RWK-889767Remote Control

Overseas Win Limited.
Remote Control - FCC ID RWK-889767 - Overseas Win Limited.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Mar 21, 2004
Application Purpose
Original Equipment
Date of Application
Mar 21, 2004
Equipment Note
Remote Control
Frequency Range
433.40000000 - 433.40000000
Company
Overseas Win Limited.
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Operational Description

↗

Schematics

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Block Diagram

DATE:26 FEB, 04 REMOTE LANTERN EMITTING PART OPERATION BLOCK DIAGRAM POWER SWITCH IC CODE PARTMODULATION &HF EMITTING PART PARTHF OSCILLATION PART

External Photos

PHOTOGRAPH OF THE PRODUCT FRONT VIEW OF THE PRODUCT REAR VIEW OF THE PRODUCT

Internal Photos

PHOTOGRAPH OF THE PRODUCT INNER CIRCUIT TOP VIEW INNER CIRCUIT BOTTOM VIEW

Operational Description

FCC ID: RWK-889767 Circuit Description The 433MHz crystal oscillator drives the base of Q1 the final/buffer amplifier. The modulation provided by IC. The output of Q1 has the matching network consisting of L1 and C2 that limit the harmonic content and effect the proper coupling of the antenna to the output stage. Antenna, Ground and Power Source There is no external antenna. There is no external ground connection. The ground is only that of the printed circuit board. Electric current is supplied by a 12 Volt (“A23” size battery x 1) primary battery.

Test Report

Date: 2004-03-06 TEST REPORT Page 1 of 21 No.: HM112733 FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER TEST REPORT No.: HM112733 Equipment Under Test [EUT]: Double Tube 5-in-1 Lantern With Remote Control Model Number: 0-889767-117 Applicant: Overseas Win Limited. FCC ID: RWK-889767 Date: 2004-03-06 TEST REPORT Page 2 of 21 No.: HM112733 CONTENT: Cover Page 1 of 21 Content Page 2-3 of 21 Conclusion Page 4 of 21 1.0 General Details 1.1 Test Laboratory Page 5 of 21 1.2 Applicant Details Page 5 of 21 Applicant HKSTC Code Number for Applicant Manufacturer 1.3 Equipment Under Test [EUT] Page 6 of 21 Description of EUT operation 1.4 Date of Order Page 6 of 21 1.5 Submitted Sample Page 6 of 21 1.6 Test Duration Page 6 of 21 1.7 Country of Origin Page 6 of 21 1.8 Additional Information of EUT Page 7 of 21 2.0 Technical Details 2.1 Investigations Requested Page 8 of 21 2.2 Test Standards and Results Summary Page 8 of 21 3.0 Test Results 3.1 Emission Page 9-13 of 21 3.2 Bandwidth Measurement Page 14-15 of 21 Date: 2004-03-06 TEST REPORT Page 3 of 21 No.: HM112733 Appendix A List of Measurement Equipment Page 16 of 21 Appendix B Duty Cycle Correction During 100 msec Page 17-18 of 21 Appendix C Periodic Operation Page 19 of 21 Appendix D Photographs Page 20-21 of 21 Date: 2004-03-06 TEST REPORT Page 4 of 21 No.: HM112733 CONCLUSION The submitted product was deemed to have COMPLIED with the requirements of Federal Communications Commission [FCC] Rules and Regulations Part 15. The tests were performed in accordance with the standards described above and on Section 2.2 in this Test Report. Verified by Ivan Toa K C Lee for Chief Executive Date: 2004-03-06 TEST REPORT Page 5 of 21 No.: HM112733 1.0 General Details 1.1 Test Laboratory The Hong Kong Standards and Testing Centre Ltd. EMC Laboratory 10 Dai Wang Street, Taipo Industrial Estate New Territories, Hong Kong Telephone: 852 2666 1888 Fax: 852 2664 4353 1.2 Applicant Details Applicant Overseas Win Limited. Room 1912, 19/F., Hong Kong Plaza, 188 Connaught Road West, Hong Kong. HKSTC Code Number for Applicant OVW001 Manufacturer Teng Long Outdoor Implement Co., Ltd. Xia Lu Jia Village, Yinjiang Town, Yinjiang District, Ningbo City, Zhejiang, China Date: 2004-03-06 TEST REPORT Page 6 of 21 No.: HM112733 1.3 Equipment Under Test [EUT] Description of Sample Product: Double Tube 5-in-1 Lantern With Remote Control Manufacturer: Teng Long Outdoor Implement Co., Ltd. Brand Name: Northwest Territory Model Number: 0-889767-117 Input Voltage: 12Vd.c (“A23” size battery x 1) 1.3.1 Description of EUT Operation The Equipment Under Test (EUT) is an Overseas Win Limited, Double Tube 5-in-1 Lantern With Remote Control. The EUT is to transmit RF signal while each button is being pressed, Modulation by Data Code type is pulses modulation. 1.4 Date of Order 2004-02-13 1.5 Submitted Sample(s): 1 Sample per model 1.6 Test Duration 2004-02-25 1.7 Country of Origin China Date: 2004-03-06 TEST REPORT Page 7 of 21 No.: HM112733 1.8 Additional Information of EUT Submitted Not Available User Manual Part List Circuit Diagram Printed Circuit Board [PCB] Layout Block diagram FCC ID Label Date: 2004-03-06 TEST REPORT Page 8 of 21 No.: HM112733 2.0 Technical Details 2.1 Investigations Requested Perform ElectroMagnetic Interference measurement in accordance with FCC 47CFR [Codes of Federal Regulations] Part 15 and ANSI C63.4:2003 for FCC Certification. 2.2 Test Standards and Results Summary Tables EMISSION Results Summary Test Condition Test Requirement Test Method Class / Test Result Severity Pass Failed N/A Field Strength of Fundamental Emissions & Spurious Emissions FCC 47CFR 15.231a ANSI C63.4:2003 N/A Radiated Emissions, 30MHz to 1GHz FCC 47CFR 15.209 ANSI C63.4:2003 Class B Conducted Emissions on AC, 0.15MHz to 30MHz FCC 47CFR 15.207 ANSI C63.4:2003 Class B Note: N/A - Not Applicable Date: 2004-03-06 TEST REPORT Page 9 of 21 No.: HM112733 3.0 Test Results 3.1 Emission 3.1.1 Radiated Emissions (30 – 1000MHz) Test Requirement: FCC 47CFR 15.109 Class A Test Method: ANSI C63.4:2003 Test Date: 2004-02-25 Mode of Operation: On mode Test Method: The sample was placed 0.8m above the ground plane on the OATS *. Measurements in both horizontal and vertical polarities were performed. During the test, each emission was maximized by: having the EUT continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered typical configuration to obtain worst position, manipulating interconnecting cables, rotating turntable, varying antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst-case are shown in Test Results of the following pages. *: OATS [Open Area Test Site] located at HKSTC with a metal ground plane filed with the FCC pursuant to section 2.948 of the FCC rules, with Registration Number: 90657. Test Setup: EUT Pre-Amplifier Distance = 3m Receiver Turn Table Computer Ground Plane Date: 2004-03-06 TEST REPORT Page 10 of 21 No.: HM112733 Limits for Field Strength of Fundamental Emissions [FCC 47CFR 15.231a]: Frequency Range of Fundamental Field Strength of Fundamental Emission [Peak] Field Strength of Fundamental Emission [Average] [MHz] [ μ V/m] [ μ V/m] 40.66-40.70 1,000 100 70-130 500 50 130-174 500 to 1,500 * 50 to 150 * 174-260 1,500 150 260-470 1,500 to 5,000 * 150 to 500 * Above 470 5,000 500 Where F is the frequency in MHz, the formulas for calculating the maximum permitted fundamental field strengths are as follows: for the band 130-174 MHz, μ V/m at 3 meters=56.81818(F)-6136.3636; for the band 260-470 MHz, μ V/m at 3 meters =41.6667(F)-7083.3333. The maximum permissitted unwanted emission level is 20dB below the maximum permitted fundamental level. Results: CorrectionLimit E-Field Factor @3mPolarity dB μ V/m μ V/m 433.4055.320.776.06309.6109,750.1Horizontal Field Strength Measured dB μ V/m μ V/m Field Strength of Fundamental Emissions Peak Value Frequency Level @3m Field Strength…

Text truncated - open the document above for the full version.

Test Setup Photos

TEST SET UP PHOTOGRAPH OF THE PRODUCT MEASUREMENT OF RADIATED EMISSION TEST SET UP

Contact Information

Applicant

Alex Loh(Manager)
[email protected]26283898Fax: 26283300

Test Firm

Hong Kong Standards & Testing Cen.Wilson Wong
[email protected]852-2666-1888Fax: 852-2664-4353

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.4 MHz - 433.4 MHz-