Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
January 2003 APREL Project No.: WAMB-NEPTUNE-WEX10-3957 Consulting * Research * Training * Certification Testing Since 1981 FCC ID: QRM-WEX-10-EXT Exhibit 9 User’s Manual ©Copyright 1998-2003 WaveCell International Corp. All Rights Reserved Version 1.5 Date: January 22, 2003 Neptune WEX-10 CDPD Modem User Guide “Global Solutions for a World on the Move” Neptune WEX-10 CDPD Modem User Guide ii Neptune WEX-10 CDPD Modem User Guide Corporate Headquarters: WaveCell International Corp. 111 Redpath Drive Ottawa, Ontario, Canada, K2G 6K4 Phone: (613) 860-7007 Fax: (613) 224-3153 Toll Free: 1-877-588-0288 Internet: www.wavecell.com E-mail: [email protected] Neptune WEX-10 CDPD Modem User Guide iii Copyright ©Copyright 1998-2003 WaveCell International Corp. All rights reserved. Information in this document is subject to change without notice. No part of this document may be copied, photocopied, reproduced, translated into any language, microfilmed, stored in a retrieval system, transmitted in any form or by any means or otherwise duplicated on any medium without written consent of WaveCell International Corp. Use of the software programs described herein and this documentation is subject to the WaveCell International Corp. License Agreement. Trademarks WaveCell is a registered trademark of WaveCell International Corp. All product names referenced herein are trademarks of their respective companies. Liability In no event will WaveCell International Corp. be liable for any damage, including loss of data or profits, cost of cover, or other incidental, consequential or indirect damages arising from the installation maintenance, use, performance, failure or interruption of WaveCell products, whatever the cause and on any theory of liability. This limitation will apply even if WaveCell International Corp. has been advised of such possibility of such damage. Neptune WEX-10 CDPD Modem User Guide iv Table of Contents 1.INTRODUCTION.................................................................................................................................. 1 2.PHYSICAL SPECIFICATIONS.......................................................................................................... 1 2.1.SIZE & CONSTRUCTION...................................................................................................... 1 2.2.FRONT AND REAR MODEM VIEWS WITH PANEL DESCRIPTIONS......................................... 1 2.3.LED FUNCTIONAL DESCRIPTION........................................................................................ 1 2.3.1.Red – Power / Fault LED.......................................................................................................... 1 2.3.2.Green – Transmit / Receive LED............................................................................................... 2 3.HOST INTERFACE SPECIFICATIONS........................................................................................... 2 3.1.RS232 INTERFACE.............................................................................................................. 2 3.2.RF ANTENNA CONNECTOR................................................................................................. 2 4.RADIO SPECIFICATIONS................................................................................................................. 2 4.1.RF POWER CLASS............................................................................................................... 2 4.2.AIRLINK DATA RATE.......................................................................................................... 2 4.3.MODE FREQUENCY RANGE................................................................................................ 2 4.4.DUPLEX MODE.................................................................................................................... 3 4.5.WIRELESS PROTOCOLS....................................................................................................... 3 4.6.COMMUNICATION PROTOCOLS.......................................................................................... 3 5.POWER SPECIFICATIONS AND REQUIREMENTS.................................................................... 3 6.RADIO ANTENNA................................................................................................................................3 6.1.ANTENNA TYPE................................................................................................................... 3 6.2.RADIO ANTENNA LOCATION.............................................................................................. 3 7.GENERAL SAFETY............................................................................................................................. 4 8.CHOOSING THE RIGHT PLACE TO MOUNT THE NEPTUNE CDPD MODEM.................... 4 9.MAKING THE CONNECTIONS – WIRING.................................................................................... 4 9.1.APPLYING POWER............................................................................................................... 4 9.2.POWER CABLE.................................................................................................................... 4 9.3.SERIAL RS232 CONNECTIONS............................................................................................ 4 9.3.1.RS232 Connector Pin Assignment............................................................................................. 5 9.4.RADIO ANTENNA CONNECTION.......................................................................................... 5 10.CONFIGURING THE MODEM..................................................................................................... 5 10.1.TERMINAL EMULATOR CONFIGURATION........................................................................... 5 10.2.CONFIGURING IP ADDRESS................................................................................................. 5 10.3.CONFIGU…
Text truncated - open the document above for the full version.
January 2003 APREL Project No.: WAMB-NEPTUNE-WEX10-3957 Consulting * Research * Training * Certification Testing Since 1981 FCC ID: QRM-WEX-10-EXT Exhibit 10 Attestation Statements FCC Part 15, Subpart B Class B Certificate of Conformity FCC Part 2 & 22 Statement of Compliance January 2003 APREL Project No.: WAMB-NEPTUNE-WEX10-3957 Consulting * Research * Training * Certification Testing Since 1981 Certificate of Compliance FCC ID: QRM-WEX-10-EXT PRODUCT: Trip Reporter MODEL: Neptune WEX-10-EXT MANUFACTURER: WaveCell International Corp. We certify that the pertinent tests have been performed on the above-described equipment and that this equipment conforms to the applicable requirements of FCC Parts 2, 15 and 22. See Exhibit 2, Engineering Reports Jayanta (Jay) K. Sarkar Technical Director, Standards and Certification APREL Laboratories
January 2003 APREL Project No.: WAMB-NEPTUNE-WEX10-3957 Consulting * Research * Training * Certification Testing Since 1981 FCC ID: QRM-WEX-10-EXT Table of Contents List of Exhibits Submitted E E X X H H I I B B I I T T 1 1 : : C C O O V V E E R R L L E E T T T T E E R R S S a) Application overview b) Equipment Identification c) Authorization Letter /Agent Designated (Jay Sarkar) d) Request for confidentiality Exhibit 2:Engineering Reports (Test Reports) a) ERP (2.1046) b) Radiated Spurious Emissions (2.1053) c) Bandwidth (2.1049) Modulation Characteristics (2.1047) d) Spurious Emissions at Antenna Terminal (2.1051) e) Frequency Stability (2.1055) Exhibit 3: Operational/Technical Description (Confidential) Exhibit 4: ID Label/Location Exhibit 5:External Photographs of the Equipment Internal Photographs of the equipment Exhibit 6:Block Diagram (Confidential) Exhibit 7: Schematic Diagram (Confidential) Exhibit 8:Parts List (Confidential), Tune–up Procedure Exhibit 9:User’s Manual Exhibit 10:a) Attestation Statement: FCC Part 15 Declaration of Conformance (DoC) certificate b) Attestation Statement: the equipment complies with Parts 2 & 22
January 2003 APREL Project No.: WAMB-NEPTUNE-WEX10-3957 Consulting * Research * Training * Certification Testing Since 1981 FCC ID: QRM-WEX-10-EXT Exhibit 1 a) Application overview b) Equipment: c) Authorization Letter /Agent Designated (Jay Sarkar) d) Request for confidentiality January 2003 APREL Project No.: WAMB-NEPTUNE-WEX10-3957 Consulting * Research * Training * Certification Testing Since 1981 EXHIBIT 1b Equipment Identification FCC ID: QRM-WEX-10-EXT MANUFACTURER: WaveCell International Corp. FCC ID:QRM-WEX-10_EXT Product: WaveCell Neptune CDPD Modem Model: Neptune WEX-10 CDPD Modem EUT Type:Licensed Non-Broadcast Station Transmitter (TNB) TX Frequency: 824-849 MHz Measured ERP: 0.458 W Emission Designators:28K8FXW WaveCell International Corp. 111 Redpath Drive www.wavecell.com Ottawa, Ontario, K2G 6K4 Canada Page 1 of 1 Toll free in Canada and US: 1-877-588-0288 Phone: (613) 860-7007 Fax: (613) 823-4433 November 29, 2002 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia MD 21406 RE: FCC ID: QRM-WEX-10-EXT To Whom It May Concern: We the undersigned, hereby authorize Jay Sarkar of APREL Laboratories, to act on our behalf in all matters relating to equipment authorization, including the signing of all documents relating to these matters . Any and all acts carried out by APREL Laboratories on our behalf shall have the same effect as acts of our own. We also certify that no party to this application is subject to denial of benefits, pursuant to Section 301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). WaveCell International Corp. 111 Redpath Drive www.wavecell.com Ottawa, Ontario, K2G 6K4 Canada Toll free in Canada and US: 1-877-588-0288 Phone: (613) 860-7007 Fax: (613) 823-4433 November 29, 2002 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia MD 21406 In regards to: WaveCell International Corp. FCC ID:QRM-WEX-10-EXT Product: Neptune WEX-10 Request for Confidentiality Gentlemen: In accordance with 0.459 of CFR 47, Wavecell International hereby requests confidentiality of the Block Diagram , Schematic Diagrams Technical Description and Parts List for the attached test report. These documents contain detailed system and equipment description and related information about the product which Wavecell International Corporation considers to be proprietary, confidential, and a custom design and, otherwise, would not release to the general public. Since this design is a basis from which future technological products will evolve, Wavecell International Corporation considers this information would be of benefit to its competitors, and that the disclosure of the information in these documents would give competitors an unfair advantage in the market.
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION Certification Attention: Owen Thistle, Director of Program Management NOT TRANSFERABLE EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. Novatel Wireless Technologies Ltd 6715 8th Street N.E., Suite 200 Calgary, Alberta Canada Date of Grant: 04/14/1999 Application Dated: 12/09/1998 FCC IDENTIFIER NBZNRM-6832 Name of Grantee Novatel Wireless Technologies Ltd Equipment Class: Licensed Non-Broadcast Station Transmitter Notes: CDPD Module Grant Notes FCC Rule Parts Frequency Range (MHZ) Output Watts Frequency Tolerance Emission Designator 22.901(d) 824 - 849 0.6 2.5 PM28K8FXW Power output listed us conducted power at the antenna terminals of the transmitter. Unit may be used with indoor antennas having gain not exceeding 2.15 dBi or with outdoor antennas yielding 1.5 W ERP total system output to satisfy MPE limits. The transmitter is approved for integration into OEM products that meet RF exposure requirements for mobile transmitting devices only. The final product must operate at 20 cm or more from all persons in order to satisfy MPE criteria. A warning label identical to that in the installation manual must be displayed on the final OEM product and be visible by all persons exposed to the transmitter to satisfy MPE compliance. Mail To: Morton Flom, President M. Flom Associates Inc 3356 N San Marcos Place, Suite 107 Chandler, AZ 85224-1571 9812168315842002
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION Certification Attention: Owen Thistle, Director of Program Management NOT TRANSFERABLE EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. Novatel Wireless Technologies Ltd 6715 8th Street N.E., Suite 200 Calgary, Alberta Canada Date of Grant: 06/25/2001 Application Dated: 04/10/2000 FCC IDENTIFIER NBZNRM-6832 Name of Grantee Novatel Wireless Technologies Ltd Equipment Class: Licensed Non-Broadcast Station Transmitter Notes: Minstrel III (CDPD Radio Modem) Grant Notes FCC Rule Parts Frequency Range (MHZ) Output Watts Frequency Tolerance Emission Designator 22.901(d) 824 - 849 0.6 2.5 PM28K8FXW Power output listed is conducted power at the antenna terminals of the transmitter. Unit may be used with indoor antennas having gain not exceeding 2.15 dBi or with outdoor antennas yielding 1.5 W ERP total system output to satisfy MPE limits. The transmitter is approved for integration into OEM products that meet RF exposure requirements for mobile transmitting devices only. The final product must operate at 20 cm or more from all persons in order to satisfy MPE criteria. A warning label identical to that in the installation manual must be displayed on the final OEM product and be visible by all persons exposed to the transmitter to satisfy MPE compliance. Original date of Grant is 4/14/99. This Permissive Change adds two specific hand-held PDAs to the original filing, for operating as mobile transmitting devices. Both devices were evaluated for SAR compliance for hand-held use. End-users must be informed of the operating requirements. The highest reported SAR value is 1.19 W/kg. Mail To: EA97295
January 2003 APREL Project No.: WAMB-NEPTUNE-WEX10-3957 Consulting * Research * Training * Certification Testing Since 1981 FCC ID: QRM-WEX-10-EXT Exhibit 5A Photographs of the Equipment External Photos
January 2003 APREL Project No.: WAMB-NEPTUNE-WEX10-3957 Consulting * Research * Training * Certification Testing Since 1981 FCC ID: QRM-WEX-10-EXT Exhibit 4 FCC ID Label/Location This label will be attached to the underside of the unit, as shown with a preliminary design in the following picture. Neptune WEX-10 CDPD Modem www.wavecell.com FCC ID: QRM-WEX-10-EXT IC: 4497A-WEX10EXT This Device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device doesn’t cause harmful interference. All Persons must be at least 20cm from the antenna when transmitter operating to meet FCC RF exposure requirements. Made in / Fait au / Hecho en Canada
January 2003 APREL Project No.: WAMB-NEPTUNE-WEX10-3957 Consulting * Research * Training * Certification Testing Since 1981 FCC ID: QRM-WEX-10-EXT Exhibit 5B Photographs of the Equipment Internal Photos
51 Spectrum Way Tel (613) 820-2730 Email: [email protected] Nepean, Ontario Fax (613) 820-4161 HTTP://www.aprel.com Canada K2R 1E6 Environmental Evaluation of RF Exposure MAXIMUM PERMISSIBLE EXPOSURE (MPE) ESTIMATION Prepared for Federal Communications Commission FCC ID: QRM-WEX-10-EXT Introduction Purpose of the Report This technical report is a detailed environmental analysis of the radio frequency exposure expected from use of the Neptune WEX-10 CDPD Wireless Modem, manufactured by WaveCell International Corporation, FCC ID: QRM-WEX-10-EXT frequency range of 824-849 MHz. The following analysis demonstrate that the product Neptune WEX-10 CDPD Wireless Modem is in compliance with the requirements for maximum permissible exposure (MPE) to radio frequency exposure as defined in the FCC Rules, 47 CFR 2. 1091, as amended and the limits as given in the FCC Rules, 47 CFR 2. 1.1310, table 1, Radio Frequency radiation exposure limits. Limits The criteria listed in the following table are used to evaluate the environmental impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b). LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm²) 300-1500 ... ... F/300 1500-100,000 ... ... 5 300-1500 ... ... F/1500 1500-100,000 ... ... 1.0 F=frequency of interest Classification of Device/Applicability of Rules Mobile devices The Neptune Wex-10 CDPD Wireless Modem is properly defined as a mobile device per 47 CFR 2.1091 (b), which states that “mobile devices are defined as transmitters designed to be used in other than fixed locations and to generally be used in such a way that a separation distance of at least 20 centimeters is normally maintained between radiating antennas and the body of the user or nearby persons.” Neptune Wex-10 CDPD Wireless Modem is designed to be used in mobile applications. Mounting inside the passenger compartment or trunk is acceptable. The recommended location of the antenna 51 Spectrum Way Tel (613) 820-2730 Email: [email protected] Nepean, Ontario Fax (613) 820-4161 HTTP://www.aprel.com Canada K2R 1E6 is on the car roof or a flat ground plane, at least 10 cm away from any uneven surface. When choosing a location for the antenna, consideration is given to metal obstructions. For applications for the Neptune Wex-10 CDPD Wireless modem, typically at least a separation distance of 20 centimeters is maintained between the radiating antennas and the body of the user or nearby person in order to meet the FCC exposure guidelines while the device is in operation. A statement is included in the User’s Manual recommending maintaining a separation distance of 20 centimeter. However, this statement does not in anyway reflects that proximity of less than 20 centimeters are hazardous. The recommendation of a 20-cm separation distance ensures that a well- defined margin with respect to the maximum permissible exposure as estimated using a theoretical prediction model is maintained. Operation mode The device is a CDPD wireless modem. Maximum exposure calculation is based on 100% duty factor to calculate for the worst case condition. Estimation/Calculation method of Power Density(S): Calculations can be made to predict RF Field strength and power density levels around typical RF Sources. For example, in the case of a single radiating antenna, a prediction for power density in the far field of the antenna can be made by use of the general equations below. These equations are generally accurate in the far field of an antenna but will over-predict power density in the near field, where they could be used for making a worst case or conservative prediction. S= PG/4 πR 2 Where: S= power density, mW/cm² P= power input to the antenna, mW G= power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna, cm or: S=EIRP/ 4 πR 2 Where: EIRP = equivalent (or effective) isotropically radiated power It can be seen from the above that the “worst case” or the max. MPE limit for mobile devices can be estimated according to the power density (S) produced by an isotropic source with radiated output power equivalent to that transmitted by the device as discussed above (OET Bulletin 65). In this case the operating power is expressed in terms of “ERP” (effective radiated power) instead of EIRP. As such, it is necessary to know the ERP of the source. The ERP was measured at APREL Laboratories, following the substitution method as described in this text and then converted to EIRP for use in the above equation. Determination of Effective Radiated Power (ERP) 51 Spectrum Way Tel (613) 820-2730 Email: [email protected] Nepean, Ontario Fax (613) 820-4161 HTTP://www.aprel.com Canada K2R 1E6 The radiated RF power measurement was carried out at APREL Laboratory’s open area test site (OATS). This open area test site is calibrated to ANSI C63.4 document and a description of the measurement facility is on file with the Federal Communications Commission and is in compliance with the requirement of Section 2.948 of the Commissions rules and regulations. (FCC File No.: 90416) The Wireless Module was configured to operate at maximum power. The equipment under test was placed on a turntable positioned 3 m away from the calibrated receiving antenna, which in turn was connected to the spectrum analyzer. For each transmitter frequency, the received signal was maximized by rotating the turntable and adjusting the height of the receiving antenna. To obtain the actual ERP, the DUI was replaced by a vertically polarised half-wave dipole antenna resonant to that frequency and fed by a RF power amplifier and signal generator. The center of the dipole antenna was placed precisely in the same location as the DUI. It was ensured that the orientation of the rotating table and the height of the receiving antenna were unmoved. The signal generator level was ad…
Text truncated - open the document above for the full version.
January 2003 APREL Project No.: WAMB-NEPTUNE-WEX10-3957 Consulting * Research * Training * Certification Testing Since 1981 FCC ID: QRM-WEX-10-EXT Exhibit 2a Engineering Report on ERP (2.1046) Assessment of Compliance for Measurement of Effective Radiated Power (ERP) in accordance with the FCC Rules & Regulations Part 2.1046 and 22 WaveCell Neptune CDPD Modem Neptune Wex-10 CDPD Modem WaveCell International Corp. 51 Spectrum Way Nepean ON K2R 1E6 Tel: (613) 820-2730 Fax: (613) 820-4161 email: [email protected] January 2003 APREL Project No.: WAMB-NEPTUNE-WEX10-3957 E E n n g g i i n n e e e e r r i i n n g g R R e e p p o o r r t t Subject: Measurement of Effective Radiated Power (ERP) in accordance with the FCC Rules & Regulations Part 2.1046 and 22 FCC ID: QRM-WEX-10-EXT Equipment: WaveCell Neptune CDPD Modem Model: Neptune WEX-10 CDPD Modem Client: WaveCell International Corp. 111 Redpath Dr. Ottawa, Ontario K2G 6K4 CANADA Project #: WAMB-NEPTUNE-WEX10-3957 Prepared By:APREL Laboratories, Regulatory Compliance Division 51 Spectrum Way Nepean, Ontario January 2003 Page 3 APREL Project No WAMB-NEPTUNE-WEX10-3957 This report shall not be reproduced, except in full, without the express written approval of APREL Laboratories Consulting * Research * Training * Certification Testing Since 1981 FCC ID:QRM-WEX-10-EXT Applicant:WaveCell International Corp. Equipment:WaveCell Neptune CDPD Modem Model:Neptune WEX-10 CDPD Modem Standard:FCC Rules and Regulations Part 2.1046 and 22 ENGINEERING SUMMARY This report contains the results of the Effective Radiated Power (ERP) measurement performed on a WaveCell, model Neptune Wex-10 CDPD Wirelesss Modem with a Smarteq Wireless AB Minimag Dual Band 800/1900 MHz - 0 dBd Antenna. The measurements were carried out in accordance with the FCC Rules and Regulations Part 2.1046 and 22. The product was evaluated for ERP when it was set at the maximum power level. Neptune WEX-10 CDPD Modem was tested for ERP at high, middle and low channel frequencies. Maximum ERP was obtained at channel No.799 with the frequency being 848.97 MHz. The test data is presented in this report under the section: Test Results. The maximum measured ERP was 0.458 W (26.61 dBm). Test Configuration: The test was carried out with the antenna connected to the modem by 2.6 m long RG174 cable provided with and permanently attached to the antenna. The antenna was mounted on a ground plane that was placed on the table with the modem positioned under the ground plane, simulating the same conditions when the antenna is mounted on the car roof or a flat ground plane at least 10 cm away from any uneven surface. (The results presented in this report relate only to the sample tested.) Summary of the Results Test DescriptionPage No. Test Set-up Figure No. Pass/Fail RF Power Output as Radiated Ref. Paragraph 2.1046 and 2281Passed January 2003 Page 4 APREL Project No WAMB-NEPTUNE-WEX10-3957 This report shall not be reproduced, except in full, without the express written approval of APREL Laboratories Consulting * Research * Training * Certification Testing Since 1981 INTRODUCTION General This report describes the results of the effective radiated power (ERP) measurement performed on a WaveCell Neptune wireless CDPD Modem , model Neptune Wex-10 CDPD Modem. Test Facility The tests were performed for WaveCell International Corp. by APREL Laboratories at APREL’s EMI facility located in Nepean, Ontario, Canada. The laboratory operates an (3m and 10m) Open Area Test Site (OATS). The measurement facility is calibrated in accordance with ANSI C63.4-1992. A description of the measurement facility in accordance with the radiated and AC line conducted test site criteria per ANSI C63.4-1992 is on file with the Federal Communications Commission and is in compliance with the requirements of Section 2.948 of the Commissions rules and regulations. APREL’s registration number is: 90416 APREL is accredited by Standard Council of Canada. APREL is also accredited by Industry Canada. Standard The evaluation and analysis were conducted in accordance with FCC Rules and Regulations Parts 2.1046 and the appropriate limits (22). Test Equipment The test equipment used during the evaluation is listed in Appendix A. Environmental Conditions Measurements were conducted in open area test site. Temperature:18 ± 2 °C Relative Humidity:30 - 50 % Air Pressure:101 kPa ± 3 Personnel: The equipment was tested by Roman Kuleba, EMC Engineer and the report was written by Jay Sarkar, Technical Director, Standards and Certification. January 2003 Page 5 APREL Project No WAMB-NEPTUNE-WEX10-3957 This report shall not be reproduced, except in full, without the express written approval of APREL Laboratories Consulting * Research * Training * Certification Testing Since 1981 FCC SUBMISSION INFORMATION FCC ID:QRM-WEX-10-EXT Equipment (type):WaveCell Neptune wireless CDPD Modem As Marketed Model:Neptune Wex-10 CDPD Modem For:Certification Applicant:WaveCell International Corp. 111 Redpath Dr. Ottawa, Ontario K2G 6K4 CANADA Manufacturer: WaveCell International Corp. 111 Redpath Dr. Ottawa, Ontario K2G 6K4 CANADA Evaluated by:APREL Laboratories 51 Spectrum Way Nepean, Ontario Canada K2R 1E6 January 2003 Page 6 APREL Project No WAMB-NEPTUNE-WEX10-3957 This report shall not be reproduced, except in full, without the express written approval of APREL Laboratories Consulting * Research * Training * Certification Testing Since 1981 MANUFACTURER’S DATA FCC ID No:QRM-WEX-10-EXT Equipment Type:WaveCell Neptune CDPD Modem Model:Neptune Wex-10 CDPD Modem Reference:FCC Rules and Regulations Parts 2 and Part 22 Manufacturer:WaveCell International Corp. Development Stage of Unit:Production GENERAL SPECIFICATIONS 1.Frequency Range:824-849 MHz 2. Measured ERP:0.458 W (26.61 dBm) 3. Emission Designator: Per 47 CFR § 2.201 and §2.202 28K8FXW 4. Antenna Impedance:50 Ohms January 2003 Page 7 APREL Project No WAMB-NEPTUNE-WEX10-3957 This report shall not be reproduced…
Text truncated - open the document above for the full version.
January 2003 APREL Project No.: WAMB-NEPTUNE-WEX10-3957 Consulting * Research * Training * Certification Testing Since 1981 FCC ID: QRM-WEX-10-EXT Exhibit 2b Engineering Report on Radiated Spurious Emissions (2.1053) Assessment of Compliance for Measurement of Field Strength of Spurious Radiation in accordance with the FCC Rules & Regulations Part 2.1053 and 22 WaveCell Neptune CDPD Modem Neptune WEX-10 CDPD Modem WaveCell International Corp. 51 Spectrum Way Nepean ON K2R 1E6 Tel: (613) 820-2730 Fax: (613) 820-4161 email: [email protected] January 2003 APREL Project No.: WAMB-NEPTUNE-WEX10-3957 E E n n g g i i n n e e e e r r i i n n g g R R e e p p o o r r t t Subject: Measurement of Field Strength of Spurious Radiation in accordance with the FCC Rules & Regulations Part 2.1053 and 22 FCC ID: QRM-WEX-10-EXT Equipment: WaveCell Neptune CDPD Modem Model: Neptune Wex-10 CDPD Modem Client:WaveCell International Corp. 111 Redpath Dr. Ottawa, Ontario, K2G 6K4 CANADA Project #: WAMB-NEPTUNE WEX10-3957 Prepared By: APREL Laboratories, Regulatory Compliance Division 51 Spectrum Way Nepean, Ontario January 2003 Page 3 APREL Project No: WAMB-NEPTUNE-WEX10-3957 This report shall not be reproduced, except in full, without the express written approval of APREL Laboratories Consulting * Research * Training * Certification Testing Since 1981 FCC ID:QRM-WEX-10-EXT Applicant:WaveCell International Corp. Equipment: WaveCell Neptune CDPD Modem Model:Neptune Wex-10 CDPD Modem Standard:FCC Rules and Regulations Part 2.1053 and 22.917(e) ENGINEERING SUMMARY This report contains the results of Field Strength of Spurious Radiation measurement performed on a WaveCell, for model Neptune Wex-10 CDPD Wireless Modem with a Smarteq wireless AB Minimag Dual Band 800/1900 MHz - 0 dBd antenna. The measurement was carried out in accordance with the FCC Rules and Regulations Part 2.1053 and 22.917(e) using 1) Direct Method and 2) Substitution Method, both as radiated. Neptune Wex-10 CDPD Mode was tested at high, middle and low channel frequencies. Test Configuration: The test was performed with the antenna connected to the modem by 2.6 m long RG174 cable provided with and permanently attached to the antenna. The antenna was mounted on a ground plane that was placed on the table with the modem positioned under the ground plane, simulating the same conditions when the antenna is mounted on the car roof or a flat ground plane at least 10 cm away from any uneven surface. The results presented in this report relate only to the sample tested. Table one Summary of the Results Test DescriptionPage No. Test Set-up Figure No.Pass/Fail Field Strength of Spurious Radiation Ref. Pa…
Text truncated - open the document above for the full version.
51 Spectrum Way · Nepean Ontario · Canada
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 22 | 824 MHz - 849 MHz | 458.00 mW | 28K8FXW | 2.5000000000 ppm |