FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Wonu Telecom Co., Ltd/
  3. RWDWGM-1893C

RWDWGM-1893CGSM/PCS 900/1800/1900 MHz Mobile Phone

Wonu Telecom Co., Ltd
GSM/PCS 900/1800/1900 MHz Mobile Phone - FCC ID RWDWGM-1893C - Wonu Telecom Co., Ltd
Click to zoom

Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
Apr 18, 2004
Application Purpose
Original Equipment
Date of Application
Apr 18, 2004
Equipment Note
GSM/PCS 900/1800/1900 MHz Mobile Phone
Frequency Range
1850.20000000 - 1909.80000000
Company
Wonu Telecom Co., Ltd
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

External Photos

CETECOM ICT Services GmbH Test report No..: 4-1272-01-05/04Date: 2004.03.25Page 57 (69) Photographs of Equipment Photo No.: 05 CETECOM ICT Services GmbH Test report No..: 4-1272-01-05/04Date: 2004.03.25Page 58 (69) Photographs of Equipment Photo No.: 06 CETECOM ICT Services GmbH Test report No..: 4-1272-01-05/04Date: 2004.03.25Page 59 (69) Photographs of Equipment Photo No.: 07

Internal Photos

CETECOM ICT Services GmbH Test report No..: 4-1272-01-05/04Date: 2004.03.25Page 61 (69) Photographs of Equipment Photo No.: 09 CETECOM ICT Services GmbH Test report No..: 4-1272-01-05/04Date: 2004.03.25Page 62 (69) Photographs of Equipment Photo No.: 10 CETECOM ICT Services GmbH Test report No..: 4-1272-01-05/04Date: 2004.03.25Page 63 (69) Photographs of Equipment Photo No.: 11 CETECOM ICT Services GmbH Test report No..: 4-1272-01-05/04Date: 2004.03.25Page 64 (69) Photographs of Equipment Photo No.: 12 CETECOM ICT Services GmbH Test report No..: 4-1272-01-05/04Date: 2004.03.25Page 65 (69) Photographs of Equipment Photo No.: 13 CETECOM ICT Services GmbH Test report No..: 4-1272-01-05/04Date: 2004.03.25Page 66 (69) Photographs of Equipment Photo No.: 14 CETECOM ICT Services GmbH Test report No..: 4-1272-01-05/04Date: 2004.03.25Page 67 (69) Photographs of Equipment Photo No.: 15

RF Exposure Info

CETECOM ICT Services GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken, Germany Phone: +49 (0) 681 598-0 Fax: -8475 SAR-Laboratory Phone: +49 (0) 681 598-8454 . As of April 7, 2004 Page 1 of 32 Accredited testing laboratory DAR registration number: TTI-P-G 166/98 Federal Motor Transport Authority (KBA) DAR registration number: KBA-P 00070-97 Appendix to the Report 4-1272-01-03/04-B Calibration Data, Phantom Certificate and detail Information of the DASY4 System Test specification : CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1272-01-03/04-B As of April 7, 2004 Page 2 of 32 Table of Content 1 Calibration report “Probe ET3DV6” ..................................................................................................................................... 3 2 Calibration report “1900 MHz System validation dipole”.................................................................................................. 14 3 Calibration certificate of Data Aquisition Unit (DAE) ........................................................................................................ 24 4 Certificate of Conformity “SAM Twin Phantom V4.0/V4.0C”........................................................................................... 25 5 Application Note System Performance Check..................................................................................................................... 27 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1272-01-03/04-B As of April 7, 2004 Page 3 of 32 1 Calibration report “Probe ET3DV6” CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1272-01-03/04-B As of April 7, 2004 Page 4 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1272-01-03/04-B As of April 7, 2004 Page 5 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1272-01-03/04-B As of April 7, 2004 Page 6 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1272-01-03/04-B As of April 7, 2004 Page 7 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1272-01-03/04-B As of April 7, 2004 Page 8 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1272-01-03/04-B As of April 7, 2004 Page 9 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1272-01-03/04-B As of April 7, 2004 Page 10 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1272-01-03/04-B As of April 7, 2004 Page 11 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1272-01-03/04-B As of April 7, 2004 Page 12 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1272-01-03/04-B As of April 7, 2004 Page 13 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1272-01-03/04-B As of April 7, 2004 Page 14 of 32 2 Calibration report “1900 MHz System validation dipole” CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1272-01-03/04-B As of April 7, 2004 Page 15 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1272-01-03/04-B As of April 7, 2004 Page 16 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1272-01-03/04-B As of April 7, 2004 Page 17 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1272-01-03/04-B As of April 7, 2004 Page 18 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1272-01-03/04-B As of April 7, 2004 Page 19 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1272-01-03/04-B As of April 7, 2004 Page 20 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1272-01-03/04-B As of April 7, 2004 Page 21 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1272-01-03/04-B As of April 7, 2004 Page 22 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1272-01-03/04-B As of April 7, 2004 Page 23 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1272-01-03/04-B As of April 7, 2004 Page 24 of 32 3 Calibration certificate of Data Aquisition Unit (DAE) CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1272-01-03/04-B As of April 7, 2004 Page 25 of 32 4 Certificate of Conformity “SAM Twin Phantom V4.0/V4.0C” CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1272-01-03/04-B As of April 7, 2004 Page 26 of 32 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-1272-01-03/04-B As of April 7, 2004 Page 27 of 32 5 Application Note System Performance Check 5.1.1.1 Purpose of system performance check The system performance check verifies that the system operates within its specifica-tions. System and operator errors can be detected and corrected. It is recommended that the system performance check is performed prior to any usage of the system in order to guarantee reproducible results. The measurement of the Specific Absorption Rate (SAR) is a complicated task and the result depends on the proper functioning of many components and the correct settings of many param-eters. Faulty results due to drift, failures or incorrect parameters might not be recognized, since they often look similar in distribution to the correct ones. The Dosimetric Assessment System DASY4 incorporates a system performance check procedure to test the proper functioning of the system. The system performance check uses normal SAR measurements in a simplified setup (the at section of the SAM Twin Phantom) with a well characterized source (a matched dipole at a specified distance…

Text truncated - open the document above for the full version.

RF Exposure Info

CETECOM ICT Services GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken, Germany Phone: +49 (0) 681 598-0 Fax: -8475 SAR-Laboratory Phone: +49 (0) 681 598-8454 . As of April 6, 2004 Page 1 of 81 Accredited testing laboratory DAR registration number: TTI-P-G 081/94-D0 Federal Motor Transport Authority (KBA) DAR registration number: KBA-P 00070-97 Test report no. : 4-1272-01-03/04 Type identification : WonU WGM-1893C Test specification : IEEE P1528/D1.2 FCC-ID : RWDWGM-1893C Test specification : CETECOM ICT Services GmbH Test report no.: 4-1272-01-03/04 As of April 6, 2004 Page 2 of 81 Table of Contents 1 General Information............................................................................................................................................................... 3 1.1 Notes .............................................................................................................................................................................. 3 1.1.1 Statement of Compliance ....................................................................................................................................... 3 1.2 Testing laboratory .......................................................................................................................................................... 4 1.3 Details of applicant ........................................................................................................................................................ 4 1.4 Application details ......................................................................................................................................................... 4 1.5 Test item ........................................................................................................................................................................ 5 1.6 Test specification(s) ....................................................................................................................................................... 6 1.6.1 RF exposure limits ................................................................................................................................................. 6 2 Technical test ......................................................................................................................................................................... 7 2.1 Summary of test results.................................................................................................................................................. 7 2.2 Test environment ........................................................................................................................................................... 7 2.3 Measurement and test set-up.......................................................................................................................................... 7 2.4 Measurement system...................................................................................................................................................... 8 2.4.1 System Description ................................................................................................................................................ 8 2.4.2 Test environment ................................................................................................................................................... 9 2.4.3 Probe description ................................................................................................................................................... 9 2.4.4 Phantom description ............................................................................................................................................ 10 2.4.5 Device holder description .................................................................................................................................... 10 2.4.6 Scanning procedure.............................................................................................................................................. 11 2.4.7 Spatial Peak SAR Evaluation............................................................................................................................... 12 2.4.8 Data Storage and Evaluation................................................................................................................................ 13 2.4.9 Test equipment utilized........................................................................................................................................ 15 2.4.10 Tissue simulating liquids : dielectric properties................................................................................................... 16 2.4.11 Tissue simulating liquids : parameters................................................................................................................. 17 2.4.12 Measurement uncertainty evaluation for SAR test .............................................................................................. 18 2.4.13 Measurement uncertainty evaluation for system validation................................................................................. 19 2.4.14 System validation................................................................................................................................................. 20 2.4.15 Validation procedure............................................................................................................................................ 21 2.5 Test results (Head and Body SAR) .............................................................................................................................. 22 2.5.1 EUT closed .......................................................................................................................................................... 22 2.5.2 EUT opened .................................…

Text truncated - open the document above for the full version.

Test Report

CETECOM ICT Services GmbH Radio Satellite Communication Untertürkheimer Straße 6-10 . D-66117 Saarbrücken Telefon: +49 (0)681 598-0 Telefax: - 9075 Test report No.: 4-1272-01-05/04 This test report consists of 69 pagesPage 1 (69) BLUETOOTH TM is a trademark owned by Bluetooth SIG, Inc. and licensed to CETECOM Recognized by the Federal Communications Commission Anechoic chamber registration no.: 90462 (FCC) Anechoic chamber registration no.: 3463 (IC) TCB ID: DE 0001 Accredited by the German Accreditation Council DAR–Registration Number TTI–P–G 081/94-D0 Independent ETSI compliance test house ETSI Accredited Bluetooth™ Test Facility (BQTF) Test report no.: 4-1272-01-05/04 Applicant:WONU TypeWGM-1893C FCC Part 24 / 15 FCC ID:RWDWGM-1893C CETECOM ICT Services GmbH Test report No..: 4-1272-01-05/04Date: 2004.03.25Page 2 (69) Table of Contents 1 General information 1.1 Notes 1.2 Testing laboratory 1.3 Details of applicant 1.4 Application details 1.5 Test item 1.6 Test standards 2 Technical test 2.1 Summary of test results 2.2 Test report CETECOM ICT Services GmbH Test report No..: 4-1272-01-05/04Date: 2004.03.25Page 3 (69) 1 General information 1.1 Notes The test results of this test report relate exclusively to the test item specified in 1.5. The CETECOM ICT Services GmbH does not assume responsibility for any conclusions and generalizations drawn from the test results with regard to other specimens or samples of the type of the equipment represented by the test item. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of the CETECOM ICT Services GmbH. 1.2Testing laboratory CETECOM ICT Services GmbH Untertürkheimer Straße 6 - 10 66117 Saarbrücken Germany Telephone: + 49 681 598 - 9100 Telefax : + 49 681 598 - 9075 E-mail: [email protected] Internet: www.cetecom-ict.de Accredited testing laboratory The test laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025. DAR registration number: TTI-P-G-081/94-D0 Listed by: Federal Communications Commission (FCC) Identification/Registration No : 90462 Accredited Bluetooth TM Test Facility (BQTF) BLUETOOTH TM is a trademark owned by Bluetooth SIG, Inc. and licensed to CETECOM 1.3Details of applicant Name : WONU Telecom Co. Ltd Street : # 911 SunTechCity Bldg, City : 513-15 SangDae Won-dong3 Country : JungWon-Gu, SeongNam, Geonggi-Do, Korea (462-802) Telephone : + 82 31 777 2323 Telefax : + 82 31 777 2329 Contact : Young Moon, Han Telephone : + 82 31 777 2323 Telefax : + 82 31 777 2329 e-mail: [email protected] 1.4 Application details Date of test : 2004-03-23 to 2004-03-24 CETECOM ICT Services GmbH Test report No..: 4-1272-01-05/04Date: 2004.03.25Page 4 (69) 1.5 Test item Type of equipment :GSM/Triple band mobile phone 900//1800/1900 Type designation:WGM-1893C Manufacturer:applicant Street: City: Country: Serial numbers: Additional information : Frequency :1850.2 – 1909.8 MHz Type of modulation:300KGXW Number of channels :300 (PCS1900) Antenna:Integral antenna Power supply (normal):3.7 V DC Li-Polymer Battery Power supply (extreme):3.4 V to 4.3 V Output power GSM 1900 :cond : 30.1 dBm Peak, ERP:29.45 dBm (Burst); EIRP: 31.6 dBm (Burst) Type of equipment:Temperature range : -30°C - +60°C FCC – ID:RWDWGM-1893C Hardware:MASV2 Software:JE, G01 Test set up Mobile; S/N: G1893C 434S000011 IMEI: 35357500000030-1 Mobile; S/N: G1893C 434S000012IMEI: 35357500000016-0 Travel Adaptor Model: TA 3651-EU 100-240V (AC) 50/60Hz S/N: 031101731 AB Headset 1.6Test standards: FCC Part 24 FCC Part 15 CETECOM ICT Services GmbH Test report No..: 4-1272-01-05/04Date: 2004.03.25Page 5 (69) 2 Technical test For Part 24 we use the substitution method ( TIA/EIA 603). All measurements in this report were performed in GSM circuit - switched mode in band 1900 MHz. The handset does not offer GPRS or multislot service. Remarks: Test setup: The radiated measurements were performed with an AC/DC charging unit No deviations from the technical specification(s) were ascertained in the course of the tests performed. FINAL VERDICT: PASS Technical responsibility for area of testing : 2004-03-25RSC 8431 Gillmann DateSectionNameSignature Technical responsibility for area of testing : 2004-03-25RSC8412Hausknecht D. DateSectionNameSignature CETECOM ICT Services GmbH Test report No..: 4-1272-01-05/04Date: 2004.03.25Page 6 (69) TEST REPORT REFERENCE LIST OF MEASUREMENTS PARAMETER TO BE MEASURED PAGE PART PCS 1900 POWER OUTPUT SUBCLAUSE § 24.2327 FREQUENCY STABILITY SUBCLAUSE § 24.23510 AFC FREQ ERROR VS. VOLTAGE11 AFC FREQ ERROR VS. TEMPERATURE11 EMISSIONS LIMITS SUBCLAUSE §24.23813 RECEIVER SPURIOUS RADIATION SUBCLAUSE § 15.10924 CONDUCTED SPURIOUS EMISSIONS30 BLOCK EDGE COMPLIANCE FOR BLOCK A AND C39 OCCUPIED BANDWIDTH SUBCLAUSE §2.98941 ADDITIONAL MEASUREMENT WITH ACCORIESES ACC. SUCLAUSE § 15.105.20548 TEST EQUIPMENT AND ANCILLARIES USED FOR TESTS51 PHOTOS OF TEST SITE AND PHOTOS OF EQUIPMENT 53 CETECOM ICT Services GmbH Test report No..: 4-1272-01-05/04Date: 2004.03.25Page 7 (69) REFERENCE NUMBER(S) OF TEST EQUIPMENT USED (for reference numbers see test equipment listing) 64 PART PCS 1900 POWER OUTPUT SUBCLAUSE § 24.232 Summary: This paragraph contains both average , peak output powers and EIRP measurements for the mobile station. In all cases, the peak output power is within the required mask (this mask is specified in the JTC standards, TIA PN3389 Vol. 1 Chap 7, and is no FCC requirement). Method of Measurements: The mobile was set up for the max. output power with pseudo random data modulation. The power was measured with R&S Signal Analyzer FSIQ 26 ( peak and average) This measurements were done at 3 frequencies, 1850.2 MHz, 1880.0 MHz and 1909.8 MHz (bottom, middle and top of operational frequency range) Limits: Power StepNominal Peak Output Power (dBm) Tolerance (dB) 0+30 ± 2 Power Measurements: Conducted: Frequency (MHz) Power Step Peak Output Power (dBm) Average …

Text truncated - open the document above for the full version.

Test Setup Photos

CETECOM ICT Services GmbH Test report No..: 4-1272-01-05/04Date: 2004.03.25Page 53 (69) Test site Photo No.: 01 CETECOM ICT Services GmbH Test report No..: 4-1272-01-05/04Date: 2004.03.25Page 54 (69) Test site Photo No.: 02 CETECOM ICT Services GmbH Test report No..: 4-1272-01-05/04Date: 2004.03.25Page 55 (69) Test site Photo No.: 03 CETECOM ICT Services GmbH Test report No..: 4-1272-01-05/04Date: 2004.03.25Page 56 (69) Test site Photo No.: 04

Contact Information

Applicant

Vincent YS Cho
[email protected]82-31-777-2323Fax: 82-31-777-2329

Test Firm

Cetecom ICT Services GmbHRalf Hoehn
[email protected]49-681-598-8455Fax: 49-681-598-8475

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
124E1.85 GHz - 1.91 GHz1.445 W300KGXW0.0144000000 ppm
Confidentiality
Long Term
Grant Notes
Power listed is EIRP. This filing is only applicable for GSM 1900 operations. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic and a minimum distance of 15 mm to the body. End-users must be provided with the appropriate information for satisfying RF exposure compliance. Highest reported SAR values are: Head: 1.25 W/kg, Body: 0.992 W/kg. This mobile contains 900 MHz and 1800 MHz function that is not operational in U.S. Territories.

Other Applications from Wonu Telecom Co., Ltd

GSM/GPRS 1900 MHz Phone - FCC ID RWDWGM-1898A - Wonu Telecom Co., Ltd
RWDWGM-1898A

GSM/GPRS 1900 MHz Phone

Aug 23, 2004

Equipment Class

PCE - PCS Licensed Transmitter held to ear
GSM/GPRS 1900 MHz Phone - FCC ID RWDWGM1898A - Wonu Telecom Co., Ltd
RWDWGM1898A

GSM/GPRS 1900 MHz Phone

Aug 17, 2004

Equipment Class

PCE - PCS Licensed Transmitter held to ear