Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Jul 11, 2004
Application Purpose
Original Equipment
Date of Application
Jul 11, 2004
Equipment Note
Wireless Mouse
Frequency Range
27.04500000 - 27.04500000
Company
Shenzhen Longitek Ebest Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

β†—

Block Diagram

β†—

External Photos

β†—

ID Label/Location Info

β†—

Internal Photos

β†—

Operational Description

β†—

Schematics

β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Applicant : Shenzhen Longitek Technology Co., Ltd. FCC ID : R6TRFM308RD

Block Diagram

Applicant : Shenzhen Longitek Technology Co., Ltd. FCC ID : R6TRFM308RD

External Photos

Applicant : Shenzhen Longitek Technology Co., Ltd. FCC ID : R6TRFM308RD Tx top view Tx bottom view

ID Label/Location Info

Applicant : Shenzhen Longitek Technology Co., Ltd. FCC ID : R6TRFM308RD Proposed Label Location on EUT EUT Bottom View/Proposed FCC ID Label Location FCC ID: R6TRFM308RD

Internal Photos

Applicant : Shenzhen Longitek Technology Co., Ltd. FCC ID : R6TRFM308RD Tx inside whole view Tx board component side Tx Main board solder side

Operational Description

Applicant : Shenzhen Longitek Technology Co., Ltd. FCC ID : R6TRFM308RD Operational Description The 3V DC power supply is the whole power supply of the mouse. MCU, under the normal instance of the power supply, crystal brought from Y2-76.8 KHZ. The matching C18, C19, R9.When mouse moving, the signal picked up and then handled by it, transfer to MCU. The signal generated by scroll wheel and button then handled by MCU. The high frequency generated by Y1-27.042MHZ, the matching C14, C10, C11.exported from MCU8#, after the RF antenna inductance matching, export high frequency signal.

Schematics

Applicant : Shenzhen Longitek Technology Co., Ltd. FCC ID : R6TRFM308RD

Test Report

The test report consists 22 pages in total. It may be duplicated completely for legal use with the allowance of the applicant. It shall not be reproduced except in full, without the written approval of Ke Mei Ou Laboratory Corporation. The test result in the report only applied to the tested sample. FCC TEST REPORT Under FCC 15 Subpart C, Paragraph 15.227 Prepared For: Shenzhen Longitek Technology Co., Ltd. Block 37, Xinlesijie, Zone 37, Bao’an District, Shenzhen, China May 25, 2004 FCC ID: R6TRFM308RD EUT: Wireless Mouse Model: RF-M308RD Report Type: Original Report Test Engineer: Peter Lin Test Date: May 18, 2004 Review By: Apollo Liu / Manager Ke Mei Ou Laboratory Co., Ltd. 7A, Jiaxiangge, Jiahuixincheng, No.3027, Shennan Rd., Futian, Shenzhen, Guangdong, P.R.China. Zip Code: 518033 Tel: + 86 755 83642690 Fax: + 86 755 83297077 www.kmolab.com FEDERAL COMMUNICATIONS COMMISSION Registration Number: 125782 INDUSTRY CANADA Registration Number: IC4986 Shenzhen Longitek Technology Co., Ltd. FCC ID: R6TRFM308RD KMO FCC ID Report Report #: KSZ2004041502J01 Page 2 of 22 TABLE OF CONTENTS 1. General Information....................................................................................................................................................3 1. 1 Notes......................................................................................................................................................................3 1. 2 Testing Laboratory..................................................................................................................................................3 1. 3 Details of Applicant................................................................................................................................................3 1. 4 Application Details..................................................................................................................................................3 1. 5 Test Item.................................................................................................................................................................3 1. 6 Test Standards.........................................................................................................................................................4 2. Technical Test...............................................................................................................................................................5 2. 1 Summary of Test Results.........................................................................................................................................5 3. EUT Modifications.......................................................................................................................................................6 4. Conducted Power Line Test.........................................................................................................................................7 4. 1 Test Equipment.......................................................................................................................................................7 4. 2 Test Procedure........................................................................................................................................................7 4. 3 Test Setup...............................................................................................................................................................7 4. 4 Configuration of The EUT.......................................................................................................................................8 4. 5 EUT Operating Condition........................................................................................................................................9 4. 6 Conducted Power Line Emission Limits..................................................................................................................9 4. 7 Conducted Power Line Test Result.........................................................................................................................10 5. Radiated Emission Test...............................................................................................................................................11 5. 1 Test Equipment.....................................................................................................................................................11 5. 2 Test Procedure......................................................................................................................................................11 5. 3 Radiated Test Setup...............................................................................................................................................11 5. 4 Configuration of The EUT.....................................................................................................................................12 5. 5 EUT Operating Condition......................................................................................................................................12 5. 6 Radiated Emission Limit.......................................................................................................................................12 5. 7 Radiated Emission Test Result...............................................................................................................................13 6. Band Edge..................................................................................................................................................................14 6. 1 Test Equipment.....................................................................................................................................................14 6. 2 Test Procedure.......................................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Applicant : Shenzhen Longitek Technology Co., Ltd. FCC ID : R6TRFM308RD Radiated emission test view

Contact Information

Applicant

Owen Wu(Manager)
[email protected]0086-755-29872566Fax: 0086-755-29872223

Test Firm

Ke Mei Ou Laboratory Co., Ltd.Apollo Liu
[email protected]86-755-83642690Fax: 86-755-83297077

Technical Specifications

#Rule PartsFrequency RangePower Output
115C27.045 MHz - 27.045 MHz-

Other Applications from Shenzhen Longitek Ebest Technology Co., Ltd.

WIRELESS KEYBOARD - FCC ID R6TRF-K907 - Shenzhen Longitek Ebest Technology Co., Ltd.
R6TRF-K907

WIRELESS KEYBOARD

May 13, 2007

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
WIRELESS MOUSE - FCC ID R6TRF-M306RC - Shenzhen Longitek Ebest Technology Co., Ltd.
R6TRF-M306RC

WIRELESS MOUSE

May 13, 2007

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Wireless Keyboard - FCC ID R6TK905M308RC - Shenzhen Longitek Ebest Technology Co., Ltd.
R6TK905M308RC

Wireless Keyboard

Jul 11, 2004

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter