Imaging System Technology You Can Count On! © 2003 Static Control Components, Inc. All rights reserved worldwide. The stylized S is a registered trademark, and Static Control and Multi-Tracker are trademarks of Static Control Components, Inc. All other brand and product names are trademarks or registered trademarks of their respective companies. SCC Imaging Division 3010 Lee Avenue • PO Box 152 • Sanford, NC 27331 US/Can 800 . 488 . 2426 • US/Can Fax 800 . 488 . 2452 Int’l 919 . 774 . 3808 • Int’l Fax 919 . 774 . 1287 www.scc-inc.com STATICCONTROLCOMPONENTS, INC. Static Control Components (Europe) Limited Unit 30, Worton Drive Reading • Berkshire RG2 0TG • United Kingdom Tel +44 (0) 118 . 923 . 8800 • Fax +44 (0) 118 . 923 . 8811 STATIC CONTROLINSTRUCTIONS The development of quality products for the remanufacturing of printer cartridges, is the primary mission of our Imaging Labs. Through extensive testing and research, we develop the optimum combination of matched components for each cartridge system. Our engineering and manufacturing expertise provides us with total control in design, quality and development to produce products from the ground up. The result is a system of components that seamlessly work together in each cartridge application. This dedication and commitment results in integrated cartridge systems that Static Control fully supports, allowing you to quickly attack new market opportunities with complete confidence in the reliability and performance of your cartridges. SSS ™ 684 STATIC CONTROLINSTRUCTIONS Version 1 Revision 1 - February 2005 SYSTEM SUPPORT SERIES ™ GO TO WWW.SCC-INC.COM For the latest cartridge information Click on “Online Engine Center” Other System Support Series ™ documents available in Adobe ® Acrobat ® format QUESTIONS? Please call one of our main numbers and ask for your Support Team Representative or E-mail us at: US AND CANADA [email protected] UK [email protected] PRODUCT INSTRUCTIONS FOR: STATSCAN 1 BOX HP RF DEVICES All brand names and trademarks are for descriptive purposes only and are the property of their respective owners. WWW.SCC-INC.COM US AND CANADA 800.488.2426 • INTERNATIONAL 919.774.3808 • EUROPE +44 (0) 118.923.8800 US/CAN FAX: 800-488-2452 • INTERNATIONAL FAX 919-774-1287 StatScan Chip Box (STATSCAN1) PPrroodduucctt DDeessccrriippttiioonn Static Control Components has developed a Chip Read/Write device for HP RF devices such as the 4100, 4600, 5500, 9000 etc. IItteemmss IInncclluuddeedd StatScan portable read/reset box (StatScan1). Power Supply for the StatScan (SPWRSUP). Control unit Cable to connect wand to StatScan (SCABLE). Wand to read/reset chip (SWAND-1) Adjustable Wrist Strap with 12’ cord (WBB-AFWS121M) OOtthheerr SSttaattSSccaann PPrroodduuccttss StatScan 2- HP Direct Connect StatScan 3- Lexmark StatScan 4- Xerox and Samsung CCoommpplliiaannccee SSttaatteemmeenntt This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. In accordance with 15.21 of the FCC rules, any changes or modifications to this equipment not expressly approved by Static Control Components, may cause interference and void the FCC authorization to operate this equipment. NNOOTTEE:: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. PPrriinntteerr MMooddeellOOEEMM AAddvveerrttiisseedd PPaaggee YYiieelldd 11 TTyyppiiccaall DDrruumm CCoouunntt 22 HP LaserJet 410010,00056,700 HP LaserJet 900030,000169,700 HP LaserJet 905030,000169,700 HP Color LaserJet9,00060,000 4600 (black) HP Color LaserJet 8,00056,900 4600 (colors) HP Color LaserJet9,00054,000 4650 (black) HP Color LaserJet8,00048,000 4650 (colors) HP Color LaserJet13,00082,300 5500 (black) HP Color LaserJet12,00076,000 5500 (colors) HP Color LaserJet13,00086,500 5550 (black) HP Color LaserJet12,00079,900 5550 (colors) Canon EP-85 (black)9,00060,000 Canon EP-85 (colors)8,00056,900 Canon EP-86 (black)13,000125,700 Canon EP-86 (colors)12,000116,000 Notes: 1 OEM Advertised Yield is the page yield expectation published by the OEM, which is usually based on a 5% toner page coverage. 2 Typical Drum Count is the estimated number of full drum rotations if the OEM advertised yield pages are printed and the average print job size is 3 pages. Estimation derived from proprietary SCC research. How to use the StatScan Chart of T ypical Drum Counts Component wear is highly correlated with OPC drum rotations. Drum rotations, or drum count, depends upon the specific printer model, the number of pages printed and the average print job size. The combination of these factors is reflected in the number of drum rotations. SCC has conducted research to determine the number of drum rotations per printer model given a standard baseline for usage patterns. The standard baselines used for measuring typical dr…
Text truncated - open the document above for the full version.
April 8, 2005 TUV Rhineland North America, Inc. 10040 Mese Rim Road San Diego, CA 92121 RE: Request of Confidentiality for STATSCAN-WRF01 Dear Sir: Pursuant to sections 0.457(d)(1)(ii) and 0.459 of the commissioned rules, the applicant hereby requests confidential treatment of information accompanied as outlined below: 1. Detailed operation of description; 2. Schematic drawings; 3. Detailed block drawings; The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjust benefits to his competitors. The applicant understands that pursuant to rule 0.457(d)(1)(ii) disclosure of this application and all accompanying documentation will not be made before the date of the grant for this application. Very truly yours, Jeff Duve Static Control Components, Inc. WLL/mfm
Static Control Components Inc. 2515 Cox Mill Road / Plant 8 Sanford, NC 27330 (919)774-3808 StatScan RF FCC LABEL File: I:\customers\Static Control Components\30462683.001 Stat_Scan_RF\TCB2\STATSCAN-WRF01 Label 040805.doc Page 1 of 1 Date: 4/8/05 Time: 11:26 AM FCC ID: SD5 STATSCAN-WRF01 Made in the USA by Static Control Components, Inc. This device complies with Part 15 of the FCC Rules . Operation is subject to the following two conditions : (1) this device may not cause harmful interference , and (2) this device must accept any interference received , including interference that may cause undesired operation.
Report Number: 30462684.001 Page 1 of 26 EUT: StatScan-CU with StatScan-Wand-WRF01 Model: SD5-StatScan-WRF01 33_EME/I 01/29/2001 FCCID: STATSCAN-WRF01 Emissions Test Report EUT Name: StatScan-CU with StatScan-Wand-WRF01 EUT Model: SD5-StatScan-WRF01 FCC Title 47, Part 15, Subpart B and C, RSS-210 Issue 5 Prepared for: Jeff Duve Static Control Components 2515 Cox Mill Rd. Plant 8 Sanford NC 27330 Tel: 919-774-3808 Fax: 919-718-5434 Prepared by: TUV Rheinland of North America 762 Park Avenue Youngsville, NC 27596 Tel: (919) 554-3668 Fax: (919) 554-3542 http://www.tuv.com/ Report/Issue Date: 29 March 2005 Report Number: 30462684.001 Statement of Compliance Report Number: 30462684.001 Page 2 of 26 EUT: StatScan-CU with StatScan-Wand-WRF01 Model: SD5-StatScan-WRF01 33_EME/I 01/29/2001 FCCID: STATSCAN-WRF01 Manufacturer: Static Control Components 2515 Cox Mill Rd. Plant 8 Sanford NC 27330 919-774-3808 Requester / Applicant: Jeff Duve Name of Equipment: StatScan-CU with StatScan-Wand-WRF01 Model No. SD5-StatScan-WRF01 Type of Equipment: Information Technology Equipment (ITE) Class of Equipment: Class B Application of Regulations: FCC Title 47, Part 15, Subpart B and C, RSS-210 Issue 5 Test Dates: 15 November 2004 to 15 November 2004 Guidance Documents: Emissions: FCC 47 CFR Part 15 and RSS-210 Issue 5 Test Methods: Emissions: EN55022:1998 + A1:2000 + A2:2003, ANSI C63.4:2003 The electromagnetic compatibility test and documented data described in this report has been performed and recorded by TUV Rheinland of North America, in accordance with the standards and procedures listed herein. As the responsible authorized agent of the EMC laboratory, I hereby declare that a sample of one, of the equipment described above, has been shown to be compliant with the EMC requirements of the stated regulations and standards based on these results. If any special accessories and/or modifications were required for compliance, they are listed in the Executive Summary of this report. This report must not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. This report contains data that are not covered by NVLAP accreditation. This report shall not be reproduced except in full, without the written authorization of the laboratory. 29 March 2005 NVLAP Signatory Date Table of Contents Report Number: 30462684.001 Page 3 of 26 EUT: StatScan-CU with StatScan-Wand-WRF01 Model: SD5-StatScan-WRF01 33_EME/I 01/29/2001 FCCID: STATSCAN-WRF01 1 EXECUTIVE SUMMARY................................................................................................................. 4 1.1 SCOPE............................................................................................................................................ 4 1.2 PURPOSE........................................................................................................................................ 4 1.3 SUMMARY OF TEST RESULTS........................................................................................................ 4 1.4 SPECIAL ACCESSORIES.................................................................................................................. 4 1.5 EQUIPMENT MODIFICATIONS........................................................................................................ 4 2 LABORATORY INFORMATION ................................................................................................... 5 2.1 ACCREDITATIONS & ENDORSEMENTS.......................................................................................... 5 2.2 TEST FACILITIES............................................................................................................................ 5 2.3 MEASUREMENT UNCERTAINTY..................................................................................................... 6 2.4 CALIBRATION TRACEABILITY....................................................................................................... 6 3 PRODUCT INFORMATION ............................................................................................................7 3.1 PRODUCT DESCRIPTION................................................................................................................ 7 3.2 EQUIPMENT CONFIGURATION....................................................................................................... 7 3.3 OPERATION MODE........................................................................................................................ 8 4 EMISSIONS ........................................................................................................................................ 8 4.1 RADIATED EMISSIONS................................................................................................................... 8 4.2 CONDUCTED EMISSIONS............................................................................................................. 15 4.3 MEASUREMENT OF FREQUENCY STABILITY VERSUS TEMPERATURE........................................ 19 4.4 BANDWIDTH TEST FOR BAND EDGE COMPLIANCE..................................................................... 20 5 TEST EQUIPMENT USE LIST ...................................................................................................... 20 6 EMC TEST PLAN ............................................................................................................................ 20 TUV Rheinland of North America Scope 762 Park Ave., Youngsville, NC 27596 Tel: (919) 554-3668, Fax: (919) 554-3542 Report Number: 30462684.001 Page 4 of 26 EUT: StatScan-CU with StatScan-Wand-WRF01 Model: SD5-StatScan-WRF01 33_EME/I 01/29/2001 FCCID: STATSCAN-WRF01 1 Executive Summary 1.1 Scope This report is intended to document the status of conformance with the requirements of the FCC Title 47, Part 15, Subpart B and C, RSS-210 Issue 5 based on the results of testing performed on 15 November 2004 through 15 November 2004 on the StatScan-CU …
Text truncated - open the document above for the full version.
3010 Lee Avenue · Sanford, North Carolina · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 13.56 MHz - 13.56 MHz | - |