FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Zhongshan Youlong Electrical Appliances Co.,Ltd./
  3. SAUYLK9

SAUYLK9Induction cooker

Zhongshan Youlong Electrical Appliances Co.,Ltd.
Induction cooker - FCC ID SAUYLK9 - Zhongshan Youlong Electrical Appliances Co.,Ltd.
Click to zoom

Application Details

Equipment Class
8CC - Part 18 Consumer Device
Date of Grant
Mar 10, 2013
Application Purpose
Original Equipment
Date of Application
Mar 10, 2013
Equipment Note
Induction cooker
Frequency Range
0.02000000 - 0.03000000
Company
Zhongshan Youlong Electrical Appliances Co.,Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

; 1 Induction Cooker YL-K9 Instruction Manual 1. Electrical Parameter Power: 1300W Voltage: 120V AC/ 60Hz 2. Operation Instruction 1. Switch on Plug in, and the cooker alerts “Bi”, LED tube flashes “----“, and the power indicator keeps flickering. Then press “On/ Off” button, LED tube displays “on”, the power indicator lights, and the cooker is in standby mode and ready for working. Then press “Function” button to select cooking mode. 2. Switch Off When in working or standby mode, press “On/ Off” button to switch off the cooker. 3. Timer 1) Timer is available in manual-control cooking modes, and the time can be set 1 min ~ 3 hours. 2)When in manual-control cooking mode, press “Timer” button, LED tube flashes “0:00”.Then press “+” button to increase time by 1 min each time, and keep pressing “+” to increase the time by 10 min each time. Press “-” button to decrease time by 1 min each time, and keep pressing “-” to decrease the time by 10 min each time. Then press “Timer” again to fix the time, or 5 seconds later without any operation, the time is fixed automatically. Otherwise, if you do not set the time, the cooker will cancel the timer setting 5 seconds later. 3) After the time is fixed, the LED tube alternately displays the time and wattage or temperature every 5 seconds. 4) After the timer is set, press “Timer” button, the LED tube displays the time left; keep pressing “Timer” button to cancel the timer. ; 2 4. Child Lock In working mode, keep pressing “Child Lock” button for 3 seconds, the child lock indicator lights, and all other functions are locked. Then keep pressing “Child Lock” button for 3 seconds again to unlock all, and the child lock indicator goes out. 5. Menu When in working or standby mode, press “Menu” button to select the cooking function required. 6. Heating (Manual-Control) 1) When in standby mode or other working mode, press “Menu” button to select heating function, the power indicator lights and LED tube displays “1300”, the cooker starts to keep heating at 1300W. 2) Press “+” button to increase the power and press “-“ button to decrease it. 3) Timer can be set in this cooking mode, after timer fixed, LED tube alternately displays the time and power. 7. Warm Keeping (Manual-Control) 1) When in standby mode or other working mode, press “Menu” button to select warm keeping function, the temperature indicator lights and LED tube displays “464F”, the cooker starts to work at 464°F. 2) Press “+” button to increase the temperature and press “-“ button to decrease it. 3) Timer can be set in this cooking mode, after timer fixed, LED tube alternately displays the time and temperature. 3. Faults Analysis Fault Code Description Retry or not Display or not Buzzer E0 No pot/ pot too small E2 Sensor open/short circuit E3 Voltage > 150V ; 3 E4 Voltage < 70V E5 Furnace overheat E6 IGBT overheat Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment For all industrial, scientific, medical (ISM) devices, the instruction manual, or if no instruction manual is provided the product packaging, must provide information (Section 18.213) that addresses the following: (1) interference potential of the device, (2) maintenance of the system and (3) simple measures that can be taken to correct interference. RF lighting devices must add a statement similar to the following: “This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment, ships at sea or other critical navigation or communications equipment operating between 0.45‐30 MHz.” Please provide necessary information in the user manual.

External Photos

Dongguan Dongdian Testing Service Co., Ltd Report No: DDT-F130012 Page 17 of 24 6. Photos of the EUT Dongguan Dongdian Testing Service Co., Ltd Report No: DDT-F130012 Page 18 of 24 Dongguan Dongdian Testing Service Co., Ltd Report No: DDT-F130012 Page 19 of 24

ID Label/Location Info

Induction cooker M/N:YL-K9 FCC ID: SAUYLK9 Zhongshan Youlong Electrical Appliances Co.,Ltd.

Internal Photos

Dongguan Dongdian Testing Service Co., Ltd Report No: DDT-F130012 Page 20 of 24 Dongguan Dongdian Testing Service Co., Ltd Report No: DDT-F130012 Page 21 of 24 Dongguan Dongdian Testing Service Co., Ltd Report No: DDT-F130012 Page 22 of 24 Dongguan Dongdian Testing Service Co., Ltd Report No: DDT-F130012 Page 23 of 24 Dongguan Dongdian Testing Service Co., Ltd Report No: DDT-F130012 Page 24 of 24 END OF REPORT

Test Setup Photos

Dongguan Dongdian Testing Service Co., Ltd Report No: DDT-F130012 Page 15 of 24 5. Test setup photograph 5.1. Photos of power line conducted emission test Dongguan Dongdian Testing Service Co., Ltd Report No: DDT-F130012 Page 16 of 24 5.2. Photos of radiated emission test

Contact Information

Applicant

Randy Liu(Manager)
[email protected]+86-0760-23237686Fax: +86-0760-23237686

Test Firm

Dongguan Dongdian Testing Service Co.,LtdJamy Yu
[email protected]086-0769-22891499

Technical Specifications

#Rule PartsFrequency RangePower Output
1180.02 MHz - 0.03 MHz-
Confidentiality
Long Term