Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Atlas RFID Reader Application The Atlas Reader is specifically configured for an in office application. It is designed for a client check in station both at the front desk and in the treatment area. Features - Features a beeper - Small outline just 3.00 x 4.00 x 1.38 in. / 76.20 x 101.60 x 35.05 mm - Powered by USB connection - CE and FCC Standard - RoHS Compliant Theory of Operation The reader generates a 125 kHz inductive field and extends 50-100mm distance beyond the reader module. When a card or keyfob is placed within the area of the reader module, it draws power from this field and providing the field is of sufficient strength the internal microcircuits contained in the card or keyfob begin to function. Data is transferred from the card or keyfob by means of amplitude modulation. Proximity Testing and Connecting: The reader is connected to a host PC via USB cable. The USB model connects directly to USB port and sends as keystrokes. No drivers needed for Windows XP, Vista, 7 or 8 applications. Specifications Read range : 10-100 mm Dimensions (L x W x H) (in / mm) 3.00 x 4.00 x 1.38 in. / 76.20 x 101.60 x 35.05 mm Material: Flame Retardant ABS UL94-5VA Power 5 VDC(4.5~5.5V); 55mA Max Antenna integrated antenna Operation temperature -20 to +60ยฐC Interface USB 2.0 Transmit Frequency: 125 kHz Reader Reads any tag with EM41xx protocol Transponder: Read Only Compliance Information FCC Compliance This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device has been designed to operate with the antenna provided with it. This device is not designed to work with any other antennas. To reduce radio interference to other users, the antenna type and its gain is chosen such that the equivalent isotropically radiated power (EIRP) is not more than permitted for successful communication. Customer Support: Atlas Support personnel are trained specifically on the Atlas Chiropractic Software. On occasion, they are able to assist with general computer support (networking, antivirus, configuration). Atlas recommends that issues outside of the scope of Atlas Support be directed to the appropriate Support professional. A qualified, onsite IT technician can provide you with the most accurate information to resolve your Technical Issues. Atlas Support may be able to assist your technician in resolving issues regarding your Operating System or System Maintenance, to help facilitate the proper function of Atlas. FCC STATEMENT 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. CAUTION:
FCC ID: RMP- DESKTOP Page 17 o f 20 Anbotek Compliance Laboratory Limited Report No. 201212769F Figure 1 The EUT-Overall View Figure 2 The EUT-Side View FCC ID: RMP- DESKTOP Page 18 o f 20 Anbotek Compliance Laboratory Limited Report No. 201212769F Figure 3 The EUT-Side View
The proposed Label Location on EUT Proposed FCC Label Location Proposed Label Location on EUT The EUT-Back View/Proposed FCC Label Location
FCC ID Label Sample for FCC ID: RMP-DESKTOP FCC ID: RMP-DESKTOP This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation.
FCC ID: RMP- DESKTOP Page 19 o f 20 Anbotek Compliance Laboratory Limited Report No. 201212769F Figure 4 The EUT-Inside View Figure 5 PCB of the EUT- Front View Figure 6 FCC ID: RMP- DESKTOP Page 20 o f 20 Anbotek Compliance Laboratory Limited Report No. 201212769F PCB of the EUT- Back View
FCC ID: RMP-DESKTOP Page 1 o f 20 Anbotek Compliance Laboratory Limited Report No. 201212769F FCC PART 15B TEST REPORT On Behalf of Atlas Chiropractic System Inc ATLAS RFID READER Model No.: DESKTOP ATLAS_7.22 Prepared for : Atlas Chiropractic System Inc Address : 30 Brock St. East, Tillsonburg, Ontario, Canada, N4G 1Z5 Prepared By : Anbotek Compliance Laboratory Limited Address : 1/F, 1/Build, SEC Industrial Park, No. 4 Qianhai Road, Nanshan District, Shenzhen, 518054, China Tel: (86) 755-26066544 Fax: (86) 755-26014772 Report Number : 201212769F Date of Test : Dec.20~25, 2012 Date of Report : Dec.26, 2012 FCC ID: RMP-DESKTOP Page 2 o f 20 Anbotek Compliance Laboratory Limited Report No. 201212769F TABLE OF CHONTENTS Description Page Test Report Verification 1. GENERAL INFORMATION ............................................................................................................... 4 1.1. Description of Device (EUT) ..........................................................................................................................4 1.2. Auxiliary Equipment Used during Test ..........................................................................................................5 1.3. Description of Test Facility.............................................................................................................................6 1.4. Measurement Uncertainty ...............................................................................................................................6 1.5. Test Summary .................................................................................................................................................6 2. POWER LINE CONDUCTED MEASUREMENT ............................................................................ 7 2.1. Test Equipment ...............................................................................................................................................7 2.2. Block Diagram of Test Setup ..........................................................................................................................7 2.3. Power Line Conducted Emission Measurement Limits (FCC Part 15 Subpart B Class B) ............................7 2.4. Configuration of EUT on Measurement..........................................................................................................8 2.5. Operating Condition of EUT...........................................................................................................................8 2.6. Test Procedure.................................................................................................................................................8 2.7. Power Line Conducted Emission Measurement Results.................................................................................8 3.RADIATED EMISSION MEASUREMENT...................................................................................... 11 3.1. Test Equipment .............................................................................................................................................11 3.2. Block Diagram of Test Setup ........................................................................................................................11 3.3. Radiated Emission Limit (Subpart B Class B) ..............................................................................................12 3.4. EUT Configuration on Measurement ............................................................................................................12 3.5. Operating Condition of EUT.........................................................................................................................12 3.6. Test Procedure...............................................................................................................................................12 3.7. Radiated Emission Measurement Results .....................................................................................................12 4. PHOTOGRAPH .............................................................................................................................. 15 4.1. Photo of Power Line Conducted Emission Test............................................................................................15 4.2. Photo of Radiated Emission Test ..................................................................................................................15 APPENDIX I (Photos of EUT) (4 Pages) FCC ID: RMP-DESKTOP Page 3 o f 20 Anbotek Compliance Laboratory Limited Report No. 201212769F TEST REPORT VERIFICATION Applicant : Atlas Chiropractic System Inc Manufacturer : Chronocom Electronique EUT : ATLAS RFID READER Model No. : DESKTOP ATLAS_7.22 Rating : DC 5V Trade Mark : N.A. Measurement Procedure Used: FCC Rules and Regulations Part 15 Subpart B 2010 & FCC / ANSI C63.4-2009 The device described above is tested by Anbotek Compliance Laboratory Limited To determine the maximum emission levels emanating from the device. The maximum emission levels are compared to the FCC Part 15 Subpart B Class B limits both radiated and conducted emissions. The measurement results are contained in this test report and Anbotek Compliance Laboratory Limited Is assumed full responsibility for the accuracy and completeness of these measurements. Also, this report shows that the Equipment Under Test (EUT) is to be technically compliant with the FCC requirements. This report applies to above tested sample only. This report shall not be reproduced in part without written approval of Anbotek Compliance Laboratory Limited Date of Test : Dec.20~25, 2012 Prepared by : (Engineer/ Well Wang) Reviewer : (Project Manager/ Jerry Du) Approved & Authorized Signer : (Manager/ Tom Chen) FCC ID: RMP-DESKTOP Page 4 o f 20 Anbotek Compliance Laboratory Limited Report No. 201212769F 1. GENERAL INFORMATION 1.1. Description of Device (EUT) Description : ATLAS RFID READER โฆ
Text truncated - open the document above for the full version.
FCC ID: RMP- DESKTOP Page 15 o f 20 Anbotek Compliance Laboratory Limited Report No. 201212769F 4. PHOTOGRAPH 4.1. Photo of Power Line Conducted Emission Test 4.2. Photo of Radiated Emission Test
Rietven 31 ยท Enschede, Overyssel ยท Netherlands
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | - | - |