
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
R& D Electronics s.r.l. Stab. Via D. Beccafumi, 61/65 00133 Roma Tel.+39 06 2008368 Fax.+39 06 20686322 e-mail: [email protected] SECURITY EQUIPMENTS P.iva 04598541003 - Sede Leg. Via Livio Salinatore, 22 00175 Roma - Cap.Soc. 10.400,00 i.v. C.C.I.A.A. N°785481 Tribunale 243/94 DECLARATION THAT DESCRIBES THE DIFFERENCES BETWEEN AKAB-M AND AKAB-W AND EXPLAINS WHY AKAB-W MEASUREMENTS COVERS AKAB-M. The two equipments are made with the same components, circuits and software the AKAB-M does not have the antimask circuit that is composed by one relay and one amplifier that gain 30. So if testing the AKAB-W, you will automatically test the AKAB-M De Amicis Vittorio
CETECOM ICT Services GmbH Test report No.: 2–3655–01–01/04Date : 29.06.2004Page 42 of 45 4.Photographs CETECOM ICT Services GmbH Test report No.: 2–3655–01–01/04Date : 29.06.2004Page 43 of 45 CETECOM ICT Services GmbH Test report No.: 2–3655–01–01/04Date : 29.06.2004Page 44 of 45 CETECOM ICT Services GmbH Test report No.: 2–3655–01–01/04Date : 29.06.2004Page 45 of 45
CETECOM ICT Services GmbH Test report No.: 2–3655–01–01/04Date : 29.06.2004Page 42 of 45 4.Photographs CETECOM ICT Services GmbH Test report No.: 2–3655–01–01/04Date : 29.06.2004Page 43 of 45 CETECOM ICT Services GmbH Test report No.: 2–3655–01–01/04Date : 29.06.2004Page 44 of 45 CETECOM ICT Services GmbH Test report No.: 2–3655–01–01/04Date : 29.06.2004Page 45 of 45
CETECOM ICT Services GmbH Radio Satellite Communication Untertürkheimer Straße 6–10, D-66117 Saarbrücken, Telephone +49 (0) 681 598 - 0 , Fax +49 (0) 681 598 – 9 075 Test report No.: 2–3655–01–02/04This test report consists of 45 pagesPage 1 of 45 Recognized by the Federal Communications Commission and Industry Canada Anechoic chamber registration No. 90462 (FCC) Anechoic chamber registration No. 3463 (IC) TCB ID: DE0001 Accredited by the German Accreditation Council DAR–Registration Number TTI–P–G 081/94-D0 Independent ETSI compliance test house ETSI Test report No.:2–3655–01–01/04 Applicant:R & D Electronics S.r.l. Type:Motion Detector Test standard:FCC Part 15 Member of RWTÜV Group CETECOM ICT Services GmbH Test report No.: 2–3655–01–01/04Date : 29.06.2004Page 2 of 45 Table of contents 1.General information............................................................................................................ 3 1.1.Notes .............................................................................................................................. 3 1.2.Testing laboratory ..........................................................................................................4 1.3.Details of applicant ........................................................................................................4 1.4.Application details .........................................................................................................4 1.5.Test item (EUT) .............................................................................................................5 1.6.Technical data ................................................................................................................ 5 1.6.1.Operation conditions ......................................................................................................5 1.6.2.Equipment under test .....................................................................................................5 1.7.Test standards:................................................................................................................ 6 1.8.Code of Federal Regulations (CFR 47).......................................................................... 6 2.Technical test...................................................................................................................... 7 2.1.Summary of test results .................................................................................................. 7 2.2.Test environment............................................................................................................7 2.3.Measurement and test set-up .......................................................................................... 7 2.4.Test equipment utilized and test set-up .......................................................................... 8 2.5.Test results ................................................................................................................... 12 3.Plots, graphs and data sheets ......................................................................................... 16 4.Photographs ..................................................................................................................... 42 CETECOM ICT Services GmbH Test report No.: 2–3655–01–01/04Date : 29.06.2004Page 3 of 45 1. General information 1.1. Notes The test results of this test report relate exclusively to the test item specified in 1.5.. CETECOM ICT Services GmbH does not assume responsibility for any conclusions and generalisations drawn from the test results with regard to other specimens or samples of the type of the equipment represented by the test item. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of the CETECOM ICT Services GmbH. Tester : 29.06.2004 Manfred Paschwitz DateNameSignature Technical responsibility for area of testing : 29.06.2004 Klaus Kammerinke DateNameSignature CETECOM ICT Services GmbH Test report No.: 2–3655–01–01/04Date : 29.06.2004Page 4 of 45 1.2. Testing laboratory CETECOM ICT Services GmbH Untertürkheimerstraße 6–10P.O. Box 10 04 45 66117 Saarbrücken66004 Saarbrücken GermanyGermany Telephone:+ 49 (0) 681 598–0 Fax:+ 49 (0) 681 598–9075 e-mail:[email protected] Internet:http://www.cetecom.de Accredited testing laboratory Accredited by: Regulierungsbehörde für Telekommunikation und Post (RegTP) Listed by: Federal Communications Commission (FCC) Industry Canada AuthorityIdentification/Registration No. RegTPTTI-P-G 081/94-D0 FCC90462 IC3463 Testing location, if different from CETECOM ICT Services GmbH: (Not applicable) Name:(Not applicable) 1.3. Details of applicant Name:R & D Electronics S.r.l. Street:Via Domenico Beccafumi, 61/65 Town:00133 Roma Country:Italy Telephone:+39 (0) 06 200 83 68 Fax:+39 (0) 06 208 63 22 Contact person Name:Mrs Cristina Ferre (Prima Recerca & Sviluppo S.r.l.) Telephone:+39 (0) 031 3500015 Fax:+39 (0) 031 991 309 e mail: 1.4. Application details Date of receipt of application :28.05.2004 Date of receipt of test item:28.05.2004 Date of test:28.06. - 29.06.2004 CETECOM ICT Services GmbH Test report No.: 2–3655–01–01/04Date : 29.06.2004Page 5 of 45 1.5. Test item (EUT) Description of EUT:Field disturbance sensor System designation:Motion detector/Intrusion detector for alarm equipment Type designation:Akab-w, Akab-m Manufacturer:R & D Electronics S.r.l. Street:Via Domenico Beccafumi, 61/65 Town:00133 Roma Country:Italy 1.6. Technical data Frequency range:10.500 GHz ... 10.550 GHz Operational frequency:10.525 GHz Field strength:100 mV/m Type of modulation :40M0P0N Pulse width:35.917 μs Pulse spacing:320.00 μs Pulse repetition frq.:3.125 kHz Microwave modules:TX / RX – Module with integral antenna Normal DC power supply:+12.0 V Extreme DC power supply:+8.4 V to +15.6 V 1.6.1. Operation conditions Operation::As soon as the equipment is powere…
Text truncated - open the document above for the full version.
CETECOM ICT Services GmbH Test report No.: 2–3655–01–01/04Date : 29.06.2004Page 42 of 45 4.Photographs CETECOM ICT Services GmbH Test report No.: 2–3655–01–01/04Date : 29.06.2004Page 43 of 45 CETECOM ICT Services GmbH Test report No.: 2–3655–01–01/04Date : 29.06.2004Page 44 of 45 CETECOM ICT Services GmbH Test report No.: 2–3655–01–01/04Date : 29.06.2004Page 45 of 45
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.245 | 10.53 GHz - 10.53 GHz | - |