
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Rhein Tech Laboratories, Inc. Client: Cambiatta 360 Herndon Parkway Model: Cambiatta CM1 Suite 1400 Standards: FCC 15.209 Herndon, VA 20170 Report Number: 2005067 http://www.rheintech.com Date: May 3, 2005 18 of 26 APPENDIX G: MANUAL Please refer to the following pages. Parts Diagram 1 Quick Release Handlebar Mount Diagram 2 Speed Sensor and Magnet Installation Diagram 3 Cadence Sensor and Magnet Installation Diagram 4 Properly Installed Magnets and Sensors Diagram 5 User Manual Thank you for your purchase of Cambiatta. You are now ready to begin the quick start installation and set-up procedures. Please follow these simple steps to insure proper installation and set-up of your device and software. Functions and features 1. The Cambiatta hardware device captures and stores speed, cadence, and heart rate data displayed by your current cycle computer and HRM which can then be downloaded to your computer for analysis on Cambiatta software. 2. Cambiatta Basic Software, once downloaded and registered, gives you the ability to archive ride data to maximize your training with the following features: o Logs rides o Compares archived ride data o Highlights areas for improvement o Tracks speed, cadence, distance, heart rate and more than 15 critical training elements for analysis. Parts List - Parts are pictured. (Diagram 1) Cambiatta Unit Quick Ties (not shown) Speed & Cadence SensorsUSB Cradle and Cable Wheel Magnet Handlebar Mount Crank Magnet Batteries Pre-Installed Installation and Set-up Instructions A. Hardware Installation & Mounting: 1. Attach quick-release handlebar mount to handlebar positioned with double ridge away from rider. Use black rubber band to adjust fit as shown in Diagram 2. 2. Attach Speed Sensor to left chain stay with quick ties as shown in Diagram 3. 3. Attach Wheel Magnet to spoke on rear wheel. Adjust Wheel Magnet and Speed Sensor such that they are aligned as shown in Diagram 3. Note: Must be within 3-5 mm. Once aligned, tighten both to prevent movement.4. Attach Cadence Sensor to left chain stay with quick ties positioned to align with Crank Magnet as shown in Diagram 4 4. Attach Crank Magnet to inside of crank such that it aligns with Cadence Sensor as shown in Diagram 4. Note: Must be within 3-5 mm. Once aligned, tighten both to prevent movement. 5. Test function by mounting Cambiatta on quick release handlebar mount, rotating crank and rear wheel. Press button. If functioning properly indicator lights at top of unit will light. You must be using your HR strap for all three lights to light. Note: Cambiatta records your ride data for download, but does not display information during your ride. B. Software Download and Set-up: 6. Download software at http://www.cambiatta.com/software/download.php 7. Register software during application start up by selecting REGISTER NOW. 8. To set up your unique rider/user profile, go to: FILE ยป NEW ยป CYCLIST. Note: Profile defaults to "Super Mario" and can be found in upper left on your screen. Once you have successfully set your own profile that unique name will appear in upper left of your screen. NOTE: For support during installation and set-up, select HELP in the application. C. Additional Useful Information: 9. Additional technical support at http://www.cambiatta.com/support/ 10. FAQ's at http://www.cambiatta.com/support/faq.php 11. Cambiatta is totally wireless and submersible to 3 meters. Congratulations! You are now ready to begin using Cambiatta. *Changes or modifications not expressly approved by Cambiatta could void the user's authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. FCC ID: S84-CM1
Rhein Tech Laboratories, Inc. Client: Cambiatta 360 Herndon Parkway Model: Cambiatta CM1 Suite 1400 Standards: FCC 15.209 Herndon, VA 20170 Report Number: 2005067 http://www.rheintech.com Date: May 3, 2005 13 of 26 APPENDIX B: CONFIDENTIALITY REQUEST Please refer to the following page.
Rhein Tech Laboratories, Inc. Client: Cambiatta 360 Herndon Parkway Model: Cambiatta CM1 Suite 1400 Standards: FCC 15.209 Herndon, VA 20170 Report Number: 2005067 http://www.rheintech.com Date: May 3, 2005 12 of 26 APPENDIX A: AGENCY AUTHORIZATION Please refer to the following page.
Rhein Tech Laboratories, Inc. Client: Cambiatta 360 Herndon Parkway Model: Cambiatta CM1 Suite 1400 Standards: FCC 15.209 Herndon, VA 20170 Report Number: 2005067 http://www.rheintech.com Date: May 3, 2005 20 of 26 APPENDIX I: EXTERNAL PHOTOGRAPHS PHOTOGRAPH 4: TRANSMITTER FRONT VIEW PHOTOGRAPH 5: TRANSMITTER BACK VIEW
Rhein Tech Laboratories, Inc. Client: Cambiatta 360 Herndon Parkway Model: Cambiatta CM1 Suite 1400 Standards: FCC 15.209 Herndon, VA 20170 Report Number: 2005067 http://www.rheintech.com Date: May 3, 2005 21 of 26 PHOTOGRAPH 6: DATA LOGGER FRONT VIEW PHOTOGRAPH 7: DATA LOGGER BACK VIEW
Rhein Tech Laboratories, Inc. Client: Cambiatta 360 Herndon Parkway Model: Cambiatta CM1 Suite 1400 Standards: FCC 15.209 Herndon, VA 20170 Report Number: 2005067 http://www.rheintech.com Date: May 3, 2005 24 of 33 PHOTOGRAPH 8: USB CABLE FRONT VIEW
Rhein Tech Laboratories, Inc. Client: Cambiatta 360 Herndon Parkway Model: Cambiatta CM1 Suite 1400 Standards: FCC 15.209 Herndon, VA 20170 Report Number: 2005067 http://www.rheintech.com Date: May 3, 2005 25 of 33 PHOTOGRAPH 9: USB CABLE BACK VIEW
Rhein Tech Laboratories, Inc. Client: Cambiatta 360 Herndon Parkway Model: Cambiatta CM1 Suite 1400 Standards: FCC 15.209 Herndon, VA 20170 Report Number: 2005067 http://www.rheintech.com Date: May 3, 2005 17 of 26 APPENDIX F: LABEL AND LOCATION FIGURE 5-1: FCC ID LABEL SAMPLE PHOTOGRAPH 1: FCC ID LABEL LOCATION ON TRANSMITTER BACK FCC ID: S84-CM1 FCC ID LABEL HERE
Rhein Tech Laboratories, Inc. Client: Cambiatta 360 Herndon Parkway Model: Cambiatta CM1 Suite 1400 Standards: FCC 15.209 Herndon, VA 20170 Report Number: 2005067 http://www.rheintech.com Date: May 3, 2005 23 of 26 APPENDIX J: INTERNAL PHOTOGRAPHS PHOTOGRAPH 10: FRONT OF TRANSMITTER CIRCUIT BOARD IN HOUSING PHOTOGRAPH 11: FRONT OF TRANSMITTER CIRCUIT BOARD IN HOUSING WITH TAPE LIFTED
Rhein Tech Laboratories, Inc. Client: Cambiatta 360 Herndon Parkway Model: Cambiatta CM1 Suite 1400 Standards: FCC 15.209 Herndon, VA 20170 Report Number: 2005067 http://www.rheintech.com Date: May 3, 2005 24 of 26 PHOTOGRAPH 12: TRANSMITTER PCB BACK VIEW PHOTOGRAPH 13: TRANSMITTER FRONT AND BACK COVER - INSIDE VIEW
Rhein Tech Laboratories, Inc. Client: Cambiatta 360 Herndon Parkway Model: Cambiatta CM1 Suite 1400 Standards: FCC 15.209 Herndon, VA 20170 Report Number: 2005067 http://www.rheintech.com Date: May 3, 2005 25 of 26 PHOTOGRAPH 14: TRANSMITTER COVER AND BATTERY PHOTOGRAPH 15: USB CABLE INSIDE VIEW
Rhein Tech Laboratories, Inc. Client: Cambiatta 360 Herndon Parkway Model: Cambiatta CM1 Suite 1400 Standards: FCC 15.209 Herndon, VA 20170 Report Number: 2005067 http://www.rheintech.com Date: May 3, 2005 26 of 26 PHOTOGRAPH 16: USB CABLE PCB PHOTOGRAPH 17: USB CABLE HOUSING INSIDE VIEW
Engineering and Testing for EMC and Safety Compliance 360 Herndon Parkway Suite 1400 Herndon, VA 20170 Phone: 703-689-0368 Fax: 703-689-2056 F F C C C C T T Y Y P P E E C C E E R R T T I I F F I I C C A A T T I I O O N N R R E E P P O O R R T T For Cambiatta, LLC 1026 Delta Avenue, Suite A Cincinnati, Ohio 45208 Phone: 513-871-9200 [email protected] www.cambiatta.com MODEL: Cambiatta CM1 FCC ID: S84-CM1 May 3, 2005 Standards Referenced for This Report American National Standard Institute ANSI C63.4: Methods of Measurement of Radio-Noise Emissions from Low- Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz FCC Rules Part 2: 2004 Frequency Allocations and Radio Treaty Matters; General Rules and Regulations FCC Rules Part 15: 2004 ยง15.209: Radiated Emissions Limits Frequency Range (MHz) Output Power (W) Frequency Tolerance Emission Designator .125 N/A N/A N/A REPORT PREPARED BY TEST ENGINEER: DANIEL BIGGS Document Number: 2005067/QRTL05-086 This report may not be reproduced without the full written approval of Rhein Tech Laboratories, Inc. Rhein Tech Laboratories, Inc. Client: Cambiatta 360 Herndon Parkway Model: Cambiatta CM1 Suite 1400 Standards: FCC 15.209 Herndon, VA 20170 Report Number: 2005067 http://www.rheintech.com Date: May 3, 2005 2 of 26 Table of Contents 1 GENERAL INFORMATION ....................................................................................................................................... 4 1.1 TEST FACILITY.................................................................................................................................................................. 4 1.2 PRODUCT DESCRIPTION................................................................................................................................................. 4 2 CONFORMANCE STATEMENT ............................................................................................................................... 5 3 TESTED SYSTEM DETAILS..................................................................................................................................... 6 3.1 EXERCISING THE EUT ..................................................................................................................................................... 6 4 FCC RULES AND REGULATIONS PART 15 ยง15.209 RADIATED EMISSIONS...................................................... 8 4.1 TEST METHODOLOGY FOR RADIATED EMISSIONS MEASUREMENTS ....................................................................... 8 4.2 RADIATED EMISSIONS DATA .......................................................................................................................................... 9 5 CONCLUSION......................................................................................................................................................... 11 Rhein Tech Laboratories, Inc. Client: Cambiatta 360 Herndon Parkway Model: Cambiatta CM1 Suite 1400 Standards: FCC 15.209 Herndon, VA 20170 Report Number: 2005067 http://www.rheintech.com Date: May 3, 2005 3 of 26 Table of Figures F IGURE 3-1: CONFIGURATION OF TESTED SYSTEM............................................................................................................... 7 FIGURE 5-1: FCC ID LABEL SAMPLE................................................................................................................................17 Table of Tables TABLE 3-1: EQUIPMENT UNDER TEST (EUT) ..........................................................................................................................6 TABLE 3-2: SUPPORT EQUIPMENT......................................................................................................................................... 6 TABLE 4-1: SPURIOUS AND FUNDAMENTAL EMISSIONS TEST DATA........................................................................................... 9 TABLE 4-2: TEST EQUIPMENT FOR RADIATED EMISSIONS...................................................................................................... 10 Table of Appendices A PPENDIX A: AGENCY AUTHORIZATION.............................................................................................................................. 12 APPENDIX B: CONFIDENTIALITY REQUEST.......................................................................................................................... 13 APPENDIX C: OPERATIONAL DESCRIPTION......................................................................................................................... 14 APPENDIX D: SCHEMATICS............................................................................................................................................... 15 APPENDIX E: BLOCK DIAGRAM.......................................................................................................................................... 16 APPENDIX F: LABEL AND LOCATION................................................................................................................................... 17 APPENDIX G: MANUAL...................................................................................................................................................... 18 APPENDIX H: TEST CONFIGURATION PHOTOGRAPHS........................................................................................................... 19 APPENDIX I: ExTERNAL PHOTOGRAPHS............................................................................................................................ 20 APPENDIX J: INTERNAL PHOTOGRAPHS............................................................................................................................. 23 Table of Photographs P HOTOGRAPH 1: FCC ID LABEL LOCATION ON TRANSMITTER BACK...................................................................................... 17 PHOTOGRAPH 2: RADIATED EMISSIONS โ FRONT VIEW.....................................โฆ
Text truncated - open the document above for the full version.
Rhein Tech Laboratories, Inc. Client: Cambiatta 360 Herndon Parkway Model: Cambiatta CM1 Suite 1400 Standards: FCC 15.209 Herndon, VA 20170 Report Number: 2005067 http://www.rheintech.com Date: May 3, 2005 19 of 26 APPENDIX H: TEST CONFIGURATION PHOTOGRAPHS PHOTOGRAPH 2: RADIATED EMISSIONS โ FRONT VIEW PHOTOGRAPH 3: RADIATED EMISSIONS โ BACK VIEW
360 Herndon Parkway, Ste 1400 ยท Herndon, Virginia ยท United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.125 MHz - 0.125 MHz | - |