β’ The test results reported in this report shall refer only to the sample actually tested and shall not refer or be deemed to refer to bulk from which such a sample may be said to have been obtained. β’ This report shall not be reproduced except in full without prior authorization from Intertek Testing Services Hong Kong Limited. β’ The evaluation data of the report will be kept for 3 years from the date of issuance. FCC ID: R9YWEIFAI-822 Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com Wei Fai Electronic Plastic Company Application For Certification (FCC ID: R9YWEIFAI-822) RF Lighting Device Sample Description : Gold Phone Model : WF822 We hereby certify that the sample of the above item is considered to comply with the requirements of FCC Part 18, Subpart C for RF lighting devices, mention 47 CFR [10-1-2002] 0409164 BC/ec December 9, 2004 INTERTEK TESTING SERVICES FCC ID: R9YWEIFAI-822 i LIST OF EXHIBITS INTRODUCTION EXHIBIT 1: General Description EXHIBIT 2: System Test Configuration EXHIBIT 3: Emission Results EXHIBIT 4: Equipment Photographs EXHIBIT 5: Product Labelling EXHIBIT 6: Technical Specifications EXHIBIT 7: Instruction Manual INTERTEK TESTING SERVICES FCC ID: R9YWEIFAI-822 ii MEASUREMENT/TECHNICAL REPORT Wei Fai Electronic Plastic Company - MODEL: WF-822 FCC ID: R9YWEIFAI-822 December 9, 2004 This report concerns (check one:) Original Grant X Class II Change Equipment Type: RF Lighting Deferred grant requested per 47 CFR 0.457(d)(1)(ii)? Yes No X If yes, defer until: date Company Name agrees to notify the Commission by: date of the intended date of announcement of the product so that the grant can be issued on that date. Transition Rules Request per 18.123? Yes No X If no, assumed Part 18 for RF lighting device - the new 47 CFR Part 18 [10-1-2002 Edition] provision. Report prepared by: Billy Chow Intertek Testing Services 2/F., Garment Centre, 576, Castle Peak Road, HONG KONG Phone: 852-2173-8491 Fax: 852-2742-6487 INTERTEK TESTING SERVICES FCC ID: R9YWEIFAI-822 iii Table of Contents 1.0 General Description................................................................................................... 2 1.1 Product Description ................................................................................................ 2 1.2 Related Submittal(s) Grants.................................................................................... 2 1.3 Test Methodology ................................................................................................... 3 1.4 Test Facility............................................................................................................. 3 1.5 Equipment List..............................................................................................................4 2.0 System Test Configuration ........................................................................................ 6 2.1 Justification ............................................................................................................. 6 2.2 EUT Exercising Software ........................................................................................ 6 2.3 Special Accessories................................................................................................ 6 2.4 Equipment Modification........................................................................................... 7 2.5 Support Equipment List and Description ................................................................. 7 3.0 Emission Results ....................................................................................................... 9 3.1 Line Conducted Configuration Photograph (contβd) .............................................. 10 3.2 Line Conducted Emission Data ................................................................................. 11 4.0 Equipment Photographs .......................................................................................... 13 5.0 Product Labelling ..................................................................................................... 15 6.0 Technical Specifications ......................................................................................... 17 7.0 Instruction Manual ................................................................................................... 19 INTERTEK TESTING SERVICES FCC ID: R9YWEIFAI-822 iv List of attached file Exhibit type File Description filename Test Report Test Report report.pdf Operation Description Technical Description descri.pdf Test Setup Photo Conducted Emission conducted photos.pdf Test Report Conducted Emission Test Result conducted.pdf External Photo External Photo external photos.pdf Internal Photo Internal Photo internal photos.pdf Block Diagram Block Diagram block.pdf Schematics Circuit Diagram circuit.pdf ID Label/Location Label Artwork and Location label.pdf User Manual User Manual manual.pdf INTERTEK TESTING SERVICES FCC ID: R9YWEIFAI-822 1 EXHIBIT 1 GENERAL DESCRIPTION INTERTEK TESTING SERVICES FCC ID: R9YWEIFAI-822 2 1.0 General Description 1.1 Product Description The equipment under test (EUT) is a Gold Phone. The unit is a corded phone with a neon light. It is powered by 120V AC and the neon light part is operated with 40kHz. Neon Light: Connect 120V AC source to the AC-DC adaptor. A DC source passes though a regulator, oscillator and step up transformer. Then, a high frequency high voltage pulse driving the neon tube. When the neon switch is in the βONβ position, the light will remain on while the handset is on the base, but will shut off when the handset is lifted. If the neon switch is in the βOFFβ position, the neon light will remain off except for when receiving a call. Incoming calls always flash the neon light. For electronic filing, the brief circuit description is saved with filename: descri.pdf Coβ¦
Text truncated - open the document above for the full version.
Report No.:0409164 (Live) Ctrl No.:N/A PAGE 1 Tested By:Hong, Report No.:0409164 Scan Settings (1 Range) |--------- Frequencies -----------||----------- Receiver Settings ------------| Start Stop Step IF BW Detector M-Time Atten Preamp OpRge 450k 30M 5k 10k PK 20ms AUTO LN OFF 60dB Final Measurement: x QP Meas Time: 1 s Subranges: 16 Acc Margin: 20dB Transducer No. Start Stop Name 21 9k 30M EW0698 0 10 20 30 40 50 60 70 80 90 dBuV 100 0.45 30 MHz 110 FCC18C Report No.:0409164 (Live) Ctrl No.:N/A Tested By:Hong, Report No.:0409164 Scan Settings (1 Range) |--------- Frequencies -----------||----------- Receiver Settings ------------| Start Stop Step IF BW Detector M-Time Atten Preamp OpRge 450k 30M 5k 10k PK 20ms AUTO LN OFF 60dB Final Measurement Results: Frequency QP Level QP Limit MHz dBuV dBuV 0.49500 41.2 48.0 0.71500 34.2 48.0 0.93500 33.7 48.0 0.99000 30.3 48.0 1.54000 28.9 48.0 23.00000 27.6 48.0 * limit exceeded
INTERTEK TESTING SERVICES Front View Back View INTERTEK TESTING SERVICES Side View
2/F., Garment Centre, Β· Kowloon Β· Hong Kong
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 18 | 0.04 MHz - 0.04 MHz | - |