RGZ-C7Motion Sensor with frequency hopping transceiver

Heyrex Limited
Motion Sensor with frequency hopping transceiver - FCC ID RGZ-C7 - Heyrex Limited
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Nov 09, 2014
Application Purpose
Original Equipment
Date of Application
Nov 09, 2014
Equipment Note
Motion Sensor with frequency hopping transceiver
Frequency Range
2402.00000000 - 2462.00000000
Company
Heyrex Limited
Country
New Zealand

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User Manual Contents About Heyrex ............................................................................................................. 3 Contents of the Box .................................................................................................... 4 The Hardware ............................................................................................................. 5 Setting up your Heyrex Monitoring System ................................................................ 6 Setup Diagram ............................................................................................................ 8 Changing the Batteries ............................................................................................... 9 Troubleshooting and Support ................................................................................... 10 Warranty Information .............................................................................................. 10 Compliance Information ....................................................................................... 11/12 [email protected] About Heyrex Heyrex is a revolutionary new way to monitor your dog’s wellbeing. It captures your dog’s behaviour 24/7 and reports online. Simply set up your dog’s profile online at www.heyrex.com/setup and attach the biosensor to your dog’s collar to obtain peace of mind. The biosensor collects information about your dog’s activity and behavior and uploads it to the receiver. The receiver sends the information to the Heyrex servers which analyse the information and then displays it in graphs for you to view online. Heyrex can be used for monitoring general wellbeing or as a tool to identify potential signs of specific health conditions such as skin conditions, joint disorders, heart conditions, obesity and weight loss, behaviour problems and much more. With Heyrex your dog’s profile can be linked to your vet for even greater peace of mind. Heyrex can automatically advise your vet of any behaviour changes your dog encounters. To learn more about Heyrex please visit www.heyrex.com Contents of the Box Complete Heyrex Biometric System Biosensor capsule with surround Collar adaptor Batteries Receiver unit Network cable Aerial Power adaptor Heyrex Additional/Replacement Biosensor Capsule Biosensor capsule with surround Collar adaptor Batteries Heyrex Additional/Replacement Receiver Receiver unit Network cable Aerial Power adaptor [email protected] The Hardware Biosensor Capsule The biosensor capsule gets attached to your dog's collar and positioned under its chin. It uses biometric technology to monitor and record your dog's activity and behaviour. When the biosensor comes within range of a Receiver it will transfer its information to the Receiver. The biosensor can hold up to 7 days of information in its memory. If the biosensor does become full, it will stop recording until it is able to upload the data to a receiver. The biosensor capsule is sold in a waterproof condition. Additional and replacement biosensors are sold separately. Receiver The Receiver is an Ethernet device that plugs into your router or modem and communicates with the Heyrex biosensor wirelessly. When a biosensor comes within range of a Receiver it will transfer all of its stored information to that Receiver which then uploads it to the Heyrex servers, via your internet connection. Any biosensor can upload to any Receiver. All data is sent with each dog's unique device code so that it can be identified. However, no personally identifiable information is included. Please note that this feature may mean that on rare occasions your dog's data will be uploaded via another user's Receiver while on other occasions data belonging to other dogs may be uploaded via your Receiver. Setting up your Heyrex Monitoring System You must go to www.heyrex.com/setup to complete your setup online. Please DO NOT setup or plug in any hardware until the online setup instructions advise you to do so. Step One: Create your account. Enter your details as the owner of the dog. Step Two: Set up your Receiver. 1. Screw the white aerial firmly into place on the side of the Receiver. 2. Connect the white network cable into a spare socket on your router/broadband modem. 3. Insert the other end of the cable into the Receiver network socket. 4. Plug the Receiver power adapter into a wall outlet. 5. Put the other end of the power cable into the end of the Receiver unit. 6. Watch the blue and green lights on the side of the Receiver, next to the aerial. During start up, the blue light will flash repeatedly, then the green light. Once the green light turns on (and stays on), your setup is complete. PLEASE NOTE: Any changes or modifications to the equipment could void your authority to operate the equipment under the laws of your country. 1. You must set up and use the Receiver correctly. i.e. lying flat with aerial pointing upwards. (see diagram) 2. You must use the power adaptor supplied. It is acceptable to use a replacement Category 5, 5e or 6 network cable. 3. You must use the aerial provided and attach it correctly. 4. The Receiver must be set up at least 20cm away from people and other electronic devices including your wireless router. 5. Do not attach any accessory, aerial or other device to the Receiver that has not been provided by Heyrex. Step Three: Enter your dog’s details into the sign-up portal www.heyrex.com [email protected] Step Four: Set up your biosensor. Remove the biosensor from the surround 1. Turn the biosensor capsule and casing over so you are looking at the back side (without the Heyrex logo). 2. At the top and bottom of the casing is a small horizontal gap. Use fingers to separate the two pieces of the casing which will release the white biosensor unit. 3. Lift the white biosensor capsule from the surround. Please answer the questions online and follow the instructions specific to your biosensor. Step Five: Attach the biosensor to your…

Text truncated - open the document above for the full version.

Cover Letter(s)

Heyrex FCC Confidentiality Request - Permanent Number: CF303 Version: V05 Date: 21-05-2012 (Permanent or also called long term confidentiality is the normal method to keep certain docuements confidential, and may apply to schematics, block diagrams, operational description and bill of materials.) To: Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Pursuant to 47 CFR Section 0.459(a) & (b), we, (the applicant / grantee) Company nameHeyrex Limited AddressPO. Box 17223, Karori City6147 Wellington CountryNew Zealand request for this certification filing under: Grantee CodeProduct Number FCC ID:RGZ-C7 to maintain permanent confidentiality for the following documents submitted within this application: (please cross what is applicable, or add other documents, provide the file name and description) ExhibitFile NameDescription xOperational Descriptionexplaining the functioning of the block diagram xBlock Diagramsshowing the systematic building blocks of the EUT xSchematics Diagramsshowing components, their values and interconnection Above materials crossed contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. We understand that pursuant to 47 CFR section 0.457(d)(1)(ii) disclosure of the applicant and all accompanying documentation will not be made before the date of the grant. The documents indicated as confidential above, are not publicly available elsewhere. Attestation: City and Country:Date:Name: (this must be a person) Function:Signature: (or official company stamp) Enschede, The Netherlands 2014-10-10Mark Koop (authorized) Manager

Cover Letter(s)

Heyrex FCC Short Term Confidentiality Request Number: CF313 Version: V01 Date: 21-05-2012 (With Short term confidentiality, a period of max. 180 days on certain additional exhibits are possible, such as internal/external photos, user manual can test setup photosbet. After expiration of the confidentiality period, these additional exhibits for short term confidentiality become visible in the FCC database for the internet public.) To: Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Pursuant to 47 CFR Section 0.459(a) & (b), we, (the applicant / grantee) Company nameHeyrex Limited AddressPO. Box 17223, Karori City6147 Wellington CountryNew Zealand request for this certification filing under: Grantee CodeProduct Number FCC ID:RGZ-C7 to maintain short term confidentiality for a period of 180 days for the following documents submitted within this application: (please cross what is applicable, or add other documents, provide the file name and description) ExhibitFile NameDescription xInternal photospictures showing internal views of the EUT Above materials crossed contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. We understand that pursuant to 47 CFR section 0.457(d)(1)(ii) disclosure of the applicant and all accompanying documentation will not be made before the date of the grant. The documents indicated as confidential above, are not publicly available elsewhere. Attestation: City and Country:Date:Name: (this must be a person) Function:Signature: (or official company stamp) Enschede, The Netherlands 2014-10-10Mark Koop (authorized) Manager

Cover Letter(s)

Motion sensor with frequency hopping transceiver

External Photos

External Photographs of the EUT front / left view back / right view

ID Label/Location Info

Label and location : 12380A-C7 : 12380A-C7 Model: C7 Model: C7

Internal Photos

Internal Photographs of the EUT

Test Report

Testing and certification of electronic and electric appliances, systems, installations and telecommunication systems TÜV Rheinland Nederland B.V. Eiberkamp 10 9351 VT Leek Telephone: +31 88 8887888 Telefax: +31 594 504804 E-mail: [email protected] Web: www.tuv.com Project number: 14062301.fcc01 Page 1 of 36 TEST REPORT CONCERNING THE COMPLIANCE OF A HEYREX COLLAR BIOSENSOR CAPSULE V7 ANIMAL BIOMETRICS MONITORING DEVICE (SPREAD SPECTRUM TRANSMITTER) BRAND HEYREX, MODEL C7 WITH 47 CFR PART 15 (10-1-13 Edition) AND RSS-GEN (ISSUE 3, DECEMBER 2010) AND RSS-210 (ISSUE 8, DECEMBER 2010) 14062301.fcc01 September 26, 2014 FCC listed Industry Canada R&TTE, LVD, EMC Notified Body : : : 90828 2932G-2 1856 Test specification(s): Description of EUT: Manufacturer: Brand mark: Model: FCC ID: IC: FCC Part 15, RSS-Gen, RSS-210 Spread Spectrum Transmitter Heyrex Heyrex C7 RGZ-C7 12380A-C7 Project number : 14062301.fcc01 Page 2 of 36 MEASUREMENT/TECHNICAL REPORT Brand: Heyrex Model: C7 FCC ID: RGZ-C7 IC: 12380A-C7 This report concerns: Original grant/certification Class 1 permissive change Verification Equipment type: Spread Spectrum Transmitter (DSS) Report prepared by: Name : Richard van der Meer Company name : TÜV Rheinland Nederland B.V. Address : Eiberkamp 10 Postal code/city : 9351VT Leek Mailing address : P.O. Box 37 Postal code/city : 9350 AA Leek Country : The Netherlands Telephone number : + 31 594 505 005 Telefax number : + 31 594 504 804 E-mail : [email protected] The data taken for this test and report herein was done in accordance with 47 CFR Part 15 (10-1-13 Edition), RSS- Gen (issue 3, December 2010) and RSS-210 (Issue 8, December 2010) and the measurement procedures of FCC Public Notice DA 00-705. TÜV Rheinland Nederland B.V. at Leek, The Netherlands, certifies that the data is accurate and contains a true representation of the emission profile of the Equipment Under Test (EUT) on the date of the test as noted in the test report. I have reviewed the test report and find it to be an accurate description of the test(s) performed and the EUT so tested. Date: September 26, 2014 Signature: O. Hoekstra Senior Engineer Telecom TÜV Rheinland Nederland B.V. Test specification(s): Description of EUT: Manufacturer: Brand mark: Model: FCC ID: IC: FCC Part 15, RSS-Gen, RSS-210 Spread Spectrum Transmitter Heyrex Heyrex C7 RGZ-C7 12380A-C7 Project number : 14062301.fcc01 Page 3 of 36 Description of test item Test item Product description (by client) : Spread Spectrum Transmitter (DSS) Motion sensor with frequency hopping transceiver Manufacturer : Heyrex Brand : Heyrex Model : C7 Serial number : Unindentified test sample Revision : -- Applicant information Applicant's representative : Mr. M. Koop Company : Teleconformity Address : Constructieweg 1 Postal code : 7451PS City : Holten Country : The Netherlands Telephone number : +31 53 4785267 Telefax number : +31 84 8362566 Test(s) performed Location : Leek Test(s) started : August 07, 2014 Test(s) completed : September 25, 2014 Purpose of test(s) : Equipment Authorization (Original grant/certification) Test specification(s) : FCC 47 CFR Part 15, Subpart C, Section 15.247 (10-1-13 Edition) and RSS-Gen (issue 3, December 2010) and RSS-210 (Issue 8, December 2010) FCC Public Notice DA 00-705 march 30, 2000 Test engineer(s) : R. van der Meer Report written by : R. van der Meer Report date : September 26, 2014 This report shall not be reproduced, except in full, without the written permission of TÜV Rheinland Nederland B.V. The test results relate only to the item(s) tested. Test specification(s): Description of EUT: Manufacturer: Brand mark: Model: FCC ID: IC: FCC Part 15, RSS-Gen, RSS-210 Spread Spectrum Transmitter Heyrex Heyrex C7 RGZ-C7 12380A-C7 Project number : 14062301.fcc01 Page 4 of 36 Table of contents 1 General information. .............................................................................................................................................. 5 1.1 Product description. ........................................................................................................................................ 5 1.1.1 Introduction. ............................................................................................................................................ 5 1.2 Related submittal(s) and/or Grant(s). ............................................................................................................. 5 1.2.1 General. .................................................................................................................................................. 5 1.3 Tested system details. .................................................................................................................................... 6 1.3.1 Description of input and output ports. ..................................................................................................... 7 1.4 Test methodology. .......................................................................................................................................... 8 1.5 Test facility. .................................................................................................................................................... 8 1.6 Test conditions. .............................................................................................................................................. 8 2 System test configuration. ..................................................................................................................................... 9 2.1 Justification. .................................................................................................................................................... 9 2.2 EUT mode of operation. ................................................................................................................................. 9 2.3 Special accessories. .................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Testing and certification of electronic and electric appliances, systems, installations and telecommunication systems TÜV Rheinland Nederland B.V. Eiberkamp 10 9351VT Leek The Netherlands Telephone: +31 594 505005 Telefax: +31 594 504804 Internet: www.tuv.com/nl E-mail: [email protected] Project number: 14062301.p01 Page 1 of 5 PHOTOGRAPHS OF THE TESTSETUP OF A HEYREX COLLAR BIOSENSOR CAPSULE V7 ANIMAL BIOMETRICS MONITORING DEVICE (SPREAD SPECTRUM TRANSMITTER) BRAND HEYREX, MODEL C7 14062301.p01 September 26, 2014 FCC listed Industry Canada R&TTE, LVD, EMC Notified Body : : : 90828 2932G-2 1856 Test specification(s): Description of EUT: Manufacturer: Brand mark: Model: FCC ID: IC: FCC Part 15, RSS-Gen, RSS-210 Spread Spectrum Transmitter Heyrex Heyrex C7 RGZ-C7 12380A-C7 Project number: 14062301.p01 Page 2 of 5 Description of test item Test item : Spread Spectrum Transmitter (DSS) Manufacturer : Heyrex Brand : Heyrex Model : C7 Serial number : Unindentified test sample Revision : -- Applicant information Applicant's representative : Mr. M. Koop Company : Teleconformity Address : Constructieweg 1 Postal code : 7451PS City : Holten Country : The Netherlands Telephone number : +31 53 4785267 Telefax number : +31 84 8362566 Report written by : R. van der Meer Report date : September 26, 2014 Test specification(s): Description of EUT: Manufacturer: Brand mark: Model: FCC ID: IC: FCC Part 15, RSS-Gen, RSS-210 Spread Spectrum Transmitter Heyrex Heyrex C7 RGZ-C7 12380A-C7 Project number: 14062301.p01 Page 3 of 5 Table of contents 1 PHOTOGRAPHS OF THE TESTSETUP. ....................................................................................................................... 4 1.1 RADIATED EMISSIONS..................................................................................................................................................... 4 1.1.1 Radiated emissions setup E-field. ..................................................................................................................... 4 1.1.2 Radiated emissions setup detail, front and back view ................................................................................... 5 Test specification(s): Description of EUT: Manufacturer: Brand mark: Model: FCC ID: IC: FCC Part 15, RSS-Gen, RSS-210 Spread Spectrum Transmitter Heyrex Heyrex C7 RGZ-C7 12380A-C7 Project number: 14062301.p01 Page 4 of 5 1 Photographs of the testsetup. 1.1 Radiated emissions. 1.1.1 Radiated emissions setup E-field. Test specification(s): Description of EUT: Manufacturer: Brand mark: Model: FCC ID: IC: FCC Part 15, RSS-Gen, RSS-210 Spread Spectrum Transmitter Heyrex Heyrex C7 RGZ-C7 12380A-C7 Project number: 14062301.p01 Page 5 of 5 1.1.2 Radiated emissions setup detail, front and back view

Contact Information

Applicant

Mark C Solly(Mr)
[email protected]+64 4 476 8849Fax: +64 4 476 2168

Test Firm

TUV Rheinland Nederland B.V.Ties E. T Koning
[email protected]31-594-505-005Fax: 31-594-504-804

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.46 GHz670.00 µW
Confidentiality
Long Term

Other Applications from Heyrex Limited

FREQUENCY HOPPING SPREAD SPECTRUM TRANSCEIVER - FCC ID RGZ-R3 - Heyrex Limited
RGZ-R3

FREQUENCY HOPPING SPREAD SPECTRUM TRANSCEIVER

Mar 11, 2013

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
FREQUENCY HOPPING SPREAD SPECTRUM TRANSCEIVER - FCC ID RGZ-C6 - Heyrex Limited
RGZ-C6

FREQUENCY HOPPING SPREAD SPECTRUM TRANSCEIVER

Mar 11, 2013

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter