FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. ELO TOUCH SOLUTIONS INTERNATIONAL INC./
  3. R7QESY15M-RFID

R7QESY15M-RFID15" Touch Computer

ELO TOUCH SOLUTIONS INTERNATIONAL INC.
15" Touch Computer - FCC ID R7QESY15M-RFID - ELO TOUCH SOLUTIONS INTERNATIONAL INC.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Dec 16, 2012
Application Purpose
Original Equipment
Date of Application
Dec 16, 2012
Equipment Note
15" Touch Computer
Frequency Range
13.56000000 - 13.56000000
Company
ELO TOUCH SOLUTIONS INTERNATIONAL INC.
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗
↗
↗
↗

Internal Photos

↗

Operational Description

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

M-Series Touchcomputer User Guide M-Series LCD Multi-function Touchcomputer [19” model shown with optional accessories] M-Series Touchcomputer User Guide ii Elo Touch Solutions M-Series Touchcomputer for Healthcare Applications User Guide Multi-function Touchcomputer Revision 2 SW200069 1-800-ELOTOUCH (1-800-356-8682) www.elotouch.com M-Series Touchcomputer User Guide iii Copyright © 2012 Elo Touch Solutions Inc. All Rights Reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, including, but not limited to, electronic, magnetic, optical, chemical, manual, or otherwise without prior written permission of Elo Touch Solutions. Disclaimer The information in this document is subject to change without notice. Elo Touch Solutions Inc. Elo Touch Solutions makes no representations or warranties with respect to the contents herein, and specifically disclaims any implied warranties of merchantability or fitness for a particular purpose. Elo Touch Solutions reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of Elo Touch Solutions to notify any person of such revisions or changes. Trademark Acknowledgments AccuTouch, Elo TouchSystems, Elo TouchSystems (logo), Elo, IntelliTouch, iTouch, Elo Touch Solutions, and Elo Touch Solutions (logo) are trademarks. Windows is a trademark of Microsoft Corporation. Other product names mentioned herein may be trademarks or registered trademarks of their respective companies. Elo Touch Solutions claims no interest in trademarks other than its own. M-Series Touchcomputer User Guide iv Warnings and Cautions Warning • Danger - Explosion hazard. Do not use in the presence of flammable anesthetics, and other flammable materials. • To prevent fire or shock hazards, do not immerse the unit in water or expose it to rain or moisture. • Do not use the unit with an extension cord receptacle or other outlets unless the prongs of the power cord can be fully inserted. • RISK OF ELECTRICAL SHOCK - DO NOT OPEN. To reduce the risk of electrical shock, DO NOT remove the back of the equipment or open the enclosure. No user-serviceable parts are inside. Refer servicing to qualified field service engineers only. • Uninsulated voltage within the unit may have sufficient magnitude to cause electrical shock. Avoid contact with any part inside the unit. • This device complies with the electromagnetic emission and immunity standards and is limited to the standards that are listed on pages 41 and 45. Other devices which are not designed to withstand emission levels as specified in the medical device standards may be susceptible to interference from this device. Subjecting the device to conditions beyond the rated performance capabilities may result in emissions in excess of the standard. If it is determined that this device produces electromagnetic or other interference it must be disconnected from power until the cause of the problem has been determined and resolved. If it is determined that this device is functioning improperly due to electromagnetic and other interference it must be disconnected from power until the cause of the problem has been determined and resolved. • Elo Touch Solutions recommends that after its useful life (or after sustaining unrepairable damage), customers dispose of the touchcomputer and its power supply in an environmentally sound manner. Acceptable methods include the reuse of parts or whole products and the recycling of products, components, and materials. Please consult and obey national state, and local laws and ordinances governing the safe disposal of electronic equipment. • Do not modify this equipment without authorization of the manufacturer. This product consists of devices that may contain mercury, which must be recycled or disposed of in accordance with local, state, or federal laws. M-Series Touchcomputer User Guide v Caution ƒ Power cord is used as a disconnection device. To de-energize equipment, disconnect the power cord. ƒ This unit must follow the national requirement and local state laws to dispose unit. ƒ Before connecting the cables to your Elo touchcomputer, make sure all components are powered OFF. ƒ Only approved components complying with IEC 60601-1 series can be connected to 15MX/19MX Touchcomputer for Healthcare Applications in Patient Environment. The use of ACCESSORY equipment not complying with the equivalent safety requirements of this equipment may lead to a reduced safety of the resulting system. Consideration relating to the choices of accessory equipment should include: Use of accessory in the patient environment.· Evidence that the safety certification of the accessory has been performed in accordance to the appropriate IEC 60601-1 and/or IEC 60601-1-1 harmonized national standard. ƒ For continued safety • This unit only complies to the above standards if used with a medical grade power cord. • A medical grade power supply, such as the one specified, is required for use in a medical application. ƒ Please do not touch the patient and the touchcomputer output connecter at the same time. ƒ The touchmonitor is to be used with following adaptor: 1. XP Power / AHM85PS12 or 2. Elo Touch Solutions / FSP110-RAAM Disposing of your old product Within the European Union EU-wide legislation, as implemented in each Member State, requires that waste electrical and electronic products carrying the mark (left) must be disposed of separately from normal household waste. This includes monitors and electrical accessories, such as signal cables or power cords. When you need to dispose of your display products, please follow the guidance of your local authority, or ask the shop where you purchased the product, or if applicable, follow any agreements made between yourself and the supplier of this product. The mark on electrical and electro…

Text truncated - open the document above for the full version.

Cover Letter(s)

ELO TOUCH SOLUTIONS INTERNATIONAL INC. 3F, No. 45, Dongsing Road, Taipei 11070 Taiwan Tel: +886-2-8768-2788 Fax: +886-2-8768-2089 Date: 2012-12-06 FCC ID: FCC ID: FCC ID: FCC ID: R7QESY15M R7QESY15MR7QESY15M R7QESY15M- -- -RFID RFIDRFID RFID To the attention of Federal Communications Commission Federal Communications CommissionFederal Communications Commission Federal Communications Commission Authorization and Evaluation Division Confidentiality Request Confidentiality RequestConfidentiality Request Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, the Applicant hereby requests confidential treatment of information accompanying this Application as outlined below: Schematics SchematicsSchematics Schematics Block Diagram Block DiagramBlock Diagram Block Diagram The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457, disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely yours, ________________________________________________ Title: Sr. Safety Engineer Tel: +886-2-8768-2788 Fax: +886-2-8768-2089 E-mail: [email protected]

Cover Letter(s)

ELO TOUCH SOLUTIONS INTERNATIONAL INC. 3F, No. 45, Dongsing Road, Taipei 11070 Taiwan Tel: +886-2-8768-2788 Fax: +886-2-8768-2089 Date: 2012-12-06 A U T H O R I Z A T I O N L E T T E R To whom it may concern: We, the undersigned ELO TOUCH SOLUTIONS INTERNATIONAL INC. ELO TOUCH SOLUTIONS INTERNATIONAL INC.ELO TOUCH SOLUTIONS INTERNATIONAL INC. ELO TOUCH SOLUTIONS INTERNATIONAL INC. hereby authorize Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch (BV CPS Taoyuan) of Taiwan to act on our behalf in all matters relating to all processes required in FCC Part 15C and any communication needed with the national authority. Any and all acts carried out by BV CPS Taoyuan on our behalf shall have the same effects as acts of our own. FCC ID: FCC ID: FCC ID: FCC ID: R7QESY19M R7QESY19MR7QESY19M R7QESY19M- -- -RFID RFIDRFID RFID FCC ID: FCC ID: FCC ID: FCC ID: R7QESY15M R7QESY15MR7QESY15M R7QESY15M- -- -RFID RFIDRFID RFID If you have any questions regarding the authorization, please don’t hesitate to contact us. Thank you! Sincerely yours, ------------------------------------ Title: Sr. Safety Engineer Tel: +886-2-8768-2788 Fax: +886-2-8768-2089 E-mail: [email protected]

External Photos

Page 1 CONSTRUCTION PHOTOS OF EUT Page 2 Page 3 Page 32 Page 33 Page 34 Page 35

Internal Photos

Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16 Page 17 Page 18 Page 19 Page 20 Page 21 Page 22 Page 23 Page 24 Page 25 Page 26 Page 27 Page 28 Page 29 Page 30 Page 31

Operational Description

FCC ID: R7QESY15M-RFID Report No.: RF121024C23 Operational Description The transmitter of the EUT (15” Touch computer) is powered by 12Vdc from AC adapter. The antenna is Flexible antenna with SMD RA antenna connector. For more detailed instruction, please take a look at the user’s manual.

Test Report

Report No.: RF121024C23 1 of 30 Report Format Version 5.0.0 FCC TEST REPORT (RFID) REPORT NO.: RF121024C23 MODEL NO.: ESY15M1, ESY15M2 FCC ID: R7QESY15M-RFID RECEIVED: Oct. 24, 2012 TESTED: Nov. 13 ~ Nov. 16, 2012 ISSUED: Nov. 20, 2012 APPLICANT: ELO TOUCH SOLUTIONS INTERNATIONAL INC. ADDRESS: 3F, No. 45, Dongsing Road, Taipei 11070 Taiwan ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch LAB ADDRESS: No. 47, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan, R.O.C. TEST LOCATION: No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the com pliance or non-compliance to the specification. This report should not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. Report No.: RF121024C23 2 of 30 Report Format Version 5.0.0 Table of Contents RELEASE CONTROL RECORD .............................................................................................................. 3 1. CERTIFICATION ........................................................................................................................... 4 2. SUMMARY OF TEST RESULTS .................................................................................................. 5 2.1 MEASUREMENT UNCERTAINTY ................................................................................................ 5 3. GENERAL INFORMATION ........................................................................................................... 6 3.1 GENERAL DESCRIPTION OF EUT ............................................................................................. 6 3.2 DESCRIPTION OF TEST MODES ............................................................................................... 7 3.2.1 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL ............................................... 8 3.3 DESCRIPTION OF SUPPORT UNITS ......................................................................................... 9 3.3.1 CONFIGURATION OF SYSTEM UNDER TEST .......................................................................... 9 3.4 GENERAL DESCRIPTION OF APPLIED STANDARDS ............................................................ 10 4. TEST TYPES AND RESULTS .................................................................................................... 11 4.1 RADIATED EMISSION MEASUREMENT .................................................................................. 11 4.1.1 LIMITS OF RADIATED EMISSION MEASUREMENT ............................................................... 11 4.1.2 TEST INSTRUMENTS ................................................................................................................ 12 4.1.3 TEST PROCEDURES ................................................................................................................ 13 4.1.4 DEVIATION FROM TEST STANDARD ...................................................................................... 13 4.1.5 TEST SETUP .............................................................................................................................. 14 4.1.6 EUT OPERATING CONDITIONS ............................................................................................... 14 4.1.7 TEST RESULTS ......................................................................................................................... 15 4.2 CONDUCTED EMISSION MEASUREMENT ............................................................................. 19 4.2.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT .......................................................... 19 4.2.2 TEST INSTRUMENTS ................................................................................................................ 19 4.2.3 TEST PROCEDURES ................................................................................................................ 20 4.2.4 DEVIATION FROM TEST STANDARD ...................................................................................... 20 4.2.5 TEST SETUP .............................................................................................................................. 20 4.2.6 EUT OPERATING CONDITIONS ............................................................................................... 20 4.2.7 TEST RESULTS ......................................................................................................................... 21 4.3 FREQUENCY STABILITY ........................................................................................................... 23 4.3.1 LIMITS OF FREQUENCY STABILITY MEASUREMENT ........................................................... 23 4.3.2 TEST INSTRUMENTS ............…

Text truncated - open the document above for the full version.

Test Setup Photos

1 PHOTOGRAPHS OF THE TEST CONFIGURATION CONDUCTED EMISSION TEST 2 RADIATED EMISSION TEST

Contact Information

Applicant

Angela Huang(Sr. Safety Engineer)
[email protected]+886-2-8768-2788Fax: +886-2-8768-2089

Test Firm

Bureau Veritas CPS (H.K.) Ltd., Taoyuan BranchRichard Chen
[email protected]+886-3-2600884Fax: +886-3-2115834

Technical Specifications

#Rule PartsFrequency RangePower Output
115C13.56 MHz - 13.56 MHz-
Confidentiality
Long Term

Other Applications from ELO TOUCH SOLUTIONS INTERNATIONAL INC.

19" Touch Computer - FCC ID R7QESY19M-RFID - ELO TOUCH SOLUTIONS INTERNATIONAL INC.
R7QESY19M-RFID

19" Touch Computer

Dec 16, 2012

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter