Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
attn: Reviewing Engineer Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 RE: LETTER OF AGENT AUTHORIZATION October 5, 2004 To Whom It May Concern: We, the undersigned, hereby authorize MET Laboratories, Inc. to act on our behalf in all matters relating to application for equipment authorization (FCC ID: R7BMMB22600), including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988,21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, P.A. Ms. Georgia Theodorou Laboratory Manager Copreci S. Coop Avenida de Álava nº 3, 20550 Aretxabaleta - Guipuzcoa, Spain Phone: +34 943 719499 E-mail: [email protected]
Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 October, 2004 TO WHOM IT MAY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, Copreci S. Coop. requests confidentiality for the following product: FCC ID Number Product Title/Model R7BMMB22600 Remote control system / MMB-22600 For the product stated above, we request that the following information be held confidential: 1) Circuit diagrams 2) Block Diagrams 3) Bill of materials 4) Operational Description No other items submitted as part of the equipment authorization filing process are deemed confidential. The above exhibits contain Copreci S. Coop. trade secrets and proprietary information that could be of benefit to our competitors regarding the design of our devices. This material is not customarily available to the general public and we request that it be withheld from public inspection. If you have any questions, please feel free to contact me at the address shown below. Sincerely, P.A. Ms. Georgia Theodorou Laboratory Manager Copreci S. Coop Avenida de Álava nº 3, 20550 Aretxabaleta - Guipuzcoa, Spain Phone: +34 943 719499 E-mail: [email protected]
EXTERNAL PHOTO
MVC-755F.JPG (640 x 480 x 24)
INTERNAL PHOTOS
Report No.: 20119RET Date: 2004-06-11 Page: 2 of 8 FDT08_04 INDEX 1. COMPETENCE AND GUARANTEES..........................................................................................3 2. GENERAL CONDITIONS..............................................................................................................3 3. CHARACTERISTICS OF THE TEST............................................................................................3 3.1 TEST REQUESTED.................................................................................................................3 3.2 REQUIREMENTS AND METHOD........................................................................................3 4. IDENTIFICATION DATA SUPPLIED BY THE APPLICANT.....................................................5 4.1 APPLICANT.............................................................................................................................5 4.2 REPRESENTATIVE................................................................................................................5 4.3 TEST SAMPLES SUPPLIER...................................................................................................5 4.4 IDENTIFICATION OF ITEM/ITEMS TESTED.....................................................................5 5. USAGE OF SAMPLES, PERIOD OF TESTING AND ENVIRONMENTAL CONDITIONS.....6 5.1 USAGE OF SAMPLES............................................................................................................6 5.2 PERIOD OF TESTING............................................................................................................6 5.3 ENVIROMENTAL CONDITIONS..........................................................................................6 6. TEST RESULTS..............................................................................................................................8 7. REMARKS AND COMMENTS......................................................................................................8 8. SUMMARY......................................................................................................................................8 ANNEXES ANNEX A. TEST RESULTS ANNEX B. PHOTOGRAPHS Report No.: 20119RET Date: 2004-06-11 Page: 3 of 8 FDT08_04 1. COMPETENCE AND GUARANTEES Centro de Tecnología de las Comunicaciones (CETECOM), S.A. is a laboratory with a measurement facility in compliance with the requirements of Section 2.948 of the FCC rules and has been added to the list of facilities whose measurements data will be accepted in conjuction with applications for Certification under Parts 15 or 18 of the Commission's Rules. Registration Number: 905266. Centro de Tecnología de las Comunicaciones (CETECOM), S.A. is a laboratory with a measurement site in compliance with the requirements of RSS 212, Issue 1 (Provisional) and has been added to the list of filed sites of the Canadian Certification and Engineering Bureau. Reference File Number: IC 4621. In order to assure the traceability to other national and international laboratories, CETECOM has a calibration and maintenance programme for its measuring equipment. CETECOM guarantees the reliability of the data presented in this report, which is the result of measurements and tests performed to the item under test on the date and under the conditions stated on the report and is based on the knowledge and technical facilities available at CETECOM at the time of execution of the test. CETECOM is liable to the client for the maintenance by its personnel of the confidentiality of all information related to the item under test and the results of the test. 2. GENERAL CONDITIONS 1. This report only refers to the item that has undergone the test. 2. This report does not constitute or imply by its own an approval of the product by the Certification Bodies or competent Authorities. 3. This document is only valid if complete; no partial reproduction can be made without written approval of CETECOM. 4. This test report cannot be used partially or in full for publicity and/or promotional purposes without previous written approval of CETECOM and the Accreditation Bodies. 3. CHARACTERISTICS OF THE TEST 3.1 TEST REQUESTED Measurements for equipment with periodic operation in the band 40.66 – 40.70 MHz and above 70 MHz, according to FCC Part 15.231. 3.2 REQUIREMENTS AND METHOD The test has been carried out according to FCC parts 15.33, 15.35, 15.205, 15.209 and 15.231. The testing was performed according to the procedure in ANSI C63.4 (1992). Radiated testing was performed in Cetecom's semi-anechoic chamber. This site has been fully described in a report submitted to the FCC and was accepted in a letter dated July 25, 2002. Report No.: 20119RET Date: 2004-06-11 Page: 4 of 8 FDT08_04 The instrumentation used to perform the testing is listed below: 1. Semianechoic Absorber Lined Chamber IR 11. BS. 2. Control Chamber IR 12.BC. 3. Spectrum Analyzer HP 8566 B. 4. RF Preselector HP 85685A. 5. Quasi-peak adaptor HP 85650A. 6. RF linear amplifier HP 8447.F 7. Antenna mast EM 1072 NMT. 8. Rotating table EM 1084-4. ON. 9. Mast controller EM 1053-22. 10. Rotating table controller EM 1064-4023. 11. Process controller HP 98581C. 12. Harddisk HP 9153. 13. Peripheral unit HP 9153 C. 14. Measurement software HP 85879A. 15. 3 dB attenuator HP 8491A. 16. Bilog antenna CHASE CBL6111. 17. Bilog antenna CHASE CBL6111. 18. Antenna tripod EMCO 11968C. 19. Double-ridge Guide Horn antenna 1-18 GHz HP 11966E. 20. EMI Test Receiver R&S ESIB26. Report No.: 20119RET Date: 2004-06-11 Page: 5 of 8 FDT08_04 4. IDENTIFICATION DATA SUPPLIED BY THE APPLICANT Identification data in this section has been supplied by the client. 4.1 APPLICANT Name or Company: COPRECI S. COOP. V.A.T.: F-20025474 Address: Avda. de Alava, 3 City: Aretxabaleta (Guipúzcoa) Postal code: 20550 Country: SPAIN Telephone: +34 943719499 Fax: +34 943792349 4.2 REPRESENTATIVE Name: Georgia Theodorou 4.3 TEST SAMPLES SUPPLIER N…
Text truncated - open the document above for the full version.
91010001.jpg (1600 x 1200 x 24)
91010002.jpg (1600 x 1200 x 24)
91010003.jpg (1600 x 1200 x 24)
91010004.jpg (1600 x 1200 x 24)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.93 MHz - 433.93 MHz | - |