FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. HAMILTON & PALMER INSTALLATIONS LTD/
  3. RW4-TAG1

RW4-TAG13D System TAG1

HAMILTON & PALMER INSTALLATIONS LTD
3D System TAG1 - FCC ID RW4-TAG1 - HAMILTON & PALMER INSTALLATIONS LTD
Click to zoom

Application Details

Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Date of Grant
May 28, 2015
Application Purpose
Original Equipment
Date of Application
May 28, 2015
Equipment Note
3D System TAG1
Frequency Range
433.00000000 - 433.00000000
Company
HAMILTON & PALMER INSTALLATIONS LTD
Country
United Kingdom

Documents & Files

Select a file to view

Users Manual

β†—
β†—

Attestation Statements

Cover Letter(s)

β†—

External Photos

β†—

ID Label/Location Info

β†—

Internal Photos

β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

TRL 51F050 iss04 REQUEST FOR CONFIDENTIALITY IN ACCORDANCE WITH FCC RULE 0.459 30 th November 2013 TRaC GLOBAL LTD. 100 Frobisher Business Park Malvern Worcestershire WR14 1BX UK RE: Certification Application FCC ID: RW4-TAG1 To Whom It May Concern: Please be advised that the following information is to be held confidential on behalf of Hamilton & Palmer Installations Limited ο‚· Schematics and block diagrams ο‚· Operational description The application contains technical information which Hamilton & Palmer Installations Limited deems to be trade secrets and propriety. If made public, the information might be used to the disadvantage of the applicant in the market place. Thank you for your attention to this matter. Yours faithfully Hamilton & Palmer Installations Ltd Kevin Palmer Hamilton & Palmer Hamilton & Palmer Installations Limited F1 Chaucer Business Park, Watery Lane, Kemsing, Kent TN15 6PL Tel +441732 760022 Fax +441732 760033 Email [email protected] Company Registration Number 3507969 BOM

Test Report

A RADIO TEST REPORT FOR HAMILTON & PALMER INSTALLATIONS Ltd ON 3D TAG DRIVER ID CHALLENGE AND RESPONSE SYSTEM DOCUMENT NO. TRA-009740-W-NA-2 Total number of pages: 31 TRaC Wireless Test Report : TRA-009740-W-NA-2 Applicant : Hamilton & Palmer Installations Ltd Apparatus : 3D TAG Specification(s) : CFR47 Part 15 & RSS-210 Purpose of Test : Certification FCCID : RW4-TAG1 Certification Number : 10877A-TAG1 Authorised by : : Radio Product Manager Issue Date :11 th December 2013 Authorised Copy Number : PDF TRaC Global Test Report: TRA-009740-W-NA-2 3 Contents Section 1: Introduction 4 1.1 General 4 1.2 Tests Requested By 5 1.3 Manufacturer 5 1.4 Apparatus Assessed 5 1.5 Test Result Summary 6 1.6 Notes Relating To The Assessment 7 1.7 Deviations from Test Standards 7 Section 2: Measurement Uncertainty 8 2.1 Measurement Uncertainty Values 8 Section 3: Modifications 10 3.1 Modifications Performed During Assessment 10 Appendix A: Formal Emission Test Results 11 A1 Transmitter Intentional Emission Radiated 12 A2 Radiated Electric Field Emissions 14 Appendix B: Supporting Graphical Data 16 Appendix C: Additional Test and Sample Details 20 Appendix D: Additional Information 26 Appendix E: Calculation of the duty cycle correction factor 27 Appendix F: Photographs and Figures 28 TRaC Global Test Report: TRA-009740-W-NA-2 4 Section 1: Introduction 1.1 General This report contains an assessment of an apparatus against Electromagnetic Compatibility Standards based upon tests carried out on samples submitted to the Laboratory. Test performed by: TRaC Global [ ] Unit E South Orbital Trading Park Hedon Road Hull, HU9 1NJ. United Kingdom. Telephone: +44 (0) 1482 801801 Fax: +44 (0) 1482 801806 TRaC Global [X] Unit 1 Pendle Place Skelmersdale West Lancashire, WN8 9PN United Kingdom Telephone: +44 (0) 1695 556666 Fax: +44 (0) 1695 577077 Email: [email protected] Web site: http://www.tracglobal.com Tests performed by: D. Winstanley Report author: D. Winstanley This report must not be reproduced except in full without prior written permission from TRaC Global. TRaC Global Test Report: TRA-009740-W-NA-2 5 1.2 Tests Requested By This testing in this report was requested by : Hamilton & Palmer Installations Ltd F1 Chaucer Business Park Watery Lane Kemsing Sevenoaks Kent TN15 6PL 1.3 Manufacturer As Above 1.4 Apparatus Assessed The following apparatus was assessed between 13 th – 19 th December 2012 3D TAG Driver ID Challenge and Response System The 3D TAG is 433 MHZ transmitter that is activated by a 125 kHz transmitter, FCCID covered under test report TRA-009740-W-US-1 TRaC Global Test Report: TRA-009740-W-NA-2 6 1.5 Test Result Summary Full details of test results are contained within Appendix A. The following table summarises the results of the assessment. The statements relating to compliance with the standards below apply ONLY as qualified in the notes and deviations stated in sections 1.6 to 1.7 of this test report. Full details of test results are contained within Appendix A. The following table summarises the results of the assessment. Test Type Regulation Measurement standard Result RSS-210 Issue 8 December 2010 Title 47 of the CFR: Part 15 Subpart (c) Spurious Emissions Radiated <1000MHz A1.1.2 RSS-Gen 7.2.5 15.231(b) & 15.209 ANSI C63.10:2009 Pass Spurious Emissions Radiated >1000MHz A1.1.2 RSS-Gen 7.2.5 15.231(b) & 15.209 ANSI C63.10:2009 Pass AC Power conducted emissions RSS-GEN Issue 3 Annex 7, 7.2.4 15.207 ANSI C63.10:2009 N/A Tr ansmission times A.1.1.1 15.231(a) ANSI C63.10:2009 Pass Intentional Emission Frequency A1.1.2 RSS-Gen 7.2.5 15.231(b) ANSI C63.10:2009 Pass Intentional Emission Field Strength A1.1.2 RSS-Gen 7.2.5 15.231(b) ANSI C63.10:2009 Pass Intentional Emission Band Occupancy A1.1.3 RSS-Gen 4.6.1 15.215 ANSI C63.10:2009 Pass Intentional Emission ERP (mW) N/A N/A ANSI C63.10:2009 N/A Unintentional Radiated Spurious Emissions RSS-GEN Issue 3 7.2.2(c) 15.109 ANSI C63.10:2009 N/A Antenna Arrangements Integral: RSS-Gen 7.1.2 15.203 - Pass Antenna Arrangements External Connector RSS-Gen 7.1.2 15.204 - N/A Restricted Bands RSS-Gen 7.2.2 15.205 - Pass Maximum Frequency of Search RSS-Gen 4.3 15.33 - Pass Extrapolation Factor RSS-Gen 7.2.7 15.31(f) - Pass Abbreviations used in the above table: ANSI C 63.10:2009 is outside the scope of the laboratories UKAS accreditation. CFR : Code of Federal Regulations ANSI : American National Standards Institution REFE : Radiated Electric Field Emissions PLCE : Power Line Conducted Emissions TRaC Global Test Report: TRA-009740-W-NA-2 7 1.6 Notes Relating To The Assessment With regard to this assessment, the following points should be noted: The results contained in this report relate only to the items tested and were obtained in the period between the date of initial receipt of samples and the date of issue of the report. The apparatus was set up and exercised using the configurations, modes of operation and arrangements defined in this report only. Particular operating modes, apparatus monitoring methods and performance criteria required by the standards tested to have been performed except where identified in Section 1.7 of this test report (Deviations from Test Standards). For emissions testing, throughout this test report, β€œPass” indicates that the results for the sample as tested were below the specified limit (refer also to Section 2, Measurement Uncertainty). Where relevant, the apparatus was only assessed using the monitoring methods and susceptibility criteria defined in this report. All testing with the exception of testing at the Open Area Test Site was performed under the following environmental conditions: Temperature : 17 to 23 Β°C Humidity : 45 to 75 % Barometric Pressure : 86 to 106 kPa All dates used in this report are in the format dd/mm/yy. This assessment has been performed in accordance with the requirements of ISO/IEC 17025. 1.7 Deviations from Test Standards There were no deviations from the standards tested to. TRaC Global Test Repor…

Text truncated - open the document above for the full version.

Contact Information

Applicant

KEVIN JOHN PALMER(MR)
[email protected]01732760022Fax: 01732760033

Test Firm

Element Materials Technology Warwick LtdStewart Barrowclough
[email protected]01695556666Fax: 01695557077

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433 MHz - 433 MHz-
Confidentiality
Long Term

Other Applications from HAMILTON & PALMER INSTALLATIONS LTD

3D ADR2DID2 Tag Reader - FCC ID RW4-ADR2DID2 - HAMILTON & PALMER INSTALLATIONS LTD
RW4-ADR2DID2

3D ADR2DID2 Tag Reader

May 28, 2015

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz