Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Operation Manual Read the product’s instructions before using the product. The product’s warranty is included inside the product’s Operation Manual. Breast Liner BL Co., Ltd. Address: 553-25, Sinsa-Dong, Gangnam-Gu, Seoul, Korea Developed by Cyber Tree Co., Ltd. Manufactured by Moa Moa Korea Inquiry & FAQ Tel: 82 2 546 3116, Fax: 82 2 546 9808 CONTENTS Company Introduction Components / Remote Control Special Features The Six Typical Shapes of Women’s Breasts Operation Instructions Common Problems and Their Solutions / FAQ Caution / Safety Instructions Product Specifications Warranty Introduction of the Developer Consumer satisfaction depends upon the value of the products they have purchased and who makes these products will decide the level of the product’s value. In other words, consumer satisfaction is determined by the quality and performance of a product. My job is to teach university students, so I may not be fully aware of the company called the Cyber Tree Co., Ltd. However, I was more than willing to write this recommendation for the company, when I was asked, for two reasons. First, I believe a company’s future can be judged by its CEO. Since April, 2003, the CEO of the Cyber Tree has been a student of mine in my top management courses. I was very impressed by his willingness and initiative to learn new knowledge and build a wider human network despite the numerous difficulties his business had to face at that time. He also has been one of my best students because he was highly motivated, creative and knew how to work well with other people. Guided by this young and energetic CEO, I strongly believe this company will see a bright future and the quality of their products can be assured. And, second the firm’s other products are being exported to foreign countries such as the United States, Canada and Australia, with local branch offices operating in Canada and Australia. This represents the fact that the products are competitive against similar goods from all over the world. This type of situation cannot be achieved without a firm foundation built on advanced quality, manpower and management. The consumers in North America have very high standards when it comes to quality in their purchased products and it is apparent that the Cyber Tree company is actually meeting those standards. I offer my sincere hope for the success of the that BL company and it will prove itself again in a new domain. Go Wan Seok Doctor of Business Administration Hankuk University of Foreign Studies <2> Design The breast massage machine, the “BL” must be friendly, neat and pretty, as well as it being convenient with a high performance ability for its users. The Breast Liner (BL) was designed by Song Minhun, an Art Director / Representative of Moto Design. The February edition of monthly design magazine explains the concept of the Breast Liner, “Song Minhun is no longer just a famous Korean designer. The world is his stage and his works are considered one of the worlds finest. He built this outstanding industrial design company (Breast Liner BL) that has been leading the design trends in Korea for the last 17 years.” Mr. Song is known to be the nation’s best industrial designer. “If it’s to be a tool to protect and enhance the beauty of women, it must be designed to have the aesthetic value that can create sublime beauty, as well as, also protecting the individual. Only those who can understand beauty can make products that can create beauty. All designs come from human life and return to human life again. We can feel it from any action, feature, various shocks and social phenomena. Constant questioning and imagining is the key to drawing better designs, thus making beauty out of nothing,” according to Mr. Song when asked about his idea about design by Monthly Design. The Breast Liner is one of his greatest masterpieces. <3> Comments From a Plastic Surgeon It is already well known, even within academic circles, that frequent massaging will enlarge a breast. Thinking more about it, it is the female hormone that is stimulated by a massage that will make breasts larger. Massage stimulates the secretion of female hormones that are not well secreted for various reasons, such as a person’s incorrect posture. It will take some time to enlarge breasts by only applying a massage to them. The only way to enlarge one’s breasts in a short period of time is through plastic surgery. However, there are many who can make their breasts larger and more beautiful by simply applying a constant massage to them, instead of relying on plastic surgery. For example, if the massage is done spirally toward the inner area of the breasts while pushing the flesh of the upper arms and armpits to that inner breast area, this will lift up drooping breasts and make them look bigger than they really are. This method will also help the nipples. I would recommend this product called the Breast Liner to those who just had breast surgery or those individuals with a low adaptability to surgery. Especially after going through surgery, it is very important to provide a constant massage to the breast area because it will improve its/their shape and make it/them look more natural. With a variety of traditional massage skills conjoined with state-of-the-art technology, the Breast Liner has been designed to be used at anytime and anywhere. Breasts themselves have no muscles that can directly move them. So, breasts can only borrow external energy to stimulate the secretion of the above-mentioned hormones. The Breast Liner is the answer for providing the needed external energy. Adding to its unique design and high performance capabilities, the Breast Liner can be operated with a remote control. The BL is safe, it is convenient and it is good looking. Dr. Jeong Seong-il Specialized in Plastic Surgery Director of Top Surgery Hospital Director of Beijing SK Hospital <4> Quick Tips for the Breasts If one has too much fat, they may have beautiful breasts. A se…
Text truncated - open the document above for the full version.
BLOCK DIAGRAM zReceiver Filter Amp. U102U103Motor ∿∿ 23.26429MHz4.0MHz DC Input
FCC ID. : RLRRCWM300XBL3150B Report No.: E04OR-009 ONETECH Testing & Evaluation Lab. FCC ID. : RLRRCWM300XBL3150B Report No.: E04OR-009 ONETECH Testing & Evaluation Lab. FCC ID. : RLRRCWM300XBL3150B Report No.: E04OR-009 ONETECH Testing & Evaluation Lab. FCC ID. : RLRRCWM300XBL3150B Report No.: E04OR-009 ONETECH Testing & Evaluation Lab. FCC ID. : RLRRCWM300XBL3150B Report No.: E04OR-009 ONETECH Testing & Evaluation Lab. FCC ID. : RLRRCWM300XBL3150B Report No.: E04OR-009 ONETECH Testing & Evaluation Lab. FCC ID. : RLRRCWM300XBL3150B Report No.: E04OR-009 ONETECH Testing & Evaluation Lab.
FCC ID. : RLRCWM300XBL3150B Report No.: E04OR-009 ONETECH Testing & Evaluation Lab. IDENTIFICATION LABEL: PROPOSED FCC ID LABEL Due to the product size, only the FCC ID shall be permanently affixed to the bottom side of the equipment and other information shall be placed in the instruction manual. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operations. Made in Korea FCC ID : RLRCWM300XBL3150B FCC ID AREA
FCC ID. : RLRRCWM300XBL3150B Report No.: E04OR-009 ONETECH Testing & Evaluation Lab. FCC ID. : RLRRCWM300XBL3150B Report No.: E04OR-009 ONETECH Testing & Evaluation Lab. FCC ID. : RLRRCWM300XBL3150B Report No.: E04OR-009 ONETECH Testing & Evaluation Lab. FCC ID. : RLRRCWM300XBL3150B Report No.: E04OR-009 ONETECH Testing & Evaluation Lab. FCC ID. : RLRRCWM300XBL3150B Report No.: E04OR-009 ONETECH Testing & Evaluation Lab. FCC ID. : RLRRCWM300XBL3150B Report No.: E04OR-009 ONETECH Testing & Evaluation Lab. FCC ID. : RLRRCWM300XBL3150B Report No.: E04OR-009 ONETECH Testing & Evaluation Lab. FCC ID. : RLRRCWM300XBL3150B Report No.: E04OR-009 ONETECH Testing & Evaluation Lab.
Page 1 of 12 FCC ID. : RLRCWM300XBL3150B Report No. : E04OR-009 This report shall not be reproduced except in full without our written approval. FCC-004 (Rev.0) HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Kyunggi-Do, 462-121, Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 426-1 Daessangryung-Ri, Chowol-Myun, Kwangju-Kun, Kyunggi-Do 464-860 Korea. (TEL: 82-31-765-8289 FAX: 82-31-766-2904) ONETECH Testing & Evaluation Lab. ELECTROMAGNETIC EMISSION C OMPLIANCE REPORT FOR SUPERHETRODYNE RECEIVER Test Report No. : E04OR-009 Applicant : Cybertree Co., Ltd. Address : 546-9, Sang2-Dong, Wonmi-Gu, Bucheon-Si, Gyeonggi-Do, Korea Manufacturer : Cybertree Co., Ltd. Address : 546-9, Sang2-Dong, Wonmi-Gu, Bucheon-Si, Gyeonggi-Do, Korea Type of Equipment : BREAST LINEAR FCC ID : RLRCWM300XBL3150B Model Name : CWM-300B Serial number : N/A Total page of Report : 12 pages (including this page) Date of Incoming : September 20, 2004 Date of issuing : October 6, 2004 SUMMARY The equipment complies with the regulation; FCC PART 15 SUBPART B §15.101 This test report contains only the result of a single test of the sample supplied for the examination. It is not a general valid assessment of the features of the respective products of the mass-production. Prepared by: Reviewed by: G. W. Lee/ Chief Engineer Y. K. Kwon/ Director EMC Div. EMC Div. ONETECH Corp. ONETECH Corp. Page 2 of 12 FCC ID. : RLRCWM300XBL3150B Report No. : E04OR-009 This report shall not be reproduced except in full without our written approval. FCC-004 (Rev.0) HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Kyunggi-Do, 462-121, Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 426-1 Daessangryung-Ri, Chowol-Myun, Kwangju-Kun, Kyunggi-Do 464-860 Korea. (TEL: 82-31-765-8289 FAX: 82-31-766-2904) ONETECH Testing & Evaluation Lab. CONTENTS Page 1. VERIFICATION OF COMPLIANCE ............................................................................................................................3 2. GENERAL INFORMATION...........................................................................................................................................4 2.1 PRODUCT DESCRIPTION................................................................................................................................................4 2.2 RELATED SUBMITTAL(S) / GRANT(S)...........................................................................................................................4 2.3 TEST SYSTEM DETAILS.................................................................................................................................................5 2.4 TEST METHODOLOGY...................................................................................................................................................5 2.5 TEST FACILITY..............................................................................................................................................................5 3. SYSTEM TEST CONFIGURATION..............................................................................................................................5 3.1 JUSTIFICATION..............................................................................................................................................................5 3.2 EUT EXERCISE SOFTWARE...........................................................................................................................................5 3.3 EQUIPMENT MODIFICATIONS.......................................................................................................................................5 3.4 CONFIGURATION OF TEST SYSTEM..............................................................................................................................6 4. PRELIMINARY TEST .....................................................................................................................................................6 4.1 AC POWER LINE CONDUCTED EMISSIONS TESTS........................................................................................................6 4.2 RADIATED EMISSIONS TESTS........................................................................................................................................6 5. FINAL RESULT OF MEASURMENT ...........................................................................................................................7 5.1 CONDUCTED EMISSION TEST........................................................................................................................................7 5.2 RADIATED EMISSION TEST_RECEIVING MODE...........................................................................................................9 5.3 RADIATED EMISSION TEST_BATTERY CHARGING MODE...........................................................................................9 6. FIELD STRENGTH CALCULATION .........................................................................................................................10 7. LIST OF TEST EQUIPMENT.......................................................................................................................................12 Page 3 of 12 FCC ID. : RLRCWM300XBL3150B Report No. : E04OR-009 This report shall not be reproduced except in full without our written approval. FCC-004 (Rev.0) HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Kyunggi-Do, 462-121, Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 426-1 Daessangryung-Ri, Chowol-Myun, Kwangju-Kun, Kyunggi-Do 464-860 Korea. (TEL: 82-31-765-8289 FAX: 82-31-766-2904) ONETECH Testing & Evaluation Lab. 1. VERIFICATION OF COMPLIANCE APPLICANT : Cybertree Co., Ltd. ADDRESS : 546-9, Sang2-Dong, Wonmi-Gu, Bucheon-Si, Gyeonggi-Do, Korea CONTACT PERSON : Beom Mo, Jung / Direct…
Text truncated - open the document above for the full version.
FCC ID. :RLRCWM300XBL3150B Report No.: E04OR-009 ONETECH Testing & Evaluation Lab. FCC ID. :RLRCWM300XBL3150B Report No.: E04OR-009 ONETECH Testing & Evaluation Lab.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | 315 MHz - 315 MHz | - |

Pager
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Breast Linear (Remote Controller)
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Digital Wireless Mobile Headset
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Digital Wireless Mobile Base Unit
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified