FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Gentherm Inc./
  3. QYA500-1272

QYA500-1272Remote Control Unit

Gentherm Inc.
Remote Control Unit - FCC ID QYA500-1272 - Gentherm Inc.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 14, 2013
Application Purpose
Original Equipment
Date of Application
Mar 14, 2013
Equipment Note
Remote Control Unit
Frequency Range
2465.00000000 - 2465.00000000
Company
Gentherm Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User GuideClimate Control Sleep System USER GUIDE CopyRIGht © 2012 GENthERM Table of ConTenTs ADVISORY......................................... INSTALLATION............................... OPERATION..................................... PROGRAMMING............................ TROUBLESHOOTING.................. WARRANTY..................................... 2 4 8 14 16 17 1 Welcome! Congratulations on choosing the innovative Climate Control Sleep System. Get ready to enjoy personalized climate control that will improve your overall comfort and sleep quality. If you have any questions while setting up or using your bed, please visit www.gentherm.com/ccss USER GUIDE CopyRIGht © 2012 GENthERM advisory PLEASE READ THE FOLLOWING INFORMATION CAREFULLY BEFORE USING THIS PRODUCT. PLEASE SAvE THESE INSTRUCTIONS. As with all electrical products, the misuse of this product or failure to properly follow the instructions may cause overheating, fire, or personal injury. Be sure the main control unit is used only on an AC supply current circuit of 110/220 volts. Do not use with an extension cord. It is recommended to use a surge protection device (not included) between the main control unit and the outlet. Failure to use a surge protector could cause product malfunction in the event of an electrical surge. Do not use with damaged cords. Do not remove, trap, fold, cross or pinch any wires or cords. The main control unit should be placed on a dry, firm floor, in a well ventilated place, free from surrounding fabric. Clearance of at least one (1) foot should be left on all sides. Do not use the heat/cool feature of this bed with an infant, a child, an incapacitated person, a paraplegic, a quadriplegic, or if you are insensitive to heat or cool. Keep all pets away from the main control unit and wiring. 1. 2. 3. 4. 5. 2 Always unplug the MCU from the electrical outlet before cleaning. Keep the cord away from the heated surfaces. Do not use outdoors. • • • IMPORTANT SAFETY INSTRUCTIONS DANGER — To reduce the risk of electric shock: USER GUIDE CopyRIGht © 2012 GENthERM 3 • Reorient or locate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. • The Climate Control Sleep System utilizes 110/220 V, 50/60Hz, 2A • Manufactured by Gentherm • Electronics made in China • For household/residential use only. FCC Compliance The remote device complies with part 15 of the FCC rules. Opera- tion is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must not accept any interference received, including interference that may cause unde- sired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference with a residential installation. This equipment generates, uses and can radiate frequency energy and, if not installed and used in accordance with these instructions, may cause harmful interference to radio communications. There is no guarantee that interference will not occur in a particular situation. If this equipment does interfere with TV or radio reception, which can be determined by turning the device on and then off, the user is encouraged to try to correct the interference by one or more of the following measures: Modifications made to the product, unless expressly approved by Gentherm, could void the user’s authority to operate the equipment. CAUTION : Exposure to Radio Frequency Radiation. Antenna shall be mounted in such a manner to minimize the potential for human contact during normal operation. The antenna should not be contacted during operation to avoid the possibility of exceeding the FCC radio frequency exposure limit. The Climate Control Sleep System conforms to UL Standard 962 test requirements. USER GUIDE CopyRIGht © 2012 GENthERM 4 insTallaTion Before You Begin: Check the contents of the electronic kit box. It should include: Decide on a location for your new bed. Consider the following: Keep the master control unit away from areas that might become damp or wet, such as an open window. Do not cover the master control unit; ensure that it is in a well ventilated area. Do not store any items under the bed; a well-ventilated space under the bed is necessary for proper functioning of the climate control system. • • • BEDDING CONSIDERATIONS Main Control Unit (MCU) Plastic tubes for air flow (4) Remotes (2) Power Cord Instruction manual Warranty registration card Four (4) AAA batteries USER GUIDE CopyRIGht © 2012 GENthERM 5 BED SKIRT MODIFICATION (if used) • Do not cover interlay with fitted sheet. • Do not use a mattress pad on your mattress as it will block air flow to the surface of the bed. BEDDING CONSIDERATIONS USER GUIDE COPYRIGHT © 2012 GENTHERM 6 Note: • Cords exit the interlay from the head of the bed. • Queen interlay cords exit from the outside edge of the interlay from the head end of the bed. • It is recommended that a surge protection device (not included) is used between the MCU and the outlet. • Prior to installation of the mattress, add the four (4) posts and turn the MCU to high heat (refer to OPERATION section) and verify that there is air fl ow coming from the posts. If there is no airfl ow, verify all connections are made, then, refer to the trouble- shooting section. Extension (optional) BED SET UP USER GUIDE CopyRIGht © 2012 GENthERM • There are eight (8) holes in the underside of the mattress with eight plastic inserts covering each hole. Four (4) of these holes are designed to fit over the posts of the interlay. The extra set of holes on the mattress is to account for rotation of the mattress. • Take care when lifting the mattress. It is necessary…

Text truncated - open the document above for the full version.

Cover Letter(s)

Gentherm Inc. Date: February 27, 2013 EMCCert DR. RAŠEK GmbH Stoernhofer Berg 15 91364 Unterleinleiter GERMANY This authorization is valid until further written notice from the applicant. Sincerely Yours, _______________________________________________ Company : Gentherm Inc. Applicant : Robert Vidojevski e-mail : [email protected]

External Photos

Page 1 of 6 Report No. : E132R-033 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) Page 2 of 6 Report No. : E132R-033 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) Page 3 of 6 Report No. : E132R-033 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) Page 4 of 6 Report No. : E132R-033 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) Page 5 of 6 Report No. : E132R-033 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) Page 6 of 6 Report No. : E132R-033 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)

ID Label/Location Info

Page 1 of 1 Report No.:E132R-033 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) IDENTIFICATION LABEL: PROPOSED FCC ID LABEL The FCC ID shall be permanently affixed to the bottom side of the equipment FCC ID AREA This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operations. Made in Korea FCC ID : QYA500-1272

Internal Photos

Page 1 of 3 Report No. : E132R-033 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) Page 2 of 3 Report No. : E132R-033 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) Page 3 of 3 Report No. : E132R-033 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)

Test Report

FCC ID. : QYA500-1272 Page 1 of 25 Report No.: E132R-033 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) ELECTROMAGNETIC EMISSION COMPLIANCE REPORT FOR LOW-POWER, NON-LICENSED TRANSMITTER Test Report No. : E132R-033 AGR No. : A12NA-144 Applicant : Gentherm Inc. Address : 21680 Haggerty Rd., Northville, MI 48167 Manufacturer : Season Components Co., Ltd. Address : No. 5, Jun Da Zhong Lu, DongKeng, Dongguan, Guangdong 523451 China Type of Equipment : Remote Control Unit FCC ID. : QYA500-1272 Model Name : REMOTE2.0 Serial number : N/A Total page of Report : 25 pages (including this page) Date of Incoming : January 10, 2013 Date of issue : February 20, 2013 SUMMARY The equipment complies with the regulation; FCC Part 15 Subpart C Section 15.247. This test report only contains the result of a single test of the sample supplied for the examination. It is not a generally valid assessment of the features of the respective products of the mass-production. Prepared by: Reviewed by: Ki-Hong, Nam / Senior Engineer Y. K. Kwon / Managing Director EMC/RF Center EMC/RF Center ONETECH Corp. ONETECH Corp. FCC ID. : QYA500-1272 Page 2 of 25 Report No.: E132R-033 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div. : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) CONTENTS PAGE 1. VERIFICATION OF COMPLIANCE ............................................................................................................................. 5 2. TEST SUMMARY .............................................................................................................................................................. 6 2.1 TEST ITEMS AND RESULTS ............................................................................................................................................. 6 2.2 ADDITIONS, DEVIATIONS, EXCLUSIONS FROM STANDARDS ........................................................................................... 6 2.3 RELATED SUBMITTAL(S) / GRANT(S) ............................................................................................................................ 6 2.4 PURPOSE OF THE TEST ................................................................................................................................................... 6 2.5 TEST METHODOLOGY .................................................................................................................................................... 6 2.6 TEST FACILITY ............................................................................................................................................................... 6 3. GENERAL INFORMATION ............................................................................................................................................ 7 3.1 PRODUCT DESCRIPTION ................................................................................................................................................. 7 3.2 ALTERNATIVE TYPE(S)/MODEL(S); ALSO COVERED BY THIS TEST REPORT. ................................................................ 7 4. EUT MODIFICATIONS .................................................................................................................................................... 7 5. SYSTEM TEST CONFIGURATION ............................................................................................................................... 8 5.1 JUSTIFICATION ............................................................................................................................................................... 8 5.2 PERIPHERAL EQUIPMENT .............................................................................................................................................. 8 5.3 MODE OF OPERATION DURING THE TEST ...................................................................................................................... 8 5.4 CONFIGURATION OF TEST SYSTEM ............................................................................................................................... 9 5.5 ANTENNA REQUIREMENT .............................................................................................................................................. 9 6. PRELIMINARY TEST ...................................................................................................................................................... 9 6.1 AC POWER LINE CONDUCTED EMISSIONS TESTS ......................................................................................................... 9 6.2 GENERAL RADIATED EMISSIONS TESTS ....................................................................................................................... 9 7. MIMIMUM 6 DB BANDWIDTH ................................................................................................................................... 10 7.1 OPERATING ENVIRONMENT ......................................................................................................................................... 10 7.2 TEST SET-UP ................................................................................................................................................................. 10 7.3 TEST EQUIPMENT USED ..................................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 4 Report No. : E132R-033 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) RF Test Page 2 of 4 Report No. : E132R-033 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) Radiated Emission Test Page 3 of 4 Report No. : E132R-033 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) 1 GHz ~ 6 GHz Page 4 of 4 Report No. : E132R-033 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Div : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)

Contact Information

Applicant

Robert Vidojevski
[email protected]2485040500Fax: 2483489735

Test Firm

ONETECH Corp.Ki Hong Nam
[email protected]82-31-799-9580Fax: 82-31-799-9599

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.46 GHz - 2.46 GHz15.00 µW
Confidentiality
Long Term
Grant Notes
Power output listed is peak conducted. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC accepted multi-transmitter procedures.

Other Applications from Gentherm Inc.

Main Control Unit - FCC ID QYA500-2019 - Gentherm Inc.
QYA500-2019

Main Control Unit

Mar 17, 2013

Equipment Class

DTS - Digital Transmission System