FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Avanti Hearth Products/
  3. RRX-AHP304R2T

RRX-AHP304R2TBuilt-In Electric Fireplace Thermo Remote Control

Avanti Hearth Products
Built-In Electric Fireplace Thermo Remote Control - FCC ID RRX-AHP304R2T - Avanti Hearth Products
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
May 10, 2004
Application Purpose
Original Equipment
Date of Application
May 10, 2004
Equipment Note
Built-In Electric Fireplace Thermo Remote Control
Frequency Range
433.92000000 - 433.92000000
Company
Avanti Hearth Products
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Operational Description

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Avanti Hearth Products Installation and operating manual Model AHP304R2—Thermo Remote system Product Description The Avanti remote system described here is designed with the most up to date technology to provide a reliable radio frequency product that does not need normal household current to function. The unique patent pending code switch system using just 16 codes combined with a higher operating frequency (433.92 MHz) allows the user to set operating codes for maximum flexibility with a minimum of interference. This is especially important when more than one remote system is used in a dwelling. 1. Low Battery Power. Replace Batteries 2. Clock- current time – AM or PM setting 3. Flame – Indicates main burner in operation 4. Room-Shows CURRENT room temperature 5. F-indicates temperature in Fahrenheit or C for Celsius temperature reading 6. Time-When timer is programmed; this icon indicates time left before system shuts down. Maximum of 9 hours 7. Mode-Controls function of unit. ON means the system is on, thermostatically or manually. OFF indicates system is off. THERMO indicates system will cycle automatically based on programming settings. LCD DISPLAY When transmitter batteries are installed, the LCD screen will display the information shown in the diagram to the right. NOTE: improperly installed batteries will cause the transmitter not working. Setup Note: The Avanti transmitter contains a thermostat designed To monitor temperature changes for the system. Due to the sensitive Nature of the components, allow the transmitter to remain in the room Where it will be installed until it reaches room temperature. Always Allow 15-20 minutes for the transmitter to adjust from a cold room Before the LCD readings are used for programming the system. 1 The transmitter uses 2-AAA (1.5V) batteries. Alkaline batteries are recommended for long life and peak performance. Insert batteries in the back of the housing by opening the battery compartment cover. Make sure the batteries are positioned with the (+) and (-) markings in the correct position. Upon battery installation, the LCD display will show the icons pictured on the LCD diagram. NOTE: Icon does not appears on the screen, check battery positioning. Reversed batteries transmitter will not work. Check condition of batteries and repeat process if necessary. NOTE: If the transmitter is taken from a cold storage area, it can take up to 20 minutes for the unit to acclimate to the new temperature. Allow time for proper temperature readings to appear when this condition occurs. IMPORTANT: Always follow appliance manufacturers installation manual when installing this system. This product should be installed by a qualified technician familiar with gas appliances. Always wear gloves and safety glasses when installing this product and follow all installation instructions. Modification of any components will void the warrant y and could create a fire hazard. t Functions Press the MODE button located on the front of the transmitter to select the desired function. • The ON indictor shows the system is turned on in the manual, timer or thermostat settings. • The OFF icon indicates the system is turned off. • The THERMO icon indicates the system is programmed to automatically cycle ON or OFF according to the temperature programmed. Setting the Time Function: Open front door of the transmitter and locate the TIME/TIMER button. Press and hold the TIME/TIMER button until the time flashes. Use the UP or DOWN buttons to change the time to the desired setting. NOTE: If no change UP or DOWN is made to the flashing TIME icon within 10-15 seconds, the system will reset to the last setting. Close the front cover when finished with the settin g. 2 3 Button Functions and Settings Depress the TIME/TIMER button for three seconds and the TIME icon flashes. • Set hour by pressing the UP or DOWN button to set the hour in AM or PM. • With hour set to desired setting, press the TIME-TIMER button a second time until the minute icon flashes. • Set minutes by pressing the UP or DOWN button to set the minutes. • Press SET button , the time icons will stop flashing to indicate the time has been correctly programmed. Fahrenheit / Celsius settings. The transmitter is set at the factory to Fahrenheit. Press and hold both UP & DOWN buttons at the same time to change to Celsius setting. Repeat this procedure to change back to Fahrenheit. When making these changes, the SET icon will return to the lowest temperature setting ( 45 F or 6 C ). NOTE: Maximum Fahrenheit setting is 99 degrees and the maximum setting for Celsius is 32. Set Room Temperature: To set temperature function, the transmitter must be in the THERMO mode with the THERMO icon displayed on the screen. The system will function thermostatically when set in this mode. To set this function, press the MODE button until the THERMO icon appears. Press the UP or DOWN buttons until the temperature setting appears in the thermo set box. When the THERMO feature is programmed, the transmitter operates the appliance and cycles the appliance when the room temperature varies more than two degrees. The unit will typically cycle 2-5 times per hour. The syste m in factory is set to thermostatically, change the temperature setting when the room temperature varies more than two degrees F or one degree C. NOTE: When using the transmitter in the THERMO mode, care should be taken to keep the transmitter away from direct heat sources such as direct sunlight, heat ducts or fireplaces that could affect the temperature diode in the transmitter. An incorrect temperature reading could result from exposure to these other heat sources. Setting the Timer: To use the countdown timer function, the transmitter must be in the ON or THERMO setting. When first using this function, set the timer for 15 minutes. The timer should count down to zero and the appliance should return to the OFF setting. The minutes are shown next to the TIMER icon. To restart the system,…

Text truncated - open the document above for the full version.

Cover Letter(s)

FCC POA.TIF (1664 x 2312 x 1)

Cover Letter(s)

FCC Confidentiality.TIF (1664 x 2312 x 1)

External Photos

Page 1 CONSTRUCTION PHOTOS OF EUT Page 2

ID Label/Location Info

PDF created with pdfFactory trial version www.pdffactory.com

Internal Photos

Page 3 Page 4 Page 5

Operational Description

FCC ID: RRX-AHP304R12T Report No: RF930423L01 Operational Description The transmitter of the EUT (BUILT-IN ELECTRIC FIREPLACE THERMO REMOTE CONTROLLER) is powered by a 3Vdc batteries. The transmitter uses printed antenna and designed to operate on a fixed frequency at 433.92MHz. There is one button trigger the encoder IC (IC101) which produces the digital control signals and will modulate the carrier signal. The carrier signal is generated by a SAW oscillator / Amplifier circuit then coupled to the printed antenna. This 433.92MHz transmitter device is operated by manual and activate time is less than 5 second after being released.

Test Report

FCC ID: RRX-AHP304R2T Report No.: RF930423L011Issued: May 4, 2004 FCC TEST REPORT REPORT NO.: RF930423L01 MODEL NO.: AHP304R2T RECEIVED: Apr. 23, 2004 TESTED: Apr. 28 ~ Apr. 29, 2004 APPLICANT: AVANTI HEARTH PRODUCTS ADDRESS: 204 South Avon Street Suite 200, Gastonia, NC 28054, U.S.A ISSUED BY: Advance Data Technology Corporation LAB LOCATION: No. 19, Hwa Ya 2 nd Rd., Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C. This test report consists of 21 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product endorsement by any government agencies. The test results in the report only apply to the tested sample. FCC ID: RRX-AHP304R2T Report No.: RF930423L012Issued: May 4, 2004 Table of Contents 1CERTIFICATION ..................................................................................... 3 2SUMMARY OF TEST RESULTS ............................................................. 4 3.GENERAL INFORMATION...................................................................... 5 3.1GENERAL DESCRIPTION OF EUT ........................................................ 5 3.2DESCRIPTION OF TEST MODES .......................................................... 6 3.3GENERAL DESCRIPTION OF APPLIED STANDARDS ......................... 6 3.4DESCRIPTION OF SUPPORT UNITS .................................................... 7 3.5CONFIGURATION OF SYSTEM UNDER TEST..................................... 7 4.TEST TYPES AND RESULTS ................................................................. 8 4.1CONDUCTED EMISSION MEASUREMENT .......................................... 8 4.2RADIATED EMISSION MEASUREMENT ............................................... 8 4.2.1LIMITS OF RADIATED EMISSION MEASUREMENT ............................. 8 4.2.2TEST INSTRUMENTS........................................................................... 10 4.2.3TEST PROCEDURES ........................................................................... 11 4.2.4DEVIATION FROM TEST STANDARD ................................................. 11 4.2.5TEST SETUP ........................................................................................ 12 4.2.6EUT OPERATING CONDITIONS .......................................................... 12 4.2.7TEST RESULTS .................................................................................... 13 4.320dB OCCUPIED BANDWIDTH MEASUREMENT............................... 17 4.3.1LIMITS OF BAND EDGES MEASUREMENT........................................ 17 4.3.2TEST INSTRUMENTS........................................................................... 17 4.3.3TEST PROCEDURES ........................................................................... 17 4.3.4DEVIATION FROM TEST STANDARD ................................................. 18 4.3.5TEST SETUP ........................................................................................ 18 4.3.6TEST RESULTS .................................................................................... 18 5.PHOTOGRAPHS OF THE TEST CONFIGURATION ............................ 20 6.INFORMATION ON THE TESTING LABORATORIES .......................... 21 FCC ID: RRX-AHP304R2T Report No.: RF930423L013Issued: May 4, 2004 1 CERTIFICATION PRODUCT : BUILT-IN ELECTRIC FIREPLACE THERMO REMOTE CONTROLLER MODEL NO.: AHP304R2T BRAND: AVANTI APPLICANT : AVANTI HEARTH PRODUCTS TESTED: Apr. 28 ~ Apr. 29, 2004 TEST ITEM: ENGINEERING SAMPLE STANDARDS : FCC Part 15, Subpart C (Section 15.231), ANSI C63.4-2001 The above equipment has been tested by Advance Data Technology Corporation, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC characteristics under the conditions specified in this report. PREPARED BY:, DATE:May 4, 2004 APPROVED BY: Windy Chou , DATE:May 4, 2004 Cody Chang / Supervisor FCC ID: RRX-AHP304R2T Report No.: RF930423L014Issued: May 4, 2004 2 SUMMARY OF TEST RESULTS The EUT has been tested according to the following specifications: APPLIED STANDARD: FCC Part 15, Subpart C STANDARD PARAGRAPH TEST TYPERESULTREMARK 15.207Conducted Emission TestNA3Vdc from batteries 15.209 15.231 Radiated Emission TestPASS Minimum passing margin is –0.79dB at 433.88MHz 15.231 20dB Occupied Bandwidth Measurement PASS Meet the requirement of limit NOTE: The information of measurement uncertainty is available upon the customer’s request. FCC ID: RRX-AHP304R2T Report No.: RF930423L015Issued: May 4, 2004 3. GENERAL INFORMATION 3.1 GENERAL DESCRIPTION OF EUT PRODUCT BUILT-IN ELECTRIC FIREPLACE THERMO REMOTE CONTROLLER MODEL NO. AHP304R2T BRAND AVANTI POWER SUPPLY 3Vdc from batteries MODULATION TYPE ASK CARRIER FREQUENCY OF EACH CHANNEL 433.92MHz NUMBER OF CHANNEL 1 ANTENNA TYPE Printed antenna DATA CABLE NA I/O PORTS NA NOTE: 1. The EUT is only Transmitter part. 2. The above EUT information was declared by manufacturer and for more detailed features description, please refer to the manufacturer's specifications or User's Manual. FCC ID: RRX-AHP304R2T Report No.: RF930423L016Issued: May 4, 2004 3.2 DESCRIPTION OF TEST MODES One channel is provided to this EUT: ChannelFrequency 1433.92 MHz 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS The EUT is a BUILT-IN ELECTRIC FIREPLACE THERMO REMOTE CONTROLLER. According to the specifications of the manufacturer, it must comply with the requirements of the following standards: FCC Part 15, Subpart C. (15.231) ANSI C63.4: 2001 All test items have been performed and recorded as per the above standards. NOTE: The EUT is also considered as a kind of computer peripheral, because the connection to computer is necessary for typical use. It has been verified to comply with the requirements of FCC Part 1…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: RRX-AHP304R2T Report No.: RF930423L0120Issued: May 4, 2004 5. PHOTOGRAPHS OF THE TEST CONFIGURATION RADIATED EMISSION TEST (For Z axis)

Contact Information

Applicant

Loren Packard(President)
[email protected]704-825-9225Fax: 704-829-5015

Technical Contact

Advance Data Technology Corp.Ellis Wu
[email protected]+886-3-318-3232

No.19, Hwa Ya 2nd Rd. · Kueishan Taoyuan · Taiwan

Test Firm

Advance Data Technology CorporationStephen Chen
[email protected]8862602180Fax: 8862602943

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term