
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
THANK YOU We appreciate the trust and confidence you have placed in Home Decorators Collection through the purchase of this ceiling fan. We strive to continually create quality products designed to enhance your home. Visit us online to see our full line of products available for your home improvement needs. Thank you for choosing Home Decorators Collection! Item #xxxx xxx xxx Model #56055 UL Model #60-SHURI USE AND CARE GUIDE FELDNER 60-INCH CEILING FAN To view an instructional video on how to install this product: 1. Go to www.homedepot.com and enter either the Item or Model number, found in the top right corner of the cover of this instruction manual, in the search eld. 2. Click on your product from the list of search results and click on the video link in the “Product Overview” section. Questions, problems, missing parts? Before returning to the store, call Hubspace Customer Service 8 a.m. - 7 p.m., EST, Monday-Friday, 9 a.m. - 6 p.m., EST, Saturday 1-877-592-5233 HOMEDEPOT.COM/HUBSPACE 2 Table of Contents ................................................................2 Safety Information ...............................................................2 Warranty ...............................................................................3 Pre-Installation ....................................................................3 Installation ............................................................................6 Assembly ..............................................................................7 Operation ...........................................................................13 Care and Cleaning .............................................................16 Troubleshooting .................................................................16 1. To reduce the risk of electric shock, ensure the electricity has been turned off at the circuit breaker or fuse box before you begin. 2. All wiring must be in accordance with the National Electrical Code ANSI/NFPA 70 and local electrical codes. Electrical installation should be performed by a qualified licensed electrician. 3. The outlet box and support structure must be securely mounted and capable of reliably supporting a minimum of 35 lb (15.9 kg). Use only UL Listed outlet boxes marked “Acceptable for Fan Support of 35 lb (15.9 kg) or less.” 4. The fan must be mounted with a minimum of 7 ft. (2.1 m) of clearance from the trailing edge of the blades to the floor. 5. Do not place objects in the path of the blades. 6. To avoid personal injury or damage to the fan and other items, use caution when working around or cleaning the fan. 7. After making electrical connections, spliced conductors should be turned upward and pushed carefully up into the outlet box. The wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box. 8. All set screws must be checked and retightened where necessary before installation. 9. Suitable for damp locations. WARNING: To reduce the risk of personal injury, do not bend the blade brackets (also referred to as flanges) during assembly or after installation. Do not insert objects in the path of the blades. WARNING: To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device. WARNING: To avoid possible electrical shock, turn the electricity off at the main fuse box before wiring. If you feel you do not have enough electrical wiring knowledge or experience, contact a licensed electrician. Safety Information Table of Contents CAUTION: To reduce the risk of personal injury, use only the screws provided with the outlet box. WARNING: To reduce the risk of fire, electric shock or personal injury, mount to outlet box marked “Acceptable for fan support of 35 lb (15.9 kg) or less”, and use screws provided with the outlet box. READ AND SAVE THESE INSTRUCTIONS. WARNING: To reduce the risk of fire or electric shock, this fan should only be used with fan speed control part no. JY1156H-F-EL-F1, manufactured by Satellite Industrial Co., Ltd. CAUTION: Do NOT use this fan with a dimmer switch or wall control. Using a dimmer switch or wall control will damage the fan. CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. WARNING: To reduce the risk of electric shock, this fan must be installed with an isolating wall switch. 3 HOMEDEPOT.COM/HUBSPACE Please contact 1-877-592-5233 for further assistance. Pre-Installation Warranty SPECIFICATIONS NOTE: These are approximate measures. They do not include the amps and wattage used by the light kit. SizeSpeedVolts Fan Power Consumption (without lights) WATT Airflow CFM Airflow Efficiency (higher is better) CFM/WATT Net Weight Gross Weight Cubic Feet 60 in. Low 120 63662610 21.05 lb (9.55 kg) 28.29 lb (12.83 kg) 2.89 cu. ft. Medium166001375 High408578214 TOOLS REQUIRED Phillips screwdriver Flat blade screwdriver Adjustable wrench Electrical tape Wire cutter/ stripper Step ladder The supplier warrants the fan motor to be free from defects in workmanship and material present at time of shipment from the factory for a lifetime after the date of purchase by the original purchaser. The supplier also warrants that all other fan parts, excluding any glass or acrylic blades, to be free from defects in workmanship and material at the time of shipment from the factory for a period of two years after the date of purchase by the original purchaser. We agree to correct such defects without charge or at our option replace with a comparable or superior model if the product is returned. To obtain warranty service, you must present a copy of the receipt as proof of purchase. All costs of removing and reinstalling the product are your responsibility. Damage to any part, such as by accident, misuse, improper installation, or by affixing any accessories, is not covered by this warranty. Because…
Text truncated - open the document above for the full version.
King of Fans, Inc. Statement We King of Fans, Inc. Hereby Declare that The product 56055-60in Feldner( was Shuri), 60-SHURI are all identical in interior structure, electrical circuits and components, and just the model names are different for the marketing requirement. Your assistance on this matter is highly appreciated. Yours sincerely, Signature: Company Name: King of Fans, Inc.
March 03,, 2022 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act as Agent On our behalf, I appoint Shenzhen Timeway Testing Laboratories/ Zone C, 1st Floor, Block B, Jun Xiang Da Building, Zhongshan Park Road West, Tong Le Village, Nanshan District, Shenzhen, China (Name of Agent company name and address) to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with King of Fans, Inc./ 1951 N.W. 22nd Street, Fort Lauderdale, FL33311, USA <Signature>: Name:Charles Bucher Title:VP of Engineering Company:King of Fans, Inc.
May 05, 2022 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: RGB-60-S HURIS Product Na me: 60in Feldner ( was Shuri) Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: • Schematics • Block diagram • Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. <Signature>: Name:Charles Bucher Title:VP of Engineering Company:King of Fans, Inc.
! " ! # $ % & & & ' % " ( " $ # ( % ! $ $ ' ( ' ! ' ( $ ( ' ! ( % % $ ' ( ' # ' $ % $ ' # ' ! ) ' ) ) ! " ! # $ % & & & ' % " ( " # % $ ' ( ' ( ( ' % $ ' ( ' # ' $ % % $ ( ! $ ! ' $ % ( ! # ' $ * ' & ) # ) $ ' # $ ' + , - . / , ) ) 0 ' ) # ' ( This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Label Location
Report No.: TW2204085E File Reference No.: 2022-04-25 Applicant: King of Fans, Inc. Product: 60in Feldner ( was Shuri) Trademark: Home Decorators Collection Model No.: 56055-60in Feldner( was Shuri), 60-SHURI Test Standards: FCC Part 15 Subpart B Test Result: It is herewith confirmed and found to comply with the requirements set up by ANSI C63.4&FCC Part 15 regulations for the evaluation of electromagnetic compatibility Approved By Terry Tang Manager Dated: April 25, 2022 Results appearing herein relate only to the sample tested The technical reports is issued errors and omissions exempt and is subject to withdrawal at SHENZHEN TIMEWAY TESTING LABORATORIES. Zone C, 1st Floor, Block B, Jun Xiang Da Building, Zhongshan Park Road West, Tong Le Village, Nanshan District, Shenzhen, China Tel (755) 83448688 Fax (755) 83442996 Email: [email protected] Report No.: TW2204085E Page 2 of 26 Date: 2022-04-25 "The report refers only to the sample tested and does not apply to the bulk production. This report is issued in confidential to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for illegal purpose. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES reserves the rights to withdraw it and to adopt any other remedies which may be appropriate." Special Statement: The testing quality ability of our laboratory meet with "Quality Law of People's Republic of China" Clause 19. The testing quality system of our laboratory meet with ISO/IEC-17025 requirements, which is approved by CNAS. This approval result is accepted by MRA of APLAC. Our test facility is recognized, certified, or accredited by the following organizations: CNAS-LAB Code: L2292 The EMC Laboratory has been assessed and in compliance with CNAS-CL01 accreditation criteria for testing Laboratories (identical to ISO/IEC 17025:2005 General Requirements) for the Competence of testing Laboratories. FCC-Registration No.: 744189 The EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications commission. The acceptance letter from the FCC is maintained in our files. Registration No.: 744189. Industry Canada (IC) —Registration No.:5205A The EMC Laboratory has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 5205A. A2LA (Certification Number:5013.01) The EMC Laboratory has been accredited by the American Association for Laboratory Accreditation (A2LA). Certification Number:5013.01 Report No.: TW2204085E Page 3 of 26 Date: 2022-04-25 "The report refers only to the sample tested and does not apply to the bulk production. This report is issued in confidential to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for illegal purpose. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES reserves the rights to withdraw it and to adopt any other remedies which may be appropriate." Content 1.0 General Details ................................................................................................................................................... 4 1.1 Test Lab Details ........................................................................................................................................... 4 1.2 Applicant Details ......................................................................................................................................... 4 1.4 Submitted Sample: 1 pc ............................................................................................................................... 4 1.5 Test Duration ............................................................................................................................................... 4 1.6 Test Uncertainty ........................................................................................................................................... 4 1.7 Test Engineer ............................................................................................................................................... 4 2.0 List of Measurement Equipment ...................................................................................................................... 5 2.1 Conducted Emission Test ............................................................................................................................. 5 2.2 Radiated electromagnetic disturbance test ................................................................................................... 5 2.3 Auxiliary Equipment .................................................................................................................................... 5 3.0 Technical Details ................................................................................................................................................ 6 3.1 Investigations Requeste…
Text truncated - open the document above for the full version.
Conducted Emission Test Setup: Radiated Emission Test Setup:
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | 304.25 MHz - 304.25 MHz | - |

Low Voltage smart transformer
Equipment Class
DTS - Digital Transmission System
52 in Campbell, 91350/91359
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
52 in Junedale (was Sarasota) 52188
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
54 Inch Fanelee 52133
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
52 inch Everaine(was Lionel)52111
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter