonction/Title Name Signature Date Prepared by: Technical Writer M. Reuben 05.01.2015 Checked by: Test Engineer I. Arbitman 11.05.2015 Approved By: EMC Lab. Manager S. Cohen 19-May-15 1/116 EMC/30020FC15002 05.01.2015 WipAir 8000 5X FCC TX 15.247-Part 1 2/116 EMC/30020FC15002 05.01.2015 TABLE OF CONTENTS Para No. Title Page. No. 1. ADMINISTRATIVE DATA ............................................................................................................. 7 2. GENERAL INFORMATION ............................................................................................................ 7 3. TEST SUMMARY AND SIGNATURES. ............................................................................................ 8 4. E.U.T INFORMATION .................................................................................................................. 9 5. OCCUPIED BANDWIDTH ........................................................................................................... 11 6. PEAK OUTPUT POWER .............................................................................................................. 26 7. POWER IN PTMP MODE ........................................................................................................... 44 8. OUT OF BAND CONDUCTED EMISSION ...................................................................................... 71 List of Figures Figure No. Title Page. No. Figure 1: Measurement test setup .................................................................................................................... 12 Plot Occupied BW 6dB/ 1 ................................................................................................................................. 14 Plot Occupied BW 6dB/ 2 ................................................................................................................................. 14 Plot Occupied BW 6dB/ 3 ................................................................................................................................. 15 Plot Occupied BW 6dB/ 4 ................................................................................................................................. 15 Plot Occupied BW 6dB/ 5 ................................................................................................................................. 16 Plot Occupied BW 6dB/ 6 ................................................................................................................................. 16 Plot Occupied BW 6dB/ 7 ................................................................................................................................. 17 Plot Occupied BW 6dB/ 8 ................................................................................................................................. 17 Plot Occupied BW 6dB/ 9 ................................................................................................................................. 18 Plot Occupied BW 6dB/ 10 ............................................................................................................................... 18 Plot Occupied BW 6dB/ 11 ............................................................................................................................... 19 Plot Occupied BW 6dB/ 12 ............................................................................................................................... 19 Plot Occupied BW 6dB/ 13 ............................................................................................................................... 20 Plot Occupied BW 6dB/ 14 ............................................................................................................................... 20 Plot Occupied BW 6dB/ 15 ............................................................................................................................... 21 Plot Occupied BW 6dB/ 16 ............................................................................................................................... 21 Plot Occupied BW 6dB/ 17 ............................................................................................................................... 22 Plot Occupied BW 6dB/ 18 ............................................................................................................................... 22 Plot Occupied BW 6dB/ 19 ............................................................................................................................... 23 Plot Occupied BW 6dB/ 20 ............................................................................................................................... 23 Plot Occupied BW 6dB/ 21 ............................................................................................................................... 24 Plot Occupied BW 6dB/ 22 ............................................................................................................................... 24 Plot Occupied BW 6dB/ 23 ............................................................................................................................... 25 Plot Occupied BW 6dB/ 24 ............................................................................................................................... 25 Photograph for Conducted Measurement Test Setup/ 1 ...................................................................................... 31 Plot Peak Output Power/ 1 ............................................................................................................................... 32 Plot Peak Output Power/ 2 ............................................................................................................................... 32 Plot Peak Output Power/ 3 ............................................................…

Text truncated - open the document above for the full version.

Test Report

WipAir 8000 5X FCC TX 15.247-Part 1 39/116 EMC/30020FC15002 05.01.2015 Plot Peak Output Power/ 15 Plot Peak Output Power/ 16 WipAir 8000 5X FCC TX 15.247-Part 1 40/116 EMC/30020FC15002 05.01.2015 Plot Peak Output Power/ 17 Plot Peak Output Power/ 18 WipAir 8000 5X FCC TX 15.247-Part 1 41/116 EMC/30020FC15002 05.01.2015 Plot Peak Output Power/ 19 Plot Peak Output Power/ 20 WipAir 8000 5X FCC TX 15.247-Part 1 42/116 EMC/30020FC15002 05.01.2015 Plot Peak Output Power/ 21 Plot Peak Output Power/ 22 WipAir 8000 5X FCC TX 15.247-Part 1 43/116 EMC/30020FC15002 05.01.2015 Plot Peak Output Power/ 23 Plot Peak Output Power/ 24 WipAir 8000 5X FCC TX 15.247-Part 1 44/116 EMC/30020FC15002 05.01.2015 7 7 . . P P O O W W E E R R I I N N P P T T M M P P M M O O D D E E Equipment Under Test WipAir 8000 5X Test Method FCC New Guidance on Measurements for DTS in section 15.247(b), Option 2, Method #3. Date 12.05.2015 Relative Humidity 40% Ambient Temperature 25 0 C Air Pressure 1010 hPa Test Setup Figure 2 Testing Engineer: I. Arbitman Date 12.05.2015 7 7 . . 1 1 . . T T e e s s t t R R e e s s u u l l t t s s S S u u m m m m a a r r y y & & C C o o n n c c l l u u s s i i o o n n s s The E.U.T was found in compliance with Peak Output Power requirements 7 7 . . 2 2 . . L L i i m m i i t t s s o o f f P P e e a a k k O O u u t t p p u u t t P P o o w w e e r r a a c c c c o o r r d d i i n n g g 1 1 5 5 . . 2 2 4 4 7 7 ( ( b b ) ) The test unit shall meet the limits of Table 1 Table 25: Limits for Fundamental Assigned Frequency (MHz) Modulation Envelope Reference Points* (dBi) Peak Output Power W dBm 902.0 – 928.0 6.0 1.0 30.0 2400.0 – 2483.5 5725.0 – 5850.0 *: If transmitting antennas of directional gain greater than 6 dBi are used, the peak output power limit shall be reduced below the .stated value as follows:  By 1 dB for every 3 dB that the directional gain of antenna exceeds 6 dBi for fixed point to point transmitters operate in 2400 – 2483.5 MHz band.  Without any corresponding reduction for fixed-point-to-point transmitters operate in 5725 – 5850 MHz band;  By the amount in dB that the directional gain of antenna exceeds 6 dBi for the rest of transmitters. 7 7 . . 3 3 . . T T e e s s t t I I n n s s t t r r u u m m e e n n t t a a t t i i o o n n a a n n d d E E q q u u i i p p m m e e n n t t Table 26: Test Instrumentation and Equipment Item Model Manufacturer P/N Next Date of Calibration Spectrum Analyzer N9020A Agilent 20041738908 04.04.2015 20 dB Attenuator 8343-206 TENULINE 13.03.2016 7 7 . . 4 4 . . T T e e s s t t P P r r o o c c e e d d u u r r e e The EUT was set to transmit at 100% duty cycle, at appropriate output power levels for 2 typical antenna gain of 23 dBi and 28.5 dBi. Power measurements were performed for top, middle and bottom frequencies, for each channel, BW 5, 10, 20 and 40 MHz The EUT was connected to the spectrum analyzer through an appropriate attenuator and accounted for cable loss in the settings. Note: The 20dB attenuator has been considered in the measurements results. WipAir 8000 5X FCC TX 15.247-Part 1 45/116 EMC/30020FC15002 05.01.2015 The automatic Peak Power measurement capability of a spectrum analyzer was employed. Each port was measured separately at RBW 1MHz and VBW ≥ RBW" Total output power was calculated as a sum of ‘Peak output power Channel A + Peak output power Channel B 7 7 . . 5 5 . . T T e e s s t t S S e e t t u u p p Figure 4: Field strength of fundamental test setup 7 7 . . 6 6 . . C C a a l l c c u u l l a a t t e e d d R R e e s s u u l l t t s s f f o o r r b b o o t t h h p p o o r r t t s s Table 27: Settings for 23 dBi Antenna PTMP mode Frequency MHz BW MHz Port A dBm Port B dBm Total Power dBm Antenna Gain dBi EIRP Limit EIRP Pass/Fail 5730 5 9.9 9.11 12.53323829 23 35.53323829 36 Pass 5785 5 9.14 9.01 12.08578636 23 35.08578636 36 Pass 5845 5 9.87 9.55 12.7232466 23 35.7232466 36 Pass 5735 10 9.22 9.16 12.20040357 23 35.20040357 36 Pass 5785 10 9.71 9.24 12.49165487 23 35.49165487 36 Pass 5840 10 9.94 9.02 12.51461589 23 35.51461589 36 Pass 5735 20 9.71 9.70 12.71530283 23 35.71530283 36 Pass 5785 20 9.62 9.53 12.58553309 23 35.58553309 36 Pass 5840 20 9.12 8.97 12.05594753 23 35.05594753 36 Pass 5745 40 9.46 8.84 12.1713545 23 35.1713545 36 Pass 5785 40 9.56 9.05 12.32278194 23 35.32278194 36 Pass 5830 40 9.71 9.06 12.40744915 23 35.40744915 36 Pass WipAir 8000 5X FCC TX 15.247-Part 1 46/116 EMC/30020FC15002 05.01.2015 Table 28: Settings for 28.5 dBi Antenna PTMP mode Frequency MHz BW MHz Port A dBm Port B dBm Total Power dBm Antenna Gain dBi EIRP Limit EIRP Pass/Fail 5730 5 3.34 3.07 6.217397849 28.5 34.71739785 36 Pass 5785 5 3.14 3.09 6.125371912 28.5 34.62537191 36 Pass 5845 5 3.55 3.26 6.4177201 28.5 34.9177201 36 Pass 5735 10 3.48 3.34 6.420864066 28.5 34.92086407 36 Pass 5785 10 3.86 3.57 6.7277201 28.5 35.2277201 36 Pass 5840 10 3.56 3.28 6.432556099 28.5 34.9325561 36 Pass 5735 20 3.41 3.01 6.2249035 28.5 34.7249035 36 Pass 5785 20 3.54 3.49 6.525371912 28.5 35.02537191 36 Pass 5840 20 3.30 3.10 6.211451147 28.5 34.71145115 36 Pass 5745 40 3.91 3.48 6.710619634 28.5 35.21061963 36 Pass 5785 40 3.61 3.58 6.605325861 28.5 35.10532586 36 Pass 5830 40 3.75 3.70 6.735371912 28.5 35.23537191 36 Pass WipAir 8000 5X FCC TX 15.247-Part 1 47/116 EMC/30020FC15002 05.01.2015 PTMP Power for 23dBi Antenna/ 1 PTMP Power for 23dBi Antenna/ 2 WipAir 8000 5X FCC TX 15.247-Part 1 48/116 EMC/30020FC15002 05.01.2015 PTMP Power for 23dBi Antenna/ 3 PTMP Power for 23dBi Antenna/ 4 WipAir 8000 5X FCC TX 15.247-Part 1 49/116 EMC/30020FC15002 05.01.2015 PTMP Power for 23dBi Antenna/ 5 PTMP Power for 23dBi Antenna/ 6 WipAir 8000 5X FCC TX 15.247-Part 1 50/116 EMC/30020FC15002 05.01.2015 PTMP Power for 23dBi Antenna/ 7 PTMP Power for 23dBi Antenna/ 8 WipAir 8000 5X FCC TX 15.247-Part 1 51/116 EMC/30020FC15002 05.01.2015 PTMP Power for 23dBi Antenna/ 9 PTMP Power for 23dBi Antenna/ 10 WipAir 8000 5X FCC TX 15.247-Part 1 52/116 EMC/30020FC15002 05.01.2015 PT…

Text truncated - open the document above for the full version.

Test Report

WipAir 8000 5X FCC TX 15.247-Part 1 77/116 EMC/30020FC15002 05.01.2015 dBm 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 SoftPlot Measurement Presentation Trace A Start: 26.5000 GHzStop: 40.0000 GHz Res BW : 1 MHzVid BW : 3 MHzSweep: 337.50 ms 1/8/2015 10:48:16 AME7405A Mkr Trace X-Axis Value Notes 1 1 Trace A 39.2913 GHz-30.64 dBm Plot Out of Band Conducted Emission/ 9 dBm 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 SoftPlot Measurement Presentation Trace A Start: 26.5000 GHzStop: 40.0000 GHz Res BW : 1 MHzVid BW : 3 MHzSweep: 337.50 ms 1/8/2015 11:04:21 AME7405A Mkr Trace X-Axis Value Notes 1 1 Trace A 38.7850 GHz-31.40 dBm Plot Out of Band Conducted Emission/ 10 WipAir 8000 5X FCC TX 15.247-Part 1 78/116 EMC/30020FC15002 05.01.2015 dBm 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 SoftPlot Measurement Presentation Trace A Start: 26.5000 GHzStop: 40.0000 GHz Res BW : 1 MHzVid BW : 3 MHzSweep: 337.50 ms 1/8/2015 11:06:46 AME7405A Mkr Trace X-Axis Value Notes 1 1 Trace A 39.6288 GHz-30.72 dBm Plot Out of Band Conducted Emission/ 11 Plot Out of Band Conducted Emission/ 12 WipAir 8000 5X FCC TX 15.247-Part 1 79/116 EMC/30020FC15002 05.01.2015 Plot Out of Band Conducted Emission/ 13 Plot Out of Band Conducted Emission/ 14 WipAir 8000 5X FCC TX 15.247-Part 1 80/116 EMC/30020FC15002 05.01.2015 Plot Out of Band Conducted Emission/ 15 Plot Out of Band Conducted Emission/ 16 WipAir 8000 5X FCC TX 15.247-Part 1 81/116 EMC/30020FC15002 05.01.2015 Plot Out of Band Conducted Emission/ 17 Plot Out of Band Conducted Emission/ 18 WipAir 8000 5X FCC TX 15.247-Part 1 82/116 EMC/30020FC15002 05.01.2015 Plot Out of Band Conducted Emission/ 19 dBm 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 SoftPlot Measurement Presentation Trace A Start: 26.5000 GHzStop: 40.0000 GHz Res BW : 1 MHzVid BW : 3 MHzSweep: 337.50 ms 1/8/2015 11:07:35 AME7405A Mkr Trace X-Axis Value Notes 1 1 Trace A 39.2575 GHz-31.61 dBm Plot Out of Band Conducted Emission/ 20 WipAir 8000 5X FCC TX 15.247-Part 1 83/116 EMC/30020FC15002 05.01.2015 dBm 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 SoftPlot Measurement Presentation Trace A Start: 26.5000 GHzStop: 40.0000 GHz Res BW : 1 MHzVid BW : 3 MHzSweep: 337.50 ms 1/8/2015 11:11:13 AME7405A Mkr Trace X-Axis Value Notes 1 1 Trace A 39.5613 GHz-31.58 dBm Plot Out of Band Conducted Emission/ 21 dBm 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 SoftPlot Measurement Presentation Trace A Start: 26.5000 GHzStop: 40.0000 GHz Res BW : 1 MHzVid BW : 3 MHzSweep: 337.50 ms 1/8/2015 11:13:17 AME7405A Mkr Trace X-Axis Value Notes 1 1 Trace A 27.2088 GHz-31.42 dBm Plot Out of Band Conducted Emission/ 22 WipAir 8000 5X FCC TX 15.247-Part 1 84/116 EMC/30020FC15002 05.01.2015 Plot Out of Band Conducted Emission/ 23 Plot Out of Band Conducted Emission/ 24 WipAir 8000 5X FCC TX 15.247-Part 1 85/116 EMC/30020FC15002 05.01.2015 Plot Out of Band Conducted Emission/ 25 Plot Out of Band Conducted Emission/ 26 WipAir 8000 5X FCC TX 15.247-Part 1 86/116 EMC/30020FC15002 05.01.2015 Plot Out of Band Conducted Emission/ 27 Plot Out of Band Conducted Emission/ 28 WipAir 8000 5X FCC TX 15.247-Part 1 87/116 EMC/30020FC15002 05.01.2015 Plot Out of Band Conducted Emission/ 29 Plot Out of Band Conducted Emission/ 30 WipAir 8000 5X FCC TX 15.247-Part 1 88/116 EMC/30020FC15002 05.01.2015 dBm 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 SoftPlot Measurement Presentation Trace A Start: 26.5000 GHzStop: 40.0000 GHz Res BW : 1 MHzVid BW : 3 MHzSweep: 337.50 ms 1/8/2015 11:15:43 AME7405A Mkr Trace X-Axis Value Notes 1 1 Trace A 39.8650 GHz-31.35 dBm Plot Out of Band Conducted Emission/ 31 dBm 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 SoftPlot Measurement Presentation Trace A Start: 26.5000 GHzStop: 40.0000 GHz Res BW : 1 MHzVid BW : 3 MHzSweep: 337.50 ms 1/8/2015 11:18:32 AME7405A Mkr Trace X-Axis Value Notes 1 1 Trace A 39.6288 GHz-31.81 dBm Plot Out of Band Conducted Emission/ 32 WipAir 8000 5X FCC TX 15.247-Part 1 89/116 EMC/30020FC15002 05.01.2015 dBm 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 SoftPlot Measurement Presentation Trace A Start: 26.5000 GHzStop: 40.0000 GHz Res BW : 1 MHzVid BW : 3 MHzSweep: 337.50 ms 1/8/2015 11:20:18 AME7405A Mkr Trace X-Axis Value Notes 1 1 Trace A 39.9663 GHz-30.97 dBm Plot Out of Band Conducted Emission/ 33 Plot Out of Band Conducted Emission/ 34 WipAir 8000 5X FCC TX 15.247-Part 1 90/116 EMC/30020FC15002 05.01.2015 Plot Out of Band Conducted Emission/ 35 Plot Out of Band Conducted Emission/ 36 WipAir 8000 5X FCC TX 15.247-Part 1 91/116 EMC/30020FC15002 05.01.2015 Plot Out of Band Conducted Emission/ 37 Plot Out of Band Conducted Emission/ 38 WipAir 8000 5X FCC TX 15.247-Part 1 92/116 EMC/30020FC15002 05.01.2015 Plot Out of Band Conducted Emission/ 39 Plot Out of Band Conducted Emission/ 40 WipAir 8000 5X FCC TX 15.247-Part 1 93/116 EMC/30020FC15002 05.01.2015 Plot Out of Band Conducted Emission/ 41 dBm 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 SoftPlot Measurement Presentation Trace A Start: 26.5000 GHzStop: 40.0000 GHz Res BW : 1 MHzVid BW : 3 MHzSweep: 337.50 ms 1/8/2015 11:27:03 AME7405A Mkr Trace X-Axis Value Notes 1 1 Trace A 38.9200 GHz-30.99 dBm Plot Out of Band Conducted Emission/ 42 WipAir 8000 5X FCC TX 15.247-Part 1 94/116 EMC/30020FC15002 05.01.2015 dBm 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 SoftPlot Measurement Presentation Trace A Start: 26.5000 GHzStop: 40.0000 GHz Res BW : 1 MHzVid BW : 3 MHzSweep: 337.50 ms 1/8/2015 11:24:59 AME7405A Mkr Trace X-Axis Value Notes 1 1 Trace A 38.9538 GHz-31.57 dBm Plot Out of Band Conducted Emission/ 43 dBm 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 SoftPlot Measurement Presentation Trace A Start: 26.5000 GHzStop: 40.0000 GHz Res BW : 1 MHzVid BW : 3 MHzSweep: 337.50 ms 1/8/2015 11:22:39 AME7405A Mkr Trace X-Axis Value Notes 1 1 Trace A 39.4600 GHz-31.38 dBm Plot Out of Band Conducted Emission/ 44 WipAir 8000 5X FCC TX 15.247-Part 1 95/116 EMC/30020FC15002 05.01.2015 Plot Out of Band Conducted Emission/ 45 Plot Out of Band Conducted Emission/ 46 WipAir 8000 5X FCC TX 15.247-Part 1 …

Text truncated - open the document above for the full version.

Test Report

WipAir 8000 5X FCC TX 15.247-Part 2 REV  DESCRIPTION SHEET EFFECTED DATE DRAWN CHECKED A 18.05.2015 M. Reuben S. Cohen B Revised tables 25.06.2015 M. Reuben S. Cohen Fonction/Title Name Signature Date Prepared by: Technical Writer M. Reuben 05.01.2015 Checked by: Test Engineer I. Arbitman 14.04.2015 Approved By: EMC Lab. Manager S. Cohen 19-May-15 1/203 EMC/30020FC15002 05.01.2015 WipAir 8000 5X FCC TX 15.247-Part 2 2/203 EMC/30020FC10049 04.03.2010 TABLE OF CONTENTS Para. No. Title Page. No. 1. ADMINISTRATIVE DATA ........................................................................................................ 8 2. GENERAL INFORMATION ....................................................................................................... 8 3. TEST SUMMARY AND SIGNATURES. ....................................................................................... 9 4. RADIATED EMISSION .......................................................................................................... 10 5. MAXIMUM PEAK POWER DENSITY TEST.............................................................................. 183 6. CONDUCTED EMISSION TEST ACCORDING TO 15.207.15.107 .............................................. 197 List of Figures Figure No. Title Page. No. Figure 1: Radiated Emission Test Configuration ............................................................................................. 11 Photograph for Radiated Emission Test Setup/ 1 ..............................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Amit Arazi(Application Engineer)
[email protected]+972 4902 7000Fax: +972 4999 0324

Technical Contact

WaveIPAmit Arazi
[email protected]972-4-8027000

1 Sky Street · Misgav · Israel

Non-Technical Contact

WaveIPEli Avivi
[email protected]972-4-8027000

Test Firm

Elbit Systems Land C41Tadiran Ltd.Samuel Cohen
[email protected]97235574476Fax: 97235575320

Technical Specifications

#Rule PartsFrequency RangePower Output
415C5.75 GHz - 5.83 GHz827.00 mW
Confidentiality
Long Term
Grant Notes
Power output listed is combined conducted peak power. The antennas and the device must be installed only for fixed, point-to-point or point-to-multipoint operations on outdoor permanent structures. Power reduction is implemented for point to multi-point communication as described in this filing. Professional installation is required. The antenna(s) must be installed to provide a separation distance of at least 2.5 m from all persons, and must not be co-located or operating in conjunction with other antennas or transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from WaveIP Ltd.

Point-to-Point & Point-to-Multipoint broadband wireless bridge - FCC ID QQ2-WA6049 - WaveIP Ltd.
QQ2-WA6049

Point-to-Point & Point-to-Multipoint broadband wireless bridge

Jul 23, 2012

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Point-to-Point & Point-to-Multipoint broadband wireless bridge - FCC ID QQ2-WA605X - WaveIP Ltd.
QQ2-WA605X

Point-to-Point & Point-to-Multipoint broadband wireless bridge

Jun 20, 2010

Equipment Class

DTS - Digital Transmission System
Outdoor Transmitter Unit - FCC ID QQ2-GAOFDM-700 - WaveIP Ltd.
QQ2-GAOFDM-700

Outdoor Transmitter Unit

Jul 24, 2006

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Indoor Transmitter Unit - FCC ID QQ2-GAOFDM700-RSU - WaveIP Ltd.
QQ2-GAOFDM700-RSU

Indoor Transmitter Unit

Jul 16, 2006

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Outdoor Transmitting Unit - FCC ID QQ2-GAOFDM58 - WaveIP Ltd.
QQ2-GAOFDM58

Outdoor Transmitting Unit

Apr 06, 2006

Equipment Class

DTS - Digital Transmission System