
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Neutron Engineering Inc. Project No.: 1106C018 Page 3 of 8 1106C018 1106C018 Neutron Engineering Inc. Project No.: 1106C018 Page 3 of 8 1106C018 1106C018
Neutron Engineering Inc. Project No.: 1106C018 Page 4 of 8 1106C018 1106C018 Neutron Engineering Inc. Project No.: 1106C018 Page 4 of 8 1106C018 1106C018 Neutron Engineering Inc. Project No.: 1106C018 Page 5 of 8 1106C018 1106C018 Neutron Engineering Inc. Project No.: 1106C018 Page 5 of 8 1106C018 1106C018 Neutron Engineering Inc. Project No.: 1106C018 Page 6 of 8 1106C018 1106C018 Neutron Engineering Inc. Project No.: 1106C018 Page 6 of 8 1106C018 1106C018 Neutron Engineering Inc. Project No.: 1106C018 Page 7 of 8 1106C018 1106C018 Neutron Engineering Inc. Project No.: 1106C018 Page 7 of 8 1106C018 1106C018 Neutron Engineering Inc. Project No.: 1106C018 Page 8 of 8 1106C018 1106C018 Neutron Engineering Inc. Project No.: 1106C018 Page 8 of 8 1106C018 1106C018
Neutron Engineering Inc. Report No.: NEI-FCCE-1-1106C018 Page 1 of 20 FCC Test Report FCC ID: ROC-RD8625R This report concerns (check one) : Original Class I Change Issued Date : Jun. 17, 2011 Project No. : 1106C018 Equipment : RECORDABLE PARTY DOORBELL Model Name : RD8625R Applicant : HPI Hong Kong Limited Address : Unit 1715-18, 17/F., Corporation Square 8 Lam Lok Street Kowloon Bay Hong Kong Manufacturer : General Tech Electronics Ltd Address : No.3 Gongyequ Baishegang,Chang Ping Town Dongguan, Guangdong, China PRC Tested by: Neutron Engineering Inc. EMC Laboratory Date of Receipt: Jun. 02, 2011 Date of Test: Jun. 02, 2011 ~ Jun. 16, 2011 Testing Engineer : (Ivan Cao) Technical Manager : (Leo Hung) Authorized Signatory : (Steven Lu) NEUTRON ENGINEERING INC. No.3,Jinshagang 1st Road, ShiXia, Dalang Town, Dong Guan, China.523792 TEL : +86-769-8318-3000 FAX : +86-769-8319-6000 Neutron Engineering Inc. Report No.: NEI-FCCE-1-1106C018 Page 2 of 20 Declaration Neutron represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML) of CHINA, or National Institute of Standards and Technology (NIST) of U.S.A. Neutron's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. Neutronshall have no liability for any declarations, inferences o r generalizations drawn by the client or others from Neutron issued reports. Neutron’s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and Neutron-self, extracts from the test report shall not be reproduced except in full with Neutron’s authorized written approval. Neutron’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Neutron Engineering Inc. Report No.: NEI-FCCE-1-1106C018 Page 3 of 20 Table of Contents Page 1 . VERIFICATION 4 2 . SUMMARY OF TEST RESULTS 5 2.1 TEST FACILITY 6 2.2 MEASUREMENT UNCERTAINTY 6 3 . GENERAL INFORMATION 7 3.1 GENERAL DESCRIPTION OF EUT 7 3.2 DESCRIPTION OF TEST MODES 8 3.3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 9 3.4 DESCRIPTION OF SUPPORT UNITS 10 4 . EMC EMISSION TEST 11 4.1 CONDUCTED EMISSION MEASUREMENT 11 4.1.1 POWER LINE CONDUCTED EMISSION 11 4.1.2 MEASUREMENT INSTRUMENTS LIST 11 4.1.3 TEST PROCEDURE 12 4.1.4 DEVIATION FROM TEST STANDARD 12 4.1.5 TEST SETUP 12 4.1.6 EUT OPERATING CONDITIONS 12 4.1.7 TEST RESULTS 13 4.2 RADIATED EMISSION MEASUREMENT 14 4.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT 14 4.2.2 MEASUREMENT INSTRUMENTS LIST 15 4.2.3 TEST PROCEDURE 15 4.2.4 DEVIATION FROM TEST STANDARD 15 4.2.5 TEST SETUP 16 4.2.6 EUT OPERATING CONDITIONS 16 4.2.7 TEST RESULTS (30-1000 MHZ) 17 4.2.8 TEST RESULTS (ABOVE 1000 MHZ) 19 Neutron Engineering Inc. Report No.: NEI-FCCE-1-1106C018 Page 4 of 20 1. VERIFICATION E q u i p m e n t : RECORDABLE PARTY DOORBELL Brand Name : N/A Model Name : RD8625R A p p l i c a n t : HPI Hong Kong Limited F a c t o r y : General Tech Electronics Ltd A d d r e s s : Gongyequ Baishegang,Chang Ping Town Dongguan, Guangdong, China PRC Date of Test : Jun. 02, 2011 ~ Jun. 16, 2011 Standards : FCC Part 15, Subpart B ANSI C63.4-2003 The above equipment has been tested and found compliance with the requirement of the relative standards by Neutron Engineering Inc. EMC Laboratory. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. NEI-FCCE-1-1106C018) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of NVLAP and TAF according to the ISO-17025 quality assessment standard and technical standard(s). Neutron Engineering Inc. Report No.: NEI-FCCE-1-1106C018 Page 5 of 20 2. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: EMC Emission Standard Test Item Limit Judgment Remark Conducted Emission - N/A Note(1) FCC Part15, Subpart B Radiated Emission Class B PASS NOTE: (1) ” N/A” denotes test is not applicable in this Test Report. (2) Test sample function is only receiver and used new battery. Neutron Engineering Inc. Report No.: NEI-FCCE-1-1106C018 Page 6 of 20 2.1 TEST FACILITY The test facilities used to collect the test data in this report is DG-C01/DG-CB08at the location of No.3,Jinshagang 1st Road, ShiXia, Dalang Town,Dong Guan, China.523792. 2.2 MEASUREMENT UNCERTAINTY Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the EUT as specified in CISPR 16-4-2: The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95%。 A. Conducted Measurement : Test Site Method Measurement Frequency Range U,(dB) NOTE DG-C01 CISPR 150 KHz ~ 30MHz 1.94 B. Radiated Measurement : Test Site Method Measurement Frequency Range Ant. H / V U,(dB) NOTE 30MHz ~ 1000MHz V 3.57 30MHz ~ 1000MHz H 3.96 1GHz~18GHz V 3.07 DG-CB08 CISPR 1GHz~18GHz H 3.62 Neutron Engineering Inc. Report No.: NEI-FCCE-1-1106C018 Page 7 of 20 3. GENERAL INFORMATION 3.1 GENERAL DESCRIPTION OF EUT Equipment RECORDABLE PARTY DOORBELL Brand Name N/A Model Name RD8625R FCC ID ROC-RD8625R Model Difference N/A OEM Brand/Model Name N/A Product Description The EUT is a RECORDABLE PA…
Text truncated - open the document above for the full version.
Neutron Engineering Inc. Report No.: NEI-ICP-1-1106C018 Page 21 of 21 5. EUT TEST PHOTO Radiated Measurement Photos Neutron Engineering Inc. Report No.: NEI-ICP-1-1106C018 Page 21 of 21 5. EUT TEST PHOTO Radiated Measurement Photos
No.3,Jinshagang 1st Rd, ShiXia,Dalang Town · Dongguan · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | 433.92 MHz - 433.92 MHz | - |

RECORDABLE PARTY DOORBELL
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Holiday Doorbell (433MHz Rx)
Equipment Class
CRR - Superregenerative Receiver
Fright Doorbell (433MHz Rx)
Equipment Class
CRR - Superregenerative Receiver
Fright Doorbell (433.9MHz Tx)
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Holiday Doorbell (433.9MHz Tx)
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter